首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A high-pressure liquid chromatography-diode array detection and multi-mode ionization tandem mass spectrometry (HPLC-DAD–MMI-MS/MS) method was used to identify amino-tadalafil and rimonabant in electronic cigarette (e-cigarette) cartridges. Amino-tadalafil is a drug analogue of the commercially approved Cialis? (i.e. tadalafil). Rimonabant is a drug that was, at one time, approved for weight loss in Europe (although approval has been retracted), but not in the United States. In addition, poor quality control over the e-cigarette products analyzed here is shown by the presence of nicotine in products labeled as containing no nicotine or by the presence of significant amounts of rimonabant oxidative degradant in e-cigarette products containing rimonabant. Identification was accomplished by comparing the retention time of relevant peaks in the sample with those of standard compounds, in addition to comparison of the UV spectra, mass spectra and/or product ion mass spectra.  相似文献   

2.
Haloacetic acids (HAAs) were determined in different water samples by a new, fast and simple analysis method based on enrichment of 50-ml water samples at pH 1.8 by solid-phase extraction (SPE) followed by liquid chromatography (LC) separation and electrospray ionization mass spectrometric detection in the negative ionization mode. Deprotonated (M-H)-haloacetates and decarboxylated (M-COOH)- ions were detected. Different polymeric SPE sorbents were tested, and LiChrolut EN was found to be the best material for the extraction. Complete LC separation of all compounds could only be achieved by ion-pair chromatography using triethylamine as volatile ion-pairing reagent. The detection limits were in the low microg/l range. High microg/l concentration levels for the chlorinated and brominated haloacetates were found in drinking water from a drinking water treatment plant in Barcelona, and the corresponding tap water. In swimming pool water samples from Catalonia mg/l levels and in surface river water from Portugal microg/l values were detected. These results confirm other recent reports on the ubiquitous occurrence of HAAs in aqueous environments.  相似文献   

3.
A method has been developed for confirmation and quantitation of ten sulfonylurea herbicides (nicosufuron, thifensulfuron-methyl, metsulfuron-methyl, sulfometuron-methyl, chlorsulfuron, ethametsulfuron-methyl, tribenuron, bensulfuron-methyl, pyrazosulfuron-ethyl and chlorimuron-ethyl) in water samples. Herbicides were extracted from water by off-line solid-phase extraction (SPE). Different types of absorbents were evaluated: silica-based ODS-C18 and two polymeric sorbents, Cleanert HXN and Oasis HLB. Analyte determination and quantitation was performed by liquid chromatography with electrospray mass spectrometry (LC-ESI-MS) instrumentation, equipped with ion trap mass filter. Confirmatory analysis was carried out by LC/MS/MS. MS data acquisition was performed by a single or two-ion extracted ion monitoring program. The ten herbicides were measured in fortified tap water. Average recoveries of the nine analytes (except for tribenuron) from water samples were in the range of 77–109%, and the RSD ranged from 0.3 to 14.5%. The limit of detections (LODs) varied from 6 to 34.8 ng/L.  相似文献   

4.
A method has been developed for the simultaneous determination of resveratrol in all its forms (free isomers and glycosylates) in wines by high-performance liquid chromatography with diode array and mass spectrometric detection. Prior to injection into the column, preconcentration of the sample by automated solid-phase extraction is carried out. In the detection by UV absorption, quantitation was carried out at 280 and 305 nm, and in detection by mass spectrometry, quantitation was performed in the selected ion monitoring mode at m/z 228 and at m/z 238. A comparative study between both detection systems was carried out.  相似文献   

5.
张海超  艾连峰  马育松  王敬  李晓菲 《色谱》2018,36(10):991-998
以疏水的聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)整体柱作为固相萃取柱,建立了大米中15种酰胺类除草剂残留的在线固相萃取结合高效液相色谱-串联质谱测定的方法。本方法采用乙腈提取目标化合物,经在线整体柱净化,Hypersil GOLD色谱柱分离,流动相采用0.5%(v/v)甲酸水溶液-乙腈进行梯度洗脱,在电喷雾正离子模式下以多反应监测(MRM)方式测定。15种除草剂的线性关系良好,相关系数(r)大于0.998。方法检出限和定量限为0.20~2.0 μg/kg和0.50~5.0 μg/kg。待测物在2.0、5.0、10.0、50.0 μg/kg(敌稗为5.0、10.0、50.0、100 μg/kg)4个浓度水平下加标回收率为75.5%~121.3%,相对标准偏差为2.89%~12.38%。该方法快速简便,灵敏度高,可用于大米中酰胺类除草剂的快速定性定量分析。  相似文献   

