首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole-linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM-EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)-EPI. MIM-based scanning methods were shown to be particularly useful in several applications. First, MIM-EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM-MRM-EPI was better than MRM-EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM-EPI and full-scan MS (EMS), as an alternative to EMS-EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM-EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole-linear ion trap LC/MS.  相似文献   

2.
The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment.  相似文献   

3.
Polychlorinated biphenyls (PCBs) exist as 209 congeners, consisting of biphenyl molecules, where the number and substitution positions of halogen atoms are known to affect industrial uses, environmental transport mechanisms, distribution, fate, and toxicity. The complexity of the problem requires accurate physicochemical studies of an increasing number of congeners in order to understand the environmental and biological processes at play. This work presents a systematic study on the thermodynamic and kinetic properties of PCBs by quadrupole ion trap mass spectrometry. A clear relationship between structure and behavior of PCBs in mass spectrometry experiments has been observed. Overall data demonstrate that di‐ortho congeners show lower thermodynamic stability and higher fragmentation rate than non/mono‐ortho. Congeners follow different fragmentation mechanisms according to the number of chlorine atoms in ortho position of the biphenyl system. Experimental kinetic curves of mono/non‐ortho and di‐ortho congeners show a strong similarity with classical first‐order kinetics curves; in particular, di‐ortho congeners follow a first‐order consecutive reaction, while mono/non‐ortho follow a first‐order parallel reaction. For each studied congener, the kinetic constant of reaction (fragmentation) has been determined. Data support environmental levels and biochemical transformations described in literature. The general picture of the PCB behavior inside a quadrupole ion trap provides the basis for the development of reliable and cost‐effective analytical methods to the determination of ultra‐low level trace of PCB congeners.  相似文献   

4.
The aim of this study was to investigate the fragmentation behavior induced by low‐energy collision‐induced dissociation (LE‐CID) of four selected antioxidants applied in lubricants, by two different types of ion trap mass spectrometers: a three‐dimensional ion trap (3D‐IT) and a linear IT (LIT) Orbitrap MS. Two sterically hindered phenols and two aromatic amines were selected as model compounds representing different antioxidant classes and were characterized by positive‐ion electrospray ionization (ESI) and LE‐CID. Various types of molecular ions (e.g. [M]+?, [M + H]+, [M + NH4]+ or [M + Na]+) were used as precursor ions generating a significant number of structurally relevant product ions. Furthermore, the phenolic compounds were analyzed by negative‐ion ESI. For both IT types applied for fragmentation, the antioxidants exhibited the same unusual LE‐CID behavior: (1) they formed stable radical product ions and (2) C? C bond cleavages of aliphatic substituents were observed and their respective cleavage sites depended on the precursor ion selected. This fragmentation provided information on the type of structural isomer usually not obtainable for branched aliphatic substituents utilizing LE‐CID. Comparing the two instruments, the main benefit of applying the LIT‐Orbitrap was direct access to elemental composition of product ions enabling unambiguous interpretation of fragmentation trees not obtainable by the 3D‐IT device (e.g. loss of isobaric neutrals). It should be emphasized that the types of product ions formed do not depend on the type of IT analyzer applied. For characterizing degradation products of antioxidants, the LIT‐Orbitrap hybrid system, allowing the determination of accurate m/z values for product ions, is the method of choice. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
Phosphorylation of proteins is an important post-translational protein modification in cellular response to environmental change and occurs in both prokaryotes and eukaryotes. Identification of the amino acid on individual proteins that become phosphorylated in response to extracellular stimulus is essential for understanding the mechanisms involved in the intracellular signals that these modifications facilitate. Most protein kinases catalyze the phosphorylation of proteins on serine, threonine or tyrosine. Although tyrosine phosphorylation is often the least abundant of the three major phosphorylation sites, it is important owing to its role in signal pathways. Currently available methods for the identification of phosphorylation sites can often miss low levels of tyrosine phosphorylations. This paper describes a method for the identification of phosphotyrosine-containing peptides using electrospray ionization on an ion trap mass spectrometer. Skimmer-activated collision-induced dissociation (CID) was used to generate the phosphotyrosine immonium ion at m/z 216. This method is gentle enough that the protonated molecule of the intact peptide is still observed. In-trap CID was employed for the verification of the phosphotyrosine immonium ion. Using this technique, low levels of phosphotyrosine-containing peptides can be identified from peptide mixtures separated by nanoflow micro liquid chromatography/mass spectrometry.  相似文献   

