首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Indirect chemiluminescence (ICL) detection for capillary electrophoresis (CE) of monoamines and catechol using luminol-K3 [Fe(CN)6] system was described. A strong and stable background chemiluminescence (CL) signal can be generated by luminol-K3 [Fe(CN)6] reaction. Based on the principle of that some phenolic compounds may be oxidized in the presence of K3 [Fe(CN)6], quenching effect of catecholamines for luminol-K3[Fe(CN)6] CL reaction results in a quantifiable decrease in the background signal. The conditions for CE separation and the CL detection for four standard catecholamines were systematically investigated using a homemade CE-ICL system. Under the optimum conditions, the detection limits of dopamine (DA), epinephrine (EP), norepinephrine (NE) and catechol (CA) were determined to be 0.18 mciroM 0.39 microM 0.48 microM and 0.09 microM, respectively. It also has been successfully applied to analyze seven pharmaceutical samples and seven human urine samples.  相似文献   

2.
Based on the enhancing effects of norepinephrine (NE), epinephrine (EP), dopamine (DA) and 5‐hydroxytryptamine (5‐HT) on the chemiluminescence (CL) reaction between [Ag(HIO6)2]5? and luminol in alkaline solution, a high‐performance liquid chromatography (HPLC) method with CL detection was explored for the sensitive determination of monoamine neurotransmitters for the first time. The UV–visible absorption spectra were recorded to study the enhancement mechanism of monoamine neurotransmitters on the CL of [Ag(HIO6)2]5? and luminol reaction. The HPLC separation of NE, EP, DA and 5‐HT was achieved with isocratic elution using a mixture of aqueous 0.2% phosphoric acid and methanol (5:95, v/v) within 11.0 min. Under the optimized conditions, the detection limits of NE, EP, DA, and 5‐HT were 4.8, 0.9, 1.9 and 2.3 ng/mL, respectively, corresponding to 17.6–96.0 pg for 20 μL sample injection. The recoveries of monoamine neurotransmitters in rat brain were >95.6% with the precisions expressed by RSD <5.0%. The validated HPLC‐CL method was successfully applied for the quantification of NE, EP, DA and 5‐HT in rat brain. This method has promising potential for some biological and clinical investigations focusing on the levels of monoamine neurotransmitters. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
A new method based on high‐performance liquid chromatography (HPLC) coupled with on‐line gold nanoparticle‐catalyzed luminol chemiluminescence (CL) detection was developed for the simultaneous quantitation of catecholamines in rat brain. In the present CL system, gold nanoparticles were produced by the on‐line reaction of H2O2, NaHCO3?Na2CO3 (buffer solution of luminol) and HAuCl4. Norepinephrine (NE), epinephrine (EP) and dopamine (DA) could strongly enhance the CL signal of the on‐line gold nanoparticle‐catalyzed luminol system. The UV?visible absorption spectra and transmission electron microscopy studies were carried out, and the CL enhancement mechanism was proposed. Catecholamines promoted the on‐line formation of more gold nanoparticles, which better catalyzed the luminol–H2O2 CL reaction. The good separation of NE, EP and DA was achieved with isocratic elution using a mixture of methanol and 0.2% aqueous phosphoric acid (5:95, v/v) within 8.5 min. Under the optimized conditions, the detection limits, defined as a signal‐to‐noise ratio of 3, were in the range of 1.32–1.90 ng/mL, corresponding to 26.4?38.0 pg for 20 μL sample injection. The recoveries of catecholamines added to rat brain sample were >94.6%, with the precisions <5.5%. The validated HPLC?CL method was successfully applied to determine NE and DA in rat brain without prior sample purification. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
就1993-2005年生物胺类神经递质包括多巴胺、肾上腺素、去甲肾上腺素、5-羟色胺的各种电化学检测方法的应用研究和发展方向进行了评述。引用文献58篇。  相似文献   

