首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple and efficient method based on hollow fiber protected headspace liquid-phase in conjunction with high performance liquid chromatography has been introduced for extraction and determination of three residual monomers (2-ethylhexyl acrylate (EHA), vinyl acetate (VA), glycidyl methacrylate (GM)) in polymer latex. Using this methodology, the analytes of interest extracted from a sample are led into organic solvent located inside the porous hollow fiber membrane. Initially, several experimental parameters were controlled and optimized and the optimum conditions were reached with 8 cm neatly cut hollow fibers containing heptanol, which were exposed to the headspace of a 12 mL sample solution containing 20% (w/v) NaCl thermostated at 110 °C and stirred at 800 rpm for 20 min. Finally, 20 μL of the extraction solution was withdrawn into a syringe and injected into HPLC for analysis. The calibration curves were linear (r2 ≥ 0.994) over the concentration range of 0.05-10 mg L−1 for VA and 0.02-10 mg L−1 for other analytes. The relative standard deviation (RSD%) for three-replicate extractions and measurements was below 8.6%. The limits of detection of this method for quantitative determination of the analytes were found within the range of 0.005 to 0.011 mg kg−1 with the enrichment factors within the 5-164 range. The method was successfully applied for determination of residual monomers in polymer latex.  相似文献   

2.
A simple and efficient hollow fiber liquid‐phase microextraction (HF‐LPME) technique in conjunction with high‐performance liquid chromatography is presented for extraction and quantitative determination of aristolochic acid I in human urine samples. Several parameters influencing the efficiency of HF‐LPME were investigated and optimized, including extraction solvent, stirring rate, extraction time, pH of donor phase and acceptor phase. Excellent sample clean‐up was observed and good linearity with coefficient of 0.9999 was obtained in the range of 15.4–960 µg/L. This method provided a 230‐fold enrichment factor and good repeatability with relative standard deviations (RSD) lower than 6.0%. The limit of detection value for the analyte in urine sample was 0.01 µg/L at a signal‐to‐noise ratio of 3. The extraction recovery from urine samples was 61.8% with an RSD of 9.71%. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
In this work, three-phase liquid-phase microextraction (LPME) based on a supported liquid membrane (SLM) sustained in the wall of a hollow fiber was investigated with special focus on optimization of the experimental procedures in terms of recovery and repeatability. Recovery data for doxepin, amitriptyline, clomipramine, and mianserin were in the range of 67.8-79.8%. Within-day repeatability data for the four basic drugs were in the range of 4.1-7.7%. No single factor was found to be responsible for these variations, and the variability was caused by several factors related to the LPME extractions as well as to the final HPLC determination. Although the volume of the SLM varied within 0.4-3.1% RSD depending on the preparation procedure, and the volume of the acceptor solution varied within 4.8% RSD, both recoveries and repeatability were found to be relative insensitive to these variations. Thus, the handling of microliters of liquid in LPME was not a very critical factor, and the preparation of the SLM was accomplished in several different ways with comparable performance. Reuse of hollow fibers was found to suffer from matrix effects due to built-up of analytes in the SLM, whereas washing of the hollow fibers in acetone was beneficial in terms of recovery, especially for the extraction of the most hydrophobic substances. Several of the organic solvents used in the literature as SLM suffered from poor long-term stability, but silicone oil AR 20 (polyphenylmethylsiloxane), 2-nitrophenyl octyl ether (NPOE), and dodecyl acetate (DDA) all extracted with unaltered performance even after 60 days of storage at room temperature.  相似文献   

4.
The presence of pharmaceuticals in the environment due to growing worldwide consumption has become an important problem that requires analytical solutions. This paper describes a CE determination for several nonsteroidal anti‐inflammatory drugs (ibuprofen, naproxen, ketoprofen, diclofenac, ketorolac, aceclofenac and salicylic acid) in environmental waters using hollow fiber membrane liquid‐phase microextraction. The extraction was carried out using a polypropylene membrane supporting dihexyl ether and the electrophoretic separation was performed in acetate buffer (30 mM, pH 4) using ACN as the organic modifier. Detection limits between 0.25 and 0.86 ng/mL were obtained, respectively. The method could be applied to the direct determination of the seven anti‐inflammatories in wastewaters, and five of them have been determined or detected in different urban wastewaters.  相似文献   

