首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A straightforward and common analytical method for α‐tocopherol (αT) determination in various biological samples, including plasma, red blood cells (RBC), tissues and cultured cell lines, was developed and validated, using a reverse phase‐chromatographic method (RP‐HPLC). Even though many chromatographic methods for αT determination have been reported, most of them require readjustment when applied to different types of samples. Thus, an effective and simple method for αT determination in different biological matrices is still necessary, specifically for translational research. This method was applied using a C18 column (250 × 4.6 mm, 5 µm particle size) under isocratic elution with MeOH:ACN:H2O (90:9:1 v/v/v) at a flow rate of 1 mL/min and detected using photodiode array at 293 nm. Linearity (r >0.9997) was observed for standard calibration with inter‐ and intraday variation of standard <4%. Lower limits of detection and quantification for αT in this assay were 0.091 and 0.305 µg/mL respectively. Validation proved the method to be selective, linear, accurate and precise. The method was successfully applied in great variety of biological samples, that is, human and mouse plasma, RBCs, murine tissues and human/mouse/rat cultured cell lines. More importantly, a single protocol of extraction and detection can be applied, making this method very convenient for standardization of different types of samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
A new, simple procedure for the determination of phenolic components of wines, such as resveratrol and piceid isomers, has been elaborated and validated. A set of 70 red wines and 3 white wines from two wineries (Polgar Winery and Bock Winery, Villany, Hungary) are analyzed by reversed-phase high-performance liquid chromatography. The samples are injected without pretreatment and UV-vis and mass spectrometric (MS) detection has been applied. The detection limit for trans-resveratrol and for trans-piceid is found to be 0.9 and 0.6 pmol for the UV-vis detection method and 0.3 and 0.2 pmol for the MS detection method. Trans-resveratrol and trans-piceid are found in red wines from 0.1 to 14.3 mg/L and from 3.8 to 16.4 mg/L concentrations, respectively.  相似文献   

3.
A sensitive and rapid high-performance liquid chromatographic assay is developed and validated for the determination of buformin in plasma. After addition of metformin as the internal standard, the analytes were deproteinated with acetonitrile, washed with dichloromethane, and the resulting supernatant injected. Chromatography was performed at ambient temperature by pumping a mobile phase of 0.03 m diammonium hydrogen phosphate buffer (pH 7, 250 mL) in methanol (750 mL) at a fl ow rate of 1 mL/min through a silica column. Buformin and metformin were detected at 236 nm, and eluted 9.8 and 15.4 min, respectively. No endogenous substances were found to interfere. Calibration curves were linear over the concentration range of 20-2000 ng/mL. The limit of quantitation was 20 ng/mL. The intra- and inter-day relative standard deviation (RSD) was 8.3%, or less, and the accuracy was within 10.1% of the relative error (RE). The method is suitable in pharmacokinetic investigation of buformin.  相似文献   

4.
This work is concerned with novel, accurate and precise determination of two common insecticides, imiprothrin and deltamethrin, using HPLC. The chromatographic conditions were optimised for the best separation. The column was Intersil ODS (4.6 x 250 mm with 5 µm particle size). The mobile phase consists of a mixture of acetonitrile and water (90:10, v/v) at a flow rate of 1.2 mL/min. UV detection was accomplished at 230 nm using chlorpyriphos as an internal standard. The method was validated according to International Conference on Harmonization (ICH) guidelines and was found to be linear over the range 7.5–45 µg/mL for imiprothrin and 5–30 µg/mL for deltamethrin. The method was applied to the assay of both insecticides in the combined spray formulation from the Egyptian market. Statistical comparison between the proposed and the reported methods showed no significant difference. The method can be applied for simultaneous determination of both compounds in different market products with high specificity and in quality control laboratories for insecticide residue monitoring.  相似文献   

