首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Mehta AC 《Talanta》1987,34(7):609-613
Procedures are described for the validation of analytical methods for the determination of drugs and metabolises in biological fluids.  相似文献   

2.
This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.  相似文献   

3.
Green tea (Camellia sinensis) contains quercetin as a bioactive compound. Quercetin has anti-inflammatory and anticancer effects. The aim of this paper was to develop and validate an RP-HPLC method for determination of quercetin in green tea simpler and faster than other available methods. RP-HPLC analysis was performed by isocratic elution with a flow rate of 1.0 mL/min. Pure methanol was used as a mobile phase, while the quantification was effected at 370 nm. The separation was performed at 35°C using a C18 column (4.6 × 250 mm, 5 μm). The results showed that the peak area response is linear within the concentration range of 10–70 μg/mL (r = 0.9986). The values of LOD and LOQ were 1.2 and 4 μg/mL, respectively. For the intra-day and intra-instrument reproducibility, RSD were in the range of 0.05–0.84% and 0.89–1.55%, respectively. The results of accuracy for the different concentrations of quercetin (40, 50 and 60 μg/mL) were 101.3, 98.4, and 98.2%. The developed and validated method was successfully applied to the determination of quercetin in green tea extract.  相似文献   

4.
A simple, rapid and sensitive analytical procedure for the measurement of imiquimod in skin samples after in vitro penetration studies has been developed and validated. In vitro penetration studies were carried out in Franz diffusion cells with porcine skin. Tape stripping technique was used to separate the stratum corneum (SC) from the viable epidermis and dermis. Imiquimod was extracted from skin samples using a 7:3 (v/v) methanol:acetate buffer (100 mM, pH 4.0) solution and ultrasonication. Imiquimod was analyzed by HPLC using C(8) column and UV detection at 242 nm. The mobile phase used was acetonitrile:acetate buffer (pH 4.0, 100 mM):diethylamine (30:69.85:0.15, v/v) with flow rate 1 mL/min. Imiquimod eluted at 4.1 min and the running time was limited to 6.0 min. The procedure was linear across the following concentration ranges: 100-2500 ng/mL for both SC and tape-stripped skin and 20-800 ng/mL for receptor solution. Intra-day and inter-day accuracy and precision values were lower than 20% at the limit of quantitation. The recovery values ranged from 80 to 100%. The method is adequate to assay imiquimod from skin samples, enabling the determination of the cutaneous penetration profile of imiquimod by in vitro studies.  相似文献   

5.
An RP-HPLC method for the determination of four phenolic compounds: gallic acid (GA), pyrogallol (PY), resorcinol (RE) and ellagic acid (EA), derived from hydrolysable tannins is reported. Separation was achieved on a SunFire C18 (250 x 4.6 mm id, 5 microm) column at 40 degrees C with gradient elution. UV detection at 280 nm was applied. The developed method was validated in terms of linearity, accuracy and precision. Satisfactory repeatability and between day precision were noticed with RSD values lower than 3%. Recoveries from different biological samples ranged from 91.50 to 105.25%. The LODs were estimated as 1.70 mg/L for PY, 1.68 mg/L for GA, 1.52 mg/L for RE and 0.98 mg/L for EA with a 20 microL injection volume. The method was applied for the determination of these compounds in oak leaves and in ruminal fluid and urine samples taken from beef cattle fed with oak leaves. The proposed method could be used in ruminant nutrition studies to verify the effect that a diet rich in tannins have on ruminal fermentation and to determine the toxicity of these compounds.  相似文献   

6.
A rapid and effective isocratic chromatographic procedure is successfully developed to determinate methotrexate (MTX) entrapment efficiency (EE) in polymeric nanocapsules using reversed-phase high-performance liquid chromatography. The method employed a RP-C(18) Shimadzu Shim-pack CLC-ODS (150 mm x 4.6 mm, 5 microm) column with mobile phase constituted by a mixture of water-acetonitrile-tetrahydrofuran (65:30:5 v/v/v; pH 3.0) at a flow rate of 0.8 mL/min. The eluate is monitored with a UV detector set at 313 nm. The parameters used in the validation process are: linearity, specificity, precision, accuracy, and limit of quantitation (LOQ). The linearity is evaluated by a calibration curve in the concentration range of 10-50 microg/mL and presented a correlation coefficient of 0.9998. The polymers (PLA or PLA-PEG), oil, and surfactants used in the nanocapsule formulation did not interfere with analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.72%. Results are satisfactory, and the method proved to be adequate for the determination of methotrexate in nanocapsules formulations.  相似文献   