5.
A new and simple method has been developed for the determination of a group of four benzimidazole pesticides (carbendazim/benomyl, thiabendazole, and fuberidazole), a carbamate (carbaryl), and an organophosphate (triazophos), together with two of their main metabolites (2-aminobenzimidazole, metabolite of carbendazim/benomyl, and 1-naphthol, metabolite of carbaryl) in soils. First, an ultrasound-assisted extraction (UAE) was performed, followed by evaporation and reconstitution in water. Then, extraction and preconcentration of the analytes was accomplished by two-phase hollow-fiber liquid-phase microextraction (HF-LPME) using 1-octanol as extraction solvent. Parameters that affect the extraction efficiency in HF-LPME technique (organic solvent, pH of the sample, extraction time, stirring speed, temperature, and ionic strength) were deeply investigated. Optimum HF-LPME conditions involved the use of a 2.0 cm polypropylene fiber filled with 1-octanol to extract 10 mL of an aqueous soil extract at pH 9.0 containing 20% (v/v) of NaCl for 30 min at 1440 rpm. Separation and quantification was achieved by HPLC with fluorescence detection (FD). The proposed optimum UAE-HF-LPME-HPLC-FD methodology provided good calibration, precision, and accuracy results for two soils of different physicochemical properties. LODs were in the range 0.001-6.94 ng/g (S/N = 3). With the aim of extending the validation, the HF-LPME method was also applied to different types of waters (Milli-Q, mineral and run-off), obtaining LODs in the range 0.0002-0.57 μg/L.  相似文献   

6.
A new method, which involves dynamic liquid-phase microextraction followed by HPLC with variable wavelength detection, was developed to determine phoxim in water samples. Experimental parameters affecting the extraction efficiency, such as extraction solvent, solvent volume, sampling volume, dwell time, number of samplings, and salt concentration were investigated. Under the optimal extraction conditions, phoxim was found to yield a good linear calibration curve in the concentration range from 0.01 to 10 microg/mL. The LOD is 2 ng/mL, and RSD at the 100 ng/mL levels is 8.9%. Lake water and tap water samples were successfully analyzed using the proposed method.  相似文献   

7.
In this work, the potential of a symmetric dialkyl‐substituted ionic liquid (IL), 1,3‐dipenthylimidazolium hexafluorophosphate ([PPIm][PF6]), as extraction solvent in dispersive liquid–liquid microextraction (DLLME) has been studied for the analysis of a group of three natural (estriol, 17β‐estradiol, and 17α‐estradiol) and four synthetic (17α‐ethynylestradiol, diethylstibestrol, dienestrol, and hexestrol) estrogenic compounds as well as one mycotoxin with estrogenic activity (zearalenone) in different types of water samples (Milli‐Q, mineral, and wastewater). Separation, determination, and quantification were developed by HPLC‐DAD and a fluorescence detector (FD) connected in series. Factors influencing the IL‐DLLME procedure (sample pH, amount of IL, type and volume of disperser solvent, ionic strength, and assistance of vortex agitation) were investigated and optimized by means of a step‐by‐step approach. Once the optimum extraction conditions were established (10 mL of water at pH 8, 60 mg of [PPIm][PF6], 500 μL of ACN as disperser solvent and vortex agitation for 1 min), the calibration curves of the whole method (IL‐DLLME‐HPLC‐DAD/FD) were obtained and precision and accuracy were evaluated. It was demonstrated that the developed methodology was repeatable, accurate, and selective with limits of detection in the 0.30–0.57 μg/L and 13.8–37.1 μg/L range for FD and DAD, respectively. Relative recovery values were higher than 85% for the different types of water samples and the Student's t test demonstrated that there were not significant differences between the added and the found concentration.  相似文献   

8.
An automated dynamic two-phase hollow fiber microextraction apparatus combined with high-performance liquid chromatography was developed for extraction and determination of chlorophenoxy acid (CPA) herbicides from environmental samples. The extraction device, called TT-extractor, consists of a polypropylene hollow fiber mounted inside a stainless steel tube by means of two tee-connectors in flow system. An organic solvent, which fills the lumen and the pores of the hydrophobic fiber, is pumped through the fiber repeatedly and the sample is pumped along the outer side of the fiber. The factors affecting the dynamic hollow fiber liquid-phase microextraction (DHF-LPME) of target analytes were investigated and the optimal extraction conditions were established. To test the applicability of the designed instrument, CPAs were extracted from environmental aqueous samples. The limits of detection (LODs) as low as 0.5 μg/L, linear dynamic range in the range of 1-100 μg/L and the relative standard deviations of <7% were obtained. The developed method can provide perconcentration factors as large as 230. A hollow fiber membrane can be used at least 20 times with neither loss in the efficiency nor carryover of the analytes between runs. The system is cheap and convenient and requires minimal manual handling.  相似文献   