5.
2‐Deoxyglucose (2‐DG), an analog of glucose, is widely used to interfere with glycolysis in tumor cells and studied as a therapeutic approach in clinical trials. To evaluate the pharmacokinetics of 2‐DG, we describe the development and validation of a sensitive HPLC fluorescent method for the quantitation of 2‐DG in plasma. Plasma samples were deproteinized with methanol and the supernatant was dried at 45°C. The residues were dissolved in methanolic sodium acetate–boric acid solution. 2‐DG and other monosaccharides were derivatized to 2‐aminobenzoic acid derivatives in a single step in the presence of sodium cyanoborohydride at 80°C for 45 min. The analytes were separated on a YMC ODS C18 reversed‐phase column using gradient elution. The excitation and emission wavelengths were set at 360 and 425 nm. The 2‐DG calibration curves were linear over the range of 0.63–300 µg/mL with a limit of detection of 0.5 µg/mL. The assay provided satisfactory intra‐day and inter‐day precision with RSD less than 9.8%, and the accuracy ranged from 86.8 to 110.0%. The HPLC method is reproducible and suitable for the quantitation of 2‐DG in plasma. The method was successfully applied to characterize the pharmacokinetics profile of 2‐DG in patients with advanced solid tumors. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and sensitive HPLC method was developed and validated for the determination of four frequently prescribed 1,4-benzodiazepines: alprazolam (ALP), bromazepam (BRZ), diazepam (DZP), and flunitrazepam (FNZ). Separation was achieved on an Inertsil C8 analytical (250 mm x 4 mm, 5 microm) column, after selective extraction of benzodiazepine drugs from biological matrices by means of SPE. Isocratic elution was performed with a mobile phase consisting of CH3COONH4, 0.05 M CH3OH, and CH3CN (33:57:10 by volume). Quantification was performed at 240 nm with mefenamic acid (6 ng/microL) as the internal standard. DSC-18 Supelco cartridges provided high absolute recoveries (81-115%). The developed method was fully validated in terms of selectivity, linearity, accuracy, precision, stability, and sensitivity. Repeatability (n = 8) and between-day precision (n = 8) revealed RSD <12%. Recoveries from biological samples ranged from 81.2 to 115%. The detection limit of the method was calculated as 3.3-10.2 ng in blood plasma and 2.6-12.6 ng in urine for 20 microL injection volume. The method was applied to spiked biological matrices. Moreover, the method was applied to real samples of urine after an oral administration.  相似文献   

7.
A high-performance liquid chromatographic method was developed, validated and applied to the simultaneous determination of 5-aminosalicylic acid (5-ASA) and its acetylated metabolite (acetyl-5-ASA) in human plasma. The method involves liquid-liquid extraction with methanol followed by isocratic reversed-phase chromatography on a Kromasil KR100 C(18) column with electrochemical detection. The recovery, selectivity, linearity, precision and accuracy of the method were evaluated from spiked human plasma samples. The effects of mobile phase composition, buffer concentration, mobile phase pH and concentration of organic modifiers on retention of 5-ASA, acetyl 5-ASA and internal standard were investigated. Limits' of detection were 5 ng/mL for 5-ASA and 10 ng/mL for acetyl-5-ASA, respectively. The method can be used for supporting therapeutical drug monitoring and pharmacokinetic studies.  相似文献   

8.
A simple, accurate, and reproducible high‐performance liquid chromatography (HPLC) method has been developed and validated for the quantification of quercetin (QR) in rat plasma. The method involves a simple protein precipitation procedure to extract both QR and thymoquinone (TQ), the internal standard. The chromatographic analysis was achieved on a Shimadzu LC 20 A HPLC system equipped with a Supelcosil LC‐18 T C18 column and an isocratic mobile phase consisting of 0.3% trichloroacetic acid in water and acetonitrile HPLC‐grade (50:50, v /v) run at a flow rate of 0.9 mL/min for 13 min. The UV detection wavelength was set at 254 nm. The method exhibited good linearity (R 2 > 0.994) over the assayed concentration range (0.10–25 μg/mL) and demonstrated good intra‐day and inter‐day precision and accuracy (relative standard deviations and the deviation from predicted values were <20%). This method was also successfully applied for studying the pharmacokinetics of QR in rats following a single oral dose of QR to evaluate its pharmacokinetic parameters in rats.  相似文献   

9.
The precise quantitative analysis of biomass sugars is a very important step in the conversion of biomass feedstocks to fuels and chemicals. However, the most accurate method of biomass sugar analysis is based on the gas chromatography analysis of derivatized sugars either as alditol acetates or trimethylsilanes. The derivatization method is time consuming but the alternative high-performance liquid chromatography (HPLC) method cannot resolve most sugars found in biomass hydrolysates. We have demonstrated for the first time that by careful manipulation of the HPLC mobile phase, biomass monomeric sugars (arabinose, xylose, fructose, glucose, mannose, and galactose) can be analyzed quantitatively and there is excellent baseline resolution of all the sugars. This method was demonstrated for standard sugars, pretreated corn stover liquid and solid fractions. Our method can also be used to analyze dimeric sugars (cellobiose and sucrose).  相似文献   

