首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

2.
The validity of the extended Tanaka column characterization procedure against the retention behavior of 101 analytes of widely differing properties chromatographed on five differing stationary phase chemistries has been established using a chemometric technique called principal component analysis (PCA). It was concluded that the simple and conveniently determined column characterization parameters covered the same space in the PCA loading plot as the retention times for the 101 differing analytes. This confirms that the ten column characterization parameters of the extended Tanaka protocol encode the same information as the retention times of the 101 analytes. Significant selectivity differences were observed between stationary phases and the mobile‐phase modifiers – MeOH and MeCN. PCA contribution plots served as a convenient way to highlight specific selectivity differences between stationary phases. logD values exhibited a poor correlation with retention indicating that retention in RP‐LC is not solely dictated by the analyte's hydrophobicity. The use of MeOH was found to generate greater selectivity differences with the five stationary phases than when MeCN is used.  相似文献   

3.
Reversed-phase high-performance liquid chromatography (RP-HPLC) was used for the separation of 3-hexylthiophene oligomers in the range of 3 to 30 monomeric units, while systematically varying stationary and mobile phases. A set of different columns was chosen, covering a broad range of silica types, pore sizes and bonding chemistry. Mobile phases of tetrahydrofuran (THF) combined with water, acetonitrile (ACN) or methanol (MeOH) were used. Although differences between columns were small, a higher selectivity correlated with a lower hydrophobicity parameter from the Galushko column test. The model of Jandera, based on the linear solvent strength model of Snyder, was used to describe the retention of the oligomers in gradient mode. This gave information about selectivities on different stationary phases similar to the hydrophobicity parameter. Contrary to the stationary phase, the mobile phase had a major influence on the selectivity. The THF-water combination gave much higher selectivities compared to THF combined with MeOH or ACN. Using the aqueous mobile phase even enabled separation of different isomers. Determination of thermodynamic parameters for the model compounds showed that retention of the different isomers was mainly determined by the orientation of the side chains at both ends of the chain. An additional repeating unit in the middle of the polymer backbone gave a similar contribution to retention, irrespective of the orientation of its side chain. Three model isomers were separated by preparative RP-HPLC and identified by proton nuclear magnetic resonance spectroscopy. The combination of subsequent preparative size-exclusion chromatography, RP-HPLC and matrix-assisted laser desorption ionization time-of-flight mass spectrometry enabled the identification of the two major oligomeric series in the sample as the regioregular product with one bromine end group and, in smaller amounts, a regioirregular product with two bromine end groups. reserved.  相似文献   

4.
The retention behavior of a set of polar peptides separated on a silica hydride stationary phase was examined with a capillary HPLC system coupled to ESI‐MS detection. The mobile phases consisted of formic acid or acetic acid/acetonitrile/water mixtures with the acetonitrile content ranging from 5 to 80% v/v. The effects on peptide retention of these two acidic buffer additives and their concentrations in the mobile phase were systematically investigated. Strong retention of the peptides on the silica hydride phase was observed with relatively high‐organic low‐aqueous mobile phases (i.e. under aqueous normal‐phase conditions). However, when low concentrations of acetic acid were employed as the buffer additive, strong retention of the peptides was also observed even when high aqueous content mobile phases were employed. This unique feature of the stationary phase therefore provides an opportunity for chromatographic analysis of polar peptides with water‐rich eluents, a feature usually not feasible with traditional RP sorbents, and thus under conditions more compatible with analytical green chemistry criteria. In addition, both isocratic and gradient elution procedures can be employed to optimize peptide separations with excellent reproducibility and resolution under these high aqueous mobile phase conditions with this silica hydride stationary phase.  相似文献   

5.
Summary Variations in retention and selectivity have been studied in cyano, phenyl and octyl reversed bonded phase HPLC columns. The retention of toluene, phenol, aniline and nitrobenzene in these columns has been measured using binary mixtures of water and methanol, acetonitrile or tetrahydrofuran mobile phases in order to determine the relative contributions of proton donor-proton acceptor and dipole-dipole interactions in the retention process. Retention and selectivity in these columns was correlated with polar group selectivities of mobile phase organic modifiers and the polarity of the bonded stationary phases. In spite of the prominent role of bonded phase volume and residual silanols in the retention process, each column exhibited some unique selectivities when used with different organic modifiers.  相似文献   