7.
A validated stability-indicating HPLC method was developed for the analysis of azithromycin (AZ) and its related compounds in raw materials, capsule, and suspension using an Xterra RP C18 column at 50 degrees C with UV detection at 215 nm. Isocratic elution was employed using the mobile phase 14 mM disodium hydrogen phosphate (pH 10.5, adjusted by 1 M NaOH)-methanol-acetonitrile-tetrahydrofuran (40.0 + 30.0 + 30.0 + 0.1, v/v/v/v). AZ and 14 of its related compounds were separated and quantified. The described method was linear over the range of 2-1800 microg/mL AZ with (r = 0.9999). The stability of AZ was studied under accelerated acidic, alkaline, and oxidative conditions. The proposed method was used to investigate the kinetics of acidic and alkaline hydrolysis process of AZ at different temperatures, and the apparent pseudo first-order rate constant, half-life, and activation energy were calculated. The major peak detected from the degradation of AZ in alkaline and acidic conditions was decladinosylazithromycine, while azithromycin N-oxide was detected from the oxidative degradation. Long-term stability studies for capsule and oral suspension were carried out. The proposed stability-indicating method was completely validated according to the U.S. Food and Drug Administration requirements.  相似文献   

8.
A simple, rapid, accurate and precise RP-HPLC method was developed for the determination of stigmasterol in botanical extract of Ficus deltoidea. Separation was achieved with acetonitrile and acetic acid in water (75:25% v/v) in isocratic mode at 210?nm. Single sharp peak of standard stigmasterol was detected at retention time 3.17?min which overlay with the peak of plant extract at 3.14?min. The calibration curve was found to be linear in a concentration range of 2–10?μg/ml with correlation coefficient of 0.998. The LOD and LOQ were found to be 1.50?μg/ml and 4.55?μg/ml respectively. Accuracy and precision was determined with overall recovery of 99.6–100.1% for stigmasterol and RSD values in both intra-day and inter-day repeatability assay lesser than 0.340%, respectively. The robustness study also indicated that there is no influence of minor changes in detecting wavelength and flow rate of mobile phase on the response.  相似文献   

9.
建立了一种测定氨噻肟酸乙酯的反相高效液相色谱法 ,固定相为Hypersil ODS2 (4.6mmi.d.× 2 50mm ,5μm) ,流动相为乙腈 乙酸 水 (体积比为70∶0 .1∶30 ) ,检测波长 2 54nm。氨噻肟酸乙酯在 0 .0 1~ 60mg范围内呈现良好的线性关系 ,相对标准偏差为 2 .7% (c=0 .1mg mL ,n =6) ,回收率在 99.4 %~ 1 0 2 %之间  相似文献   

10.
The present study describes the development and subsequent validation of a stability indicating reverse-phase HPLC (RP-HPLC) method for the analysis of oseltamivir active pharmaceutical ingredient (API). The proposed RP-HPLC method utilizes Kromasil C(18), 5 microm, 250 mm x 4.6 mm i.d. column (at ambient temperature), gradient run (using acetonitrile and triethylamine as mobile phase), effluent flow rate (1.0 ml/min), and UV detection at 215 nm for analysis of oseltamivir. The described method was linear over the range of 70-130 microg/ml (r(2)=0.999). The precision, ruggedness and robustness values were also within the prescribed limits (<1% for system precision and <2% for other parameters). Oseltamivir was exposed to acidic, basic, oxidative and thermal stress conditions, and the stressed samples were analyzed by the proposed method. Chromatographic peak purity results indicated the absence of co-eluting peaks with the main peak of oseltamivir, which demonstrated the specificity of assay method for estimation of oseltamivir in presence of degradation products. The proposed method can be used for routine analysis of oseltamivir in quality control laboratories.  相似文献   