9.
采用中空纤维液相微萃取与高效液相色谱联用技术测定了尿液样品中的痕量己烯雌酚;考察了样品相酸度、中间相种类、接收相浓度、搅拌速度、萃取时间等对液-液-液三相微萃取效率的影响,进而确定了最佳萃取条件.结果表明,当样品相pH为2.5,中间相为甲苯,接收相为3μL 0.25mol/L氢氧化钠溶液,搅拌速度为800r/min,萃取时间为50min时,萃取效率最佳.在最佳萃取条件下,样品的回收率为76.4%,相对标准偏差为3.8%.  相似文献   

10.
朱颖  陈璇  郑飞浪  白小红 《色谱》2009,27(6):769-775
在优化的三相中空纤维液相微萃取(3p-HFLPME)条件下,研究了6种羟基苯甲酸类化合物(HBAs)的3p-HFLPME行为;揭示了HBAs的富集因子(EF)与其正庚醇/水条件分配系数(log Pn-heptanol/5 mmol/L HCl)、pKa和羟基数目(N)的相关性,初步阐明了聚偏氟乙烯中空纤维对HBAs的电荷转移传递机理以及有机溶剂对HBAs的选择性萃取机理。优化的3p-HFLPME条件: 以MOF 503聚偏氟乙烯中空纤维为有机溶剂支持体,正庚醇为有机相,5 mmol/L HCl体系为给体,80 mmol/L NH3·H2O为接受相,搅拌速度为1200 r/min,萃取35 min。该方法的精密度(以相对标准偏差计)小于3%,检出限为0.09~30.00 μg/L,加标回收率为93.3%~107.1%,HBAs质量浓度为5 mg/L时的富集因子最高达107.6倍。  相似文献   

11.
This paper describes an extraction method using a polypropylene membrane supporting dihexyl ether (three-phase hollow fiber-based liquid phase microextraction (HF-LPME)) for the analysis of several pharmaceuticals (salicylic acid (SAC), ibuprofen (IBU) and diclofenac (DIC)) followed by a HPLC determination using a monolithic silica type HPLC column, that allows lower retention times than the usual packed columns with adequate resolution. Detection was realized by means of a coupled in series diode array (DAD) and fluorescence (FLD) detectors. HF-LPME is a relatively new technique employed in analytical chemistry for sample pretreatment which offers more selectivity and sensitivity than any traditional extraction technique. Detection limits by DAD are 12, 53 and 40 ng mL−1 for salicylic acid, diclofenac and ibuprofen, respectively and by FLD 7 and 2 ng mL−1 for salicylic acid, and ibuprofen. The method has been successfully applied to their direct determination in human urine and the results obtained demonstrated that could be also applied to the determination of the corresponding metabolites.  相似文献   

12.
Hollow fiber-based liquid-phase microextraction (HF-LPME) is a relatively new technique employed in analytical chemistry for sample pretreatment which offers more selectivity and sensitivity than any traditional extraction technique. This paper describes a three-phase HF-LPME method for ibuprofen using a polypropylene membrane supporting dihexyl ether followed by a chemiluminescence (CL) determination using the CL enhancement on the acidic permanganate-sulfite system in a FIA configuration which is the first time that both techniques have been combined for analytical purposes. The CL intensity (peak area) was proportional to the log of ibuprofen concentration in the donor phase over the range 0.1-20 μg mL−1. The detection limit was 0.03 μg mL−1 of ibuprofen in the donor phase. The method was satisfactory reproducible and has been applied to the ibuprofen determination in pharmaceuticals and in real human urine samples.  相似文献   

