首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
提高维甲酸毛细管电泳分析灵敏度的微柱固相萃取法研究   总被引:2,自引:0,他引:2  
本文发展了一种适于复杂样品预处理的微柱固相萃取装置。该装置与毛细管电泳结合用于13-顺-维甲酸和全反式-维甲酸异构体的分析,灵敏度可提高100倍以上。维甲酸异构体的微柱固相萃取过程包括柱老化、上样、洗涤、洗脱以及柱再生等步骤。将该法用于加标血浆样品中的维甲酸分析,得到满意的结果。  相似文献   

2.
Porous polymer monoliths have been used to develop an online solid‐phase extraction with liquid chromatography method for determination of dopamine in urine as well as for a continuous monitoring of dopamine in flowing system. A polymerization mixture containing 4‐vinylphenylboronic acid monomer has been used to prepare a trapping column based on specific ring formation reaction with dopamine cis‐diol functionality. Additionally, a monolithic stationary phase with zwitterion functionality has been used to prepare capillary column for the separation of dopamine. Experimental conditions including molarity, pH, and flow rate of the loading buffer together with a valve switching time have been optimized to provide the highest recovery for dopamine. Experimental setup has been used to determine dopamine in a urine. By using both calibration curve and standard addition method, the dopamine level was determined to be 1.19 and 1.28 mg/L, respectively. Further, we have used experimental design to optimize coupling of two extraction monolithic loops to separation capillary column with monolithic phase for a comprehensive monitoring of dopamine. After multivariate analysis, sample loading flow‐rate and a flow‐rate of flushing buffer were selected as the most significant variables. Optimized experimental setup was applied to continuously monitor dopamine degradation.  相似文献   

3.
This paper reports the utilization of solid phase extraction and the reversed‐phase high‐performance liquid chromatography (RP‐HPLC) for the determination of six transition metal ions (iron, cobalt, nickel, copper, zinc and manganese) in biological samples. The samples were digested by microwave digestion. The iron, cobalt, nickel, copper, zinc and manganese ions in the digested samples can react with 2‐(2‐quinolinylazo)‐5‐diethylaminophenol (QADEAP) to form colored chelates in pH 4.0 acetic acid‐sodium acetic buffer solutions and cetyl trimethylammonium bromide (CTMAB) medium. These chelates were enriched by solid phase extraction with C18 cartridge. Then the chelates were separated on a Waters Nova‐Pak‐C18 column (3.9 × 150 mm, 5 μm) by gradient elution with methanol (containing 0.5% of acetic acid and 0.1% of CTMAB) and 0.05 mol/L pH 4.0 acetic acid‐sodium acetic buffer solution (containing 0.1% of CTMAB) as mobile phase at a flow rate of 0.5 mL/min. The detection limits of iron, cobalt, nickel, copper, zinc and manganese are 3 ng/L, 4 ng/L, 2 ng/L, 4 ng/L, 8 ng/L, 10 ng/L, respectively. This method was applied to the determination of iron, cobalt, nickel, copper, zinc and manganese in biological samples with good results.  相似文献   

4.
Novel, fast, selective, eco‐friendly and reproducible solid‐phase membrane tip extraction and gas chromatography with mass spectrometry methods were developed and validated for the analysis of triazine herbicides (atrazine and secbumeton) in stream and lake waters. The retention times of atrazine and secbumeton were 7.48 and 8.51 min. The solid‐phase membrane tip extraction was carried out in semiautomated dynamic mode on multiwall carbon nanotubes enclosed in a cone‐shaped polypropylene membrane cartridge. Acetone and methanol were found as the best preconditioning and desorption solvents, respectively. The extraction and desorption times for these herbicides were 15.0 and 10.0 min, respectively. The percentage recoveries of atrazine and secbumeton were 88.0 and 99.0%. The linearity range was 0.50–80.0 μg/L (r2 > 0.994), with detection limits (<0.47 μg/L, S/N = 3) and good reproducibility (<8.0%). The ease of operation, eco‐friendly nature, and low cost of solid‐phase membrane tip extraction made these methods novel. The Solid‐phase membrane tip extraction method was optimized by considering the effect of extraction time, desorbing solvents and time.  相似文献   