6.
A generic and efficient homolog-targeted approach was used to expand screening and detection of target class of sulfonamides and structural analogs, based on a fast single-tube extraction/partitioning-multifunction adsorption cleanup (SEP/MAC) for class-specific fragmentation-dependent acquisition with a liquid chromatography–hybrid triple-quadrupole linear ion trap mass spectrometer (LC–QqLIT). By combining the two-stage process conducted in a single tube as one-pot protocol, the straightforward SEP/MAC procedure was optimized to offer clean extracts with reasonable recovery (71–109% with RSDs < 20%) and decreased matrix interferences (−9 to 19%) of multiresidual sulfonamide extraction from different tissue samples. The novel use of neutral loss scan of 66 Da (NLS) or precursor ion scanning of m/z 108 (PreS) in positive ion mode was found to achieve more comprehensive coverage of protonated molecular ions of a wide array of sulfonamides including N4-acetyl and hydroxylamine metabolites plus their possible dimers. Moreover, the PreS-triggered automatically enhanced product ion spectral acquisition enabled simultaneous screening, profiling and confirmation of an unlimited number of analytes belonging to the sulfonamide class within a single analysis. The validation and application results of the generic SEP/MAC-based LC–QqLIT strategy consistently demonstrated favorable performances with acceptable accuracy (67–116%), precision (RSDs < 25%), and sensitivity (LOQs ≤ 7.5 ng g−1) to meet the acceptance criteria for all the sulfonamide–tissue combinations. Thus, the integration of the matrix-independent SEP/MAC procedure and the multiparameter matching algorithm with the unit-resolution LC–QqLIT instrument can serve as a valuable semi-targeted discovery strategy for rapid screening and reliable quantitative/confirmatory analysis of real samples.  相似文献   

7.
采用超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱法同时测定化妆品中磺胺类、沙星类等66种抗生素类化合物,建立了快速筛查数据库和定量分析方法。待测物用乙腈超声提取,C18色谱柱(100 mm×2.1 mm,1.8 μm)分离,以0.1%(v/v)甲酸水溶液和乙腈为流动相进行梯度洗脱。在正离子模式下,以保留时间和一级母离子精确质量数进行快速筛查,以高能碰撞诱导解离获得的二级碎片离子精确质量数进行确证。结果表明,化合物的线性关系良好,线性相关系数(R2)>0.99;检出限(LOD)为2~4 μg/kg;定量限(LOQ)为5~10 μg/kg;3个添加水平(1LOQ、10LOQ、30LOQ)的平均回收率为58.2%~119.1%,相对标准偏差为1.03~11.9%。该方法简便快速、定性定量可靠,适用于化妆品中抗生素类化合物的快速筛查和定量检测。  相似文献   

8.
Chemical mass shifts were measured in a Paul ion trap operated in the mass-selective instability scan with resonance ejection using a custom-built instrument. These shifts, which can be as much as 2%, decrease with increasing endcap electrode separation owing to changes in the higher order contributions to the electric field. They also decrease with decreasing helium buffer gas pressure. Both of these effects are analogous to those found with boundary ejection. This suggests that the previously proposed chemical mass shift mechanism based on compound-dependent collisional modification of the ejection delay produced by field faults near the endcap electrode apertures holds true also for resonance ejection. The influence of the resonance frequency on chemical mass shifts was also investigated and it is shown that at certain working points (values of the Mathieu parameter q(z) and a(z)) non-linear resonances greatly reduce the ejection delay for all ions, regardless of their chemical structures, and thus reduce the magnitude of the chemical mass shift. Energetic collisions leading to dissociation can take place at an earlier stage during the ejection process in the mass analysis scan when using resonance ejection compared with boundary ejection. This leads to even larger chemical mass shifts of fragile ions in resonance ejection. Increasing the resonance voltage amplitude can enhance this effect. The chemical mass shifts of fragile ions increase with increase in the resonance voltage amplitude, whereas negligible changes occur for structurally stable ions.  相似文献   

