首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This report describes the use of PDMS ME coupled with amperometric detection for rapid separation of ascorbic, gallic , ferulic, p‐coumaric acids using reverse polarity. ME devices were fabricated in PDMS by soft lithography and detection was accomplished using an integrated carbon fiber working electrode aligned in the end‐channel configuration. Separation and detection parameters were investigated and the best conditions were obtained using a run buffer consisting of 5 mM phosphate buffer (pH 6.9) and a detection voltage of 1.0 V versus Ag/AgCl reference electrode. All compounds were separated within 70 s using gated injection mode with baseline resolution and separation efficiencies between 1200 and 9000 plates. Calibration curves exhibited good linearity and the LODs achieved ranged from 1.7 to 9.7 μM. The precision for migration time and peak height provided maximum values of 4% for the intrachip studies. Lastly, the analytical method was successfully applied for the analysis of ascorbic and gallic acids in commercial beverage samples. The results achieved using ME coupled with amperometric detection were in good agreement with the values provided by the supplier. Based on the data reported here, the proposed method shows suitability to be applied for the routine analysis of beverage samples.  相似文献   

2.
Wang AJ  Xu JJ  Zhang Q  Chen HY 《Talanta》2006,69(1):210-215
Poly(dimethylsiloxane) (PDMS) microfluidic channels modified by citrate-stabilized gold nanoparticles after coating a layer of linear polyethylenimine (LPEI) were successfully used to separate dopamine and epinephrine, which were difficult to be separated from baseline in native and hybrid PDMS microchannels. In-channel amperometric detection with a single carbon fibre cylindrical electrode was employed. Experimental parameters of separation and detection processes were optimized in detail. The analytes were well separated within 100 s in a 3.7 cm long separation channel at a separation voltage of +800 V using a 30 mM phosphate buffer solution (PBS, pH 7.0). Linear responses of them were obtained both from 25 to 600 μM with detection limits of 2 μM for dopamine and 5 μM for epinephrine, respectively. The modified PDMS channels have a long-term stability and an excellent reproducibility within 2 weeks.  相似文献   

3.
Li XA  Zhou DM  Xu JJ  Chen HY 《Talanta》2008,75(1):157-162
In this work, chloride, chlorate and perchlorate are fast separated on PDMS microchip and detected via in-channel indirect amperometric detection mode. With PDMS/PDMS microchip treated by oxygen plasma, anions chloride (Cl-), chlorate (ClO3-), and perchlorate (ClO4-) are separated within 35s. Some parameters including buffer salt concentration, buffer pH, separation voltage and detection potential are investigated in detail. The separation conditions using 15 mM (pH 6.12) of 2-(N-morpholino)ethanesulfonic acid (MES)+L-histidine (L-His) as running buffer, -2000 V as separation voltage and 0.7 V as detection potential are optimized. Under this condition, the detection limits of Cl-, ClO3-, and ClO4- are 1.9, 3.6, and 2.8 microM, respectively.  相似文献   

4.
8-Hydroxy-deoxyguanosine (8-OH-dG) DNA adduct is one of the most frequently used biomarkers reporting on the oxidative stress that leads to DNA damage. More sensitive and reliable microfluidic devices are needed for the detection of these biomarkers of interest. We have developed a capillary electrophoresis (CE)-based microfluidic device with an electroplated palladium decoupler that provides significantly improved detection limit, separation efficiency, and resolving power. The poly(dimethylsiloxane) (PDMS)/glass hybrid device has fully integrated gold microelectrodes covered in situ with palladium nanoparticles using an electroplating technique. The performance and coverage of the electrodes electroplated with palladium particles were evaluated electrochemically and via scanning electron microscope (SEM) imaging, respectively. The performance of the device was tested and evaluated with different buffer systems, pH values, and electric field strengths. The results showed that this device has significantly improved resolving power, even at separation electric field strengths as high as 600 V cm−1. The detection limit for the 8-OH-dG adduct is about 20 attomoles; the concentration limit is on the order of 100 nM (S/N = 3). A linear response is reported for both 8-OH-dG and dG in the range from 100 nM to 150 μM (≈100 pA μM−1) with separation efficiencies of approximately 120,000–170,000 plates m−1.  相似文献   

