首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
建立了淋洗液自动发生梯度淋洗的离子交换色谱法同时测定果汁中乳酸、乙酸、苹果酸、丙二酸、马来酸、草酸、柠檬酸、异柠檬酸8种有机酸的分析方法.样品经处理后用lonPac AS11-HC分离柱和lonPac AG11-HC型保护柱分离,以EG40自动淋洗液发生器生成的0.8~30 mmol/L KOH为淋洗液梯度洗脱,抑制型...  相似文献   

2.
Summary The optimization of chromatographic methods for the determination of metal species require an understanding of the mechanisms involved. In this work, the separation of Cd, Co, Cu, Fe(II/III), Mn, Pb and Zn using a mixed bed column (IonPac CS5A) and a cation-exchange column (IonPac CS2) is studied as a function of mobile phase composition. The type and concentration of complexing agent and of ionic strength modificators were evaluated. The charge of analytes were calculated using the classical ion exchange approach to highlight the effect of eluent composition on retention. The comparative study enabled us to identify an optimal eluent composition for the separation of the nine metal species.  相似文献   

3.
Summary An ion chromatographic method has been developed for the separation of Te (IV) and Se(IV) in hydrochloric acid mobile phases; the method has been used to determine tellurium in a high-purity non-stoichiometric semiconducting ZnCdTe-based material. Different cation-exchange columns (IonPac CS2, CS3, CS10), a mixed bed ion-exchange column (IonPac CS5), a multi-mode cation-exchange column (OmniPac PCX-500), anion-exchange columns (IonPac AS4, AS4A, AS5, AS5A, AS10, AS11) and a multi-mode anion-exchange column (OmniPac PAX-500) were evaluated for ion chromatographic separation of Se and Te and to study the chemical forms in which the analytes were eluted. The chromatographic data obtained enabled the calculation of both the sign and the chaarge of the eluting species.  相似文献   

4.
建立了一种梯度洗脱-电导抑制-离子色谱同时测定4种强极性农药的方法.通过对淋洗液及浓度、色谱柱、柱温、进样量等条件的优化,得到最佳检测条件:色谱柱为IonPac AS11-HC分析柱及IonPac AG11-HC保护柱,柱温33℃,进样量50μL,RFIC系统的淋洗液自动发生器在线产生的KOH作为淋洗液,梯度洗脱,淋洗...  相似文献   

5.
烟草中9种有机酸的梯度离子色谱法测定研究   总被引:2,自引:0,他引:2  
采用淋洗液自动发生一梯度离子色谱分离,电导检测法分离测定了烟草中的甲酸、乙酸、乳酸、丙酸、丁酸、苹果酸、丙二酸、草酸和柠檬酸,并研究了9种有机酸在阴离子交换色谱中的保留行为.以淋洗液自动发生器生成的KOH为淋洗液,样品经提取、过滤稀释后,在IonPac AS1l-HC阴离子交换色谱柱上分离,抑制电导检测器进行检测,一次...  相似文献   

6.
US Environmental Protection Agency Method 300.0 specifies the use of an IonPac AS4A anion-exchange column with a carbonate-hydrogencarbonate eluent and suppressed conductivity detection for the determination of inorganic anions in environmental waters by ion chromatography. Hydroxide eluents have not typically been used for the routine analysis of common inorganic anions due to the lack of an appropriate hydroxide selective column and the difficulty in preparing contaminant free hydroxide eluents. The use of ion chromatography with a hydroxide-selective IonPac AS17 column, automated eluent generation and potassium hydroxide gradient represents a new approach to the routine determination of inorganic anions in environmental waters. This new approach, which is a modification of Method 300.0, allows equivalent method performance with improved linearity, precision, and method detection limits. The AS17 column provides superior retention of fluoride from the column void volume and improved resolution from small organic acids, such as formate and acetate, compared to the AS4A column. Quantitative recoveries were obtained for all the common inorganic anions spiked into typical environmental waters using this new approach, and the Performance Based Measurement System Tier 1 method validation quality control acceptance criteria are well within the acceptable ranges defined by Method 300.0. In addition, the EG40 eluent generator eliminates the need to manually prepare eluents, increasing the level of automation and ease-of-use of the ion chromatography system.  相似文献   

7.
建立了高氯、高钠油田回注水中痕量无机阴、阳离子和有机酸的离子色谱分析方法。对高钠基质中痕量阳离子的测定,选用IonPac CS12A分析柱、H2SO4溶液梯度淋洗、电导检测器检测;对高氯基质中阴离子及有机酸的测定,选用对OH-具有高选择性的高容量的IonPac AS11-HC柱、KOH梯度淋洗、电导检测器检测。在优化的梯度淋洗条件下,高氯或高钠的存在不影响痕量阴离子或阳离子的测定。该方法具有良好的线性(r=0.9926~0.9990)和精密度(测定组分峰面积的相对标准偏差(n=7)在8.0%以下),回收率  相似文献   

