采用封闭酸溶电感耦合等离子体质谱(ICP-MS)法测定岩石样品,分别对47种元素的测量结果不确定度进行评定。通过分析测试方法和测量条件,得到测量结果的不确定度主要由样品称量、样品溶液定容和样品溶液中元素浓度测量引入。在实验室质控条件下,对各不确定度分量进行评定和计算,其中随机因素导致的不确定度采用期间精密度试验综合评价,即采用A类方法评定。共完成了16个岩石国家标准物质(GBW 07103~GBW 07123)47种元素测量结果的不确定度合成,并参照GB/T 6379.2-2004,建立了含量w与扩展不确定度U之间的关系模型,运用这一关系模型可得到测量结果的不确定度估计值,只要测量过程本身或所使用的设备未变化,就不需要再重复进行不确定度评估。  相似文献   

2.
建立电感耦合等离子体质谱法测定三水铝土矿中15种有效稀土元素的分析方法。参考三水铝土矿中有效铝的概念,提出了有效稀土元素的概念,并对三水铝土矿中稀土元素的回收利用的可行性进行了评价。模拟低温拜耳法生产氧化铝的工艺,对三水铝土矿中稀土元素溶出过程中的氢氧化钠浓度、溶出温度及时间等条件进行了试验,采用90 g/L氢氧化钠结合微波消解技术对三水铝土矿进行分解,用ICP-MS法测定有效稀土元素,有效稀土元素测定结果的相对标准偏差为0.92%~7.40%(n=7),回收率为98.6%~101.2%。该方法可用于测定三水铝土矿中有效稀土元素,能够对三水铝土矿中稀土元素的回收利用价值进行评价。  相似文献   

3.
A quadrupole inductively coupled plasma mass spectrometer was evaluated for use in the detection of phosphorus. The influences of nitric acid and methanol (simulating the composition of a sample solution after nitric acid digestion) on phosphorus determination were studied using two different measuring methods at different plasma conditions: detection of phosphorus ions at m/z 31 and detection of phosphorus oxide ions at m/z 47. The existence of polyatomic interferences at m/z 31 and 47 was explored. Nitric acid and methanol are shown to be the sources of polyatomic ions and therefore cause poorer detection limits. Better detection limits were achieved in such matrices when phosphorus was detected as 31P+. The presence of methanol improves the system sensitivity towards phosphorus sevenfold; however, this positive effect is hindered by the high background signal due to carbon-based polyatomic ions. For samples with an organic matrix an appropriate mineralization procedure should be applied (high excess of nitric acid and high temperature) to quantitatively oxidize organic compounds to carbon dioxide, which is easily removed from the sample, in order to achieve correct results.  相似文献   

4.
采用微波消解前处理方法,结合电感耦合等离子体质谱技术,建立了板栗中钠(Na)、钾(K)、镁(Mg)、锰(Mn)、铁(Fe)、钒(V)、钴(Co)等19种矿物元素及镧(La)、铈(Ce)、镨(Pr)、钕(Nd)、钐(Sm)、铕(Eu)、钆(Gd)、铽(Tb)、镝(Dy)、钬(Ho)、铒(Er)、铥(Tm)、镱(Yb)、镥(Lu)、钇(Y)等15种稀土元素的同时分析测定方法。该方法检出限为0.0027~0.78μg?L-1,相对标准偏差为1.4%~6.3%。通过国家标准物质GBW10019苹果的准确率实验验证,测定结果均在标准证书值范围内。实验结果表明,该方法适用于板栗中矿物元素及稀土元素的同时测定。  相似文献   

5.
建立电感耦合等离子体质谱法测定手机壳套中14种可迁移元素含量的方法。样品经人工模拟汗液溶液振荡处理,使14种特定元素迁移至模拟溶液中,然后进行微波消解,采用电感耦合等离子体质谱法对消解液进行测定。14种元素在各自的质量浓度范围内具有良好的线性关系,相关系数均大于0.999,方法检出限为0.004~0.400μg/L。样品加标回收率为88.2%~99.5%,测定结果的相对标准偏差为2.5%~9.3%(n=5)。该方法操作简便,灵敏度高,线性范围广,定量准确,适用于手机壳套中14种可迁移元素含量的测定。  相似文献   