5.
Diao P  Yuan H  Huo F  Chen L  Xiao D  Paau MC  Choi MM 《Talanta》2011,85(3):1279-1284
A simple and sensitive method has been developed for simultaneous analysis of three catecholamines: dopamine (DA), epinephrine (EP) and norepinephrine (NE) in urine by capillary electrophoresis (CE) coupled with in-column fiber-optic light-emitting diode-induced fluorescence detection (ICFO-LED-IFD). Fluorescein isothiocyanate was used as the fluorescence tagged reagent for derivatization of DA, EP and NE. The CE conditions for separation of these catecholamines were systematically investigated. It was found that catecholamines could be more effectively separated by adding β-cyclodextin (β-CD) and acetonitrile (ACN) to a background electrolyte (BGE) of sodium borate. The migration times are 10.61, 10.83 and 11.14 min for DA, EP and NE, respectively and the catecholamines are completely separated within 11.5 min under the optimal condition of a BGE containing 10% v/v ACN, 20 mM β-CD and 20 mM sodium borate (pH 9.5), and an applied voltage of 13 kV. The relative standard deviations of migration time and peak area for these catecholamines are less than 0.16 and 2.0%, respectively. The limit of quantifications (LOQs) for DA, EP and NE are 3.5, 1.0 and 3.1 nM whereas the limit of detections (LODs) for DA, EP and NE are 1.0, 0.3 and 0.9 nM, respectively. Our proposed CE method provides low LOQ and LOD values. This CE-ICFO-LED-IFD methodology has been successfully applied to analyze catecholamines in human urine samples with good accuracy and satisfactory recovery.  相似文献   

6.
A rapid and simple method is presented for the determination of folic acid (FA) by capillary electrophoresis (CE) with chemiluminescence (CL) detection. This method was based on enhance effect of FA on the CL reaction between luminol and BrO(-) in alkaline aqueous solution. Optimal separation and determination was obtained with an electrophoretic buffer of 35 mM sodium borate (pH 9.4) containing 0.8 mM luminol, and an oxidizer solution of 1.6 mM NaBrO in 100 mM NaCO(3) buffer solution (pH 12.0). Under the optimal conditions, the determination of FA was achieved in less than 20 min, and the detection limit was 2.0 x 10(-8) M (S/N=3). The relative standard deviations (RSDs) on peak area and migration time were in the 1.5 and 1.1%, respectively. The present CE-CL method was applied to the determination of FA in commercial pharmaceutical tablets, apple juices and human urine.  相似文献   

7.
Several metallocomplexes of tetrakis-carboxyphenylporphyrin (TCPP) were separated on fused-silica capillary using CZE with UV-VIS detection. Metalloporphyrins of Co(II), Cu(II), Mn(II), Ni(II), and Zn(II) were formed directly in TCPP solution with addition of Cd(II) to increase the formation reaction rate. The composition of BGE, its concentration, and pH were optimized to ensure the stability of complexes and proper resolution. In particular, the problem of signals' shape was investigated and discussed. The presence of beta-CD in borate buffer significantly improved separation efficiency and signal shapes due to formation of inclusion complexes. Under the best separation conditions (50 mM borate running buffer at pH 9 with addition of 2 mM beta-CD, 30 kV applied voltage) a separation of metal complexes with TCPP was accomplished in 16 min.  相似文献   

8.
Wu Y  Lin JM  Su R  Qu F  Cai Z 《Talanta》2004,64(2):338-344
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The characteristics and primary performance of the home-made microchip capillary electrophoresis (MCCE) were investigated with neurotransmitters. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Separation parameters such as injection time, buffer components, pH of the buffer were studied. Relative standard deviations of not more than 6.0% were obtained for both peak currents and migration times. Under the selected separation conditions, the response for DA was linear from 5 to 200 μM and from 20 to 800 μM for CA. The limits of detection of DA and CA were 0.51 and 2.9 μM, respectively (S/N=3).  相似文献   