8.
The chromatographic performance of the Dionex IonPac ICE-AS6 ion exclusion column is investigated. Therefore, capacity factors, efficiency, peak symmetry, resolution, and selectivity are determined for various mono- and polyfunctional aliphatic carboxylic acids under selected chromatographic conditions. Except for the stronger acids (pKa1 < 3.75), the highest chromatographic efficiency is achieved at a column temperature of 40 or 50 degrees C, and peak shape is found to be optimal at approximately 60 degrees C. The separation of the stronger acids is favored by an eluent pH below 3.0 and column temperatures below 40 degrees C. The maximal effective plate numbers range between 126 (tartronic acid) and 6380 (4-oxovaleric acid). Hydroxy-substituted acids are less retained and less influenced by temperature changes than the unsubstituted compounds. It is estimated that size exclusion effects take part in the separation of aldonic acids. The addition of 1% isopropanol to the acidic eluent increases the chromatographic efficiency generally, whereas higher concentrations reduce the retention of several acids drastically.  相似文献   

9.
A method for the separation of acetate and formate anions by ion chromatography has been optimized under various measurement conditions (e.g. the composition of the mobile phase, and the flow rate of the eluent). For this purpose, two different analytical columns were examined: the IonPac AS14 (250 mm x 4 mm i.d.; designed mostly for the separation of inorganic anions) and the Allsep A-2 (150 mm x 4.6 mm i.d.; designed for the separation of low-molecular mass organic acids). However, nearly baseline separation of acetate and formate has been found on each column using the following conditions: (i) IonPac AS14 column and 2.0 mM Na2B4O7 solution as an eluent with a flow rate of 1.0 ml/min, or (ii) Allsep A-2 column and an eluent containing a mixture of 1.2 mM Na2CO3 plus 1.5 mM NaHCO3 with a flow rate of 1.3 ml/min. Additionally, the separation of fluoride from acetate and formate on both columns was studied. On the IonPac AS14 column it was possible to separate all three investigated anions. However, on the Allsep A-2 column, when the concentration of fluoride was comparable to, or higher than acetate, it was impossible to achieve good separation of these two anions, even using the optimized elution procedure. Therefore, the measurements of real samples were carried out with the use of IonPac AS14 column. The concentrations of acetate and formate have been determined in the air samples of the Cathedral of Cologne (Germany), after sampling the corresponding acids by passive diffusion tubes. Average concentrations of 122 and 9 microg/m(3) for acetic and formic acids were found, respectively, inside the Cathedral and in a depot with medieval stained glass panels.  相似文献   

10.
Preconcentration and separation of haloacetic acids by ion chromatography   总被引:7,自引:0,他引:7  
A comparative study was made of the chromatographic behaviour of five haloacetic acids (mono-, dibromoacetic and mono-, di-, trichloroacetic acids). The techniques investigated included reversed-phase ion interaction chromatography with UV detection, suppressed and non-suppressed anion-exchange chromatography. The systems are discussed studying the retention as a function of the mobile phase parameters and the stationary phases used (LiChrospher 100 RP-18, IonPac AS9, AS10 and AS11). A preconcentration step, performed on different substrates, namely LiChrolut-EN and activated vegetal carbon, has been optimized in order to reduce the method detection limits. Results obtained for drinking water samples are shown.  相似文献   

11.
为实现简单基质样品中常规阴离子的快速分析,选用Dionex IonPac AS22-fast(4mm×150mm)离子交换色谱柱,通过优化流速、淋洗液浓度等色谱条件,使F-、Cl-、NO3-、NO2-、Br-、PO43-、SO42-7种常规阴离子在3.5min内分离完全,实现简单基质样品中常规阴离子的快速测定。  相似文献   

12.
Ammonium perchlorate, a key ingredient in solid rocket propellants, has recently been found in ground and surface waters in the USA in a number of states, including California, Nevada, Utah, and West Virginia. Perchlorate poses a health risk and preliminary data from the US Environmental Protection Agency reports that exposure to less than 4–18 μg/l provides adequate human health protection. An ion chromatographic method was developed for the determination of low μg/l levels of perchlorate in drinking and ground waters based on a Dionex IonPac AS11 column, a 100 mM hydroxide eluent, large loop (1000 μl) injection, and suppressed conductivity detection. The method is free of interferences from common anions, linear in the range of 2.5–100 μg/l, and quantitative recoveries were obtained for low μg/l levels of perchlorate in spiked drinking and ground water samples. The method detection limit of 0.3 μg/l permits quantification of perchlorate below the levels which ensure adequate health protection. A new polarizable anion analysis column, the IonPac AS16, and its potential applicability for this analysis is also discussed.  相似文献   