6.
A multianalyte method has been developed for the confirmation and quantitation of five sulfonylureas, bensulfuron-methyl, imazosulfuron, pyrazosulfuron-ethyl, flazasulfuron and halosulfuron-methyl, and for three ureas, siduron, dymron (daimuron) and diuron (DCMU) in water. Samples were extracted from water by off-line solid-phase extraction (SPE) with a polystyrene polymer cartridge (PS2), an ODS C18-bonded silica cartridge (C18) and an N-vinylpyrrolidone polymer cartridge (Oasis). Analyte determination and quantitation were performed by liquid chromatography with mass spectrometry (LC-MS). Extraction efficiency experiments demonstrated the ability of this method to extract sulfonylureas and ureas from water samples. Confirmatory analysis was carried out by LC-electrospray mass spectrometry (LC-ESI-MS) instrumentation equipped with a single-quadrupole mass filter. MS data acquisition was performed by a single or two-ion selected ion monitoring (SIM) program. It is required for confirmation that LC-MS retention times of the analytes are within 1% of the retention times of the standards, and that the molecular ion or characteristic fragment ion is present for each analyte. Fragment ions from distinctive structures must be obtained to identify and characterize specific herbicide molecules. These were obtained by controlled decomposition of sulfonylurea and urea adduct ions after suitably adjusting the electrical field in the desolvation chamber. The eight herbicides were also measured in fortified pure water (water purified by a milli-Q system), tap water and river water. Average recoveries of the eight analytes from water samples were in the range of 70-120% with relative standard deviations (R.S.D.s) of <20%. The limit of quantitation (LOQ) for each of the eight herbicides was between 10 and 100 ng l−1.  相似文献   

7.
Methods using liquid chromatography/mass spectrometry (LC/MS) and LC with diode array detection (DAD) in the UV range (LC/UV) were developed for the determination of low levels of the anthraquinones aloe-emodin and aloin-A (barbaloin) in aloe-based products. The methods were used to analyze several commercial products (liquids, semisolids, and solids) for the 2 anthraquinones. The wavelengths used for quantification of aloin-A, aloe-emodin, and emodin (internal standard) by DAD were 357, 257, and 289 nm, respectively. The on-column sensitivities were 0.25 and 0.05 ng by LC/UV and 0.01 and 0.025 ng by LC/MS for aloin-A and aloe-emodin, respectively. The methods are simple and sensitive and provide reproducible results; therefore, they are suitable for the determination of these anthraquinones in various aloe-based products.  相似文献   

8.
A highly sensitive analytical procedure is described for determining thiodiglycol in groundwater. Samples are initially fortified with 3,3'-thiodipropanol (surrogate), then both species are extracted using sequential solid-phase extraction with both C18 and Ambersorb 572 columns. The C18 column, which removes extraneous groundwater components, is discarded; the Ambersorb 572 column is dried thoroughly before eluting polar components with a small volume of dichloromethane. The extract is taken to dryness using dry flowing nitrogen, and the resulting residue is derivatized using N-(tert.-butyldimethylsilyl)-N-methyltrifluoroacetamide and pyridine. The derivatized products are diluted to a final volume with toluene, chromatographed using a fused-silica capillary column, and detected with a quadrupole mass spectrometric detector in its selected-ion mode. Two independent, statistically unbiased, procedures were used to evaluate the detection limits for thiodiglycol; the values ranged between 4 and 16 microg(-1) groundwater.  相似文献   

9.
The present investigation describes the employment of a comprehensive 2-D HPLC system, based on the combination of a silver ion and an RP column, for the characterization of the triacylglycerol (TAG) fraction of a very complex lipidic sample: donkey milk fat. The TAGs were grouped on the resulting bidimensional contour plot according to their double bond numbers (aligned along vertical bands) and according to their partition numbers (aligned along horizontal bands). Peak assignment was supported by using atmospheric pressure chemical ionization mass spectrometric (APCI-MS) detection. The combination of the enhanced resolving power of comprehensive multidimensional LC, the formation of ordered 2-D patterns, and APCI-MS detection proved to be an effective tool for the characterization of the complex matrix, enabling the separation and identification of nearly 60 TAGs.  相似文献   

