首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The simultaneous analysis of aflatoxins B1, G1, B2, G2 and ochratoxin A in beer was carried out by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). Mycotoxins were extracted, purified and concentrated from the beer sample in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric sorbent. Optimization of different parameters, such as type of SPE sorbent, type and amount of wash solvent and pH of the sample, was carried out. The mobile phase consisted of a gradient of methanol + water (0.1% HCOOH) and a reversed-phase C18 column was used for the separation. The mass spectrometer used an electrospray ionization source operated in the positive mode to detect aflatoxins and in the negative mode to detect ochratoxin. UPLC/MS/MS is a rapid and sensitive technique that allows the separation of the five toxins in only 3.2 min. The limit of detection is 1 pg.  相似文献   

2.
Since the discovery of aflatoxins (AFs) in the 1960s, much research has focused on detecting the toxins in contaminated food and feedstuffs. But the quality determination in medicinal plant matrices with respect to AFs is scare. Hence, a simple, accurate and sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method was developed for simultaneous determination of AFs AFB1, AFB2, AFG1 and AFG2 in two Indian popular medicinal herbs i.e. senna (Cassia angustifolia) and kalmegh (Andrographis paniculata). AFs have been extracted from herb matrix using a QuEChERS (quick, easy, cheap, effective, rugged and safe)-based extraction procedure followed by applying primary secondary amine and C18 for further clean-up step and then were quantified under the multiple reaction monitoring together with positive ionisation modes. Matrix-matched calibration was used for quantification in order to reduce the matrix effect. Validation of the method was carried out in herbs by recovery experiments. Recoveries of the spiked samples were in the range of 61.9–111.5% with an inter-day and intraday relative standard deviation lower than 20.0%. Limits of detection and quantification ranged from 0.41 to 0.95 ng mL?1 and 1.2 to 3.8 μg kg?1, respectively. The expanded uncertainty of the method was <21% for all the toxins in both the herbs. Finally, the proposed method was successfully applied to determine AF residues in real field samples of senna and kalmegh obtained from different locations in India.  相似文献   

3.
A liquid chromatography/tandem mass spectrometry method was developed for the simultaneous determination of aflatoxins (B(1), B(2), G(1), G(2)), ochratoxin A, fumonisins (B(1), B(2)), deoxynivalenol, zearalenone, T-2 and HT-2 toxins in maize. A double extraction approach, using a phosphate-buffered solution followed by methanol, was applied to achieve effective co-extraction of the 11 mycotoxins under investigation having quite different polarities and chemical structures. A new multitoxin immunoaffinity column containing antibodies for all these mycotoxins was used to clean up the extract. Detection and quantification of the 11 mycotoxins were performed by reversed-phase liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS) using, as chromatographic mobile phase, a linear gradient of methanol/water containing 0.5% acetic acid and 1 mM ammonium acetate. Method performances were quite satisfactory for all tested mycotoxins at contamination levels close to or below the relevant EU maximum permitted or recommended levels. Limits of detection in maize ranged from 0.3 to 4.2 microg/kg. Recoveries higher than 79% were obtained for all tested mycotoxins with relative standard deviations less than 13%.  相似文献   

4.
A new approach to the determination of afiatoxins B1, B2, G1 and G2 is given; the method involves high-performance liquid chromatography with amperometric detection in the differential-pulse mode at the dropping mercury electrode with 1-s drop time. These aflatoxins can be determined simultaneously with good resolution but with some compromise in sensitivity. The detection limit of underivatized aflatoxin standards is around 5 ng. Average recoveries of aflatoxins from peanut butter by the Beebe method were G2 81%, G1 87%, B2 77% and B1 76%.  相似文献   