13.
离子法测定高氯气田水中的氯离子及其他痕量无机阴离子   总被引:18,自引:0,他引:18  
丁永胜  牟世芬 《色谱》2002,20(3):262-264
 研究了高氯气田水样中的Cl-及痕量F-,Br-,I-和SO42 -的离子分析方法。选择的条件为 :亲水性较强的IonPacAS11阴离子交换分离柱分离 ,氢氧化钠梯度淋洗 ,自动再生抑制型电导检测。样品通过 0 4 5 μm微孔滤膜过滤和DionexOnGuardRPC18反相小柱处理。方法具有良好的线性 (相关系数在 0 9994~ 0 9999)和重复性 (相对标准偏差小于 3 3% ) ,加标平均回收率在 98 4 %~ 10 2 1%。方法简便实用 ,用于实际样品分析 ,所得结果令人满意。  相似文献   

14.
建立了同时检测化妆品中溴酸盐和碘酸盐的离子色谱-柱后衍生紫外检测器定量分析方法。样品用水提取,经RP柱净化,采用IonPac AS11-HC色谱柱分离,以EG40自动淋洗液发生器生成的KOH为淋洗液梯度洗脱,溴化钾、亚硝酸钠为衍生试剂,二极管阵列检测器检测,外标法定量。结果表明:该方法在2.0~1 000 mg/kg范围内线性关系良好(r≥0.999 8);加标回收率为84%~99%;相对标准偏差小于2%。方法简单、快速、选择性强,可用于化妆品中碘酸盐和溴酸盐的测定。  相似文献   

15.
A method has been developed for separation of 20 kinds of aromatic carboxylic acid using anion-exchange chromatography. A Dionex IonPac AS9-HC guard column (250mm×2mm) was used with a 9mmol/L sodium carbonate solution containing 50% (v/v) acetonitrile as eluent. A set of retention time data has been obtained using a conductivity detector DS6. Furthermore, geometrical optimization and electrostatic potential calculation of 20 kinds of aromatic carboxylic acid have been performed at the HF/6-31G* level of theory. A number of statistically-based parameters derived from molecular surface electrostatic potential have been obtained. Linear relationship between retention time and structural parameters has been established by multiple regression method. The result shows that parameters derived from electrostatic potential Vs +, Vs -, П together with the dipole moment μ can be well used to express the quantitative structure-retention time of this kind of aromatic carboxylic acid. Good predictive capability has also been demonstrated. The result has provided a framework which further proves the general applicability of this electrostatic potential parameter set to a great extent,and with which the ion chromatographic adsorption mechanism can be investigated.  相似文献   

16.
Ion chromatography (IC) has gradually developed into a preferred method for the determination of inorganic anions. And in recent years some low molecular aliphatic acid can be also separated in the ion exchange column with the development of stationary phase. But for the determination of aromatic ionic compounds there are some problems. The aromatic anions show enhanced retention due to interaction with the π electrons of the aromatic backbone. Although the addition of an organic modifier can alleviate the difficulty, it is not the ultimate solution. IonPac AS20 column was developed using a unique polymer bonding technology and its substrate coating is aliphatic backbone. The polymer is completely free of any π electron‐containing substituents in the AS20 column. In this paper, the retention behavior of aromatic carboxylic and sulfonic acid on two hydroxide‐selective columns, IonPac AS11‐HC, AS16, and the new column AS20 was also studied. The result showed that the retentions of ten compounds on three columns were different with each other because of their different column characteristics. Among them 4‐chlorobenzene sulfonic acid, 3,5‐dihydric benzoic acid and salicylic acid obviously exhibited the weakest retention on the IonPac AS20. It was showed that π‐π bond function between anion and stationary phases was weakened in AS20 column because its polymer was completely free of any π electron‐containing substituents. So in this paper the AS20 was selected as an analytical column to separate ten aromatic ionic compounds, fumaric acid with conjugate bond included. The retention behavior, separation of the ten compounds and effect of temperature on their retention in the anion‐exchange column AS20 (2 mm) were studied. The result showed that those compounds could be separated with each other when running in gradient program and the organic modifier was unnecessary during the separation. So it is showed that AS20 column can be used as a separating column because its polymer is completely free of any π electron‐containing substituents. Finally, the effect of temperature on the retention behavior in AS20 column was studied and it was showed that the retention of nine compounds exhibited endothermic behavior.  相似文献   