11.
A quality by design (QbD) based high-resolution HPLC method is described for determination of impurities in apixaban (APX) in the tablet dosage form. Employing a simple and stability-indicating HPLC method, nine known impurities were quantified with good peak resolution. Mobile phase A (MP-A) was prepared with buffer and acetonitrile 90:10 v/v, while mobile phase B (MP-B) contained water and acetonitrile 10:90 v/v. The gradient program was 0 min, MP-A 75%, B 25%; 20 min, MP-A 65%, B 35%; 30 min, MP-A 40%, B 60%; 40min, MP-A 40%, B 60%; 42 min, MP-A 75%, B 25%; and 50 min, MP-A 75%, B 25%. The chromatographic separation was achieved using a Zorbax RX C18 250 × 4.6 mm column, 5 μm (1.0 ml min−1, 280 nm, 50 μl) and a column temperature of 40°C. Several separation studies were carried out using design of experiments to optimize the method. Validation results confirm the applicability of the developed method for quality analysis and stability studies of the regular product on the manufacturing stream.  相似文献   

12.
A fast, feasible, isocratic, stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method has been developed and validated for the quantitative determination of marbofloxacin in marbofloxacin tablets. The method was developed using Zorbax SB C18 (150?mm?×?4.6?mm), 5-µm column thermostated at 30°C, mobile phase A (1?mL of trifluoroacetic acid in 1000?mL of water), mobile phase B (acetonitrile) in the ratio of 83:17?v/v at flow rate of 1.0?mL/min, and an injection volume of 10?µL. The analyte was monitored at a wavelength of 298?nm. The method was validated in accordance with the Food and Drug Administration (FDA) Veterinary International Conference on Harmonization guidelines. To demonstrate stability indicating ability of method, drug product was subjected to the stress condition of acidic, basic, humidity, thermal, oxidative, and photolytic degradation.  相似文献   

13.
A simple and fast method was developed using RP-HPLC for separation and quantitative determination of vanillin and related phenolic compounds in ethanolic extract of pods of Vanilla planifolia. Ten phenolic compounds, namely 4-hydroxybenzyl alcohol, vanillyl alcohol, 3,4-dihydroxybenzaldehyde, 4-hydroxybenzoic acid, vanillic acid, 4-hydroxybenzaldehyde, vanillin, p-coumaric acid, ferulic acid, and piperonal were quantitatively determined using ACN, methanol, and 0.2% acetic acid in water as a mobile phase with a gradient elution mode. The method showed good linearity, high precision, and good recovery of compounds of interest. The present method would be useful for analytical research and for routine analysis of vanilla extracts for their quality control.  相似文献   

14.
反相高效液相色谱法测定藜芦混碱中藜芦定的含量   总被引:1,自引:0,他引:1  
建立测定藜芦混碱中藜芦定的反相高效液相色谱方法.方法:采用Di-amonsil-C18色谱柱(250 mm×4.6 mm,5 μm),以甲醇-0.1 mol/L乙酸铵(60:40)为流动相,流速1.0 mL/min,检测波长220 nm;柱温30℃.藜芦定在0.96~9.6μg线形关系良好,r=0.9999,藜芦定平均加样回收率为96.4%,RSD为1.6%(n=3).试验结果表明,该方法准确、简便,重现性好.  相似文献   

15.
This paper describes the optimization and validation of an analytical methodology for the determination of losartan potassium in capsules by HPLC using 25-1 fractional factorial and Doehlert designs. This multivariate approach allows a considerable improvement in chromatographic performance using fewer experiments, without additional cost for columns or other equipment. The HPLC method utilized potassium phosphate buffer (pH 6.2; 58 mmol L−1)-acetonitrile (65:35, v/v) as the mobile phase, pumped at a flow rate of 1.0 mL min−1. An octylsilane column (100 mm × 4.6 mm i.d., 5 μm) maintained at 35 °C was used as the stationary phase. UV detection was performed at 254 nm. The method was validated according to the ICH guidelines, showing accuracy, precision (intra-day relative standard deviation (R.S.D.) and inter-day R.S.D values <2.0%), selectivity, robustness and linearity (r = 0.9998) over a concentration range from 30 to 70 mg L−1 of losartan potassium. The limits of detection and quantification were 0.114 and 0.420 mg L−1, respectively. The validated method may be used to quantify losartan potassium in capsules and to determine the stability of this drug.  相似文献   