6.
On‐line coupling of LC and ICP‐MS has been used for fractionation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been shown that anion exchange chromatography provided better separation capability (both intra‐ and inter‐element) than size‐exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris–HNO3 buffer and ammonium salt (nitrate, acetate or formate). Formate was found to be the best mobile phase counter ion, enabling good chromatographic separation, and is acceptable for mass spectrometry too. The quantitative evaluation of element concentrations adhering to individual fractions was performed by the peak area normalization method. The repeatability of results ranged from 3 to 15% (depending on the element concentration level) and represented the main part of the result uncertainty. The accuracy of Cu and Zn fraction determinations was confirmed by comparison with the isotope dilution technique. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

7.
为快速、准确测定韭菜中多元素含量,采用微波消解法对韭菜中样品进行消解处理,优化了前处理方法、ICP-MS工作条件和检测方法,利用微波消解-电感耦合等离子体质谱法测定韭菜中Pb、Cd、Se、As、Zn、Cu、Ni、Fe、Cr、Ca、K等11种元素含量。结果表明,在硝酸-双氧水(7:1)体系中,消解功率1550W,温度梯度为120℃-160℃-195℃,总时长为45min,赶酸温度选择150℃,可将韭菜完全消解,并且ICP-MS射频功率设为1550W,运用在线内标的检测方式降低非质谱干扰。11种元素回归系数R2均大于0.999,方法检出限为0.002~0.100μg/kg,方法定量限为0.006~0.300μg/kg。方法回收率88.0%~102.7%,相对标准偏差为1.8%~4.6%,可以满足韭菜中多种元素同时测定的需求。方法具有灵敏度高、线性范围宽、准确性高等特点,可为韭菜样品的多元素同时测定提供可靠的方法支撑。  相似文献   

8.
Matrix effects in inductively coupled plasma mass spectrometry: a review   总被引:2,自引:0,他引:2  
Fundamental research on non-spectroscopic interferences, also known as matrix effects, in inductively coupled plasma (ICP) mass spectrometry with sample introduction using nebulization is critically and exclusively examined in this review, starting with fundamental processes that may be a source of matrix effects during sample introduction, ion generation in the ICP, ion extraction through the interface, and ion transport through the ion optics to the detector. Various methods for attenuating matrix effects are then reviewed and illustrated with some examples. Instead of exhaustively reviewing the literature, representative references are used to comprehensively describe the main issues, several of which are also common to ICP optical emission spectrometry.  相似文献   

9.
电感耦合等离子体质谱法测定花生中34种元素   总被引:3,自引:0,他引:3  
建立了微波消解-碰撞/反应池(ORS)电感耦合等离子体质谱仪(ICP-MS)同时测定花生中的Na、Mg、Ca、Fe、Se、Mo和稀土元素等34种元素的分析方法。样品经微波消解后,在线加入内标元素45Sc、72Ge、103Rh、115In和209Bi消除基体效应,应用碰撞反应池技术,以4.5 mL/min流速的氦气作为碰撞反应气,有效消除多原子离子产生的质谱干扰。各元素的检出限为0.0003~17.37ng/mL,相对标准偏差(RSD)低于2.9%;标准物质的测定值均在标准值范围内,结果令人满意。该方法可用于花生中多种元素的同时测定。  相似文献   