10.
An analytical method for the determination of residues of the antibiotic drugs lincomycin and tylosin in honey was developed. The procedure employed a solid-phase extraction for the isolation of lincomycin and tylosin from diluted honey samples. The antibiotic residues were subsequently analyzed by reversed-phase HPLC with atmospheric pressure chemical ionization mass spectrometric detection. Average analyte recoveries for lincomycin and tylosin ranged from 84 to 107% in replicate sets of honey samples fortified with drug concentrations of 0.01, 0.5, and 10 microg/g. The method detection limits were determined to be 0.007 and 0.01 microg/g for lincomycin and tylosin, respectively.  相似文献   

11.
12.
A simple, selective and sensitive method for the determination of carboxylic acids has been developed. A mixture of formic, acetic, propionic, valeric, isovaleric, isobutyric, and isocaproic acids has been separated on a polymethacrylate-based weak acidic cation-exchange resin (TSK gel OA pak-A) based on an ion-exclusion chromatographic mechanism with detection using UV-photodiode array, conductivity and atmospheric pressure chemical ionization mass spectrometry (APCI-MS). A mobile phase consisting of 0.85 mM benzoic acid in 10% aqueous methanol (pH 3.89) was used to separate the above carboxylic acids in about 40 min. For LC-MS, the APCI interface was used in the negative ionization mode. Linear plots of peak area versus concentration were obtained over the range 1-30 mM (r2=0.9982) and 1-30 mM (r2=0.9958) for conductimetric and MS detection, respectively. The detection limits of the target carboxylic acids calculated at S/N=3 ranged from 0.078 to 2.3 microM for conductimetric and photometric detection and from 0.66 to 3.82 microM for ion-exclusion chromatography-APCI-MS. The reproducibility of retention times was 0.12-0.16% relative standard deviation for ion-exclusion chromatography and 1.21-2.5% for ion-exclusion chromatography-APCI-MS. The method was applied to the determination of carboxylic acids in red wine, white wine, apple vinegar, and Japanese rice wine.  相似文献   

13.
A detailed comparison of the repeatability of the retention times, the peak efficiencies and the peak areas of a dozen probe compounds achieved in HPLC, using either HPLC-UV or HPLC-MS for detection purpose, is reported. Three groups of conventional analytes, each one separated under a different set of experimental conditions, were selected for this study. Most of the compounds are basic, the other ones being neutral. The repeatabilities of the retention times do not exhibit any influence of the mode of detection. However, the repeatabilities of the peak areas and the column efficiencies are generally (although not always) better in HPLC-UV than that in HPLC-MS. On average, the precision for the UV peak area detection was 2.5% versus 6.8% for MS detection. Experimental results show that the response factor of the UV detector is more constant than that of the MS detector, probably because the HPLC flow-rate was sufficiently stable. The results obtained in the different tests are discussed.  相似文献   

14.
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam? LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.  相似文献   

15.
Ion suppression is a well-known phenomenon in electrospray ionization (ESI) mass spectrometry. These suppression effects have been shown to adversely affect the accuracy and precision of quantitative bioanalytical methods using ion spray. Such suppression effects have not been as well defined in atmospheric pressure chemical ionization (APCI) and there is some debate whether these effects actually occur in the ionization process using APCI. Here an example is described where clear ion suppression was observed during studies on a model compound and three metabolites using APCI liquid chromatography/tandem mass spectrometry (LC/MS/MS).  相似文献   

16.
The desorption of an analyte by a continuous wave diode laser from a porous surface of a thin-layer plate covered with a graphite suspension is presented. The thermally desorbed analyte molecules are ionized in the gas phase by a corona discharge at atmospheric pressure. Therefore, both essential processes--the desorption and the ionization of analyte molecules, which are often performed in one step--are separated. The target preparation is easy and fast since no additional extraction process is required. The mass spectrometric background signal was mostly limited to the low mass range showing no interference with typical compounds of interest. In this study, the calmative and antihypertensive drug reserpine was chosen as model analyte, which is often used for specification of mass spectrometers. No fragmentation was observed because of efficient collisional cooling under atmospheric pressure. The influence of diode laser power and the composition of the graphite suspension were investigated, and a primary optimization was performed.  相似文献   