9.
王畅  谢四刚  杨军  杨青  许国旺 《色谱》2004,22(4):316-321
As an important constituent in the biomembranes, phospholipids (PL) are a complex mixture of molecular species containing a variety of fatty acyl and head group compositions. In addition to their structural role, some phospholipids also participate in biological processes in various  相似文献   

10.
The fragmentation of fragile ions during the application of an isolation waveform for precursor ion selection and the resulting loss of isolated ion intensity is well‐known in ion trap mass spectrometry (ITMS). To obtain adequate ion intensity in the selected reaction monitoring (SRM) of fragile precursor ions, a wider ion isolation width is required. However, the increased isolation width significantly diminishes the selectivity of the channels chosen for SRM, which is a serious problem for samples with complex matrices. The sensitive and selective quantification of many lipid molecules, including ceramides from real biological samples, using a linear ion trap mass spectrometer is also hindered by the same problem because of the ease of water loss from protonated ceramide ions. In this study, a method for the reliable quantification of ceramides using SRM with near unity precursor ion isolation has been developed for ITMS by utilizing alternative precursor ions generated by in‐source dissociation. The selected precursor ions allow the isolation of ions with unit mass width and the selective analysis of ceramides using SRM with negligible loss of sensitivity. The quantification of C18:0‐, C24:0‐ and C24:1‐ceramides using the present method shows excellent linearity over the concentration ranges from 6 to 100, 25 to 1000 and 25 to 1000 nM, respectively. The limits of detection of C18:0‐, C24:0‐ and C24:1‐ceramides were 0.25, 0.25 and 5 fmol, respectively. The developed method was successfully applied to quantify ceramides in fetal bovine serum. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
The ring opening of 1,3-di-tert-butylaziridinone by tert-butylamine and aniline was investigated by using electrospray ionization and collision-induced dissociation in an ion trap mass spectrometer in conjunction with (15)N labeling of the two amine nucleophiles. Using the MS(n) capabilities of the ion trap instrument, we were able to monitor the retention of the (15)N label through successive fragmentation steps. Both amines exhibited a remarkable degree of selectivity in that they both cleaved exclusively the 1,3-bond (the alkyl-nitrogen bond). This result is in contrast to that obtained previously with methylamine, which cleaved just the opposite bond, namely, the 1,2-bond (the acyl-nitrogen bond). These contrasting results could not have been predicted by previously published guidelines.  相似文献   

12.
熊陈思慧  定天明  刘杰  易鸥  丁晓萍  谢云 《色谱》2022,40(9):817-824
建立了超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱法同时测定化妆品中的22种功效成分。样品采用甲醇超声提取,C18色谱柱(100 mm×2.1 mm,1.8μm)分离,以0.1%(v/v)甲酸水溶液和乙腈为流动相进行梯度洗脱。在正离子模式下,以保留时间和一级母离子精确质量数进行定量分析,以高能碰撞诱导解离获得的二级碎片离子精确质量数进行确证。结果表明,该方法线性关系良好,检出限(LOD)为0.003~2.01 mg/kg;定量限(LOQ)为0.02~4.36 mg/kg;水、乳、霜3种基质中3个添加水平的回收率范围为63.2%~125.1%,相对标准偏差为0.18%~10.9%。对标示含有烟酰胺、抗坏血酸葡糖苷、咖啡因、泛醇及甘草类(光果甘草根茎叶、甘草根、胀果甘草根)、麦冬根、人参根、黄芪根、虎杖根、苦参根、地黄根、积雪草、茶叶提取物的54批样品进行检测,标示单体功效成分的样品均有检出,标示不同植物提取物的46批样品中,24批检出植物提取物的功效成分。该方法简便快速、定性定量可靠,适用于化妆品中22种功效成分的定量测定。  相似文献   

