共查询到20条相似文献,搜索用时 15 毫秒
1.
电化学法修饰玻璃碳电极及其铜的阳极溶出伏安法测定 总被引:3,自引:0,他引:3
在邻苯二酚-甲醛-NaOH介质中,于-0.1 ̄+1.5V(vs,SCE)扫描范围内用循环伏安法制作修饰玻璃碳电极。电极可用于水中痕量铜的测定,其灵敏度比未修饰的玻璃碳电极提高35倍以上,定量下限为0.1ng/ml。 相似文献
2.
《Analytical letters》2012,45(7):1411-1420
Abstract Cadmium in the presence of 0.04 M NaCl as the electrolyte was determined using stripping voltammetry with superimposed constant amplitude pulses of negative polarity (SVPNP) or positive polarity (SVPPP), and differential pulses stripping voltammetry using rotating disc glass carbon electrode (RDGCE). The SVPNP was found to give the greatest sensitivity. The anodic peak was obtained at potential ?850 to ?795 mV due to the oxidation of cadmium to cadmium(II). Linear calibration curves were obtained in the concentration range between 1.5×10?9–2×10?10 M. The relative standard deviation is 4.25% at very low concentration of 2×10?10 M. This method was successfully applied to the determination of cadmium in some foodstuffs (wheat and its products, vegetables) after acid digestion. 相似文献
3.
4.
《Analytical letters》2012,45(1-2):89-98
Abstract An A.S.V. method for determination of mercury in ultrapure gallium has been developed. The procedure is very simple and allows a sensitivity high enough to verify the highest purity level of Ga as concerns Hg traces (i.e. 1×10?5 % Hg in Ga by weight). The above method was applied to some samples of gallium used in this laboratory. 相似文献
5.
6.
双嘧达莫在玻碳电极上的阳极伏安法研究 总被引:7,自引:0,他引:7
用直流伏安法(DCV),微分脉冲伏安法(DPV)和循环伏安法(CV)在玻碳电极(GCE)上研究了双嘧达莫(DPM)在不同介质中的阳极伏安行为,发现在0.01mol/LCHl溶液中于0.62V(vs.Ag/AgCl)右左生产一个阳极氧化峰,其峰高与浓度的线性方程分别为r=0.0004 0.17C(0.05~1.0mg/L)和y=0.052 0.22C(0.5~10mg/L). 在此体中大多数金属离子和20多种有机生代物质不干扰测定,采用该方法可不经分离,直接测定药物制剂和尿样吕DPM的含量,同时对DPM的电极反反应机理进行了探讨. 相似文献
7.
Ge Zhao Kuaizhi Liu Song Lin Ji Liang Xinyong Guo Zhijun Zhang 《Mikrochimica acta》2003,143(4):255-260
Carbon nanotubes were modified on the surface of a glassy carbon electrode (GC) and initially applied in semi-derivative anode stripping voltammetry for the determination of 6-benzylaminopurine. The experiments demonstrated that the presence of the carbon nanotube greatly increased the current of the oxidation peak of benzylaminopurine. Cyclic voltammetry (CV) and semi-derivative voltammetry were used in a comparative investigation into the electrochemical oxidation of benzylaminopurine with the modified electrode. Studies on the effect of pH on the peak current and potential were carried out over the pH range of 9.013.0 with the NH3–NH4Cl buffer solution. A pH of 10.0 was chosen as the optimum pH. Other experimental parameters, such as film thickness, accumulation potential, temperature etc. were optimized. The anodic peak current was found to be linearly related to the concentration of benzylaminopurine over the range of 4.0×10–8 to 1.0×10–5mol·L–1 with a detection limit of 5.0×10–9mol·L–1 in an accumulation time of 5min. Interferences of some inorganic and organic species on the response have been studied. 相似文献
8.
9.
阴极溶出伏安法测定异烟肼的研究 总被引:1,自引:0,他引:1
报道了吸附阴极溶出伏安法测定异烟肼。探讨了电极反应机理。在0.01mgol/L硼砂底液中,峰电位为-1.40V。峰电流与异烟肼浓度在4.0*10^-7-1.5*10^-5mol/L范围内呈良好的线性关系,相关系为0.9913。该方法用于异烟肼片剂的测定,获得满意结果。 相似文献
10.
11.
Arben Merkoçi Majlinda Vasjari Esteve Fàbregas Salvador Alegret 《Mikrochimica acta》2000,135(1-2):29-33
Two different approaches for the modification of glassy carbon electrodes using a mercury film and mercury-nafion are compared.
