首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Biophenolic compounds constitute a complex mixture in olives and derived products. In this work, ion‐spray tandem mass spectrometry coupled with liquid chromatography is applied to the identification and quantification of biophenols present in complex matrices such as olives and vegetation waters. The extraction and purification method for the biophenol present in both the matrices is reported. Using this approach the main biophenols found, in three different variety of olives, were: tyrosol, hydroxytyrosol, oleoside methyl ester, oleoside dimethyl ester, and oleuropein. In vegetation water the biophenols are present in lower amounts than in olives.  相似文献   

2.
Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK‐positive nonsmall‐cell lung cancer. A rapid and simple high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC‐MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
The analysis of synthetic cannabinoids in human matrices is of particular importance in the fields of forensic and clinical toxicology since cannabis users partly shift to the consumption of ‘herbal mixtures’ as a legal alternative to cannabis products in order to circumvent drug testing. However, comprehensive methods covering the majority of synthetic cannabinoids already identified on the drug market are still lacking. In this article, we present a fully validated method for the analysis of 30 synthetic cannabinoids in human serum utilizing liquid‐liquid extraction and liquid chromatography‐electrospray ionization tandem mass spectrometry. The method proved to be suitable for the quantification of 27 substances. The limits of detection ranged from 0.01 to 2.0 ng/mL, whereas the lower limits of quantification were in the range from 0.1 to 2.0 ng/mL. The presented method was successfully applied to 833 authentic serum samples during routine analysis between August 2011 and January 2012. A total of 227 (27%) samples was tested positive for at least one of the following synthetic cannabinoids: JWH‐018, JWH‐019, JWH‐073, JWH‐081, JWH‐122, JWH‐200, JWH‐203, JWH‐210, JWH‐307, AM‐2201 and RCS‐4. The most prevalent compounds in positive samples were JWH‐210 (80%), JWH‐122 (63%) as well as AM‐2201 (29%). Median serum concentrations were all below 1.0 ng/mL. These findings demonstrate a significant shift of the market of synthetic cannabinoids towards substances featuring a higher CB1 binding affinity and clearly emphasize that the analysis of synthetic cannabinoids in serum or blood samples requires highly sensitive analytical methods covering a wide spectrum of substances. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

5.
A sensitive and rapid high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method has been developed and validated for the determination of gymnemagenin (GMG), a triterpene sapogenin from Gymnema sylvestre, in rat plasma using withaferin A as the internal standard (IS). Plasma samples were simply extracted using liquid–liquid extraction with tetra‐butyl methyl ether. Chromatographic separation was performed on Luna C18 column using gradient elution of water and methanol (with 0.1% formic acid and 0.3% ammonia) at a flow rate of 0.8 mL/min. GMG and IS were eluted at 4.64 and 4.36 min, ionized in negative and positive mode, respectively, and quantitatively estimated using multiple reaction monitoring (MRM) mode. Two MRM transitions were selected at m/z 505.70 → 455.5 and m/z 471.50 → 281.3 for GMG and IS, respectively. The assay was linear over the concentration range of 5.280–300.920 ng/mL. The mean plasma extraction recoveries for GMG and IS were found to be 80.92 ± 8.70 and 55.63 ± 0.76%, respectively. The method was successfully applied for the determination of pharmacokinetic parameters of GMG after oral administration of G. sylvestre extract. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A simple and sensitive method was developed for determination of illegal adulterants (yohimbine, sildenafil, vardenafil and tadalafil) in dietary supplements by HPLC‐MS/MS. The separation was achieved on a C18 column with the mobile phase consisting of acetonitrile and 0.1% acetic acid aqueous solution with a gradient elution at a flow rate of 0.5 mL/min. The analytes were quantified and identified by two characteristic transitions using the multiple‐reaction monitoring mode. The recoveries of the analytes ranged from 77.5 to 109.3% with the RSD less than 8.1% (n=6). The method has been successfully applied to screen illegal adulterations of natural dietary supplements.  相似文献   

7.