5.
6.
An easy method for the determination of aflatoxins B1, G1, B2 and G2 in Rhammus purshiana by LC coupled to mass spectrometry has been developed. Aflatoxins were extracted with a mixture of methanol and water and then it was purified by solid-phase clean-up using a polymeric sorbent, not described previously, for the determination of these toxins. The eluted extract was injected into the chromatographic system using a reversed-phase C18 short column with an isocratic mobile phase composed of methanol-water (30:70). A single-quadruple mass spectrometry using an electrospray ionization source operating in the positive ion mode was used to detect aflatoxins due to derivatization presenting several disadvantages. Recoveries of the full analytical procedure were 110% for aflatoxin B1, 89% for aflatoxin B2, 81% for aflatoxin G1 and 77% for aflatoxin G2. Detection limit (S/N = 3) was 10 ng and quantification limit (S/N = 10) was 25 ng, calculated as amount in medicinal herb.  相似文献   

7.
A sensitive and accurate method employing a single stage high resolution mass spectrometer equipped with a high-energy collision-dissociation cell (HCD) for the simultaneous determination of deoxynivalenol (DON), T-2 toxin (T-2) and HT-2 toxin (HT-2) in a processed bread model food has been developed. Two sample pre-treatment routes for the extraction of these mycotoxins were investigated, based on Mycosep® column clean up or QuEChERS-like procedure, respectively. The former approach suffered less from matrix effects and allowed to achieve in bread samples LODs of 7, 12 and 17 ng/g for T-2, HT-2 and DON, respectively, with 0.5 ppm mass accuracy. Two acquisition modes, full scan MS and all ion fragmentation, exploiting the fragmentation features offered by an HCD chamber and integrated within the Orbitrap analyser, were compared for quantitative purposes. The method was applied to investigate the degradation of these mycotoxins during bread processing using a bread model food. Most T-2 hydrolyzed to HT-2 during dough preparation, and about 20–30% of HT-2 and DON was degraded during bread baking.  相似文献   

8.
超高效液相色谱法快速测定发酵茶叶中的黄曲霉毒素   总被引:6,自引:0,他引:6  
建立了用超高效液相色谱/紫外检测器测定发酵茶叶中黄曲霉毒素B1、B2、G1和G2的方法.用CH2Q2提取黄曲霉毒素,提取液经浓缩后,用LC-CN固相萃取小柱净化,超高效液相色谱测定.在浓度范围20~200μg/L(B1、G1),15~120μg/L(B2、G2)内具有良好的线性相关关系.黄曲霉毒素的回收率为81.4%~92.3%,相对标准偏差RSD 1.6%~4.2%.检出限为0.32μg/kg(B1、G1),0.18μg/kg(B2、G2)(S/N=3).  相似文献   

9.
The analysis of pesticides in water samples is a problem of primary concern for quality control laboratories due to the toxicity level of these compounds and their public health risk. In order to evaluate the impact of pesticides in the Lisbon drinking water supply system, following the requirements of the European Union Directive 98/83/EC, we developed and validated an analytical method based on the combination of solid-phase extraction with liquid chromatography and tandem mass spectrometry. In this work, several pesticides were studied: imidacloprid, dimethoate, cymoxanil, carbendazime, phosmet, carbofuran, isoproturon, diuron, methidathion, linuron, pyrimethanil, methiocarbe, tebuconazole and chlorpyrifos. Several parameters of the electrospray source were optimized in order to get the best formation conditions of the precursor ion for each pesticide, namely capillary and extractor voltage, cone voltage, cone gas flow rate and desolvation gas flow rate. After optimization of the collision cell energy of the triple quadrupole, two different precursor ion-product ion transitions were selected for each pesticide, one for quantification and one for qualification, and these ions were monitored under time-scheduled multiple reaction monitoring (MRM) conditions. The selection of specific fragment ions for each pesticide guarantees a high degree of selectivity as well as additional sensitivity to quantify trace levels of these pesticides in water samples. This method showed excellent linearity ranges for all pesticides, with correlation coefficients greater than 0.9989. Determination limits (between 0.0041 and 0.0480 microg/L), precision (RSD <9.18%), accuracy and recovery studies in several water samples using solid-phase extraction were also performed.  相似文献   

