首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 14 毫秒
1.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
The purified extract of propolis is used as a traditional remedy for the treatment of several diseases. Its beneficial activities are mainly attributed to the polyphenolic fraction. Nevertheless, propolis can cause allergic dermatitis and the sensitization rate in humans is increasing significantly mainly in younger subjects. The aim of this study was to develop and validate a selective and sensitive ultra‐performance liquid chromatography tandem mass spectrometry analysis (UPLC/MS/MS) for the evaluation of the amount of caffeic acid and its esters with allergenic action in raw propolis samples and commercial formulations. The separation was carried out on a 1.7 μm C18 BEH Shield column and the detection performed by means of electrospray ionization in negative ion mode with multiple reaction monitoring. The confirmation of formulae of the precursor and product ions was accomplished by injection into a high‐resolution system (FTICR‐MS) using accurate mass measurements. The error was below 1.4 ppm.The range of the standard curves was 0.5–10 μg/mL and dihydrocaffeic acid was used as internal standard (IS). The lower limit of detection (LLOD) for 3‐methyl‐2‐butenyl‐ (3M2B), 3‐methyl‐3‐butenyl‐ (3M3B), 2‐methyl‐2‐butenyl‐ (2M2B), benzyl‐ (CABE), phenylethylcaffeic acid (CAPE) and for caffeic acid (CA) and the IS was 0.1 and 0.3 μg/mL, respectively. The recoveries were in the range 96–104% and the intra‐ and inter‐day precisions were within 6.2%. In the European (n = 8) and Asiatic (n = 3) propolis the most abundant allergens were CABE>3M2B>CAPE>3M3B>CA>2M2B. These compounds were not found in the red (n = 1) and green (n = 1) Brazilian propolis. Hydroalcoholic extracts (n = 6) and tablets (n = 6) were analyzed by the proposed UPLC/MS/MS method. The results showed that in the commercial products CABE, 3M2B, CAPE and 3M3B were also the most abundant. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and validated for the determination of troglitazone in mouse plasma. Troglitazone and its internal standard (IS), rosiglitazone, were separated on an ACQUITY UPLC BEH C(18) column (1.7 microm particle size, 50 x 2.1 mm i.d.) by gradient elution with water and methanol at a flow rate of 0.5 mL/min. The cycle time of each analysis was 2.5 min. Rosiglitazone and troglitazone eluted at 1.13 and 1.57 min, respectively, and were chromatographically resolved from the ion suppression and enhancement zones due to the biological matrix effect. Quantitation of the analytes was performed in electrospray negative ionization mode (ESI -ve) using multiple reaction monitoring (MRM) experiments. The weighted (1/x) calibration curve was quadratic over the plasma concentration range 1-2500 ng/mL with a correlation coefficient (r(2)) of 0.9966. The limit of quantitation (LOQ) of troglitazone in mouse plasma was lower than 1 ng/mL. The inter- and intra-day variations of the assay were lower than 12.1%; the overall accuracy ranged from 86.4-110.2% and recovery from spiked plasma was more than 60%. The developed method was successfully applied to determine troglitazone in mouse plasma after intraperitoneal administration.  相似文献   

4.
An ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOF-MS)-based metabolomic approach was developed to characterize the metabolic profile associated with isoproterenol (ISO)-induced myocardial infarction (MI). Analysis of the serum samples revealed distinct changes in the biochemical patterns of ISO-induced rats. A multivariate statistical method, supervised partial least squares-discriminant analysis (PLS-DA), was then used for screening of potential biomarkers. As a result, 13 lipid biomarkers, including lysophosphatidylcholines (Lyso-PCs) and fatty acids were identified by the accurate mass measurement of TOF-MS. The relationship between abnormal lipid metabolism and the formation of MI were also studied. This work demonstrates the utility of UPLC/TOF-MS-based metabolic profiling combined with multivariate analysis as a powerful tool to further investigate the pathogenesis of cardiovascular diseases.  相似文献   