To investigate the consistency and bioequivalence of tacrolimus ointment reference and trial formulation, the tacrolimus concentrations in blood and skin were determined by HPLC‐ESI‐MS/MS following topical application of two kinds of ointment in porcine skin in a parallel, cross‐over trial. The plasma protein of blood was precipitated by acetonitrile and the tacrolimus in skin was extracted by acetonitrile before HPLC‐ESI‐MS/MS analysis. The internal calibration method (diazepam was the internal standard) was used for quantification analysis (R2 > 0.9999), with linear range from 0.05 to 5 ng/mL for blood samples and from 1 to 200 ng/mL for skin samples. The limits of detection for the porcine blood and skin were 0.005 and 0.5 ng/mL, respectively. The average recoveries for the porcine blood and skin spiked at three levels were 97.56–109.53 and 96.48–103.57%, respectively. The precision expressed in RSDs was from 3.43 to 10.83% for porcine blood and from 3.10 to 8.69% for porcine skin. For the same pig, the tacrolimus concentrations and variation with time of the two kinds of ointment in porcine skin were similar, although variation occurred with different individuals. These results showed that the release and penetration of tacrolimus from the reference and trial formulation are similar. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive analytical method has been developed and validated for the quantification of L‐ergothioneine in human plasma and erythrocytes by liquid chromatography‐tandem mass spectrometry. A commercially available isotope‐labeled L‐ergothioneine‐d9 is used as the internal standard. A simple protein precipitation with acetonitrile is utilized for bio‐sample preparation prior to analysis. Chromatographic separation of L‐ergothioneine is conducted using gradient elution on Alltime C18 (150 mm × 2.1 mm, 5 µ). The run time is 6 min at a constant flow rate of 0.45 ml/min. The mass spectrometer is operated under a positive electrospray ionization condition with multiple reaction monitoring mode. The mass transitions of L‐ergothioneine and L‐ergothioneine‐d9 are m/z 230 > 127 and m/z 239 > 127, respectively. Excellent linearity [coefficient of determination (r2) ≥ 0.9998] can be achieved for L‐ergothioneine quantification at the ranges of 10 to 10 000 ng/ml, with the intra‐day and inter‐day precisions at 0.9–3.9% and 1.3–5.7%, respectively, and the accuracies for all quality control samples between 94.5 and 101.0%. This validated analytical method is suitable for pharmacokinetic monitoring of L‐ergothioneine in human and erythrocytes. Based on the determination of bio‐samples from five healthy subjects, the mean concentrations of L‐ergothioneine in plasma and erythrocytes are 107.4 ± 20.5 ng/ml and 1285.0 ± 1363.0 ng/ml, respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Nephropathic cystinosis is characterized by abnormal intralysosomal accumulation of cystine throughout the body, causing irreversible damage to various organs, particularly the kidneys. Cysteamine, the currently available treatment, can reduce lysosomal cystine and postpone disease progression. However, cysteamine poses serious side effects and does not address all of the symptoms of cystinosis. To screen for new treatment options, a rapid and reliable high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method was developed to quantify cystine in conditionally immortalized human proximal tubular epithelial cells (ciPTEC). The ciPTEC were treated with N‐ethylmaleimide, lysed and deproteinized with 15% (w/v) sulfosalicylic acid. Subsequently, cystine was measured using deuterium‐labeled cystine‐D4, as the internal standard. The assay developed demonstrated linearity to at least 20 μmol/L with a good precision. Accuracies were between 97.3 and 102.9% for both cell extracts and whole cell samples. Cystine was sufficiently stable under all relevant analytical conditions. The assay was successfully applied to determine cystine levels in both healthy and cystinotic ciPTEC. Control cells showed clearly distinguishable cystine levels compared with cystinotic cells treated with or without cysteamine. The method developed provides a fast and reliable quantification of cystine, and is applicable to screen for potential drugs that could reverse cystinotic symptoms in human kidney cells.  相似文献   

10.
