首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Today, immunoassays and several chromatographic methods are in use for drug screening in clinical and forensic toxicology and in doping control. For further proof of the authors’ new metabolite-based liquid chromatography-mass spectrometry (LC-MSn) screening concept, the detectability of drugs of abuse and their metabolites using this screening approach was studied. As previously reported, the corresponding reference library was built up with MS2 and MS3 wideband spectra using a LXQ linear ion trap with electrospray ionization in the positive mode and full scan information-dependent acquisition. In addition to the parent drug spectra recorded in methanolic solution, metabolite spectra were identified after protein precipitation of urine from rats after administration of the corresponding drugs and added to the library. This consists now of data of over 900 parent compounds, including 87 drugs of abuse, and of over 2,300 metabolites and artifacts, among them 436 of drugs of abuse. Recovery, process efficiency, matrix effects, and limits of detection for selected drugs of abuse were determined using spiked human urine, and the resulting data have been acceptable. Using two automatic data evaluation tools (ToxID and SmileMS), the intake of 54 of the studied drugs of abuse could be confirmed in urine samples of drug users after protein precipitation and LC separation. The following drugs classes were covered: stimulants, designer drugs, hallucinogens, (synthetic) cannabinoids, opioids, and selected benzodiazepines. The presented LC-MSn method complements the well-established gas chromatography-mass spectroscopy procedure in the authors’ laboratory.  相似文献   

2.
In clinical toxicology, fast and specific methods are necessary for the screening of different classes of drugs. Therefore, an online extraction high-performance liquid chromatography coupled to mass spectrometry (LC-MSn) screening method using a MS2 and MS3 spectral library for the identification of xenobiotic substances has been developed and validated. Samples were run twice, once native and once after enzymatic hydrolysis. Internal standards and buffer were added to the urine samples. Following centrifugation, the supernatant was injected into the system. Extraction was performed by online turbulent flow chromatography. The chromatographic separation was achieved using a Phenyl/Hexyl column. For detection, a linear ion trap, equipped with an APCI interface, was used and the different compounds were identified using a MS2 and MS3 spectral library containing 356 compounds. The turnaround time to report the results of the screening including hydrolysis was approximately 2 h. About 92% of the 356 substances could be identified with a limit of identification below 100 ng/ml. The recovery and matrix effect experiments showed suitable results, and in six drug-free urine samples of healthy volunteers analyzed for selectivity, no substances have been identified. Carryover could be well controlled, and the method had a good reproducibility. The comparison of the results of 103 real patient urine samples showed a good agreement between the existing GC-MS and LC-MS methods with offline extraction and the new online extraction LC-MSn screening method. The presented method allows a fast and sensitive analysis of a broad range of compounds.  相似文献   

3.
Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.  相似文献   

4.
Mitragyna speciosa (Kratom) is currently used as a drug of abuse. When monitoring its abuse in urine, several alkaloids and their metabolites must be considered. In former studies, mitragynine (MG), its diastereomer speciogynine (SG), and paynantheine and their metabolites could be identified in rat and human urine using LC-MSn. In Kratom users' urines, besides MG and SG, further isomeric compounds were detected. To elucidate whether the MG and SG diastereomer speciociliatine (SC) and its metabolites represent further compounds, the phase I and II metabolites of SC were identified first in rat urine after the administration of the pure alkaloid. Then, the identified rat metabolites were screened for in the urine of Kratom users using the above-mentioned LC-MSn procedure. Considering the mass spectra and retention times, it could be confirmed that SC and its metabolites are so far the unidentified isomers in human urine. In conclusion, SC and its metabolites can be used as further markers for Kratom use, especially by consumption of raw material or products that contain a high amount of fruits of the Malaysian plant M. speciosa.  相似文献   