13.
Recently, linear ion traps (LITs) have been combined with quadrupole (Q), time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). LITs can be used either as ion accumulation devices or as commercially available, stand-alone mass spectrometers with MSn capabilities. The combination of triple quadrupole MS with LIT technology in the form of an instrument of configuration QqLIT, using axial ejection, is particularly interesting, because this instrument retains the classical triple quadrupole scan functions such as selected reaction monitoring (SRM), product ion (PI), neutral loss (NL) and precursor ion (PC) while also providing access to sensitive ion trap experiments. For small molecules, quantitative and qualitative analysis can be performed using the same instrument. In addition, for peptide analysis, the enhanced multiply charged (EMC) scan allows an increase in selectivity, while the time-delayed fragmentation (TDF) scan provides additional structural information. Various methods of operating the hybrid instrument are described for the case of the commercial Q TRAP (AB/MDS Sciex) and applications to drug metabolism analysis, quantitative confirmatory analysis, peptides analysis and automated nanoelectrospray (ESI-chip-MS) analysis are discussed.  相似文献   

14.
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided.  相似文献   

15.
Imatinib (Gleevec) is an anticancer drug that inhibits specific protein kinases involved in cell proliferation. Whereas this drug is considered to have opened a new era, various mechanisms of resistance have been associated with imatinib relapse. Drug disposition in cancer cells including influx, efflux and drug metabolism is one mechanism that remains to be more thoroughly investigated. Moreover, recent genomic studies have revealed that some isozymes of cytochrome P450 (CYP) are possibly associated with the treatment outcome. Therefore, this research paper investigates the role of the activity of CYP1A1, 1A2, 1B1, 3A4, 4F2 and 4F3A/B on the fate of imatinib. First, a study of imatinib fragmentation was effected using electrospray triple-quadrupole and linear ion trap tandem mass spectrometers (MSn). Accurate mass determinations were performed at enhanced mass resolution for the identification of some product ions that were not predicted by two fragmentation softwares. Whereas the quadrupole MS was not designed for accurate mass measurement, delta mass errors were below 20 ppm. Then, a biotransformation study was effected in vitro. Imatinib metabolites were produced in microsomal incubations containing CYP isozymes. Imatinib and metabolites were extracted from incubation mixtures by protein precipitation, and supernatants were injected into a liquid chromatography equipment coupled with MS(n). Hydrophobic interaction liquid chromatography resolved one demethylated-, two hydroxy- and three N-oxide metabolites. Various rates of metabolite formation were observed between CYP isozymes. Liquid chromatography with deuterium oxide-containing mobile phase (H/D exchange) or incorporation of (18)O from H(2) (18)O added in the incubations was performed to elucidate the metabolite structure. Various MS(n) product scans (n < or = 4) were acquired on the linear ion trap or on the triple-quadrupole MS. Postulated structures of new metabolites are addressed.  相似文献   

16.
Complexation by transition metal ions (CuII and FeII) was successfully used to differentiate the diastereomeric YAGFL, YDAGFL and Y(D)AGF(D)L pentapeptides by electrospray ionization-ion trap mass spectrometry in the positive ion mode using low-energy collision conditions. This distinction was allowed by the stereochemical effects due to the (D)Leu/(L)Leu and the (D)Ala/(L)Ala residues yielding various steric interactions which direct relative dissociation rate constants of the binary [(M - H) + MeII]+ complexes (Me = Cu or Fe) subjected to low-energy, collision-induced dissociation processes. The interpretation of the collision-induced dissociation spectra obtained from the diastereomeric cationized peptides allowed the location of the deprotonated site(s), leading to the postulation of ion structures and fragmentation pathways for both the [(M - H) + CuII]+ and [(M - H) + FeII]+ complexes, which differed significantly. With CuII, consecutive fragmentations, initiated by the decarboxylation at C-terminus, were favored relative to sequence product ions. On the other hand, with FeII, competitive fragmentations resulting in abundant sequence product ions and significant internal losses were preferred. This could be explained by different localizations of the negative charge, which directs the orientation of both the [(M - H) + CuII]+ and [(M - H) + FeII]+ binary complexes fragmentations. Indeed, the free negative charge of the [(M - H) + CuII]+ ions was mainly located at one oxygen atom: either at the C-terminal carboxylic group or, to a minor extent, at the Tyr phenol group (i.e. zwitterionic forms). On the other hand, the negative charge of the [(M - H) + FeII]+ ions was mainly located at one of the nitrogen atoms of the peptide backbone and coordinated to FeII (i.e. salt non-zwitterionic form).Moreover, this study reveals the particular behavior of CuII reduced to CuI, which promotes radical losses not observed from the peptide-FeII complexes. Finally, this study shows the analytical potentialities of the complexation of transition metal ions with peptides providing structural information complementary to that obtained from low-energy, collision-induced dissociation processes of protonated or deprotonated peptides.  相似文献   