The mixture of mercury(II) chloride solution with a nafion solution diluted in ethanol is used to coat the polished glassy
carbon surface. The modified working electrodes are compared when measuring Pb and Cu in real seawater samples. An optimisation
of the parameters during the formation of the films was done to obtain well-defined stripping peaks. The type of inert supporting
electrolyte and the pH play an important role on the sensitivity of the measurement. Results for Pb and Cu determinations
show the advantages of Hg-nafion modification as an alternative method. These advantages include a shorter modification time,
the avoidance of Hg solutions during the formation of the Hg film and an improved sensitivity for Pb determination.
Received March 16, 1999. Revision April 24, 2000. 相似文献
12.
Ornella Abollino Agnese Giacomino Mery Malandrino Giuseppina Piscionieri Edoardo Mentasti 《Electroanalysis》2008,20(1):75-83
The aim of this work is the development of a procedure for the determination of aqueous Hg(II) by anodic stripping voltammetry at a gold nanoparticle‐modified glassy carbon electrode (AuNPs‐GCE). The signal of aqueous Hg(II) was measured in the square wave mode; the effect of potential scan parameters, deposition potential and deposition time on the analytical signal was examined. The supporting electrolyte was 0.06 M HCl. The repeatability, the linearity, the accuracy, the detection limit of the procedure and the interferences of other cations and of anions were evaluated. The performance of the AuNPs‐GCE was compared with those of a solid (SGE) and a film (FGE) gold electrode: the AuNPs‐GCE showed to provide lower detection limits and higher repeatability. The renewable surface permits to eliminate memory effects, to maintain a stable baseline and response, and to avoid frequent mechanical cleaning steps. The applicability of the AuNPs‐GCE for Hg(II) determination in drinking waters, sediments and pharmaceuticals was demonstrated. 相似文献
13.
《Electroanalysis》2005,17(8):685-693
Carbon paste electrodes were modified by mixing appropriate amounts of the monomers o‐phenylendiamine, p‐phenylendiamine and m‐phenylendiamine (o‐PD, p‐PD and m‐PD) into a graphite powder‐paraffin oil matrix. The electropolymerization of the incorporated phenylendiamine was then carried out in a carbon paste electrode in acidic medium by cyclic voltammetry between ?0.30 V and +0.90 or under constant potential. The modified carbon paste electrodes (MCPEs) obtained by this electropolymerization method were found to be useful for trace determination of Pb2+ in aqueous solutions. Lead(II) was first preconcentrated on the modified electrodes by complexation with the modifier, and the electrode was then transferred to an electrochemical cell. The best results in terms of sensitivity and detection limit were obtained with poly p‐phenylenediamine (poly (p‐PD)). For a 10‐min preconcentration time, the calibration plot was linear from 5×10?8 mol L?1 to 10?5 mol L?1, with r2=0.999 and relative standard deviation equal to 5%. However, the lowest lead concentration that could be detected was 10?9 mol L?1. Interference from metal ions like Cd(II), Hg(II), Zn(II), Fe(II) and Cu(II) was also studied. 相似文献
14.
金-钯双金属纳米颗粒修饰玻碳电极阳极溶出伏安法测定三价砷的方法研究 总被引:1,自引:0,他引:1
研究了金-钯双金属纳米颗粒修饰电极测定痕量砷的阳极溶出伏安法。采用紫外可见分光光度法、高分辨透射电镜及循环伏安法对颗粒的结构和电化学特性进行表征。采用方波伏安法测定三价砷,探讨了富集电位和方波伏安参数如频率、增幅、波幅以及干扰离子等对测定结果的影响。实验结果表明:金-钯双金属纳米颗粒呈壳-核结构;砷在0.30 V出现灵敏的阳极溶出伏安峰,峰电流与砷质量浓度在0.5~20μg/L范围内呈良好的线性关系,检出限为0.15μg/L;所制备的修饰电极重现性好,可用于三价砷的重复测定。共存离子Cu(Ⅱ)会影响三价砷的测定,而Pb(Ⅱ)、Cd(Ⅱ)、Zn(Ⅱ)等离子的存在对测定结果无影响。 相似文献
15.
Andrzej Bobrowski Mariola Maczuga Agnieszka Królicka Evangelia Konstanteli Chrysavgi Sakellaropoulou Anastasios Economou 《Analytical letters》2017,50(18):2920-2936
The voltammetric performance of an in situ plated antimony film screen-printed carbon electrode in hydrochloric acid, acetate buffer, and tartrate buffer was evaluated for the detection of copper(II) with differential pulse anodic stripping voltammetry. The tartrate buffer was superior, providing high sensitivity and good separation of copper and antimony stripping peaks. The analytical conditions for the determination of copper(II) were optimized. The detection limit was estimated to be 0.14?µg?L?1 copper(II) and the relative standard deviation for 2.5?µg?L?1 copper(II) was 3%. The applicability of the method was illustrated by the analysis of soil conditioner samples. 相似文献
16.