5.
Ionic liquids immobilized on magnetic nanoparticles were prepared by an efficient microwave‐assisted synthesis method, and the properties of the ionic liquids were tuned based on the aromatic functional modification of its anion through a simple metathesis reaction. The novel as‐synthesized magnetic materials were characterized by various instrumental techniques. The magnetic nanoparticles have been utilized as adsorbents for the extraction of four sulfonylurea herbicides in tea samples, in combination with high‐performance liquid chromatography analysis. Significant extraction parameters, including type and volume of desorption solvent, extraction time, amount of adsorbent, and ionic strength were investigated. Under the optimum conditions, good linearity was obtained in the concentration range of 1–150 μg/L for metsulfuron‐methyl and bensulfuron‐methyl, and 3–150 μg/L for sulfometuron‐methyl and chlorimuron‐ethyl, with correlation coefficients R2 > 0.9987. Low limits of detection were obtained ranging from 0.13 to 0.81 μg/L. The relative standard deviations were 1.8–3.9%. Comparisons of extraction efficiency with conventional solid‐phase extraction equipped with a commercial C18 cartridge were performed. Results indicated that magnetic solid‐phase extraction is simple, time‐saving, efficient and inexpensive with the reusability of adsorbents. The proposed method has been successfully used to determine sulfonylurea herbicides from tea samples with satisfactory recoveries of 80.5–104.2%.  相似文献   

6.
An orthogonal two‐dimensional solid‐phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed‐phase liquid chromatography material (C18) and a weak cation‐exchange material (TGA) were integrated in a single solid‐phase extraction cartridge. The feasibility of two‐dimensional clean‐up procedure that experienced two‐step adsorption, two‐step rinsing, and two‐step elution was systematically investigated. Based on the orthogonality of reversed‐phase and weak cation‐exchange procedures, the two‐dimensional solid‐phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed‐phase solid‐phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation‐exchange solid‐phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two‐dimensional clean‐up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk.  相似文献   

7.
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine.  相似文献   

8.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

9.
This work presents a method to separate polar naphthalenesulfonate (NS) isomers by capillary zone electrophoresis (CZE) with ultraviolet detection in industrial effluents and river water samples. The method involves extraction of samples by a polystyrene‐divinylbenzene copolymer (PS‐DVB) solid‐phase extraction (SPE) cartridge. The most effective CZE separation conditions were obtained in 20 mM borate buffer with 30% acetonitrile at pH 9.0 and 30 °C. The method proposed herein provides a high precision and sensitivity for NS isomers, to quantitation at ≤ 1.0 μg/L in 200 mL of the water samples. Recovery of the NS isomers in spiked water samples ranged from 73% to 87% while RSD ranging from 5.6 to 9.7%. The analysis of industrial effluents and river water samples was performed and naphthalene‐2‐sulfonate was found as a major pollutant. The difficulties in quantitating and identifying analytes in complex environmental samples can be resolved by using an internal standard response factor to calculate concentrations and relative migration times for peak confirmation.  相似文献   

10.
Monoamine acidic metabolites in biological samples are essential biomarkers for the diagnosis of neurological disorders. In this work, acrylamide‐functionalized graphene adsorbent was successfully synthesized by a chemical functionalization method and was packed in a homemade polyether ether ketone micro column as a micro‐solid‐phase extraction unit. This micro‐solid‐phase extraction unit was directly coupled to high‐performance liquid chromatography to form an online system for the separation and analysis of three monoamine acidic metabolites including homovanillic acid, 5‐hydroxyindole‐3‐acetic acid, and 3,4‐dihydroxyphenylacetic acid in human urine and plasma. The online system showed high stability, permeability, and adsorption capacity toward target metabolites. The saturated extraction amount of this online system was 213.1, 107.0, and 153.4 ng for homovanillic acid, 5‐hydroxyindole‐3‐acetic acid, and 3,4‐dihydroxyphenylacetic acid, respectively. Excellent detection limits were achieved in the range of 0.08–0.25 μg/L with good linearity and reproducibility. It was interesting that three targets in urine and plasma could be actually quantified to be 0.94–3.93 μg/L in plasma and 7.15–19.38 μg/L in urine. Good recoveries were achieved as 84.8–101.4% for urine and 77.8–95.1% for plasma with the intra‐ and interday relative standard deviations less than 9.3 and 10.3%, respectively. This method shows great potential for online analysis of trace monoamine acidic metabolites in biological samples.  相似文献   

11.
Solid‐phase membrane micro‐tip extraction (SPMMTE) and capillary electrophoresis (CE) methods were developed and validated for analysis of chloramphenicol in human plasma and urine samples. Iron composite nanoparticles were prepared using green technology. CE was carried out using a silica capillary (60 cm × 50 μm i.d.), phosphate buffer (50 mm , 8.0 pH)–acetonitrile (95:5, v/v) as the background electrolyte, 10 kV voltage, 280 nm detection, 20 s injection time and 27 ± 1°C temperature. Frusemide was used as an internal standard. The values of migration time, electrophoretic mobility, electrophoretic velocity and theoretical plates of chloramphenicol were 12.254 min, 4.44 × 10, 7.41 × 10 and 11,227. The limits of detection and quantitation of chloramphenicol were 0.1 and 1.0 μg/mL. Recovery of chloramphenicol in the standard solution was 95%. Solid‐phase membrane micro‐tip extraction and capillary electrophoresis methods may be used to analyze chloramphenicol in human plasma and urine samples of any patient.  相似文献   