5.
Tandem mass spectral library searching is finding increased use as an effective means of determining chemical identity in mass spectrometry-based omics studies. We previously reported on constructing a tandem mass spectral library that includes spectra for multiple precursor ions for each analyte. Here we report our method for expanding this library to include MS2 spectra of fragment ions generated during the ionization process (in-source fragment ions) as well as MS3 and MS4 spectra. These can assist the chemical identification process. A simple density-based clustering algorithm was used to cluster all significant precursor ions from MS1 scans for an analyte acquired during an infusion experiment. The MS2 spectra associated with these precursor ions were grouped into the same precursor clusters. Subsequently, a new top-down hierarchical divisive clustering algorithm was developed for clustering the spectra from fragmentation of ions in each precursor cluster, including the MS2 spectra of the original precursors and of the in-source fragments as well as the MSn spectra. This algorithm starts with all the spectra of one precursor in one cluster and then separates them into sub-clusters of similar spectra based on the fragment patterns. Herein, we describe the algorithms and spectral evaluation methods for extending the library. The new library features were demonstrated by searching the high resolution spectra of E. coli extracts against the extended library, allowing identification of compounds and their in-source fragment ions in a manner that was not possible before.
Graphical Abstract ?
  相似文献   

6.
Metabolome analysis of human cerebrospinal fluid (CSF) is challenging because of low abundance of metabolites present in a small volume of sample. We describe and apply a sensitive isotope labeling LC-MS technique for qualitative analysis of the CSF metabolome. After a CSF sample is divided into two aliquots, they are labeled by 13C-dansyl and 12C-dansyl chloride, respectively. The differentially labeled aliquots are then mixed and subjected to LC-MS using Fourier-transform ion cyclotron resonance mass spectrometry (FTICR MS). Dansylation offers significant improvement in the performance of chromatography separation and detection sensitivity. Moreover, peaks detected in the mass spectra can be readily analyzed for ion pair recognition and database search based on accurate mass and/or retention time information. It is shown that about 14,000 features can be detected in a 25-min LC-FTICR MS run of a dansyl-labeled CSF sample, from which about 500 metabolites can be profiled. Results from four CSF samples are compared to gauge the detectability of metabolites by this method. About 261 metabolites are commonly detected in replicate runs of four samples. In total, 1132 unique metabolite ion pairs are detected and 347 pairs (31%) matched with at least one metabolite in the Human Metabolome Database. We also report a dansylation library of 220 standard compounds and, using this library, about 85 metabolites can be positively identified. Among them, 21 metabolites have never been reported to be associated with CSF. These results illustrate that the dansylation LC-FTICR MS method can be used to analyze the CSF metabolome in a more comprehensive manner.  相似文献   

7.
We report here an automated method for the identification of N-oxide functional groups in drug metabolites by using the combination of liquid chromatography/tandem mass spectrometry (LC/MS n ) based on ion-molecule reactions and collision-activated dissociation (CAD). Data-dependent acquisition, which has been readily utilized for metabolite characterization using CAD-based methods, is adapted for use with ion-molecule reaction-based tandem mass spectrometry by careful choice of select experimental parameters. Two different experiments utilizing ion-molecule reactions are demonstrated, data-dependent neutral gain MS3 and data-dependent neutral gain pseudo-MS3, both of which generate functional group selective mass spectral data in a single experiment and facilitate increased throughput in structural elucidation of unknown mixture components. Initial results have been generated by using an LC/MS n method based on ion-molecule reactions developed earlier for the identification of the N-oxide functional group in pharmaceutical samples, a notoriously difficult functional group to identify via CAD alone. Since commercial software and straightforward, external instrument modification are used, these experiments are readily adaptable to the industrial pharmaceutical laboratory.  相似文献   