This work proposes a vibrating microwire electrode as working electrode in stripping voltammetry. The vibration was found to maintain a constant and thin (1–2 μm) diffusion layer during the deposition step. The electrode vibration eliminated the need for external stirring of the solution, thus facilitating in situ detection in the environment. The vibration was effected by fixing a low‐voltage (3 V), asymmetric, electrical rotor to the working electrode (a gold microwire of either 5 or 25 μm). The sensitivity of the vibrated electrode was ca. 22×greater than stationary. Measurements of copper (4 nM) by anodic stripping voltammetry using the vibrating electrode had a low standard deviation (1% for n=6) indicating that the diffusion layer had only minor variability. The agitation mechanism was unaffected by water moving at >2 m s?1 and by water pressure equivalent to a depth of >40 m, indicating its suitability for in situ measurements. The vibrating probe was used for in situ detection of copper by anodic stripping voltammetry to a depth of 6 m. Using a 5 min deposition time, the limit of detection for labile copper was 38 pM. 相似文献
17.
Omar El Tall Nicole Jaffrezic‐Renault Monique Sigaud Olivier Vittori 《Electroanalysis》2007,19(11):1152-1159
Boron‐doped Diamond (BDD) electrode has become one of the important tools for heavy metal detection. By studying some analytical parameters of DPASV method, like deposition time and potential in different electrolyte concentrations (acetate buffer), the conditions for detecting very low metal ion levels (Zn, Cd, Pb, and Cu) could be chosen. Diluted electrolyte (0.01 M buffer) was one of the factors favoring low detection and quantification limits, but its quantification range is short in comparison to more concentrated media. For ?1.7 V deposition potential, the detection of single metal at ppb levels was reached in 60 s deposition time. Understanding different metal‐metal interactions shows the limits to the simultaneous determination of heavy metals at BDD. Quantification was possible for the simultaneous determination of Zn, Cd and Pb despite the overlapping of Zn and Cd peaks. The performance of the BDD was compared with that of another C‐based solid electrode: the glassy carbon electrode (without mercury plating). A lower base line current, wider potential range, higher sensitivity (3 to 5 times higher than GC) and longevity of the material were noticed for the BDD. 相似文献
18.
Adsorption stripping voltammetry, a very sensitive electroanalytical method, was employed to determine reserpine, a kind of anti-hypertensive drug. In 0.1M phosphate buffer with a pH of 6.0, reserpine was accumulated at a multi-wall carbon nanotubes (MWNT)-modified glassy carbon electrode (GCE) surface under the condition of open-circuit. In the following anodic sweep from 0.20 to 1.00V, reserpine, adsorbed at the MWNT-modified GCE surface, was oxidized and yielded a sensitive oxidation peak at 0.64V. Due to its unique structure and extraordinary properties, MWNT shows a ten times higher accumulation efficiency toward reserpine, compared with a bare GCE. Hence, the amount of reserpine at the MWNT-modified GCE surface increases significantly, and finally the oxidation peak current improves greatly. The experimental conditions, such as supporting electrolyte, pH value, the amount of MWNT-DHP suspension, accumulation time and scan rate, were optimized for the measurement of reserpine, and a sensitive electroanalytical method was proposed for reserpine determination. The oxidation peak current varies linearly with the concentration of reserpine over the range of 2×10–8 to 1×10–5M, and the detection limit is 7.5×10–9M after 4min open-circuit accumulation. The relative standard deviation at 1×10–6M reserpine was about 4.7% (n=7), indicating excellent reproducibility. This new method was successfully demonstrated with reserpine injections and tablets. 相似文献
19.
Wei Yue Bill L. Riehl Nebojsa Pantelic Kevin T. Schlueter Jay M. Johnson Robert A. Wilson Xuefei Guo Edward E. King William R. Heineman 《Electroanalysis》2012,24(5):1039-1046
Anodic stripping voltammetry (ASV) determination of Pb2+, Cd2+, and Zn2+ was done using metal catalyst free carbon nanotube (MCFCN) electrodes. Osteryoung square wave stripping voltammetry (OSWSV) was selected for detection. The MCFCNTs are synthesized via Carbo Thermal Carbide Conversion method which leads to residual transition metal free in the CNT structure. The new material shows very good results in detecting heavy metal ions, such as Pb2+, Cd2+, and Zn2+. The calculated limits of detection were 13 nM, 32 nM and 50 nM for Pb2+, Cd2+ and Zn2+, respectively with a deposition time of 150 s. 相似文献
20.
Suw Young Ly Young Sam Jung Myung Hoon Kim In kwon Han Woon Won Jung Hyun Sook Kim 《Mikrochimica acta》2004,146(3-4):207-213
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1. 相似文献