12.
Abstract

A method is described for screening of the cocaine metabolite benzoylecgonine in urine at 0.2 μ/ml using a Cyclobond cyclodex?trin solid phase extraction cartridge and high performance thin layer chromatography. Results are compared with those obtained using liquid-liquid and diatomaceous earth column extraction and C-18 solid phase extraction.  相似文献   

13.
A novel capillary zone electrophoresis separation coupled to electro spray ionization time‐of‐flight mass spectrometry method was developed for the simultaneous analysis of six toxic alkaloids: brucine, strychnine, atropine sulfate, anisodamine hydrobromide, scopolamine hydrobromide and anisodine hydrobromide in human plasma and urine. To obtain optimal sensitivity, a solid‐phase extraction method using Oasis MCX cartridges (1 mL, 30 mg; Waters, USA) for the pretreatment of samples was used. All compounds were separated by capillary zone electrophoresis at 25 kV within 12 min in an uncoated fused‐silica capillary of 75 μm id × 100 cm and were detected by time‐of‐flight mass spectrometry. This method was validated with regard to precision, accuracy, sensitivity, linear range, limit of detection (LOD), and limit of quantification (LOQ). In the plasma and urine samples, the linear calibration curves were obtained over the range of 0.50–100 ng/mL. The LOD and LOQ were 0.2–0.5 ng/mL and 0.5–1.0 ng/mL, respectively. The intra‐ and interday precision was better than 12% and 13%, respectively. Electrophoretic peaks could be identified by mass analysis.  相似文献   

14.
An automated online solid‐phase extraction with liquid chromatography and tandem mass spectrometry method was developed and validated for the detection of clenbuterol, salbutamol, and ractopamine in food of animal origin. The samples from the food matrix were pretreated with an online solid‐phase extraction cartridge by Oasis MCX for <5 min after acid hydrolysis for 30 min. The peak focusing mode was used to elute the target compounds directly onto a C18 column. Chromatographic separation was achieved under gradient conditions using a mobile phase composed of acetonitrile/0.1% formic acid in aqueous solution. Each analyte was detected in two multiple reaction monitoring transitions via an electrospray ionization source in a positive mode. The relative standard deviations ranged from 2.6 to 10.5%, and recovery was between 76.7 and 107.2% at all quality control levels. The limits of quantification of three β‐agonists were in the range of 0.024–0.29 μg/kg in pork, sausage, and milk powder, respectively. This newly developed method offers high sensitivity and minimum sample pretreatment for the high‐throughput analysis of β‐agonist residues.  相似文献   

15.
This article describes the development of a rapid, simple, and sensitive analytical approach for the simultaneous determination of serotonin (5‐hydroxytryptamine) and creatinine in urine samples by combining two ultrasound‐assisted emulsification microextractions (USAEMEs) in series with on‐column stacking in CE. This serial USAEME procedure comprises analytes extraction from the donor solution (urine with K2CO3 additive) to an organic solvent followed by a back‐extraction from the organic phase into a small volume of hydrochloric acid. After 15 min of sample pretreatment, the acidic acceptor solution was analyzed directly on CE in the mode of capillary zone electrophoresis. The adoption of HCl as the acceptor phase not only provided effective back‐extraction but also facilitated pH‐mediated on‐column stacking in CE analysis. About 360‐fold sensitivity enhancement was achieved for serotonin detection. The limits of detection were 7.9 nM for serotonin and 13.3 μM for creatinine, respectively. Satisfactory results were obtained with respect to precision and recovery. The proposed method has been demonstrated to be convenient and effective for the analysis of real urine samples. We believe that two USAEMEs in series will find wide applications in simplified sample pretreatment prior to CE analysis.  相似文献   