8.
The behaviour of sulfadiazine (SDZ) and its metabolites was investigated by administering the 14C-labelled veterinary drug to fattening pigs. The excretion kinetics were determined after daily collection of manure. Two known metabolites, N-acetylsulfadiazine and 4-hydroxysulfadiazine, and two hitherto unidentified minor metabolites were recovered. Various mass spectrometric techniques such as parent, product ion scans and accurate mass measurement were used. The new compounds were identified as N-formylsulfadiazine (For-SDZ) and N-acetyl-4-hydroxysulfadiazine (Ac-4-OH-SDZ). The identification of SDZ, Ac-SDZ and For-SDZ was confirmed by comparison of the spectroscopic and chromatographic data of the synthesized authentic references. The identification of the hydroxylated compounds 4-OH-SDZ and Ac-4-OH-SDZ was performed by MSn, and accurate mass measurements. Only 4% of the administered radioactivity remained in the pig after ten days and SDZ accounted for 44% of the 96% radioactivity excreted. More than 93% of the labelled compounds were detected and identified in the manure. The key analytical problem, namely a high concentration of matrix in sample extracts, was overcome by advanced measurement techniques and with the use of a suitable internal standard. The mean recoveries for all compounds were ≥96%. Linearity was established over a concentration range of 0.5 to 10,000 μg kg−1 manure with a correlation coefficient ≥0.99. The same experiment was carried out simultaneously with non-labelled SDZ to obtain manure for outdoor soil experiments.  相似文献   

9.
Detection of drugs in tissue typically requires extensive sample preparation in which the tissue is first homogenized, followed by drug extraction, before the extracts are finally analyzed by LC/MS. Directly analyzing drugs in intact tissue would eliminate any complications introduced by sample pretreatment. A matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS n ) method as been developed for the quantification of cocaine present in postmortem brain tissue of a chronic human cocaine user. It is shown that tandem mass spectrometry (MS2 and MS3) increase selectivity, which is critical for differentiating analyte ions from background ions such as matrix clusters and endogenous compounds found in brain tissue. It is also shown that the use of internal standards corrects for signal variability during quantitative MALDI, which can be caused by inhomogeneous crystal formation, inconsistent sample preparation, and laser shot-to-shot variability. The MALDI-MS n method developed allows for a single MS3 experiment that uses a wide isolation window to isolate both analyte and internal standard target ions. This method is shown to provide improved precision [∼10–20 times reduction in percent relative standard deviation (%RSD)] for quantitative analysis compared to using two alternating MS3 experiments that separately isolate the target analyte and internal standard ions.  相似文献   

10.
Methoxetamine (MXE; 2-(3-methoxyphenyl)-2-(N-ethylamino)-cyclohexanone), a ketamine analog, is a new designer drug and synthesized for its longer lasting and favorable pharmacological effects over ketamine. The aims of the presented study were to identify the phases I and II metabolites of MXE in rat and human urine by GC-MS and LC-high-resolution (HR)-MS n and to evaluate their detectability by GC-MS and LC-MS n using authors’ standard urine screening approaches (SUSAs). Furthermore, human cytochrome P450 (CYP) enzymes were identified to be involved in the initial metabolic steps of MXE in vitro, and respective enzyme kinetic studies using the metabolite formation and substrate depletion approach were conducted. Finally, human urine samples from forensic cases, where the ingestion of MXE was suspected, were analyzed. Eight metabolites were identified in rat and different human urines allowing postulation of the following metabolic pathways: N-deethylation, O-demethylation, hydroxylation, and combinations as well as glucuronidation or sulfation. The enzyme kinetic studies showed that the initial metabolic step in humans, the N-deethylation, was catalyzed by CYP2B6 and CYP3A4. Both SUSAs using GC-MS or LC-MS n allowed monitoring an MXE intake in urine.  相似文献   