5.
Dou YH  Bao N  Xu JJ  Chen HY 《Electrophoresis》2002,23(20):3558-3566
Separation and direct detection of amino acids, glucose and peptide in a 3.1 cm separation channel made of poly(dimethylsiloxane) (PDMS) with end-column amperometric detection at a copper microdisk electrode was developed. This system is the integration of a normal sized working electrode with electrochemical detection on a PDMS microfabricated device. The PDMS channels dynamically modified by 2-morpholinoethanesulfonic acid (MES) show less adsorption and more enhanced efficiency than that of unmodified ones when applied to separations of these biological molecules. The migration time is less than 100 s and the reproducibility of migration time is satisfactory with relative standard deviation (RSD) of 2.8% in 19 successive injections. The limits of detection of arginine (Arg), glucose, and methionine-glycine (Met-Gly) are estimated to be 2.0, 8.5, and 64.0 microM at S/N = 3, approximately 0.5-16.0 fmol, respectively. Variances influencing the separation efficiency and amperometric response, including injection, separation voltage, detection potential, or concentration of buffer and additive, are assessed and optimized.  相似文献   

6.
This paper reports on the study of electroosmotic flow (EOF) in poly(dimethylsiloxane) (PDMS) microchannels on the basis of indirect amperometric detection method. Gradual increase of EOF rate in freshly prepared PDMS microchannels was observed with the running buffer of phosphate buffer solution (PBS). With the same concentration (10 mM) of PBS containing different cations and the same pH value (7.0) and, the time of the stable EOF in PDMS microchannels under the applied separation voltage of 1000 V was 49.8 s (Li+ -PBS), 57.1 s (Na+ -PBS), 91 s (K+ -PBS), respectively. Meanwhile, the different adsorption of cations (Li+, Na+ and K+) on hydrophobic PDMS wall was observed through their separation in PDMS microchannels. Such experimental results demonstrated that the EOF in PDMS microchannels came from the cations and anions adsorbed on PDMS wall. This study would not only help us understand the surface state of PDMS, but also provide a useful guidance for establishing the effective surface modification methods in PDMS microchip CE.  相似文献   

7.
Yan Xiao 《Talanta》2007,72(4):1316-1321
The separation of three kinds of aminophenol isomers were achieved within 1 min in polyelectrolytes multilayers modified PDMS microchips by layer-by-layer assembly with electrochemical detection (EC). Two polyelectrolytes, poly(dially dimethyl ammonium chloride) (PDDA) and poly(sodium-4-styrene-sulfonate) (PSS) were used to form polyelectrolyte multilayers (PEMs). The surface characteristic of the modified microchip was studied by XPS. The electroosmotic flow (EOF) on PEMs modified PDMS microchips was more stable than that of the native PDMS microchips and the adsorption of samples was greatly reduced on PEMs modified PDMS microchips during the electrophoretic process. The column efficiencies on PEMs modified microchip were increased by 100 times and the signals enhanced by 2 times compared with those of native microchips. The separation conditions such as running buffer pH, running buffer concentration and separation voltage were also optimized.  相似文献   

8.
A fully integrated polydimethylsiloxane (PDMS)/modified PDMS membrane/SU-8/quartz hybrid chip was developed for protein separation using isoelectric focusing (IEF) mechanism coupled with whole-channel imaging detection (WCID) method. This microfluidic chip integrates three components into one single chip: (i) modified PDMS membranes for separating electrolytes in the reservoirs from the sample in the microchannel and thus reducing pressure disturbance, (ii) SU-8 optical slit to block UV light (below 300?nm) outside the channel aiming to increase detection sensitivity, and (iii) injection and discharge capillaries for continuous operation. Integration of all these components on a single chip is challenging because it requires fabrication techniques for perfect bonding between different materials and is prone to leakage and blockage. This study has addressed all the challenges and presented a fully integrated chip, which is more robust with higher sensitivity than the previously developed IEF chips. This chip was tested by performing protein and pI marker separation. The separation results obtained in this chip were compared with that obtained in commercial cartridges. Side-by-side comparison validated the developed chip and fabrication techniques.  相似文献   