16.
A simple, selective, sensitive, accurate, and precise method was developed for determination of metformin hydrochloride (MF) in human urine using RP-HPLC. The method depends upon using an octylsilyl (C8) 5 microm particle size column at ambient temperature with mobile phase consisting of 33 mM sodium dihydrogen phosphate containing 6.38 mM hexanesulfonic acid sodium salt and adjusted to apparent pH 3.0 with phosphoric acid-acetonitrile (93 + 7, v/v) at a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 231 nm based on peak area with a linear calibration curve over the concentration range of 0.01-50 microg/mL. The proposed method was applied to the determination of the urinary excretion pattern of MF (the cumulative amounts excreted were calculated without pretreatment of the urine sample) and for determination of the dissolution pattern of MF tablets. The proposed method was completely validated according to the U.S. Food and Drug Administration guidelines.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic method with diode array detection was established to simultaneously determine the seven bioactive lignans in Herpetospermum caudigerum, namely ent-isolariciresinol (1), dehydrodiconiferyl alcohol (2), herpetrione (3), herpetin (4), herpetetrone (5), herpetotriol (6) amd herpetal (7). The HPLC assay was performed on a Restek Pinnacle DB C18 column (250 x 4.6 mm, 5 microm) with gradient elution of acetonitrile and 0.1% phosphoric acid within 65 min. The detection wavelength was 240 nm. The flow-rate was 1.0 mL/min. All calibration curves showed good linearity (r2 > 0.9998) within test ranges. The method was reproducible with intra- and inter-day variation of less than 1.98%. The method provided good accuracy with recoveries in the range 95.19-102.64% with RSDs less than 1.52%. The method was successfully applied to the quantification of seven constituents in 15 H. caudigerum samples collected from different cities. The results indicated that the developed assay could be considered as a suitable quality control method for H. caudigerum.  相似文献   

18.
Steiner MS  Duerkop A 《The Analyst》2011,136(1):148-154
The first probe for the fluorogenic determination of acetyl phosphate (AcP), (bpy)(2)Ru(1,10-phenanthroline-5,6-dione dioxime) (RuPDO), was prepared and its reaction with AcP was studied in detail. The emission of the weakly luminescent RuPDO is red shifted and strongly enhanced upon reaction with AcP in the presence of metal cations like Zn(2+) or Cu(2+). The reaction occurs within 60 min incubation time under highly biocompatible conditions (aqueous buffer of pH 7, 37 °C). A linear dynamic range from 10 to 200 μmol L(-1) is observed with an LOD of AcP of 3.4 μmol L(-1) (for RuPDO-Zn). Other bio-phosphates studied show only weak interference. Furthermore, the applicability of the probe in complex biological matrices was evaluated.  相似文献   

19.
A simple and precise high-performance liquid chromatographic procedure has been developed for the determination of temafloxacin and its trace level metabolites in biological matrices. Plasma samples are ultrafiltered after addition of an internal standard in a displacing reagent containing sodium dodecyl sulfate and acetonitrile. Plasma ultrafiltrates or diluted urines are chromatographed on a reversed-phase analytical column, using an ion-pair chromatographic mobile phase and fluorescence detection. The chromatographic system allows resolution and quantitation of temafloxacin's oxidative metabolites, which collectively account for less than 2% of the administered dose. The mean intra-assay coefficient of variation for determination of temafloxacin concentrations in plasma ranging from 0.05 to 10.0 micrograms/ml was 0.7%. The procedure was implemented at four laboratories for the analysis of over 12,000 samples from clinical studies. Inter-assay coefficients of variation estimated from routine analyses of quality control samples in these studies averaged 4% or lower for concentrations in the 0.15-10 micrograms/ml range. The limit of quantitation of the procedure is approximately 10 ng/ml; inter-assay coefficients of variation at 15 ng/ml averaged under 9%. Calibration curves were reproducible and highly linear, with correlation coefficients typically averaging over 0.9995. An alternative, more complex procedure, involving methylene chloride extraction, which extends the detection limits to below 1 ng/ml, is also described.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号