11.
12.
2-Methiopropamine [1-(thiophen-2-yl)-2-methylaminopropane, 2-MPA], a thiophene analogue of methamphetamine, is available from online vendors selling “research chemicals.” The first samples were seized by the German police in 2011. As it is a recreational stimulant, its inclusion in routine drug screening protocols should be required. The aims of this study were to identify the phase I and II metabolites of 2-MPA in rat and human urine and to identify the human cytochrome-P450 (CYP) isoenzymes involved in its phase I metabolism. In addition, the detectability of 2-MPA in urine samples using the authors’ well-established gas chromatography–mass spectrometry (GC-MS) and liquid chromatography-linear ion trap-mass spectrometry (LC-MSn) screening protocols was also evaluated. The metabolites were isolated from rat and human urine samples by solid-phase extraction without or following enzymatic cleavage of conjugates. The phase I metabolites, following acetylation, were separated and identified by GC-MS and/or liquid chromatography–high-resolution linear ion trap mass spectrometry (LC-HR-MSn) and the phase II metabolites by LC-HR-MSn. The following major metabolic pathways were proposed: N-demethylation, hydroxylation at the side chain and at the thiophene ring, and combination of these transformations followed by glucuronidation and/or sulfation. CYP1A2, CYP2C19, CYP2D6, and CYP3A4 were identified as the major phase I metabolizing enzymes. They were also involved in the N-demethylation of the analogue methamphetamine and CYP2C19, CYP2D6, and CYP3A4 in its ring hydroxylation. Following the administration of a typical user’s dose, 2-MPA and its metabolites were identified in rat urine using the authors’ GC-MS and the LC-MSn screening approaches. Ingestion of 2-MPA could also be detected by both protocols in an authentic human urine sample.  相似文献   

13.
The opioid 3-methylfentanyl, a designer drug of the fentanyl type, was scheduled by the Controlled Substance Act due to its high potency and abuse potential. To overcome this regulation, isofentanyl, another designer fentanyl, was synthesized in a clandestine laboratory and seized by the German police. The aims of the presented study were to identify the phase I and phase II metabolites of 3-methylfentanyl and isofentanyl in rat urine, to identify the cytochrome P450 (CYP) isoenzymes involved in their initial metabolic steps, and, finally, to test their detectability in urine. Using liquid chromatography (LC)–linear ion trap–mass spectrometry (MSn), nine phase I and five phase II metabolites of 3-methylfentanyl and 11 phase I and four phase II metabolites of isofentanyl could be identified. The following metabolic steps could be postulated for both drugs: N-dealkylation followed by hydroxylation of the alkyl and aryl moiety, hydroxylation of the propanamide side chain followed by oxidation to the corresponding carboxylic acid, and, finally, hydroxylation of the benzyl moiety followed by methylation. In addition, N-oxidation of isofentanyl could also be observed. All hydroxy metabolites were partly excreted as glucuronides. Using recombinant human isoenzymes, CYP2C19, CYP2D6, CYP3A4, and CYP3A5 were found to be involved in the initial metabolic steps. Our LC-MSn screening approach allowed the detection of 0.01 mg/L of 3-methylfentanyl and isofentanyl in spiked urine. However, in urine of rats after the administration of suspected recreational doses, the parent drugs could not be detected, but their common nor metabolite, which should therefore be the target for urine screening.  相似文献   

14.
High sensitivity identification of sulfated glycans carried on specific sites of glycoproteins is an important requisite for investigation of molecular recognition events involved in diverse biological processes. However, aiming for resolving site-specific glycosylation of sulfated glycopeptides by direct LC-MS2 sequencing is technically most challenging. Other than the usual limiting factors such as lower abundance and ionization efficiency compared to analysis of non-glycosylated peptides, confident identification of sulfated glycopeptides among the more abundant non-sulfated glycopeptides requires additional considerations in the selective enrichment and detection strategies. Metal oxide has been applied to enrich phosphopeptides and sialylated glycopeptides, but its use to capture sulfated glycopeptides has not been investigated. Likewise, various complementary MS2 fragmentation modes have yet to be tested against sialylated and non-sialylated sulfoglycopeptides due to limited appropriate sample availability. In this study, we have investigated the feasibility of sequencing tryptic sulfated N-glycopeptide and its MS2 fragmentation characteristics by first optimizing the enrichment methods to allow efficient LC-MS detection and MS2 analysis by a combination of CID, HCD, ETD, and EThcD on hybrid and tribrid Orbitrap instruments. Characteristic sulfated glyco-oxonium ions and direct loss of sulfite from precursors were detected as evidences of sulfate modification. It is anticipated that the technical advances demonstrated in this study would allow a feasible extension of our sulfoglycomic analysis to sulfoglycoproteomics.
Graphical Abstract ?
  相似文献   