10.
利用电感耦合等离子体原子发射光谱仪( ICP-AES)建立白云石和菱镁石中铝、钙、铁、镁、锰、磷、硅、锶的测定方法。研究了酸体系、温度及消解方式对试样消解的影响,结果表明,使用5 mL盐酸和硝酸混合酸(1:3)-0.75 mL氢氟酸-5 mL水以密闭消解的方式在150 ℃下消解白云石和菱镁石30min,并以2mL饱和硼酸络合多余的氢氟酸,可以得到澄清消解液。通过白云石和菱镁石中铝、钙、铁、镁、锰、磷、硅、锶的谱线干扰情况,选择Al 308.215 nm、Ca 318.127 nm、Fe 261.187 nm、Mg 277.983 nm、Mn 257.61 nm、P 213.618 nm、Si 251.611 nm、Sr 421.552 nm作为分析线,各元素的校准曲线在线性范围内线性关系良好,相关系数均不小于0.999。按照实验方法测定白云石和菱镁石标准物质,各元素结果的相对标准偏差 (RSD, n=6)为0.89~3.19%,测定值与认定值无显著性差异。本方法有效解决了白云石和菱镁石快速有效溶解及准确测定问题。  相似文献   

11.
采用电感耦合等离子体质谱(ICP-MS)法测定镍基高温合金中磷杂质含量,对该测定方法的不确定度进行评定。建立了不确定度评定的数学模型,对不确定度的来源进行了全面分析,通过计算得到扩展不确定度。采用ICP-MS法测定YSBC 41503-2012标准物质中的磷含量,测定值为0.0035%,测定结果与证书参考值一致。按照建立的不确定度评定方法得扩展不确定度为0.0002%(k=2)。该方法适用于ICP-MS法测定高温合金中磷含量的不确定度评定。  相似文献   

12.
金绿宝石结构稳定,常规敞开酸溶、密闭酸溶、微波消解三种前处理方法并不能将其完全分解,测定结果偏低。本文采用碳酸钠-硼酸混合熔剂进行熔融,样品分解完全,建立了电感耦合等离子体质谱法(ICP-MS)测定金绿宝石中16种痕量稀土元素的分析方法。选择丰度高、干扰小的同位素、动能歧视碰撞池(KED)模式及干扰系数校正法消除质谱干扰,以185Re为内标元素及样品稀释降低基体干扰。实验表明:各稀土元素的校准曲线相关系数r值在0.9991~0.9998之间,方法检出限为0.0001~0.0134 μg/g,定量限为0.0005~0.0670 μg/g。采用国家标准物质GBW07151验证方法的精密度,计算出相对标准偏差(RSD, n=7)在1.3%~4.6%之间,并将此方法用于金绿宝石实际样品中稀土元素的测定,RSD为0.9%~3.2%,加标回收率为94%~104%,符合国家地质矿产行业标准,结果稳定、可靠。  相似文献   

13.
碘是活跃元素,价态多,各价态间易相互转化,使其具有熔点低、易挥发,严重记忆效应的独特性质,其分析一直是个挑战。传统方法如半熔法、高压密闭法等存在操作难度大、消解时间长、工作效率低等问题。通过采用硝酸-氢氟酸微波消解处理样品,并利用电感耦合等离子体质谱(ICP-MS)法测定碘含量,克服了传统碘分析方法的一列问题。研究了不同酸体系和赶酸时间对样品分解效率和挥发损失的影响,同时验证了不同冲洗液对降低碘记忆效应的效果。在此基础上,确定了最佳反应条件为7 mL硝酸 +1 mL氢氟酸混合酸比例,180 ℃赶酸控温程序,并采用2% NH3·H2O充当冲洗液,降低了ICP-MS测定过程中的记忆效应,提高测试的稳定性。为验证该方法的准确性和精密度,使用国家一级标准物质进行方法验证。结果表明,方法的准确度(?lgc)为0.001~0.004,相对标准偏差(RSD)为1.2%~3.4%,相关系数为0.999 8,检出限为0.17 mg/kg,定量限为0.54 mg/kg,表现出较好的准确度和精密度,满足规范要求。通过实际样品测试,进一步验证了该方法的可行性,实验结果表明相对偏差在1.6%~4.1%。该方法操作方便、试剂用量少、工作效率高,适用于测定黑土地地表基质调查样品,同时也为碘的快速、准确分析提供了一种可行的解决方案。  相似文献   