10.
An HPLC method was developed for the simultaneous determination of seven water-soluble vitamins, viz. thiamine, riboflavin, nicotinic acid, nicotinamide, pyridoxine, cyanocobalamin, and folic acid, in multivitamin pharmaceutical formulations and biological fluids (blood serum and urine). Separation was achieved at ambient temperature on a Phenomenex Luna C18 (150 x 4.6 mm) analytical column. Gradient elution was performed starting at a 99:1 A:B v/v composition, where A: 0.05 M CH3COONH4/CH3OH (99/1) and B: H2O/CH3OH (50/50), at a flow rate of 0.8 mL/min. After a 4-min isocratic elution the composition was changed to 100% of B in 18 min and elution continued isocratically for 8 min. Detection was performed with a photodiode array detector at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples. Detection limits were in the range of 1.6-3.4 ng, per 20-microL injection, while linearity held up to 25 ng/microL. Accuracy, intra-day repeatability (n = 6), and inter-day precision (n = 7) were found to be satisfactory. Theobromine (2 ng/microL) was used as internal standard. Sample preparation of biological fluids was performed by SPE on Supelclean LC-18 cartridges with methanol-water 85/15 v/v as eluent. Extraction recoveries from biological matrices ranged from 84.6% to 103.0%.  相似文献   

11.
A simple, accurate and reproducible high‐performance liquid chromatography (HPLC) method has been developed and validated for the quantification of sulforaphane (SF) in rat plasma. The method involves a simple liquid–liquid extraction procedure to extract both SF and 7‐hyrdoxycoumarin, the internal standard. The chromatographic analysis was achieved on a Shimadzu LC 20A HPLC system equipped with a Zorbax Eclipse XDB C18 column and an isocratic mobile phase consisting of 10 mm KH2PO4 (pH 4.5) and acetonitrile HPLC grade (40:60, v/v) run at a flow rate of 1 mL/min for 10 min. The UV detection wavelength was set at 202 nm. The method exhibited good linearity (R2 > 0.999) over the assayed concentration range (0.05–2 μg/mL) and demonstrated good intra‐ and inter‐day precision and accuracy (relative standard deviations and the deviation from predicted values were <15%). This method was also successfully applied for studying the pharmacokinetics of SF in spontaneously hypertensive rats following single oral dietary doses of SF. The pharmacokinetics of SF show linear behavior at the dose range investigated in this study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
In this stability-indicating, reversed-phase high-performance liquid chromatographic method for nicardipine (NIC), forced degradation has been employed and the formed degradants were separated on a C18 (150 mm × 3.9 mm, 5 μm) analytical column using a mobile phase consisted of 70% methanol: acetic acid containing 0.01 M triethylamine with pH 4. The flow rate was 1.0 mL/min and the photodiode array detection wavelength was 353 nm. Forced degradation of the drug was carried out under acidic, basic, photolytic, and oxidative stress conditions. Chromatographic peak purity data indicated no co-eluting peaks with the main peaks. This method resulted in the detection of seven degradation products. Among these, two major degradation products from basic hydrolysis, one from oxidation by H2O2 and four from photolytic stress were identified by mass spectral data. A good linear response was achieved over the range of 0.5–40 μg/mL with a limit of detection (LOD) of 0.011 μg/mL and limit of quantification (LOQ) of 0.036 μg/mL. The suggested method was successfully applied for the analysis of NIC in its commercial capsules, with mean% recovery value of 100.11 ± 2.26%. The method was extended to the in vitro determination on NIC in spiked human plasma samples with mean% recovery of 99.04 ± 5.67%. The suggested method was utilized to investigate the kinetics of photolytic induced degradation.  相似文献   