16.
A simple and sensitive analytical method for four isomers of glycopyrrolate in rat plasma was developed using cation‐selective exhaustive injection‐sweeping cyclodextrin‐modified electrokinetic chromatography (CSEI‐Sweeping‐CDEKC) for online enrichment combined with dispersive micro‐solid‐phase extraction pretreatment. The CSEI‐Sweeping‐CDEKC was conducted on an uncoated fused silica capillary (40.2 cm × 75 μm) with an applied voltage of –20 kV. The electrophoretic analysis was carried out in 30 mM phosphate solution at pH 2.0 containing 20 mg/mL sulfated‐β‐cyclodextrin and 5% acetonitrile. Under these optimized conditions, the detection limit for racemic glycopyrrolate was found to be 2.0 ng/mL and this method could increase 495‐fold detection sensitivity compared with the traditional injection method. Additionally, the parameters that affected the extraction efficiency of dispersive micro‐solid‐phase extraction were also examined systematically. The glycopyrrolate isomers in rat plasma samples as low as 0.0625 μg/mL were able to be separated and detected by capillary electrophoresis with the aid of CSEI‐sweeping. The findings of this study show that the dispersive micro‐solid‐phase extraction pretreatment coupled with CSEI‐Sweeping‐CDEKC is a rapid and convenient method for analyzing glycopyrrolate isomers in rat plasma.  相似文献   

17.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

18.
In this study, magnetized MOF‐74 (Ni) was prepared using an ultrasound‐assisted synthesis method. This novel functional magnetic adsorbent was characterized using various techniques. Using the prepared material as adsorbents, a magnetic solid‐phase extraction method coupled with high‐performance liquid chromatography was proposed for determining four phthalate esters in Chinese liquor samples. The extraction parameters, including solution pH, adsorbent amount, extraction time, and eluent type and volume, were optimized. Under the optimized conditions, proposed method showed good linearity within the range of 1.53–200 μg/L for diphenyl phthalate, 2.03–200 μg/L for butyl benzyl phthalate, 7.02–200 μg/L for diamyl phthalate, and 6.03–200 μg/L for dicyclohexyl phthalate, with correlation coefficients > 0.9944, low limits of detection (0.46–2.10 μg/L, S/N = 3), and good extraction repeatability (relative standard deviations of 3.7%, n = 6). This method was successfully used to analyze phthalate esters in Chinese liquor samples with recoveries of 74.4–104.8%. Two phthalate esters were detected in two samples, both at concentrations that satisfied the Chinese national standard, indicating this method has practical application prospects. The extraction efficiency of this method was also compared with conventional solid‐phase extraction using commercial C18 cartridges. The results demonstrated that the proposed magnetic solid‐phase extraction is a simple, time‐saving, efficient, and low‐cost method.  相似文献   

19.
A rapid dispersive micro‐solid phase extraction (D‐μ‐SPE) combined with LC/MS/MS method was developed and validated for the determination of ketoconazole and voriconazole in human urine and plasma samples. Synthesized mesoporous silica MCM‐41 was used as sorbent in d ‐μ‐SPE of the azole compounds from biological fluids. Important D‐μ‐SPE parameters, namely type desorption solvent, extraction time, sample pH, salt addition, desorption time, amount of sorbent and sample volume were optimized. Liquid chromatographic separations were carried out on a Zorbax SB‐C18 column (2.1 × 100 mm, 3.5 μm), using a mobile phase of acetonitrile–0.05% formic acid in 5 mm ammonium acetate buffer (70:30, v /v). A triple quadrupole mass spectrometer with positive ionization mode was used for the determination of target analytes. Under the optimized conditions, the calibration curves showed good linearity in the range of 0.1–10,000 μg/L with satisfactory limit of detection (≤0.06 μg/L) and limit of quantitation (≤0.3 μg/L). The proposed method also showed acceptable intra‐ and inter‐day precisions for ketoconazole and voriconazole from urine and human plasma with RSD ≤16.5% and good relative recoveries in the range 84.3–114.8%. The MCM‐41‐D‐μ‐SPE method proved to be rapid and simple and requires a small volume of organic solvent (200 μL); thus it is advantageous for routine drug analysis.  相似文献   

20.
The ultrasound‐assisted ionic liquid foam flotation solid‐phase extraction of sulfonylurea herbicides in milk was developed and validated. The proteins and lipids were isolated from the sample matrix by adding salt and adjusting the pH value. The target analytes eluted from the solid‐phase extraction cartridge were determined by high‐performance liquid chromatography. Some experimental parameters, including the pH value of sample solution, amount of NaCl, ionic liquid type, extraction time, flow rate of carrier gas, flotation time, and solid‐phase extraction cartridge type were investigated and optimized. Under the optimized experimental conditions, the limits of detection for metsulfuron, pyrazosulfuron, chlorimuron‐ethyl, and nicosulfuron were 1.3, 0.6, 0.7, and 1.1 μg/L, respectively. When the present method was applied to the analysis of milk samples the recoveries of the analytes ranged from 84.3 to 105.2% and relative standard deviations were >5.7%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号