14.
A method has been developed for the simultaneous quantification of major to ultratrace elements in geological samples using quadrupole ICP-MS techniques. The sample preparation involves fusion with LiBO2 and dilution in HNO3-HF which allows complete decomposition of refractory minerals and quantification of the elements of interest. The effects of high Total Dissolved Solids (TDS) and Li in the solution are minimized using a matrix-tolerant interface and conditioning the instrument with LiBO2 solution. The signal drift is moreover controlled using conventional internal standards and specific Drift Correction Standards (DCS). A key issue of the technique is the external calibration using selected Certified Reference Materials (CRM). Depending on the sample type and analytes of interest three optimized programmable modes are used sequentially: Standard, Collision Cell (CCT) and Kinetic Energy Discrimination (KED) mode. The method allows to quantify more than 40 elements in concentrations from tens-of-percent to <0.1 ppm levels during a single experiment. The method has been validated through the analysis of different CRMs with recovery factors of ca. 100% and typical 2σ errors of <10%.  相似文献   

15.
The accurate analytical method of bromine (Br) in plastic was developed by an isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). The figures of merit of microwave acid digestion procedures using polytetrafluoroethylene (PTFE) or quartz vessels were studied and the latter one was suitable for Br analysis since its material was free from Br contamination. The sample dilution procedures using Milli-Q water or ammonium (NH3) solution were also studied to remove memory effect for ICPMS measurement. Although severe memory effect was observed on Milli-Q water dilution, NH3 solution could remove it successfully. The accuracy of the ID-ICPMS was validated by a certified reference material (CRM) as well as the comparison with the analytical result obtained by an instrumental neutron activation analysis (INAA) as different analytical method. From these results, the ID-ICPMS developed in the present study could be evaluated as accurate analytical method of Br in plastic materials and it could apply to certification of Br in candidate plastic CRM with respect to such regulations related to RoHS (restriction of the use of hazardous substances in electrical and electronics equipment) directive.  相似文献   

16.
This work describes an arsenic speciation analysis in aqueous effluent from a shale industrial plant using liquid chromatography coupled to inductively coupled plasma mass spectrometry (LC–ICP–MS). Arsenic species have been separated through an anion-exchange column and several parameters investigated, such as retention time, pH, flow rate and concentration of the mobile phase (ammonium carbonate), chloride interference and column conditioning time. The best conditions have been found by fixing the pH of the mobile phase at 8.7. Keeping the mobile phase flow rate at 1.5 ml min− 1, arsenic species were separated by varying the concentration of the mobile phase and the time of elution, as follow: 1.5 mmol l− 1 for 10 min, 12 mmol l− 1 for 10 min and 20 mmol l− 1 for 10 min, respectively. Up to 13 As species present in the samples were separated under these conditions and the following species could be identified and quantified: arsenite [As(III)], dimethylarsinic acid (DMA), monomethylarsonic acid (MMA) and arsenate [As(V)]. The limits of detection of the LC–ICP–MS method were 0.02, 0.06, 0.04 and 0.10 μg l− 1 of As(III), DMA, MMA, and As(V), respectively. The concentration of these species in the samples were from 3.7 to 6.4 μg l− 1, 6.9 to 13.2 μg l− 1, 100 to 142 μg l− 1 and 808 to 1363 μg l− 1 for As(III), DMA, MMA and As(V), respectively. The accuracy, evaluated by recovery tests, varied from 94 to 105% and the precision, evaluated by the relative standard deviation was typically lower than 10%.  相似文献   

17.
Simultaneous and multi-elemental method was optimized to determine 35 elements in 274 coarse and fine aerosol samples by using HR-ICP-MS. The procedures were validated. Measurement uncertainties of all elements including sampling uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each element ranged between 79% and 129% using NIST SRM 1648, urban dust. The calculated uncertainties of the analytical methods were between 2.9% and 18% for both sample types. The major contributions to the uncertainty budget come from the calibration curves, repeatability and volume of air.  相似文献   