17.
On-line high performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (HPLC/APCI-MS) has been applied to the identification of a number of tetrapyrrolic pigments as well as several magnesium-free analogs. Mass spectra, acquired both in positive (+) and negative (-) ionization mode, allow not only the determination of the structural features of the pigments, but also a very easy differentiation of the Mg-chelated pigments from the free bases. In the positive ionization mode, all pigments show mainly a [M + H]+ ion and a [M + H - C20H38]+ fragment ion corresponding to the loss of the phytyl chain via a hydrogen rearrangement. In the negative ionization mode, on the other hand, although all pigments give an abundant molecular anion [M]-*, only the Mg-chelated chlorin spectra show a prominent fragment [M - C20H39]- produced by a formal loss of the phytyl radical.  相似文献   

18.
A method based on solid-phase extraction coupled to liquid chromatography with positive ion electrospray ionization and tandem mass spectrometric detection was developed for the determination of didanosine in human serum, using lamivudine as internal standard. The acquisition was performed in the multiple reaction monitoring mode, monitoring the transitions m/z 237 --> 136.7 for didanosine and m/z 230 --> 111.7 for lamivudine. The method was linear over the range studied (10-1500 ng ml(-1)), with r(2) > 0.98, and the run time was 5 min. The intra- and inter-assay precisions were < or =10% and the intra- and inter-assay accuracies were >95%. The absolute recoveries were 99.8% (10 ng ml(-1)), 98.4% (30 ng ml(-1)), 91.5% (700 ng ml(-1)) and 94.7% (1200 ng ml(-1)). The limits of detection and quantitation were 5 and 10 ng ml(-1), respectively. The method was applied to a bioequivalence study, in which 24 healthy adult volunteers (12 men) received single oral doses (200 mg) of reference and test didanosine formulations (buffered powder for oral solutions), in an open, two-way, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak serum concentration) and AUC(0-inf) (area under the serum concentration versus time curve from time zero to infinity) were within the range 80-125%, which supports the conclusion that the two formulations are bioequivalent regarding the rate and extent of didanosine absorption.  相似文献   

19.
Using the high performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (HPLC/APCI-MS/MS) technique, together with established trends from the literature, the structures of metabolites and impurities of amiodarone, an anti-arrhythmic drug, have been assigned. By comparing analyses of products of incubation with rat liver microsomes with controls in which glucose 6-phosphate dehydrogenase was omitted, metabolites could be distinguished from impurities. Structures for the two proposed metabolites and four impurities are proposed.  相似文献   

20.
A liquid chromatography with diode array detection coupled to dual electrospray atmospheric pressure chemical ionization time-of-flight mass spectrometry (HPLC/ESI-APCI-TOF-MS) method is described for the rapid determination of five monophosphate nucleotides (cytidine 5′-monophosphate, uridine 5′-monophosphate, adenosine 5′-monophosphate, inosine 5′-monophosphate and guanosine 5′-monophosphate) in baby foods. The method is based on the deproteinisation of foods and direct analysis of nucleotides by ion-pair HPLC using isocratic elution with a mobile phase of 5% (v/v) methanol and 95% (v/v) 0.1 M formate buffer (pH 5.5) containing 0.01 M N,N-dimethylhexylamine (DMHA) at a flow-rate of 0.7 mL min−1. The HPLC was hyphenated with two different detection systems, photodiode-array (DAD) and ESI-APCI-TOF-MS in negative mode. The method was validated for linearity, detection and quantitation limits, selectivity, accuracy and precision. The recoveries obtained for spiked samples were satisfactory for all the analytes. The method was successfully applied to the analysis of nucleotides in different baby and/or functional food samples, as cereals, purees and dairy products. A study was also carried out on the stability of nucleotides in acidified dairy infant food with pasteurized yoghourt and follow-on formulae samples stored at room temperature and at 30 °C.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号