9.
A method based on pre-capillary derivatization with luminol (3-aminophthalhydrazide) for carbohydrate analysis using capillary electrophoresis with on-line chemiluminescence (CL) detection was developed. The derivatives of seven monosaccharides were separated and detected by using 200 mM borate buffer containing 100 mM hydrogen peroxide at pH 10.0 as separation electrolyte and 25 mM hexacyanoferrate in 3 M sodium hydroxide solution as post-capillary chemiluminescence reagent with separation efficiencies ranging from 160,000 to 231,000 plates per metre. The minimum amount of carbohydrate derivatized was 2 pmol (corresponding to the concentration of 2 microM). The method also provided a linear response for glucose in the concentration range of 0.1-250 microM with a mass detection limit of 420 amol or a concentration detection limit of 0.1 microM. Preliminary work using the CE-CL format to determine glucose in a rat brain microdialysis sample is presented as a typical case.  相似文献   

10.
Huang XJ  Pu QS  Fang ZL 《The Analyst》2001,126(3):281-284
A capillary electrophoresis (CE) system with chemiluminescence (CL) detection was combined with flow injection (FI) sample introduction on a chip platform. A falling-drop interface was applied to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A tubular reservoir at the capillary outlet served as both the CL reaction and detection cell for the luminol-peroxide-metallic ion chemiluminescent reaction, with the luminol included in the separation buffer and CL reagent H2O2 continuously introduced into the outlet reservoir. An optical fiber was positioned within the outlet reservoir directly opposite, and 300 microns away from, the capillary outlet for collecting and transferring the generated CL to the PMT. The peak height signals and the separation efficiency were almost independent of the reagent flow-rate, making the system a robust one. The performance of the system was illustrated by the separation of Co(II) and Cu(II), achieving baseline separation in 60 s. Detection limits (3 sigma) were 1.25 x 10(-8) and 2.3 x 10(-6) mol dm-3 for Co(II) and Cu(II), respectively. Peak height precision was 1.9% RSD (n = 9) at the 10(-7) mol dm-3 Co level.  相似文献   

11.
Huang Y  Zhao S  Shi M  Liu J  Liang H 《Analytica chimica acta》2011,694(1-2):162-166
A microchip electrophoresis method with laser induced fluorescence detection was developed for the immunoassay of phenobarbital. The detection was based on the competitive immunoreaction between analyte phenobarbital and fluorescein isothiocyanate (FITC) labeled phenobarbital with a limited amount of antibody. The assay was developed by varying the borate concentration, buffer pH, separation voltage, and incubation time. A running buffer system containing 35 mM borate and 15 mM sodium dodecyl sulfate (pH 9.5), and 2800 V separation voltage provided analysis conditions for a high-resolution, sensitive, and repeatable assay of phenobarbital. Free FITC-labeled phenobarbital and immunocomplex were separated within 30s. The calibration curve for phenobarbital had a detection limit of 3.4 nM and a range of 8.6-860.0 nM. The assay could be used to determine the phenobarbital plasma concentration in clinical plasma sample.  相似文献   

12.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

13.
A capillary electrophoresis method with ultraviolet (UV) detection was developed and optimized for the enantiomer separation of norepinephrine (NE), epinephrine (EP) and isoprenaline (IP) using dual cyclodextrins (CDs) of 2-hydroxypropyl-beta-CD (HP-beta-CD) and heptakis (2,6-di-o-methyl)-beta-CD (DM-beta-CD) as chiral selectors. Optimal separation was obtained using a running buffer of 50mM phosphate containing 30mM HP-beta-CD and 5mM DM-beta-CD at pH 2.90 and a field strength of 20kV in 45cmx75mum (40cm effective length) uncoated capillary. The UV absorbance detection was set at 205nm. A 0.1% (w/w) polyethylene glycol or 0.1% (v/v) acetonitrile was used to enhance the detection sensitivity. There was a wide and excellent linear calibration graph for each enantiomer in the range 1.0x10(-3) to 1.0x10(-6)M and the detection limit (S/N=3) was found from 8.5x10(-7) to 9.5x10(-7)M. The method has been applied for the determination of isoprenaline in isoprenaline hydrochloride aerosol and to the analysis of serum samples. The recoveries of NE and EP in serum and IP in drug were ranged from 90 to 110%. The relative standard deviations of all the analyte peaks were less than 2.8% for migration time and less than 4.8% for peak area.  相似文献   