5.
A rapid multiresidue method for the analysis of more than 40 herbicides (such as simazine, terbuthylazine and diuron) in waters has been developed and validated by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC/MS/MS). Prior to chromatographic determination, the samples were extracted using a solid-phase extraction procedure. The analysis was performed on an Acquity UPLC BEH C(18) column using a gradient elution profile and a mobile phase consisting of methanol and an aqueous solution of formic acid (0.01%). Other chromatographic and MS/MS parameters were optimised in order to improve selectivity and sensitivity of the analytes. The analytes were detected using electrospray ionisation (ESI)-MS/MS in positive ion mode with multiple reaction monitoring (MRM), optimising parameters such as voltage cone, capillary voltage, source and desolvation temperature, and desolvation and cone gas flow. The optimised method provides a rapid separation (less than 10 min) of the selected herbicides in the assayed matrices, and it was validated by the analysis of spiked blank matrix samples. Good linearity was obtained and the repeatability of the method was less than 20% for the lowest calibration point. The limits of detection ranged from 0.002 to 0.02 microg/L, and the limits of quantification from 0.005 to 0.05 microg/L, which were below the values specified by the European Union. Finally, the method was successfully applied to real environmental samples from Andalusia (southern Spain). Terbuthylazine, simazine, atrazine desisopropyl and desethyl terbuthylazine were the herbicides most frequently found in water samples.  相似文献   

6.
Ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS–MS) has been used for screening and quantification of 32 pesticides and metabolites in two fruit matrices. The compounds investigated belonged to different chemical families of insecticides, acaricides, fungicides, and herbicides; several metabolites were also included. Quantification was conducted using matrix-matched standards calibration; response was a linear function of concentration in the range tested (10–500 ng mL−1). The method was validated with blank samples of lemon and raisin spiked at 0.01 and 0.1 mg kg−1, and recoveries were satisfactory, between 70 and 110%, for most of the pesticides tested and relative standard deviations were below 15% (n = 5 at each spiking level). Excellent sensitivity resulted in limits of detection for all compounds well below 0.01 mg kg−1, with the limit of quantification being validated at 0.01 mg kg−1. The UPLC system generates narrow peaks (approx. 5 s), thus increasing peak height and improving sensitivity. This improved separation efficiency facilitates adequate resolution not only of the analytes but also of matrix interferences compared with conventional HPLC. The method developed could also resolve some geometric isomers. The main advantage of this approach is the high sample throughput achieved because of the short analysis time, which enables satisfactory separation of all the compounds in less than 5 min per sample.  相似文献   

7.
A new method for the analysis of three ecological insecticides, namely azadyrachtin, spinosad (sum of spinosyn A and spinosyn D) and rotenone, in produce and soil samples is presented. Investigated compounds are one of the most significant insecticides authorized for organic farming crop protection in many countries. Extraction of the pesticides from plant and soil matrices was performed by using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. The method entailed a single extraction of the investigated compounds with acidified acetonitrile followed by a dispersive solid-phase extraction cleanup step prior to the final determination by reverse-phase ultra-performance liquid chromatography/tandem quadrupole mass spectrometry (UPLC-MS/MS). Validation studies were carried out on cabbage, tomato and soil samples. Recoveries of the spiked samples were in the range between 67% and 108%, depending on the matrix and the spiking level. Relative standard deviations for all matrix–compound combinations did not exceed 12%. The limits of quantification were ≤0.01 mg kg−1 in all cases, except for azadirachtin. The developed method was applied to the analysis of real samples originating from organic farming production.  相似文献   

8.
High-throughput ADME screening for compound drug development properties has become an essential part of the modern drug discovery process, allowing more informed decisions to be made on the best compounds to take forward in the discovery/development process. This however is a time-consuming process requiring multiple tests to be performed, demanding a significant amount of liquid chromatography/mass spectrometry (LC/MS) instrument time. This article focuses on the use of sub-2 microm porous particle LC coupled to tandem quadrupole MS/MS mass spectrometry for the rapid screening of ADME properties. Using this approach analysis times from 30 s to 1 min were achievable allowing analysis times to be cut by 80%. The use of the small particles coupled to high flow rates allowed for sufficient resolution, even with very short analysis time, to resolve the analytes of interest from similar compounds that would interfere with the assay. The use of dedicated, intelligent, software packages allowed for the user-free generation of MS/MS conditions and the processing of the data.  相似文献   