13.
A three-phase hollow-fiber liquid-phase microextraction (HF-LPME) method for the stereoselective determination of bufuralol metabolites 1'-oxobufuralol (1'-Oxo-BF) and 1'-hydroxybufuralol (1'-OH-BF) in microsomal preparations is described for the first time. The HPLC analysis was carried out using a Chiralcel OD-H column with hexane/2-propanol/methanol (97.5:2.0:0.5, v/v/v) plus 0.5% diethylamine as the mobile phase, and UV detection at 248 and 273 nm. The HF-LPME optimized conditions involved: n-octanol as the organic solvent, 0.2 mol/L acetic acid as the acceptor phase, donor phase pH adjusted to 13, sample agitation at 1500 rpm and extraction for 30 min. By using this extraction procedure, the recovery rates were in the range of 63-69%. The method was linear over the concentration range of 100-5000 ng/mL for each enantiomer of 1'-Oxo-BF (r>0.9978) and of 100-2500 ng/mL for each stereoisomer of 1'-OH-BF (r>0.9957). The quantification limits were 100 ng/mL for all analytes. The validated method was used to assess the in vitro biotransformation of bufuralol using rat liver microsomal fraction that demonstrated predominant formation of (S)-1'-Oxo-BF and (R,R)-1'-OH-BF.  相似文献   

14.
In this paper, extraction kinetics was investigated experimentally and theoretically in hollow fiber liquid-phase microextraction (HF-LPME) and electromembrane extraction (EME) with the basic drugs droperidol, haloperidol, nortriptyline, clomipramine, and clemastine as model analytes. In HF-LPME, the analytes were extracted by passive diffusion from an alkaline sample, through a (organic) supported liquid membrane (SLM) and into an acidic acceptor solution. In EME, the analytes were extracted by electrokinetic migration from an acidic sample, through the SLM, and into an acidic acceptor solution by application of an electrical potential across the SLM. In both HF-LPME and EME, the sample (donor solution) was found to be rapidly depleted for analyte. In HF-LPME, the mass transfer across the SLM was slow, and this was found to be the rate limiting step of HF-LPME. This finding is in contrast to earlier discussions in the literature suggesting that mass transfer across the boundary layer at the donor–SLM interface is the rate limiting step of HF-LPME. In EME, mass transfer across the SLM was much more rapid due to electrokinetic migration. Nevertheless, mass transfer across the SLM was rate limiting even in EME. Theoretical models were developed to describe the kinetics in HF-LPME, in agreement with the experimental findings. In HF-LPME, the extraction efficiency was found to be maintained even if pH in the donor solution was lowered from 10 to 7–8, which was below the pKa-value for several of the analytes. Similarly, in EME, the extraction efficiency was found to be maintained even if pH in the donor solution increased from 4 to 11, which was above the pKa-value for several of the analytes. The two latter experiments suggested that both techniques may be used to effectively extract analytes from samples in a broader pH range as compared to the pH range recommended in the literature.  相似文献   

15.
In hollow fiber membrane liquid-phase microextraction (LPME), target analytes are extracted from aqueous samples and into a supported liquid membrane (SLM) sustained in the pores in the wall of a small porous hollow fiber, and further into an acceptor phase present inside the lumen of the hollow fiber. The acceptor phase can be organic, providing a two-phase extraction system compatible with capillary gas chromatography, or the acceptor phase can be aqueous resulting in a three-phase system compatible with high-performance liquid chromatography or capillary electrophoresis. Due to high enrichment, efficient sample clean-up, and the low consumption of organic solvent, substantial interest has been devoted to LPME in recent years. This paper reviews important applications of LPME with special focus on bioanalytical and environmental chemistry, and also covers a new possible direction for LPME namely electromembrane extraction, where analytes are extracted through the SLM and into the acceptor phase by the application of electrical potentials.  相似文献   

16.
A new and fast sample preparation technique based on three‐phase hollow fiber liquid‐phase microextraction with a magnetofluid was developed and successfully used to quantify the aristolochic acid I (AA‐I) and AA‐II in plasma after oral administration of Caulis akebiae extract. Analysis was accomplished by reversed‐phase high‐performance liquid chromatography with fluorescence detection. Parameters that affect the hollow fiber liquid‐phase microextraction processes, such as the solvent type, pH of donor and acceptor phases, content of magnetofluid, salt content, stirring speed, hollow fiber length, extraction temperature, and extraction time, were investigated and optimized. Under the optimized conditions, the preconcentration factors for AA‐I and AA‐II were >627. The calibration curve for two AAs was linear in the range of 0.1–10 ng/mL with the correlation coefficients >0.9997. The intraday and interday precision was <5.71% and the LODs were 11 pg/mL for AA‐I and 13 pg/mL for AA‐II (S/N = 3). The separation and determination of the two AAs in plasma after oral administration of C. akebiae extract were completed by the validated method.  相似文献   