17.
The IonPac AS14A is a recently developed stationary phase that was produced using a new block-grafting technique, which enables the preparation of high-water-content anion exchangers with excellent peak shape and good chromatographic efficiency. The performance of this column for the analysis of inorganic anions was compared to that obtained using an IonPac AS4A column, which is specified in US Environmental Protection Agency Method 300.0, in addition to another commonly used alternative; the AS14 column. The AS14A column is available in two different formats; 250×4 mm I.D. (7.0 μm diameter particle) and 150×3 mm I.D. (5.5 μm diameter particle). The IonPac AS14A (in 4 mm I.D. format) was found to provide similar performance to the AS14 column with increased peak efficiency and better pH stability and is a suitable alternative for the analysis of anions in moderate- to high-ionic-strength samples. The IonPac AS14A (in 3 mm I.D. format) provides comparable run times to the AS4A column with better overall peak selectivity and improved fluoride resolution, hence this column would be a suitable column to substitute in place of either the AS4A or AS14 columns for the analysis of inorganic anions in low- to moderate-ionic-strength environmental waters. The AS14A column used with an Atlas electrolytic suppressor provides equivalent method detection limits to those obtained when using a micromembrane suppressor but with the operational convenience of a self-regenerating suppressor.  相似文献   

18.
离子交换色谱中混合保留机理的研究   总被引:1,自引:0,他引:1  
张嘉捷  王雪  陈梅兰  朱岩 《化学学报》2008,66(8):964-968
鉴于离子交换色谱中被测离子和有机聚合物树脂之间存在的吸附作用, 选择阴离子交换色谱柱IonPacAS9-HC为研究对象, 针对离子交换色谱中的吸附保留行为, 从色谱混合保留机理的角度出发, 考虑各色谱柱固定相含量和界面吸附面积的不同, 建立柱间保留的相互关系方程. 在五根不同批号IonPacAS9-HC (250 mm×2 mm I.D.)柱上, 以含50%乙腈(V/V)的9 mmol/L Na2CO3为流动相, 0.25 mL/min流速, 对12个不同结构类型的无机和有机阴离子(氟离子、氯离子、硫酸根、磷酸根、二羟基丁酸、丙酮酸、乙酸、丙烯酸、苯甲酸、丙二酸、酒石酸和邻苯二甲酸)的保留行为进行研究, 并采用推导所得的混合保留机理模型对溶质这一保留特征进行表征, 结果较为理想, 其中一价离子的相关系数为0.9~0.999, 二价离子的相关系数为0.999~1, 为离子交换色谱中吸附保留行为的研究提供了新方法.  相似文献   

19.
Ammonium perchlorate, a key ingredient in solid rocket propellants, has been found in ground and surface waters in a number of U.S. states, and perchlorate contamination of public drinking water wells is now a serious problem in California. Perchlorate poses a health risk and preliminary data from the U.S. EPA reports that exposure to less than 4-18 microg/l provides adequate human health protection. An improved ion chromatographic method was developed for the determination of low microg/l levels of perchlorate in ground and drinking waters based on a Dionex IonPac AS16 column, an hydroxide eluent generated using an EG40 automated eluent generator, large loop (1000 microl) injection, and suppressed conductivity detection. The method is free of interferences from common inorganic anions, linear over the range of 2-100 microg/l perchlorate, and quantitative recoveries are obtained for low microg/l levels of perchlorate in spiked ground and drinking water samples. The MDL of 150 ng/l permits quantification of perchlorate below the levels that ensure adequate health protection.  相似文献   

20.
离子色谱法及聚类分析研究主流烟气中的有机酸   总被引:1,自引:0,他引:1  
建立了超声辅助萃取-离子色谱法同时测定卷烟主流烟气中主要有机酸的方法.采用20 mL 30 mmol/L J NaOH溶液在50℃下对捕集了卷烟主流烟气的剑桥滤片超声萃取50 min,AS11-HC分离柱、Ion AG11-HC保护柱、ASRS-ULTRAⅡ抑制器,KOH溶液为淋洗液,用电导检测器同时测定了卷烟主流烟气中的乳酸、甲酸、乙酸、丙酸、苹果酸和草酸的含量.方法的线性范围1.0~400 mg/L,相关系数为0.9990~0.9995,相对标准偏差1.4%~4.8%,检出限0.03~0.09 mg/L,回收率为92%~104%.采用此方法测定了19种不同规格卷烟样品主流烟气中6种有机酸的含量,并且以6种有机酸为指标对样品进行了聚类分析.结果表明,6种有机酸的含量分布特征可反映不同等级卷烟产品的特性,可用于不用等级卷烟产品的比较和分类.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号