6.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

7.
A new reversed stationary phase was prepared, based on thermal immobilization of trimethoxysilylpropyl modified polyethyleneimine onto silica particles endcapped with octadecyl molecules. The physicochemical and morphological properties of the stationary phase were characterized by solid state cross-polarization and magic angle spinning 29Si nuclear magnetic resonance, infrared spectroscopy, porosimetry, and elemental analysis. For the studies on reversed phase high-performance liquid chromatography (HPLC) retention, separation of the established Tanaka and Engelhardt test mixtures was performed. The stationary phase showed a typical partition mechanism for the reversed phase; however, the low hydrophobicity required a low organic content solvent in the mobile phase for chromatographic separation of more hydrophobic compounds. The stationary phase also showed low residual silanol activity for the elution of basic compounds due to the protection offered by octadecyl endcapped molecules and the competition provided by the imine groups of the polymeric layer. The proposed stationary phase possesses interesting selectivity and is convenient for applications requiring the separation of more retentive compounds in conventional HPLC columns using more aqueous mobile phases.  相似文献   

8.
We prepared 0.53 and 0.32 mm id monolithic microcolumns by in situ copolymerization of a zwitterionic sulfobetaine functional monomer with bisphenol A glycerolate dimethacrylate (BIGDMA) and dioxyethylene dimetacrylate crosslinkers. The columns show a dual retention mechanism (hydrophilic‐interaction mode) in acetonitrile‐rich mobile phases and RP in highly aqueous mobile phases. The new 0.53 mm id columns provided excellent reproducibility, retention, and separation selectivity for phenolic acids and flavonoids. The new zwitterionic monolithic columns are highly orthogonal, with respect to alkyl silica stationary phases, not only in the hydrophilic‐interaction mode but also in the RP mode. The optimized monolithic zwitterionic microcolumn of 0.53 mm id was employed in the first dimension, either in the aqueous normal‐phase or in the RP mode, coupled with a short nonpolar core‐shell column in the second dimension, for comprehensive 2D LC separations of phenolic and flavonoid compounds. When the 2D setup with the sulfobetaine–BIGDMA column was used for repeated sample analysis, with alternating gradients of decreasing (hydrophilic‐interaction mode), and increasing (RP mode) concentration of acetonitrile on the sulfobetaine–BIGDMA column in the first dimension, useful complementary information on the sample could be obtained.  相似文献   

9.
Strongly polar phenolic acids are weakly retained and often poorly separated in reversed-phase (RP) liquid chromatography. We prepared zwitterionic polymethacrylate monolithic columns for micro-HPLC by in situ co-polymerization in fused-silica capillaries. The capillary monolithic columns prepared under optimized polymerization conditions show some similarities with the conventional particulate commercial ZIC-HILIC silica-based columns, however have higher retention and better separation selectivity under reversed-phase conditions, so that they can be employed for dual-mode HILIC-RP separations of phenolic acids on a single column. The capillary polymethacrylate monolithic sulfobetaine columns show excellent thermal stability and improved performance at temperatures 60–80 °C. The effects of the operation conditions on separation were investigated, including the type and the concentration of the organic solvent in the aqueous-organic mobile phase (acetonitrile and methanol), the ionic strength of the acetate buffer and temperature. While the retention in the RP mode decreases at higher temperatures in mobile phases with relatively low concentrations of acetonitrile, it is almost independent of temperature at HILIC conditions in highly organic mobile phases. The best separation efficiency can be achieved using relatively high acetate buffer ionic strength (20–30 mmol L−1) and gradient elution with alternately increasing (HILIC mode) and decreasing (RP mode) concentration of aqueous buffer in aqueous acetonitrile. Applications of the monolithic sulfobetaine capillary columns in alternating HILIC-RP modes are demonstrated on the analysis of phenolic acids in a beer sample.  相似文献   

10.
11.
Immobilized artificial membranes (IAMs) prepared from phosphatidylcholine analogs are used as stationary phases in liquid chromatography systems to model drug partitioning between an aqueous phase (mobile phase) and a cell membrane (IAM column). Two different chromatographic models, which describe retention as a function of solute and column-mobile phase properties, have been applied to characterization of an IAM and two reversed phase C18 columns (Waters XTerra MSC18 and XTerra RP18) with acetonitrile-water mobile phases. The comparison of the results shows that the phosphatidylcholine group makes IAM column more polar than both XTerra columns, specially in terms of hydrogen-bond acceptor ability. XTerra RP18 is slightly more polar than XTerra MSC18 because of the presence of the embedded carbamate polar group.  相似文献   