17.
The applicability of hollow fiber-based liquid phase microextraction (HF-LPME) was evaluated for the extraction and preconcentration of three antidepressant drugs (amitriptyline, imipramine and sertraline) prior to their determination by HPLC-UV. The target drugs were extracted from 11.0 mL of aqueous solution with pH 12.0 (source phase) into an organic extracting solvent (n-dodecane) impregnated in the pores of a hollow fiber and finally back extracted into 24 μL of aqueous solution located inside the lumen of the hollow fiber and adjusted to pH 2.1 using 0.1 M of H3PO4 (receiving phase). The extraction was performed due to pH gradient between the inside and outside of the hollow fiber membrane. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME including pH of the source and receiving phases, the type of organic phase, ionic strength and volume of the source phase, stirring rate and extraction time were studied and optimized. Under the optimized conditions, enrichment factors up to 300 were achieved and the relative standard deviation (R.S.D.%) of the method was in the range of 2-12%. The calibration curves were obtained in the range of 5-500 μg L−1 with reasonable linearity (R2 > 0.998) and the limits of detection (LODs) ranged between 0.5 and 0.7 μg L−1 (based on S/N = 3). Finally, the applicability of the proposed method was evaluated by extraction and determination of the drugs in urine, plasma and tap water samples. The results indicated that hollow fiber microextraction method has excellent clean-up and high-preconcentration factor and can be served as a simple and sensitive method for monitoring of antidepressant drugs in the biological samples.  相似文献   

18.
应用中空纤维液相微萃取-高效液相色谱法测定水中二氯喹啉酸、特丁噻草隆、戊炔草胺等3种除草剂的残留量。样品以聚丙烯中空纤维为支撑,正辛醇萃取,以600r·min-1转速在40℃的条件下萃取20min。所得净化液以Inertsil ODS-SP C18色谱柱为分离柱,以甲醇-水(82+18)混合液为流动相,在检测波长220nm处进行测定。3种除草剂在一定的质量浓度范围内与其峰面积呈线性关系,方法的检出限(3S/N)在0.20~0.35μg·L-1之间。以地表水样为基体进行加标回收试验,所得回收率在90.6%~106%之间。方法的相对标准偏差(n=6)在3.1%~6.8%之间。  相似文献   

19.
The extractability of some typical environmental pollutants in ionic liquids (ILs) was screened by using a simple one-step liquid phase microextraction procedure. It was demonstrated that 1-alkyl-3-methylimidazolium hexafluorophosphate ([CnMIM][PF6], n = 4, 8), two typical ILs, could effectively extract a set of 45 typical environmental pollutants including BTEX (benzene, toluene, ethylbenzene, and xylene), polycyclic aromatic hydrocarbons, phthalates, phenols, aromatic amines, herbicides, organotin, and organomecury. Analytes in 10 mL sample solution held in a 15 mL vial were extracted by a 5 microL drop of ILs suspended on the needle of a high-performance liquid chromatography (HPLC) microsyringe; this was followed by HPLC, atomic absorption spectrometry, or cold-vapor atomic fluorescence spectrometry determination. The enrichment factors determined were in the range of 5-168 for 15 min extraction by [C4MIM][PF6] and 4-178 for 30 min extraction by [C8MIM][PF6], respectively, which indicates that ILs might be considered as potential environmentally benign alternative recyclable solvents for the enrichment of environmental pollutants.  相似文献   

20.
A three phase hollow fiber liquid‐phase microextraction technique combined with capillary electrophoresis was developed to quantify lamotrigine (LTG) in plasma samples. The analyte was extracted from 4.0 mL of a basic donor phase (composed of 0.5 mL of plasma and 3.5 mL of sodium phosphate solution pH 9.0) through a supported liquid membrane composed of 1‐octanol immobilized in the pores of the hollow fiber, and to an acidic acceptor phase (hydrochloric acid solution pH 4.0) placed in the lumen of the fiber. The extraction was carried out for 30 min at 500 rpm. The eletrophoretic analysis was carried out in 130 mmol/L MES buffer, pH 5.0 with a constant voltage of +15 kV and 20°C. Sample injections were performed for 10 s, at a pressure of 0.5 psi. The detection was performed at 214 nm for both LTG and the internal standard lidocaine. Under the optimized conditions, the method showed a limit of quantification of 1.0 μg/mL and was linear over the plasmatic concentration range of 1.0–20.0 μg/mL. Finally, the validated method was applied for the quantification of LTG in plasma samples of epileptic patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号