A simple, sensitive, and rapid method for determination of L‐trantinterol in rat plasma was developed for the first time by using LC coupled to MS/MS based on chiral stationary phase. A baseline separation of the enantiomers of trantinterol was achieved on a Chirobiotic V column, using a mixture of acetonitrile–methanol–ammonia–acetic acid (80:20:0.01:0.02, v/v/v/v) as the mobile phase. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via ESI. The calibration curve was linear in concentration range from 0.270 to 108 ng/mL in plasma with the lower limit of quantification of 0.270 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 10.9% and the accuracy (relative error) was from 2.6 to 9.2% at all quality control levels. The method has been successfully applied to a study of L‐trantinterol pharmacokinetics in rats.  相似文献   

11.
Astragaloside III (AST III), a naturally occurring saponin compound isolated from Radix Astragali, has been demonstrated to have anti‐gastric ulcer, immunomodulatory and antitumor effects. To evaluate its pharmacokinetics in rats, a rapid, sensitive and specific high‐performance liquid chromatography–tandem mass spectrometric (HPLC‐MS/MS) method has been developed and validated for the quantification of astragaloside III in rat plasma. Samples were pretreated using a simple protein precipitation with methanol–acetonitrile (50:50, v/v) and the chromatographic separation was performed on a C18 column by a gradient elution using a mobile phase consisting of water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid. Astragaloside III and the internal standard (buspirone) were detected using a tandem mass spectrometer in positive multiple reaction monitoring mode. Method validation revealed excellent linearity over the range of 5.00–5000 ng/mL together with satisfactory intra‐ and inter‐day precision, accuracy and recovery. Stability testing showed that astragaloside III spiked into rat plasma was stable for 24 h at 20°C temperature, for up to 30 days at ?80°C, and during three freeze–thaw cycles. The method was successfully used to investigate the pharmacokinetic profile of AST III after oral (10 mg/kg) and intravenous (1.0 mg/kg) administration in rats. The oral absolute bioavailability of AST III was calculated to be 4.15 ± 0.67% with an elimination half‐life value of 2.13 ± 0.11 h, suggesting its poor absorption and/or strong metabolism in vivo. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A sensitive and accurate HPLC‐MS/MS method was developed for the simultaneous determination of dextromethorphan, dextrorphan and chlorphenamine in human plasma. Three analytes were extracted from plasma by liquid–liquid extraction using ethyl acetate and separated on a Kromasil 60‐5CN column (3 µm, 2.1 × 150 mm) with mobile phase of acetonitrile–water (containing 0.1% formic acid; 50:50, v/v) at a flow rate of 0.2 mL/min. Quantification was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The calibration curve was linear over the range of 0.01–5 ng/mL for dextromethorphan, 0.02–5 ng/mL for dextrorphan and 0.025–20 ng/mL for chlorphenamine. The lower limits of quantification for dextromethorphan, dextrorphan and chlorphenamine were 0.01, 0.02 and 0.025 ng/mL, respectively. The intra‐ and inter‐day precisions were within 11% and accuracies were in the range of 92.9–102.5%. All analytes were proved to be stable during sample storage, preparation and analytic procedures. This method was first applied to the pharmacokinetic study in healthy Chinese volunteers after a single oral dose of the formulation containing dextromethorphan hydrobromide (18 mg) and chlorpheniramine malaeate (8 mg). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
Drugs deposited in human teeth are well preserved; the spectrum of toxicological investigations may therefore be supplemented by an analysis method for drugs in teeth. A liquid chromatography–electrospray ionization tandem mass spectrometry assay for the detection and quantification of basic drugs of abuse in bovine dentin samples was developed and validated. The drugs and metabolites amphetamine, methamphetamine, methylenedioxymethylamphetamine, methylenedioxyethylamphetamine, codeine, morphine, cocaine and benzoylecgonine were extracted from 50 mg ground dentin powder by ultrasonication for 60 min in methanol 3 times. The extracts were analyzed on a triple‐quadrupole mass‐spectrometer in multiple reaction monitoring mode. The method was validated and proved to be accurate, precise, selective, specific and stable with good linearity within the calibration range and a lower limit of quantification of 10 to 20 pg/mg. To artificially load bovine dentin samples with drugs, the natural process of de‐ and remineralization in the oral cavity was mimicked by a pH‐cycling experiment. The artificially drug‐loaded dentin samples showed drug concentrations of 20 to 80 pg/mg. The method can be applied in further in vitro experiments as well as in post‐mortem cases, especially where limited sample tissue is available. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive, rapid and specific high‐performance liquid chromatography tandem mass spectrometry method (HPLC‐MS/MS) was developed to determine ecliptasaponin A in rat plasma and tissues after oral administration. Ginsenoside Rg1 was used as the internal standard (IS). The plasma and tissues samples were prepared by liquid‐liquid extraction with ethyl acetate and separated on an Eclipse Plus C18 column (2.1 mm × 150 mm, 5 µm) at a flow rate of 0.4 mL/min using acetonitrile and water (containing 0.05% acetic acid) as the mobile phase. The tandem mass detection was carried out with eletrospray ionization in negative mode. Quantification was performed by using multiple reaction monitoring (MRM), which monitored the fragmentation of m/z 633.4→587.2 for ecliptasaponin A and m/z 859.4→637.4 for the IS. The calibration curves obtained were linear in different matrices, and the lower limit of quantification (LLOQ) achieved was 0.5 ng/mL both for rat plasma and tissues. The intra‐ and inter‐day precisions were below 15%. This method was successfully applied to pharmacokinetic study of ecliptasaponin A in rat plasma and tissues after oral administration. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
Major depressive disorder is a severe, life‐threatening and highly prevalent psychiatric disorder. A high percentage of people suffering from depression are characterized by hyperactivity of the hypothalamic–pituitary–adrenal axis, resulting in plasma glucocorticoid (cortisol in human and corticosterone in rodent) elevations. Glucocorticoid is a critical molecule in the onset of pathology of depression. A simple, highly sensitive and specific method based on ultra‐fast liquid chromatography–tandem mass spectrometry method has been developed for the quantitation of corticosterone in mouse plasma for the first time, which provides technical support for the high‐throughput measurement for clinical determination of corticosterone in biological samples. Samples were spiked with methanol to precipitate the protein, and then chromatographed on an Agilent Zorbax Eclipse Plus C18 (100 × 2.1 mm,1.8 µm) column by linear gradient elution with methanol and 0.1% formic acid as the mobile phase within 5 min. The detection of corticosterone was performed on ultra‐fast liquid chromatography–triple quadrupole tandem mass spectrometry in the positive ion. The ions [M + H]+ m/z 347.2 → m/z 311.1 for corticosterone and [M + H]+ m/z 363.2 → m/z 327.2 for hydrocortisone (internal standard) were used for quantitative determination. The lower quantification limit for corticosterone was 1 ng/mL. The validated method was successfully applied to the quantitation of corticosterone in mouse plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
In this work, the interior‐walls decyl‐perfluorinated functionalized magnetic mesoporous microspheres (F17–Fe3O4@mSiO2) were synthesized for the first time, and applied as adsorbents to extract and concentrate perfluorinated compounds (PFCs) from water samples. The fluorous functionalized interior pore‐walls contributed to the high‐selective preconcentration of PFCs due to fluorous affinity; and abundant silanol groups on the exterior surface of microspheres contributed to the good dispersibility in water sample. Four kinds of PFCs were selected as model analytes, including perfluorooctanoic acid, perfluorononanoic acid, perfluorododecanoic acid, and perfluorooctane sulphonate. In addition, UHPLC‐ESI/MS/MS was introduced to the fast and sensitive detection of the analytes after sample pretreatment. Important parameters of the extraction procedure were optimized, including salinity, eluting solvent, the amount of F17–Fe3O4@mSiO2 microspheres, and extraction time. The optimized procedure took only 10 min to extract analytes with high recoveries and merely 800‐μL acetonitrile to elute analytes from the magnetic adsorbents. Validation experiments showed good linearity (0.994–0.998), precision (2.6–7.6%), high recovery (93.4–105.7%) of the proposed method, and the limits of detection were from 0.008 to 0.125 μg/L. The F17–Fe3O4@mSiO2 magnetic microspheres have the advantages of great dispersibility in aqueous solution, high specificity of extraction, large surface area, and efficient separation ability. The results showed that the proposed method based on F17–Fe3O4@mSiO2 microspheres is a simple, fast, and sensitive tool for the analysis of PFCs in water sample.  相似文献   

17.