9.
Gastric cancer screening or diagnosis is mainly based on endoscopy and biopsy. The aim of this study was to identify the difference of metabolomic profile between normal and malignant gastric tissue, and to further explore tumor biomarkers. Chemical derivatization together with gas chromatography/mass spectrometry (GC/MS) was utilized to obtain the metabolomic information of the malignant and non-malignant tissues of gastric mucosae in 18 gastric cancer patients. Acquired metabolomic data was analyzed using the Wilcoxon rank sum test to find the tissue metabolic biomarkers for gastric cancer. A diagnostic model for gastric cancer was constructed using principal component analysis (PCA), and was assessed with receiver-operating characteristic (ROC) curves. Results showed that 18 metabolites were detected differently between the malignant tissues and the adjacent non-malignant tissues of gastric mucosa. Five metabolites were also detected differently between the non-invasive tumors and the invasive tumors. The diagnostic model could discriminate tumors from normal mucosae with an area under the curve (AUC) value of 0.9629, and another diagnostic model constructed for clinical staging was assessed with an AUC value of 0.969. We conclude that the metabolomic profile of malignant gastric tissue was different from normal, and that the selected tissue metabolites could probably be applied for clinical diagnosis or staging for gastric cancer.  相似文献   

10.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

11.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

12.
This paper describes the application of ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) technology to separate and identify amphetamine-type substances (amphetamine, methamphetamine), common and novel designer analogues (MDA, MDMA, PMA, 4-MTA, MBDB), and ketamine using Acquity UPLC/Micromass Quattro Micro API mass spectrometer instrumentation (Waters Corporation, USA). From injection of drug reference standards, it was demonstrated that these compounds can be identified by product ion mass spectra in less than 4 min total analysis time, indicating that the technological advancements associated with UPLC/MS/MS allow it to serve as a powerful analytical tool for high-throughput testing. In addition to demonstrating the separation and response of these drug compounds under the stated UPLC/MS/MS conditions, we believe the acquired product ion spectra will be a beneficial reference to laboratories interested in incorporating the use of this technology in the routine analysis of drugs of abuse.  相似文献   

13.
14.
Geniposide, an iridoid glycoside, is an important and characteristic compound in the fruits of Gardenia jasminoides Ellis, a commonly used medicinal herb in Chinese traditional and folk medicine for the treatment of inflammation and jaundice. However, few studies have been carried out on the metabolism of geniposide. In this study, we have established a rapid and sensitive method using ultra‐performance liquid chromatography coupled with electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (UPLC/ESI‐QTOF‐MS) for analysis of the metabolic profile of geniposide in rat urine after oral administration. A total of ten metabolites were detected and identified by comparing their fragmentation patterns with that of geniposide using Metabolynx? and MassFragment? software tools. The results revealed that the principal metabolism pathways of geniposide in rat occurred after deglycosylation of the irdoid glycoside take place and this is followed by glucuronidation and the pyran‐ring cleavages. The major metabolite, the glucuronic acid conjugate of genipin as observed in vivo, was further confirmed by the in vitro enzymatic study. The results of this work have demonstrated the feasibility of the UPLC/ESI‐QTOF‐MS approach for rapid and reliable characterization of metabolites from iridoid compounds. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Two liquid chromatography mass spectrometric techniques, i.e. ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/Q-Tof MS) and high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS), were used for quantification, confirmation or identification of six macrolide antibiotic residues and/or their degradation products in eggs, raw milk, and/or honey. Macrolides were extracted from food samples by acetonitrile or phosphate buffer (0.1 M, pH 8.0), and sample extracts were further cleaned up using solid-phase extraction cartridges. UPLC/Q-Tof data were acquired in Tof MS full scan mode that allowed both quantification and confirmation of macrolides, and identification of their degradation products. LC/MS/MS data acquisition was achieved using multiple reaction monitoring (MRM), i.e. two transitions, to provide a high degree of sensitivity and repeatability. Matrix-matched standard calibration curves with the use of roxithromycin as an internal standard were utilized to achieve the best accuracy of the method. Both techniques demonstrated good quantitative performance in terms of accuracy and repeatability. LC/MS/MS had advantages over UPLC/Q-Tof MS in that its limits of detection were lower and repeatability was somewhat better. UPLC/Q-Tof provided ultimate and unequivocal confirmation of positive findings, and allowed degradation product identification based on accurate mass. The combination of the two techniques can be very beneficial or complementary in routine analysis of macrolide antibiotic residues and their degradation products in food matrices to ensure the safety of food supply.  相似文献   