10.
沉积物中皮质类固醇激素(CSs)的痕量分析对探究其在环境多介质中的赋存状况和环境行为具有重要意义.然而目前相关研究主要集中在水样中糖皮质激素的测定,对基质更为复杂的环境固体样品中CSs的定量分析研究仍十分有限亦缺乏针对性、系统性,且目标物未能覆盖大多数常见常用的糖/盐CSs.本研究系统地优化了样品前处理过程和仪器分析中...  相似文献   

11.
The accuracy, repeatability, and reproducibility characteristics of a method using multitoxin immunoaffinity column cleanup with liquid chromatography (LC) for determination of aflatoxins (AF; sum of aflatoxins B1, B2, G1, and G2) and ochratoxin A (OTA) in powdered ginseng and ginger have been established in a collaborative study involving 13 laboratories from 7 countries. Blind duplicate samples of blank, spiked (AF and OTA added) at levels ranging from 0.25 to 16.0 microg/kg for AF and 0.25 to 8.0 microg/kg for OTA were analyzed. A naturally contaminated powdered ginger sample was also included. Test samples were extracted with methanol and 0.5% aqueous sodium hydrogen carbonate solution (700 + 300, v/v). The extract was centrifuged, diluted with phosphate buffer (PB), filtered, and applied to an immunoaffinity column containing antibodies specific for AF and OTA. After washing the column with water, the toxins were eluted from the column with methanol, and quantified by high-performance LC with fluorescence detection. Average recoveries of AF from ginseng and ginger ranged from 70 to 87% (at spiking levels ranging from 2 to 16 microg/kg), and of OTA, from 86 to 113% (at spiking levels ranging from 1 to 8 microg/kg). Relative standard deviations for within-laboratory repeatability (RSDr) ranged from 2.6 to 8.3% for AF, and from 2.5 to 10.7% for OTA. Relative standard deviations for between-laboratory reproducibility (RSDR) ranged from 5.7 to 28.6% for AF, and from 5.5 to 10.7% for OTA. HorRat values were < or = 2 for the multi-analytes in the 2 matrixes.  相似文献   

12.
A reliable ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in peanuts and their derivative products was developed. The sample was extracted by 84% of acetonitrile aqueous solution and the extract was purified by a reliable solid phase extraction-based clean-up method. Then, the analytes were separated on Acquity UPLC HSS T3 column (100 mm × 2.1 mm, 1.8 μm particle size), and eluted with a mobile phase consisting of (A) water containing 0.1% formic acid and (B) acetonitrile/methanol (50/50, v/v). The separated compounds were detected with a Waters Micromass Quattro Ultima Pt tandem quadrupole mass spectrometer operating in positive electro-spray ionization using multiple reaction monitoring mode. The established method was extensively validated by determining the linearity (R2 ≥ 0.9990), average recovery (74.7-86.8%) and precision (relative standard deviation ≤ 10.9%). It was shown to be a suitable method for simultaneous determination of the six aflatoxins in peanuts and their derivative products. Finally, a total of 73 samples randomly collected from different areas in Zhejiang province were screened for aflatoxins with the proposed method. The results showed that 31 samples of peanut butter, 14 samples of fresh peanut and 5 samples of musty peanut were contaminated with aflatoxins. Meanwhile, this was the first report on aflatoxins M1 and M2, which were found in unprocessed peanuts and their derivative products.  相似文献   