9.
This study explores the use of pH stacking in conjunction with 5-aminofluorescein as a derivatization agent for the sensitive analysis of simple sugars such as glucose, lactose and maltotriose by capillary electrophoresis (CE). The derivatization agent was selected on the basis of its extremely high molar absorptivity, its compatibility with a 488nm light-emitting diode (LED) and the fact that it has two ionizable groups making it compatible with on-line stacking using a dynamic pH junction. The influence of both acetic and formic acids at concentrations of 0.19, 0.019 and 0.0019molL(-1) were investigated with regard to both derivatization efficiency and the ability to stack using a dynamic pH junction. Superior sensitivity and resolution was obtained in formic acid over acetic acid. Substantially lower peaks were obtained with 0.19molL(-1) formic acid when compared to 0.019 and 0.0019molL(-1) concentrations, which was confirmed by computer simulation studies to be due to the inadequate movement of the pH boundary for stacking. Further simulation studies combined with experimental data showed the separation with the best resolution and greatest sensitivity when the carbohydrates were derivatized with the 0.095molL(-1) formic acid. Utilisation of stacking via dynamic pH junction mode in conjunction with LED detection enabled efficiencies of 150,000 plates and detection limits in the order of 8.5x10(-8)molL(-1) for simple sugars such as glucose, lactose and maltotriose hydrate. The current system also demonstrates a 515 times improvement in sensitivity when compared to using a normal deuterium lamp, and 16 times improvement over other systems using LEDs.  相似文献   

10.
Isoelectric focusing (IEF), traditionally accomplished in slab or tube gels, has also been performed extensively in capillary and, more recently, in microchip formats. IEF separations performed in microchips typically use electroosmotic flow (EOF) or chemical treatment to mobilize the focused zones past the detection point. This report describes the development and optimization of a microchip IEF method in a hybrid PDMS-glass device capable of controlling the mobilization of the focused zones past the detector using on-chip diaphragm pumping. The microchip design consisted of a glass fluid layer (separation channels), a PDMS layer and a glass valve layer (pressure connections and valve seats). Pressure mobilization was achieved on-chip using a diaphragm pump consisting of a series of reversible elastomeric valves, where a central diaphragm valve determined the volume of solution displaced while the gate valves on either side imparted directionality. The pumping rate could be adjusted to control the mobilization flow rate by varying the actuation times and pressure applied to the PDMS to actuate the valves. In order to compare the separation obtained using the chip with that obtained in a capillary, a serpentine channel design was used to match the separation length of the capillary, thereby evaluating the effect of diaphragm pumping itself on the overall separation quality. The optimized mIEF method was applied to the separation of labeled amino acids.  相似文献   

11.
A new glass/PDMS hybrid chip for contactless conductivity detection is reported. This chip consists of a glass substrate with microchannels and a PDMS cover sheet embedded with a small integrated electrode plate. In the region of detection, electrodes are insulated from the microchannel by a formed PDMS membrane about 100 μm in thickness. Without any modification, this glass/PDMS chip is suitable for contactless conductivity detection with good properties, such as excellent heat-dissipation, stable electroosmotic flow, high separation efficiency, satisfactory sensitivity, simple construction and high degree of integration. Its feasibility and performance had been demonstrated by analyzing inorganic ions and amino acids in mixtures, and alkaloids in traditional Chinese medicine. The limits of detection reached micromole per liter (μmol L?1) levels. This microchip could be promising for mass production due to its stability, reproducibility, ease of fabrication and low cost.  相似文献   