A new method for the analysis of cycloserine (4‐amino‐3‐isoxazolidinone, CYC) in rat microdialysis samples has been developed. This method consists of derivatizing the CYC with benzoyl chloride, which transforms primary amines into highly stable derivatives. An attractive feature of this method was that the derivatization reaction is straightforward and can be completed within 10 min. The formed derivative, in contrast to the non‐derivatized analyte, exhibited increased chromatographic retention and decreased matrix effects resulting from the co‐elution of other components using reversed‐phase liquid chromatography and on‐line switching. Detection on a quadrupole–linear ion trap mass spectrometer (AB3200 Q‐Trap) was performed using electrospray tandem mass spectrometry in multiple reaction monitoring mode. Various derivatization parameters were optimized in order to improve chromatographic separation and minimize ion suppression. In particular, the benzoylation reaction was improved to enhance the reproducibility and sensitivity of the chromatographic method. The transition m/z 207.1 → 105.1 was acquired to monitor the CYC derivatization products. The method was fully validated for its sensitivity, selectivity, matrix effect and stability. A good linearity over the selected range (r > 0.99, range = 22–2200 mg/L), as well as accuracy and precision within ±7% of the target values, was obtained. The assay described herein was successfully applied to quantitatively measure CYC in the lung and blood of anesthetized rats.  相似文献   

18.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

19.
A specific, sensitive and rapid method based on high performance liquid chromatography coupled to tandem mass spectrometry (HPLC‐MS/MS) was developed for the determination of pseudo‐ginsenoside GQ in human plasma. Liquid–liquid extraction was used to isolate the analyte from biological matrix followed by injection of the extracts onto a C8 column with isocratic elution. Detection was carried out on a triple quadrupole tandem mass spectrometer (API‐4000 system) in multiple reaction monitoring mode using negative electrospray ionization. The mobile phase consisted of methanol–10 mm ammonium acetate (90:10, v/v) and the flow rate was 0.3 mL/min. The method was validated over the concentration range of 5.0–5000.0 ng/mL for plasma. Inter‐ and intra‐day precisions (relative standard deviation) were all within 15% and the accuracy (relative error) was ≤9.4%. The lower limit of quantitation was 5.0 ng/mL. The pseudo‐ginsenoside GQ was stable after 8 h at room temperature, 24 h at autosampler and three freeze–thaw cycles (from ?30 to 25 °C). The method was successfully applied to the pharmacokinetic study of pseudo‐ginsenoside GQ in healthy Chinese volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
Anacetrapib is a potent and selective CETP inhibitor and is undergoing phase III clinical trials for the treatment of dyslipidemia. A simple and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for the quantification of anacetrapib in rat plasma was developed and validated using an easily purchasable compound, chlorpropamide, as an internal standard (IS). A minimal volume of rat plasma sample (20 μL) was prepared by a single‐step deproteinization procedure with 80 μL of acetonitrile. Chromatographic separation was performed using Kinetex C18 column with a gradient mobile phase consisting of water and acetonitrile containing 0.1% formic acid at a flow rate of 0.3 mL/min. Mass spectrometric detection was performed using selected reaction monitoring modes at the mass/charge transitions m/z 638 → 283 for anacetrapib and m/z 277 → 175 for IS. The assay was validated to demonstrate the selectivity, linearity, precision, accuracy, recovery, matrix effect and stability. The lower limit of quantification was 5 ng/mL. This LC‐MS/MS assay was successfully applied in the rat plasma protein binding and pharmacokinetic studies of anacetrapib. The fraction of unbound anacetrapib was determined to be low (ranging from 5.66 to 12.3%), and the absolute oral bioavailability of anacetrapib was 32.7%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号