15.
A comprehensive study using liquid chromatography electrospray ionization multistage mass spectrometry (LC-ESI MS n ) was performed to get detailed structural information on poly(butylene adipate-co-butylene terephthalate) co-polyester and its product of partial degradation. LC-MS and LC-MSn identified the existence of cyclic structures in the original samples that disappear completely during the degradation. The occurrence of methanol transesterification in the degradation process was confirmed. MS2 on the first 13C isotope peak helped to determine the elemental composition of the fragments and facilitated end group determination. The method can be used to provide an alternative for high mass accuracy MS2 experiments. Sequence information was also revealed for certain copolymeric structures.  相似文献   

16.
Ondansetron, a 5‐hydroxytryptamine type 3 (5‐HT3) receptor antagonist, is regarded as an excellent candidate to treat chemotherapy‐ and radiotherapy‐induced nausea and vomiting. To better understand the metabolic profiles of ondansetron in human urine, the metabolites were analyzed using liquid chromatography/mass spectrometry (LC/MSn). Urine samples were collected after oral administration of 8 mg ondansetron to healthy volunteers. Then samples were treated by solid‐phase extraction and detected with LC/MSn. Besides ondansetron, in human urine, a total of 19 metabolites including 13 new metabolites were detected and identified via comparing the retention time and product ion spectra with those of reference standards isolated and characterized. The results showed that ondansetron was metabolized via hydroxylation, glucuronidation, sulfation and minor N‐demethylation in human. LC/MSn was demonstrated to be useful and sensitive in the metabolic study of ondansetron.  相似文献   

17.
To gain perspective on building full transferable libraries of MSn spectra from their diverse/numerous collections, a new library was built from 1723 MS>1 spectra (mainly MS2 spectra) of 490 pesticides and related compounds. Spectra acquired on different types of tandem instruments in various experimental conditions were extracted from 168 literature articles and Internet sites. Testing of the library was based on searches where 'unknown' and reference spectra originated from different sources (mainly from different laboratories) were cross‐compared. The NIST 05 MS2 library was added to the reference spectra. The library searches were performed with all the test spectra or were divided into different subsamples containing (a) various numbers of replicate spectra of test compounds or (b) spectra acquired from different instrument types. Thus, the dependence of true/false search (identification) result rates on different factors was explored. The percentage of 1st rank correct identifications (true positives) for the only 'unknown' mass spectrum and two and more reference spectra and matching precursor ion m/z values was 89%. For qualified matches, above the cut‐off match factor, that rate decreased to 80%. The corresponding rates based on the best match for two and more 'unknown' and reference spectral replicates were 89–94%. For quadrupole instruments, the rates were even higher: 91–95% (one 'unknown' spectrum) and 90–100% (two and more such spectra). This study shows that MS2 spectral libraries generated from the numerous literature/Internet sources are not less efficient for the goal of identification of unknown compounds including pesticides than very common EI‐MS1 libraries and are almost as efficient as the most productive from current MS2 spectral databases. Such libraries may be used as individual reference databases or supplements to large experimental spectral collections covering many groups of abundant compounds and different types of tandem mass spectrometers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
Identification of drug metabolites can often yield important information regarding clearance mechanism, pharmacologic activity, or toxicity for drug candidate molecules. Additionally, the identification of metabolites can provide beneficial structure-activity insight to help guide lead optimization efforts towards molecules with optimal metabolic profiles. There are challenges associated with detecting and identifying metabolites in the presence of complex biological matrices, and new LC-MS technologies have been developed to meet these challenges. In this report, we describe the development of an experimental approach that applies unique features of the hybrid linear ion trap Orbitrap mass spectrometer to streamline in vitro and in vivo metabolite identification experiments. The approach, referred to as MSM, utilizes multiple collision cells, dissociation methods, mass analyzers, and detectors. With multiple scan types and different dissociation modes built into one experimental method, along with flexible post-acquisition analysis options, the MSM workflow offers an attractive option to fast and reliable identification of metabolites in different kinds of in vitro and in vivo samples. The MSM workflow was successfully applied to metabolite identification analysis of verapamil in both in vitro rat hepatocyte incubations and in vivo rat bile samples.  相似文献   