12.
This paper characterizes the basic electrokinetic phenomena occurring within native poly(dimethylsiloxane) (PDMS) microchannels. Using simple buffers and current measurements, current density and electroosmosis data were determined in trapezoidal, reversibly sealed PDMS/PDMS and hybrid PDMS/glass channels with a cross-sectional area of 1035.5 microm(2) and about 6 cm length. This data was then compared to that obtained in an air-thermostated 50 microm inner diameter (1963.5 microm(2) cross-sectional area) fused-silica (FS) capillary of 70 cm length. Having a pH 7.8 buffer with an ionic strength (I) of 90 mM, Ohms's law was observed in the microchannels with electric field strengths of up to about 420 V/cm, which is about twice as high as for the FS capillary. The electroosmotic mobility (micro(EO)) in PDMS and FS is shown to exhibit the same general dependences on I and pH. For all configurations tested, the experimentally determined micro(EO) values were found to correlate well with the relationship micro(EO) = a + b log(I), where a and b are coefficients that are determined via nonlinear regression analysis. Electroosmotic fluid pumping in native PDMS also follows a pH dependence that can be estimated with a model based upon the ionization of silanol. Compared to FS, however, the magnitude of the electroosmotic flow in native PDMS is 50-70% smaller over the entire pH range and is difficult to maintain at acidic pH values. Thus, the origin of the negative charge at the inner wall of PDMS, glass, and FS appears to be similar but the density is lower for PDMS than for glass and FS.  相似文献   

13.
J S Kim  D R Knapp 《Electrophoresis》2001,22(18):3993-3999
A multichannel electrospray ionization (ESI) emitter was fabricated as part of a poly(dimethylsiloxane) (PDMS) microfluidic device using a three-layer photoresist process which also produces a self-alignment system to make a bonding between the top and bottom PDMS parts. The prototype device (2 cm high x 5 cm wide x 5 cm long) had 16-channels (30 microm wide x 50 microm deep) with emitters of 1 mm length and 60 degrees point angle. The PDMS emitter tips enabled interfacing the device to ESI-mass spectrometry; a stable electrospray from the tips was performed with limits of detection under 1 microM for reference peptides (adrenocorticotropic hormone fragment 1-17, angiotensin I and III).  相似文献   

14.
In the proposed simple, disposable forced flow paper chromatographic device the main features of the separation like the analysis of time, separation power were improved. The chromatographic paper strips embedded into a polydimethylsiloxane (PDMS) block can be considered as an adsorption column, on which the liquid can be pumped. In a single device numerous separations can be performed in multiplex mode. On-capillary spectrophotometric detection is capable to detect the separated zones with good sensitivity.  相似文献   

15.
Dou YH  Bao N  Xu JJ  Meng F  Chen HY 《Electrophoresis》2004,25(17):3024-3031
Separation and detection of proteins have been realized on nonionic surfactant-modified poly(dimethylsiloxane) (PDMS) microfabricated devices with end-column amperometric detection. The hydrophobic PDMS channels are turned into hydrophilic ones after being modified with Brij35 and facilitate the separation of proteins. The coating can remarkably reduce the adsorption of large protein molecules and is stable in the range of pH 6-12. The detection of proteins in such channels needs less rinsing time and thus efficiency is raised. Even large molecules of proteins can also be detected with better reproducibility and enhanced plate numbers. The relative standard deviation (RSD) of the migration time for glucose oxidase (GOD) is 2.2% (n = 19). Separation of GOD and myoglobin has been developed in modified channels. Predominant operational variables, such as the coating conditions, the concentration of surfactant and buffer, are studied in detail.  相似文献   

16.
Microchip CE coupled with electrochemical detection (MCE-EC) is a good method for the direct detection of many small molecule analytes because the technique is sensitive and readily miniaturized. Polymer materials are being increasingly used with MCE due to their affordability and ease of fabrication. While PDMS has become arguably the most widely used material in MCE-EC due to the simplicity of microelectrode incorporation, it suffers from a lack of separation efficiency, lower surface stability, and a tendency for analyte sorption. Other polymers, such as poly(methylmethacrylate) (PMMA) and poly(carbonate) (PC), have higher separation efficiencies but require more difficult fabrication techniques for electrode incorporation. In this report, thermoset polyester (TPE) was characterized as an alternative material for MCE-EC. TPE microchips were characterized in their native and plasma oxidized forms and after coating with polyelectrolyte multilayers (PEMs). TPE provides higher separation efficiencies when compared to PDMS microchips, while still using simple fabrication protocols. In this work, separation efficiencies as high as 295,000 N/m were seen when using TPE MCE-EC devices. Furthermore, the EOF was higher and more consistent as a function of pH for both native and plasma-treated TPE than PDMS. Finally, TPE is amenable to modification using simple PEM coatings as another way to control surface chemistry and surface charge.  相似文献   