13.
In the present work, a sensitive, accurate and precise RP HPLC method has been established for simultaneous determination of sacubitril and valsartan from rat plasma by using irbesartan as an internal standard. Separation of analytes were carried out on monolithic column using 10?mM phosphate buffer (pH 2.6), methanol and acetonitrile in a proportion of 50:25:25 (v/v). Analytes were monitored using fluorescence detector maintained at an excitation wavelength of 249?nm and an emission wavelength was set at 380?nm till the elution of valsartan as well as internal standard and switched online to 320?nm for sacubitril. Analysis of analytes from rat plasma was carried out by protein precipitation using methanol and acetonitrile. Valsartan and sacubitril showed good linearity in the concentration range of 1–250?ng/ml and 1–200?ng/ml respectively, with good correlation coefficient (r2?≥?0.998). Further, the precision and accuracy of the proposed procedure were suitable as the percent relative standard deviation and percent relative error were well within the acceptable range. The average percent of recovery from the rat plasma was found to be 96.6% and 97.6% for valsartan and sacubitril respectively. The newly proposed method can be used for regular pharmacokinetic studies because of simplicity in sample preparation, short analysis time (<5?min) and good sensitivity.  相似文献   

14.
A simple and specific bioanalytical method based on reversed‐phase high‐performance liquid chromatography (RP‐HPLC) coupled with ultraviolet detection was developed and validated for the determination of a novel valproic acid arylamide, N‐(2‐hydroxyphenyl)‐2‐propylpentanamide (HO‐AAVPA) in rat hepatic microsomes (a subcellular fraction containing phase I enzymes, especially cytochrome P450). The chromatographic separation was achieved using a reversed‐phase Zorbax SB‐C18 column and a mobile phase of acetic acid in water (0.2% v/v) and acetonitrile (40:60 v/v) with a flow rate of 0.5 mL/min. The calibration curve was linear over the range of 882–7060 ng/mL (r2 = 0.9987), and the lower limit of quantification and the lower limit of determination were found to be 882 and 127.99 ng/mL, respectively. The method was validated with excellent sensitivity, and intra‐day accuracy and precision varied from 93.79 to 93.12%, and from 2.12 to 4.36%, respectively. The inter‐day accuracy and precision ranged from 93.29 to 97.30% and from 0.68 to 3.60%, respectively. The recovery of HO‐AAVPA was measured between 91.36 and 97.98%. The assay was successfully applied to the analysis of kinetic metabolism and pharmacokinetic parameters in vitro by a substrate depletion approach. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
A semi-preparative high-performance liquid chromatography process was evaluated as a tool to quantitatively determine the purity or percentage mass fraction content (% m/m) of organic compounds. The method is simple and does not require the identification and subsequent quantitation of organic-related structure impurities. A protocol was developed and tested on four reference materials certified for purity from 95% m/m to 99.3% m/m. Comparing the purity results of each certified reference material using the new approach with their respective certified values showed no significant analytical bias. Semi-preparative high-performance liquid chromatography has proved the potential to be a primary method directly traceable to mass with an uncertainty statement written down also in terms of mass with expanding uncertainty ranging from 0.8% to 1.3% m/m compared to 0.3 to 2.0% m/m for the certified purity values at the 95% confidence interval.  相似文献   

16.
A simple high-performance liquid chromatographic (HPLC) method was developed and validated for the quantification of mizoribine in human serum. After the addition of 70% perchloric acid and 3-methylxanthine (50 microg/mL, internal standard) to human serum, the samples were mixed and centrifuged at 12,000 rpm (1432 g) for 10 min. The supernatant was injected onto a C(18) column eluted with a mobile phase of 20 mm Na2HPO4 and methanol (93:7, v/v, pH 3) containing 0.04% octanesulfonic acid and detected utilizing an ultraviolet detector at 275 nm. The linear calibration curve was obtained in the concentration range of 0.1-4.0 microg/mL and the lower limit of quantification was 0.1 microg/mL. This method was validated with selectivity, linearity, precision and accuracy. In addition, the method was successfully applied to estimate the pharmacokinetic parameters of mizoribine in Korean subjects following an oral administration of 100 mg mizoribine (two Bredinine 50 mg tablets). The maximum serum concentration (C(max)) of 2.30 +/- 0.83 microg/mL was reached 2.27 +/- 0.66 h after an oral dose. The mean AUC(0-12 h) and the elimination half-life (t(1/2)) were 13.2 +/- 4.79 microg h/mL and 3.10 +/- 0.74 h, respectively.  相似文献   