18.
This paper describes a simple procedure for the direct analysis and determination of multiple elements in dried blood samples on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). With this technique, we simultaneously quantified 13 elements in whole blood: Be, Mn, Co, Ni, Tl, Bi, Sb, Pb, Cu, Zn, Ba, Mg, and Cd. The measured accuracies was in agreement with the Seronorm CRM certified values, except for Mn, Zn, Ba and Cd, which presented absolute differences higher than the expanded uncertainty for these elements. The within-run precision was less than 5.7% (relative standard deviation, RSD), except for the analyses of Be, and Mn (8.6% and 11.1%, respectively). The reproducibility (between-run precision) was calculated in terms of the RSD obtained for 12 analyses (i.e., four replicates of each sample in three analytical runs). Apart from Be, Mn, and Zn, the reproducibilities of all the elements listed above ranged between 4.0% and 8.5%. In contrast, for Cd, the concentration obtained was significantly different from the certified value; analyses of this element exhibited low reproducibility. Applying the matrix-matched calibration method, the accuracy for Cd measured was in agreement with both SRM966 and BCR 635; thus, matrix-matched calibration is a practical means of overcoming matrix-enhancement effects for the quantification of Cd. Sample throughput (ca. 5 min per sample) made it possible to rapidly screen a larger number of samples relative to other techniques that require time-consuming sample preparation steps (e.g., removal of a portion of the solid sample or digestion).  相似文献   

19.
陈璐 《化学分析计量》2020,29(2):98-101
建立电感耦合等离子体质谱法同时测定地质样品中镉、锗、钴含量的分析方法。样品用氢氟酸-硝酸混合溶液加热溶解,然后加热浓缩驱酸,再用硝酸溶液(1+1)复溶提取,在选定的仪器工作条件下进行测定。镉、锗、钴的含量分别在0.00~0.10,0.00~5.00,0.00~50.00 μg/g范围内与质谱峰强度呈良好的线性关系,相关系数均大于0.999,方法检出限分别为0.01,0.02,0.02 μg/g。用该方法对国家一级标准物质进行测定,测定值的相对误差均小于10%,测定结果的相对标准偏差为0.79%~8.45%(n=12)。该方法样品处理过程简便,检测效率高,适用于批量地质样品中镉、锗、钴的测定。  相似文献   

20.
Coedo AG  Padilla I  Dorado MT 《Talanta》2005,67(1):136-143
Element determination in solid waste products from the steel industry usually involves the time-consuming step of preparing a solution of the solid. Laser ablation (LA) inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the analysis of Cr, Ni, Cu, As, Cd and Sn, elements of importance from the point of view of their impact on the environment, in electric arc furnace flue dust (EAFD). A simple method of sample preparation as pressed pellets using a mixture of cellulose and paraffin as binder material was applied. Calibration standards were prepared spiking multielement solution standards to a 1:1 ZnO + Fe2O3 synthetic matrix. The wet powder was dried and mechanically homogenised. Quantitative analysis were based on external calibration using a set of matrix matched calibration standards with Rh as a internal standard. Results obtained using only one-point for calibration without matrix matched, needing less time for standardization and data processing, are also presented. Data are calculated for flue dust reference materials: CRM 876-1 (EAFD), AG-6203 (EAFD), AG-6201 (cupola dust) and AG-SX3705 (coke ashes), and for two representative electrical arc furnace flue dusts samples from Spanish steelmaking companies: MS-1 and MS-2. For the reference materials, an acceptable agreement with certificate values was achieved, and the results for the MS samples matched with those obtained from conventional nebulization solutions (CN). The analytical precision was found to be better than 7% R.S.D. both within a single pellet and between several pellets of the same sample for all the elements.  相似文献   