13.
A novel fully automated method based on dual column switching using turbulent flow chromatography followed by liquid chromatography with tandem mass spectrometry was developed for the determination of aflatoxin B1, B2, G1, and G2 in corn powder, edible oil, peanut butter, and soy sauce samples. After ultrasound‐assisted extraction, samples were directly injected to the chromatographic system and the analytes were concentrated into the clean‐up loading column. Through purge switching, the analytes were transferred to the analytical column for subsequent detection by mass spectrometry. Different types of TurboFlowTM columns, transfer flow rate, transfer time were optimized. The limits of detection and quantification of this method ranged between 0.2–2.0 and 0.5–4.0 μg/kg for aflatoxins in different matrixes, respectively. Recoveries of aflatoxins were in range of 83–108.1% for all samples, matrix effects were in range of 34.1–104.7%. The developed method has been successfully applied in the analysis of aflatoxin B1, B2, G1, and G2 in real samples.  相似文献   

14.
An ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of aflatoxins B1, B2, G1, G2, M1 and M2 in traditional Chinese medicines (TCMs) was developed. The approach was characterized in details and a special focus was placed on the recovery rates of isolation procedure in different TCM matrices, i.e. rhizomes and roots, seeds, flowers, grasses and leaves. For this purpose, [13C17]-aflatoxinB1 was employed as the internal standard and a reliable solid phase extraction-based clean-up method was developed. The observed recovery rates of the six aflatoxins ranged from 85.6% to 117.6% in different matrices. Then, the established method was successfully applied to the determination of the six aflatoxins in various TCMs. For 30 commercial samples analyzed, 16 were contaminated with aflatoxins. The mean levels (incidence) of aflatoxins B1, B2, G1 and G2 in positive samples were 1.40 (68.8%), 1.27 (50.0%), 0.50 (43.8%) and 0.94 (43.8%) μg kg−1, respectively. Interestingly, aflatoxin M1 was detected in two samples with the maximal content of 0.70 μg kg−1. No sample was contaminated with aflatoxin M2. Meanwhile, a possible association between the contamination levels and the selected herbs was clarified in the present study.  相似文献   

15.
A rapid, highly specific and sensitive isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to measure N7-methylguanine (N7-MeG) in urine. 15N5-Labeled N7-MeG was synthesized to serve as an internal standard, and an on-line SPE cartridge was used for on-line sample cleanup and enrichment. The urine sample can be directly analyzed within 15 min without prior sample purification. The detection limit for this method was estimated as 8.0 pg/mL (4.8 pmol) on-column. This method was further applied to study exposure to methylating agents arising from cigarette smoke. Sixty-seven volunteers were recruited, including 32 regular smokers and 35 nonsmokers. Urinary cotinine, a major metabolite of nicotine, was also determined using an isotope-dilution LC/MS/MS method. The results showed that urinary levels of N7-MeG observed in smokers (4215 +/- 1739 ng/mg creatinine) were significantly (P < 0.01) higher than those in nonsmokers (3035 +/- 720 ng/mg creatinine). It was further noted that the urinary level of N7-MeG was found to be correlated with that of cotinine for smokers, implying that cigarette smoking resulted in increased DNA methylation, followed by depurination and excretion of N7-MeG in urine. As a result of the on-line extraction system, this method is capable of routine high-throughput analysis and accurate quantitation of N7-MeG, and could be a useful tool for health surveillance of methylating agent exposure.  相似文献   

16.
17.
A simple, reliable, and highly sensitive method for the simultaneous determination of aflatoxin B1, B2, G1, G2 in Fructus Bruceae was developed using high‐performance liquid chromatography coupled to online postcolumn photochemical derivatization and fluorescence detection. Aflatoxins were first extracted by a methanol/water mixture and then cleaned up with an AflaTest? immunoaffinity column. Different clean‐up and derivatization methods were compared and optimized. The established method was extensively validated to show satisfactory performance of linearity (R2 ≥ 0.9997), recovery (74.3–100.8%), and precision (RSDs ≤ 2.8%) for the investigated aflatoxins. This proposed method was also applied to 11 F. Bruceae samples and the results showed that 10 out of 11 were contaminated with aflatoxins ranging from 0.26 to 27.52 μg/kg and the occurrence of aflatoxin B1, the most toxic one, was as high as 91% in all the samples, highlighting the severe contamination and the necessity to set legal limits for aflatoxins in F. Bruceae.  相似文献   