17.
Dehydrodiisoeugenol (DDIE) is a bioactive neolignan from the seeds of Myristica fragrans Houtt., which exhibits good anti-inflammatory activity. A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of DDIE in rat tissues after intravenous administration. The tissue samples were processed by liquid-liquid extraction. The analyses were successfully carried out on a Diamonsiltrade mark ODS C18 column (250 x 4.6 mm i.d., 5 microm) equipped with a C18 guard column (8 x 4.6 mm i.d., 5 microm). The mobile phase was the system of methanol-water (4:1, v/v). The UV detection was set at 270 nm. The calibration curves were linear from 0.4 to 200.0 microg/g with the correlation coefficients (r(2)) greater than 0.998. The intra- and inter-day precisions in quality control samples were less than 10% and the accuracies were in the range 85.4-110.3%. The average recoveries from all the tissues were between 84.4 and 106.0%. This assay method has been successfully used to study the tissues distribution of DDIE in rats after intravenous administration. The result suggests that DDIE is distributed to rat tissues rapidly with possibly greater initial concentrations in liver and brain than in other tissues.  相似文献   

18.
Grapefruit juice inhibits esterase enzyme. Therefore, a possible interaction with ester prodrugs should be taken into consideration. In this study, the influence of grapefruit juice on sacubitril (SAC) rat liver S9 activation by esterase enzyme was evaluated. An RP‐HPLC method was developed and validated for estimation of SAC in rat liver S9 fraction using a C18 Cyano column as stationary phase and acetonitrile–sodium di‐hydrogen phosphate buffer (0.02 m , pH 4 adjusted by o‐phosphoric acid, 40:60, v/v), as mobile phase at a flow rate of 1 mL/min and UV detection at 254 nm. The method was successfully applied to an in vitro study in which SAC was incubated with rat liver S9 fraction prepared from rats that had previously ingested grapefruit juice for a week. The calculated SAC concentration after incubation was compared with that of SAC incubated with rat liver S9 fraction from the rat control group. The statistical significance between the results of test and control incubation sets was assessed. In conclusion, the current study demonstrated that grapefruit juice decreased SAC hydrolysis, hence delaying its activation to sacubitrilat (active form) in gut lumen. Based on this food–drug interaction, it may be required that grapefruit juice should be consumed with caution in patients receiving SAC.  相似文献   

19.
吡罗昔康凝胶有效成分的高效液相色谱研究   总被引:2,自引:0,他引:2  
本文提出了采用内标法 ,将 HPLC用于吡罗昔康凝胶有效成分测定的新方法。讨论了流动相及内标的选择 ,进样量和空白基质的影响等。在优化的实验条件下 ,吡罗昔康浓度在 0 .0 2~ 0 .2 mg/m L范围内 ,其浓度与吡罗昔康和内标的峰面积之比呈线性关系。应用于实际样品分析 ,其结果与紫外分光光度法一致 ,平均回收率为 99.6% ,相对标准偏差为 1 .0 %。方法简单 ,准确度高 ,专属性强 ,可用于吡罗昔康凝胶样品的稳定性考察和质量控制  相似文献   

20.
Phenoprolamine hydrochloride is a novel compound that works against a variety of types of hypertension. The purpose of this study was to develop a simple and sensitive high-performance liquid chromatographic method for quantitation of low phenoprolamine hydrochloride concentrations in human plasma and to apply it to pharmacokinetic study. The procedure involved extraction of the drug and clonidine (internal standard) from the plasma using diethyl ether. Chromatographic separations were carried out on a 4.6 x 200 mm Hypersil silica column with UV detection at 230 nm. The isocratic mobile phase, 1% ammonium acetate (pH 5.4) and methanol (0.3:99.7, v/v), was run at 1 mL/min. Extraction recovery was 84% for phenoprolamine hydrochloride at a concentration level of 200 ng/mL, and 76% for clonidine at 200 ng/mL. The method was linear in the concentration range 5-4000 ng/mL with a lower limit of quantitation of 5 ng/mL for phenoprolamine hydrochloride. Inter- and intra-day coefficients of variation were less than 10%. The validated method was successfully applied to a pharmacokinetic study in human after an oral administration of the drug, and the pharmacokinetic parameters are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号