19.
In contrast to libraries with highly reproducible gas chromatography electron ionization mass spectra, current liquid chromatography (LC–MS) libraries are limited to specific instrument types. Therefore, the aim of the study was to prove whether a recently developed linear ion trap (LIT) LC–MSn screening approach and reference library can be transferred to an LC–MS/MS system with a quadrupole‐LIT hybrid mass analyzer using SmileMS, a sophisticated search algorithm. The LIT reference library was built with MS² and MS³ wideband spectra recorded on a ThermoFisher LXQ LIT with electrospray ionization in positive mode and full‐scan data‐dependent acquisition (DDA). Collision parameter optimizations, including different scan types and energies, were performed on an Applied Biosystems QTRAP 4000 system using electrospray ionization in positive mode and full‐scan DDA. Modified library sets were generated to improve the detection of a compound by the used search algorithm. Additionally, 100 authentic human urine samples were screened by both systems for proof of applicability. In the applicability study, 533 compounds were detected by the LXQ and 477 by the QTRAP system using enhanced product ion scan and a modified database. The presented data showed that the LIT screening approach and reference library could be used successfully on a QTRAP instrument with some limitations. These should be overcome by further optimizations regarding DDA settings for better sensitivity and further library modifications to reduce spectra mismatches. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
As recently reported, the synthetic cannabinoid JWH-018 is the subject of extensive phase I and II metabolic reactions in vivo. Since these studies were based on LC-MS/MS and/or GC-MS identification and characterisation of analytes, the explicit structural assignment of the metabolites was only of preliminary nature, if possible at all. Here, we report the chemical synthesis of five potential in vivo metabolites of JWH-018 derivatives featuring an alkylcarboxy (M1), a terminal alkylhydroxy (M2), a 5-indolehydroxy (M3), an N-dealkylated 5-indolehydroxy (M4) and a 2′-naphthylhydroxy (5) analogue, respectively, and their characterisation by nuclear magnetic resonance spectroscopy. The collision-induced dissociation (CID) patterns of the protonated compounds were studied by high-resolution/high-accuracy tandem mass spectrometry (MS n ) applying an LTQ Orbitrap with direct infusion and electrospray ionisation of target analytes. An unusual dissociation behaviour including a reversible ion–molecule reaction between a naphthalene cation (m/z 127) and water in the gas phase of the MS was shown to be responsible for nominal neutral losses of 10 u in the course of the CID pathway. LC-MS/MS-supported comparison of synthesised reference standards with an authentic urine sample using an API 4000 QTrap mass spectrometer identified the synthetic JWH-018 analogues M1–M4 as true in vivo metabolites, presuming a chromatographic separation of potentially present regioisomeric analogues. Existing doping control methods were expanded and validated according to international guidelines in order to allow for the detection of the carboxy and the alkylhydroxy metabolites, respectively, as urinary markers for the illegal intake of the synthetic cannabinoid JWH-018. Both metabolites were quantified in authentic doping control urine samples that had been suspicious of JWH-018 abuse after routine screening procedures, and a stable isotope-labelled 13C8-15N-carboxy metabolite was synthesised for future analytical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