12.
It was demonstrated that the characteristics of stationary phases for reversed-phase chromatography can be compared by analyzing the retention of several compounds belonging to a homologous series during elution with one and the same composition of mobile phase or the retention of a nonpolar compound during elution with several mobile phases of different compositions. The slope of the corresponding linear correlations can be used to characterize the hydrophobicity of the columns (stationary phases) under study. To analyze the polar interactions between the sorbate and the stationary phase it is advantageous to study the retention of a polar substance in several (at least in two) mobile phases of different compositions. The degree of displacement of the linear correlation relative to that for nonpolar substances can be considered a measure of the influence of residual silanol groups on the total retention characteristics.  相似文献   

13.
A new HPLC stationary phase based on n-butylimidazolium bromide has been characterized by a linear solvation energy relationship (LSER) approach in the binary acetonitrile/water mobile phases. The retention properties of the stationary phase were systematically evaluated in terms of intermolecular interactions between 28 test solutes and the stationary phase. The results and further comparisons with conventional reversed phase system confirm that retention properties are similar to phenyl phases in acetonitrile/water mixtures. The results obtained with acetonitrile/water mixtures are also compared with results obtained using methanol/water mixtures.  相似文献   

14.
The amount of water adsorbed on polar columns plays important role in hydrophilic interaction liquid chromatography. It may strongly differ for the individual types of polar columns used in this separation mode. We measured adsorption isotherms of water on an amide and three diol‐bonded stationary phases that differ in the chemistry of the bonded ligands and properties of the silica gel support. We studied the effects of the adsorbed water on the retention of aromatic carboxylic acids, flavonoids, benzoic acid derivatives, nucleic bases, and nucleosides in aqueous‐acetonitrile mobile phases over the full composition range. The graphs of the retention factors versus the volume fraction of water in mobile phase show “U‐profile” characteristic of a dual hydrophilic interaction–reversed phase retention mechanism. The minimum on the graph that marks the changing retention mechanism depends on the amount of adsorbed water. The linear solvation energy relationship model suggests that the retention in the hydrophilic interaction liquid chromatography mode is controlled mainly by proton–donor interactions in the stationary phase, depending on the column type. Finally, the accuracy of hydrophilic interaction liquid chromatography gradient prediction improves for columns that show a high water adsorption.  相似文献   

15.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an octylsiloxane-bonded (Kinetex C8) and diisobutyloctadecylsiloxane-bonded (Kinetex XB-C18) superficially porous silica stationary phases for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation-exchange) are important for the retention of weak bases with acetonitrile–water but not for methanol–water mobile phases. Compared with an octadecylsiloxane-bonded silica stationary phase (Kinetex C18) retention is reduced due to a less favorable phase ratio for both the octylsiloxane-bonded and diisobutyloctadecylsiloxane-bonded silica stationary phases while selectivity differences are small and solvent dependent. Selectivity differences for neutral compounds are larger for methanol–water but significantly suppressed for acetonitrile–water mobile phases. The selectivity differences arise from small changes in all system constants with solute size and hydrogen-bond basicity being the most important due to their dominant contribution to the retention mechanism. Exchanging the octadecylsiloxane-bonded silica column for either the octylsiloxane-bonded or diisobutyloctadecylsiloxane-bonded silica column affords little scope for extending the selectivity space and is restricted to fine tuning of separations, and in some cases, to obtain faster separations due to a more favorable phase ratio. For weak bases larger differences in relative retention are expected with acetonitrile–water mobile phases on account of the additional cation exchange interactions possible that are absent for the octadecylsiloxane-bonded silica stationary phase.  相似文献   