17.
随着质谱技术的不断发展,对超高质量颗粒物质的分析已经成为质谱领域研究的一个重要方向.离子阱颗粒质谱(particle ion trap mass spectrometry)作为用于完整颗粒质量分析的有利工具,拓展了质谱技术在巨大颗粒物质量分析中的应用范围.本文对离子阱颗粒质谱仪器的研究进展及其在各个领域的应用进行了综述,并展望了离子阱颗粒质谱未来的发展趋势.  相似文献   

18.
Coupled liquid chromatography and ion trap mass spectrometry (LC/MS) was used for the characterization of the semi-synthetic 16-membered ring macrolide josamycin propionate. On-line identification of impurities in this antibiotic complex was performed with an ion trap mass spectrometer without recourse to time-consuming isolation and purification procedures. Ion trap mass spectrometry is ideally suited to identification of impurities because it provides MSn capability, enabling multiple stages of mass spectrometry to obtain the maximum amount of structural information for a given molecule. The ion trap was used with an electrospray ionization source operated in the positive ion mode or with an atmospheric pressure chemical ionization source operated in the negative ion mode. The identity of the unknown compounds was deduced using the MS/MS and MSn collision-induced dissociation spectra of reference substances or structural analogs as interpretative templates, combined with knowledge about the nature of functional group fragmentation behavior. Given the importance attached to the identification of impurities of unknown identity in pharmaceutical substances, this study is useful for companies producing josamycin propionate. The knowledge of the fragmentation behavior is also of importance in further research on other 16-membered macrolides.  相似文献   

19.
Characterization of glycosaminoglycans poses a challenge for current analytical techniques, as they are highly acidic, polydisperse and heterogeneous compounds. The purpose of this study is the separation and analysis of a partially depolymerized heparin-like glycosaminoglycan by on-line ion-pairing reversed-phase high-performance liquid chromatography/electrospray mass spectrometry. The gas-phase behavior of two synthesized glycosaminoglycans has been investigated. Dibutylamine was found to be the best suited ion-pairing reagents for mass spectrometry analysis. The optimized ion-pairing conditions provide reproducible and easily interpretable electrospray mass spectra in both negative and positive ESI modes. The glycosaminoglycans are detected as a non-covalent complex with amines. In fact, the observed ionic species and their gas-phase dissociation under CID conditions revealed the presence of salt bridge interactions in the gas phase.  相似文献   

20.
牛增元  罗忻  叶曦雯  修晓丽  张丽  王新  陈静 《色谱》2015,33(10):1104-1109
建立了基于高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(HPLC-LTQ/Orbitrap MS)快速筛查确证生态纺织品中22种禁用分散染料的分析方法。样品在95 ℃水浴条件下经吡啶/水(1:1, v/v)振荡提取后,以CAPCELL PAK C18色谱柱分离,以乙腈和5 mmol/L乙酸铵(含体积分数为0.01%的甲酸)作为色谱流动相进行梯度洗脱,采用正、负电喷雾(ESI)离子化模式,利用一级母离子的精确质量数和保留时间对22种分散染料进行快速筛查,利用碰撞诱导解离(CID)下得到的二级碎片离子进行确证。22种分散染料在各自浓度范围内线性关系良好(r2> 0.99),方法的定量限(LOQ)为0.125~2.5 mg/kg。除分散黄49外,绝大多数染料在涤纶布、棉涤混纺布两种纺织品基质中的加标回收率在65%~120%之间,相对标准偏差小于15%。应用本方法对涉及多种纤维类型的40余件纺织品样品进行了筛查,其中一个样品检出分散橙37/76。该方法简便、快速,其选择性高,抗干扰性能好,结果准确可靠,可用于纺织品中分散染料的检测。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号