17.
Zeng HL  Li HF  Wang X  Lin JM 《Talanta》2006,69(1):226-231
A β-cyclodextrin (β-CD)-bonded gel monolithic column polydimethylsiloxane (PDMS) microfluidic device was developed in a simple and feasible way. Before preparation of gel monolithic column in PDMS microchannel, PDMS surface was activated by UV light to create silanol groups, which is an active molecule to covalently bond 3-(trimethoxysilyl)-propyl methacrylate (Bind-Silane) and seal microfluidic device. By the way, Bind-Silane is a bifunctional molecule to link polyacrylamide (PAA) gel and inner wall of PDMS microchannel covalently. Allyl-β-CD was used not only as a multifunctional crosslinker in PAA gel to control the size of the pores, but also as a chiral selector for the enantioseparation. The stability, transferring heat and optical characteristic of the microfluidic device were examined. The separation capability of the gel monolithic column was confirmed by the successful separation of fluorescein isothiocyanate (FITC)-labeled arginine (Arg), glutamine acid (Glu), tryptophan (Try), cysteine (Cysteine) and phenylalanine (Phe) in the PDMS microfluidic device less than 100 s at 36 mm effective separation length. A maximum of 2.06 × 105 theoretical plates was obtained by the potential strength of 490 V/cm. A pair of FITC-labeled dansyl-d,l-threonine (Dns-Thr) was separated absolutely.  相似文献   

18.
The separation and detection of common mono- and disaccharides by capillary electrophoresis (CE) with contactless conductivity detection (CCD) is presented. At high values of pH, the sugars are converted to anionic species that can be separated by CE and indirectly detected by CCD. The main anionic species present in the running electrolytes are hydroxide and phosphate, which have greater mobility than the ionized sugars, and, thus, the indirect detection is possible. The method was applied to analysis of glucose, fructose, and sucrose in soft drinks, isotonic beverages, fruit juice, and sugarcane spirits. Galactose was used as internal standard in all cases. Plate numbers range from ca. 70,700 to 168,200 and the limits of detection from 13 to 31 microM.  相似文献   

19.
We report amperometric determination of sugars by using a disposable barrel plating nickel electrode (Ni‐BPE) in this study. The activated Ni‐BPE possesses good reproducibility in flow injection analysis of sugars with a relative standard deviation of 3.16% for 10 consecutive injections of glucose. The electrocatalytic mechanism for the detection of sugars as well as the use as a detector in high‐performance liquid chromatography (HPLC) is investigated. We achieve a good separation of four sugars (glucose, fructose, sucrose, and maltose) in HPLC with favorable sensitivity at a detection potential of +0.55 V vs. Ag/AgCl. The results of wide linear calibration ranges and detection limits in the μM range meet the need of real sample analysis. This detection method is successfully used for quantitative determination of sugars in honey to identify its authentication.  相似文献   

20.
Processes such as chromatographic separation and nanofiltration can remove low molecular weight sugars from liquid mixtures of oligosaccharides. As an alternative for the separation of such liquid mixtures, we studied mass diffusion separation of such sugars in a microfluidic device with incorporated nanofiltration membranes. This separation method is based on differences between diffusivities of components and does not require high transmembrane pressures. The effects of channel depth and flow rate were studied in experiments. The key parameters selectivity and rejection increased with increasing channel depth due to increased external mass transfer limitations. Among the studied membranes, the obtained selectivities and rejections correlated to the specified retention values by the manufacturers. Compared to more conventional nanofiltration where high pressure forces solutes through membranes, we obtained corresponding selectivities and fluxes of only an order of magnitude smaller. Simulated results indicated that with optimized microchannel and membrane dimensions, the presented separation process can compete with currently available separation technologies.  相似文献   