18.
Tuomi T  Johnsson T  Hintikka EL  Reijula K 《The Analyst》2001,126(9):1545-1550
A method is described for the simultaneous determination of common aflatoxins (G1, G2, B1, B2) and their precursor sterigmatocystin, and also citrinine and ochratoxin A. The method was applied to a building material matrix artificially contaminated with mycotoxin-producing fungi. The method includes extraction, sample pre-treatment and reversed-phase HPLC separation with tandem mass spectrometric identification and quantification using electrospray ionisation on a quadrupole ion trap mass analyser (ESI-MS-MS). Aqueous methanol was used in the initial extraction and solvent partitioning and solid phase extraction in the purification of samples. The HPLC separation was run on-line with the ESI-MS-MS detection. The limit of quantification of the procedure was 200 ng for all compounds. Recoveries of the sample pre-treatment varied from 28 to 99%. The average compound- and concentration-dependent accuracy and precision (RSD) were 21 and 113%, respectively. The method includes small sample volumes (approximately 1 g in 20 ml) and few, non-labour intensive, sample treatment steps. It should allow for a high throughput of samples with good prospects of automation.  相似文献   

19.
The application of dispersive liquid-liquid microextraction (DLLME) technique for the rapid analysis of aflatoxins B(1), B(2), G(1) and G(2) in maize, rice and wheat products has been evaluated. After extraction of aflatoxins from cereal matrices with a mixture of methanol/water 8:2 (v/v), the analytes were rapidly transferred from the extract to another small volume of organic solvent, chloroform, by DLLME. Aflatoxins were determined using high performance liquid chromatography with florescence detection and photochemical post-column derivatization. Parameters affecting both extraction and DLLME procedures, such as extraction solvent, type and volume of DLLME extractant, volume of water and salt effect, were systematically investigated and optimized to achieve the best extraction efficiency. Under the optimal experimental conditions, the whole analytical method provides enrichment factors around 2.5 times and detection limits (0.01-0.17 μg kg(-1)) below the maximum levels imposed by current regulation for aflatoxins in cereals and cereal products intended for direct human consumption. Recoveries (67-92%) and repeatability (RSD<10, n=3), tested in three different cereal matrices, meet the performance criteria required by EC Regulation No. 401/2006 for the determination of the levels of mycotoxins in foodstuffs. The proposed method was successfully applied to the analysis of retail cereal products with quantitative results comparable to the immunoaffinity chromatography (IAC). The main advantages of developed method are the simplicity of operation, the rapidity to achieve a very high sample throughput and low cost.  相似文献   

20.
A new method for the determination of ochratoxin A and T-2 toxin in alcoholic beverages (wine and beer) by hollow fiber liquid microextraction was optimized. The extraction step was followed by ultra high-pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The extraction procedure was based on the extraction of mycotoxins from the sample to the organic solvent (1-octanol) immobilized in the fiber, and afterwards, they were desorbed in a mixture of acetonitrile/water (80:20, v/v) at pH 7 prior to chromatographic determination. Different variables affecting the extraction process such as organic solvent, salt content, extraction time and desorption solution were studied. The developed method was validated in wine and beer, using white wine and alcoholic beer as representative matrices for both types of samples. Relative recoveries higher than 70% were obtained for the selected mycotoxins. Good linearity (R2 > 0.993) was obtained and quantification limits (0.02-0.09 μg L−1) below European regulatory levels were achieved. Repeatability, expressed as relative standard deviation, was always lower than 12%, whereas interday precision was lower than 21%. The proposed method was applied to the analysis of several types of wines and beers and ochratoxin A was detected in a rosé wine at 1.1 μg L−1.  相似文献   