16.
The effect of varying mobile phase composition across a ternary space between two binary compositions is examined, on four different reversed-phase stationary phases. Examined stationary phases included endcapped C8 and C18, as well as a phenyl phase and a C18 phase with an embedded polar group (EPG). Mobile phases consisting of 50% water and various fractions of methanol and acetonitrile were evaluated. Retention thermodynamics are assessed via use of the van’t Hoff relationship, and retention mechanism is characterized via LSER analysis, as mobile phase composition was varied from 50/50/0 water/methanol/acetonitrile to 50/0/50 water/methanol acetonitrile. As expected, as the fraction of acetonitrile increases in the mobile phase, retention decreases. In most cases, the driving force for this decrease in retention is a reduction of the enthalpic contribution to retention. The entropic contribution to retention actually increases with acetonitrile content, but not enough to overcome the reduction in the enthalpic contribution. In a similar fashion, as methanol is replaced with acetonitrile, the v, e, and a LSER system constants change to favor elution, while the s and c constants change to favor retention. The b system constant did not show a monotonic change with mobile phase composition. Overall changes in retention across the mobile phase composition range varied, based on the identity of the stationary phase and the composition of the mobile phase.  相似文献   

17.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

18.
Lü H  Wang J  Wang X  Wu X  Lin X  Xie Z 《Journal of separation science》2007,30(17):2993-2999
A monolithic stationary phase was prepared in a single step by in situ copolymerization of iso-butyl methacrylate (IBMA), ethylene dimethacrylate (EDMA), and N,N-dimethylallylamine (DMAA) in a binary porogenic solvent consisting of N,N-dimethylformamide (DMF) and 1,4-butanediol. As the frame structures of monoliths, the amino groups are linked to support the EOF necessary for driving the mobile phase through the monolithic capillary, while the hydrophobic groups are introduced to provide the nonpolar sites for the chromatographic retention. To evaluate the column performance, separations of typical kinds of neutral or charged homologs, such as alkylbenzenes, phenols (including isomeric compounds of hydroquinone, resorcin, and catechol), and anilines (including isomeric compounds of o-phenylenediamine and 1,4-phenylenediamine), were performed, respectively on the prepared column under the mode of pressurized pCEC. Effects of the buffer pH and the mobile phase composition on the linear velocity of mobile phase and the retention factors of these compounds were investigated. It was found that the retention mechanism of charged solutes could be attributed to a mixed mode of hydrophobic interaction and electrophoresis, while an RP chromatographic behavior on the monolithic stationary phases was exhibited for neutral solutes. Especially, basic compounds such as anilines were well separated on the monolithic columns in the "counterdirectional mode," which effectively eliminated the electrostatic adsorption of basic analytes on the charged surface of the stationary phases.  相似文献   

19.
We propose a reversed phase HPLC (RP-HPLC) with an alkaline-resistant silica-based stationary phase, XBridge Shield RP(18), for the determination of the lipophilicity of drugs with diverse chemical nature ranging from acidic to basic. A set of 40 model compounds with well-defined solvatochromic parameters was selected to allow a broad distribution of structural properties. The chromatographic results showed that the lipophilicity index log k(w) obtained with XBridge Shield RP(18) was well correlated with experimental log P(oct) values (r(2)=0.96). Linear solvation free-energy relationship (LSER) analyses revealed that the retention mechanism of the stationary phase and 1-octanol/water partitioning were controlled by almost the same balance of intermolecular forces (hydrophobicity as expressed by the van der Waals volume V(w), H-bond acceptor basicity beta, and dipolarity/polarizability pi*). The results showed that XBridge Shield RP(18) phase overcomes the shortcomings of the silica-based stationary phases, the application of which to lipophilicity measurements had been limited to neutral and acidic compounds.  相似文献   

20.
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an ethyl-bridged, ocatadecylsiloxane-bonded superficially porous silica stationary phase (Kinetex EVO C18) for aqueous mobile phases containing 10–70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation-exchange) are important for the retention of weak bases with acetonitrile–water but not methanol–water mobile phase compositions. Compared with a superficially porous octadecylsiloxane-bonded silica stationary phase (Kinetex C18) with a similar morphology but different topology statistically significant differences in selectivity at the 95% confidence level are observed for neutral compounds that vary by size and hydrogen-bond basicity with other intermolecular interactions roughly similar. These selectivity differences are dampened with acetonitrile–water mobile phases, but are significant for methanol–water mobile phase compositions containing <30% (v/v) methanol. A comparison of a totally porous ethyl-bridged, octadecylsiloxane-bonded silica stationary phase (XBridge C18) with Kinetex EVO C18 indicated that they are effectively selectivity equivalent.  相似文献   