16.
Glutathione S-transferases (GSTs) isolated from maize were used to catalyze the conjugation of glutathione (GSH) with chloroacetanilide herbicides, producing stable conjugates that were structurally characterized using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF-MS) and liquid chromatography/ion trap mass spectrometry (LC/IT-MS). Enzyme-mediated dechlorination of alachlor, metolachlor, and propachlor resulted during GSH conjugation as revealed by the mass spectra of the conjugates, which was confirmed by the loss of the chlorine isotopic signature and from high accurate mass measurements. Several fragmentation patterns in the mass spectra of the chloroacetanilide-GSH conjugates can be used to verify the identities of the enzyme reaction products, such as characteristic ions corresponding to the neutral loss of glutamic acid residue (129 Da) and water (18 Da) observed in the product ion spectrum. For the first time, data are presented showing detection of chloroacetanilides that are conjugated with two GSH molecules, in addition to the known single GSH conjugates.  相似文献   

17.
Ultra-performance liquid chromatography (UPLC) was investigated as an alternative to high-performance liquid chromatography (HPLC) for analyzing pharmaceutical drug candidates. We previously developed a 96-well-based high-speed solubility assay system (HSSOL) using HPLC/UV and a LogD assay system (HSLogD) using HPLC/MS [Y. Dohta, T. Yamashita, S. Horiike, T. Nakamura, T. Fukami, Anal. Chem. 79 (2007) 8312]. We have introduced the UPLC/MS system into this previously developed HSSOL system to increase throughput. Results obtained by the UPLC/MS and HPLC/UV systems showed good agreement, validating the usefulness of the UPLC/MS system. A high-speed solubility assay system was developed employing the UPLC/MS system, thereby tripling the throughput.  相似文献   

18.
A rapid, highly sensitive and selective method was developed for the determination of the cyantraniliprole and its major metabolite J9Z38 in cucumber, tomato and soil by ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS). Target compounds were extracted with acetonitrile and an aliquot cleaned with primary and secondary amine. Two pairs of precursor product ion transitions for cyantraniliprole and J9Z38 were measured and evaluated. Average recoveries for cucumber, tomato and soil at three levels (10, 50 and 100 µg/kg) ranged from 74.7 to 96.2% with intra‐day relative standard deviation (RSD) of 2.6–15.1% and inter‐day RSD of 3.4–13.3%. The limit of quantitation for cyantraniliprole and J9Z38 were determined to be 5 and 10 µg/kg in samples (cucumber, tomato and soil), respectively. This method was used to determine the cyantraniliprole and J9Z38 residues in real cucumber, tomato and soil samples for studies on their dissipation. The trial results showed that the half‐lives of cyantraniliprole obtained after treatments were 2.2, 2.8 and 9.5 days in cucumber, tomato and soil in Zhejiang, respectively, and that the average levels of cyantraniliprole and J9Z38 residues in cucumber and tomato were all <0.01 mg/kg with the interval of 10 days after treatment. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A simple, rapid, sensitive and specific method used to screen and confirm multi-class diuretics residues in whole bovine milk is described. Thirteen drugs of four different classes including carbonic anhydrase inhibitors, loop, thiazide and potassium-sparing diuretics were extracted from whole milk by acetonitrile followed by further purification with hexane. The analytes were separated using an ACQUITY UPLC BEH C18 column and detected by electrospray ionization tandem mass spectrometry (ESI-MS/MS). MS data acquisition was performed by a time-scheduled multiple reaction monitoring program, selecting two ion transitions for each target compound. The overall average recoveries based on matrix-fortified curves fortified with diuretics at three levels ranged from 80.6 to 108.8% with the coefficients of variation ranging from 2.6 to 19.7% (n = 6). The limits of quantitation (LOQs) of diuretics in bovine milk were 5.0 microg/kg for spironolactone and 0.5 microg/kg for other analytes, respectively.  相似文献   

20.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号