14.
An assay of norepinephrine (NE), epinephrine (E), dopamine (DA), normetanephrine (NE) and metanephrine (MN) based on high-performance liquid chromatography (HPLC) in combination with atmospheric pressure chemical ionization mass spectrometry (APcI-MS) is described. The catecholamines and metanephrines were extracted from urine and aqueous samples using Bio-Rex 70 cation-exchange resin and subjected to analysis by HPLC/APcI-MS. The separation was performed on a C18 column in 50 mM ammonium formate buffer, pH 3.0, using a flow rate of 0.8 mL/min. Acetonitrile was added post-column at a flow rate of 0.2 mL/min via a post-column addition tee. The total analysis time was 6.5 min. The quantitative analysis was performed using 3,4-dihydroxybenzylamine (DHBA) as the internal standard (I.S.). Selected ion monitoring detection was applied: m/z 170 (for NE), 184 (for E and NM), 154 (for DA), 198 (for MN) and 140 (for DHBA, I.S.). The limits of quantitation were 5 ng/mL for NE, E and DA and 2.5 ng/mL for NM and MN. The recovery ranged from 75 to 83% for each analyte. The method was found to be simple and highly selective for the determination of catecholamines and metanephrines in the urine of patients suspected of pheochromocytoma.  相似文献   

15.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

16.
毕月玲  许桐  陈利琴 《色谱》2021,39(12):1306-1313
生物单胺包括儿茶酚胺类以及5-羟色胺等,在中枢神经系统中扮演着非常关键的角色,也是临床上诊断神经内分泌肿瘤疾病的重要生物标志物。由于这类单胺类物质的强化学极性导致传统吸附材料对其吸附效果不佳,从复杂生物样本中同时检测更多的生物单胺存在挑战性。该文建立了一种基于聚冠醚纳米纤维在线固相萃取检测尿液中3种儿茶酚胺(多巴胺、肾上腺素、去甲肾上腺素)和5-羟色胺的方法。采用静电纺丝法制备聚二苯并-18-冠-6醚-聚苯乙烯复合纳米纤维(PCE-PS),制成装填纤维的固相萃取(PFSPE)柱,再将PFSPE柱与HPLC进行在线联用。该在线PFSPE-HPLC方法采用双三元泵进行样品富集净化和分析,左泵连接PFSPE柱,进行样品富集净化;右泵连接分析柱进行样品分离检测。控制切换阀的切换,实现样品富集后洗脱至分析柱中分离检测。结果表明,在线PFSPE-HPLC检测尿液儿茶酚胺(多巴胺、肾上腺素、去甲肾上腺素)和5-羟色胺在1~200 ng/mL范围内有良好的线性关系,线性相关系数达0.996以上。3种儿茶酚胺和5-羟色胺的检出限(S/N=3)分别为1和2.5 ng/mL,定量限(S/N=10)分别为2.5和5 ng/mL。空白尿液和实际尿液加标回收率在83.5%~117.7%之间,日内精密度<10%。PCE-PS复合纳米纤维在多次使用后无明显变化,具有良好的稳定性,可重复使用达95次以上。在线PFSPE-HPLC方法能够集样品在线前处理与分析检测于一体,省时省力,实现分析过程的高度自动化。该方法成功应用于尿液中3种儿茶酚胺和5-羟色胺的检测,可以为临床上相关疾病检测诊断和研究提供有力的技术支持。  相似文献   

17.
Becker A  Scheuch E  Bode U  Jaehde U 《Electrophoresis》2002,23(15):2457-2464
The suitability of micellar electrokinetic chromatography (MEKC) coupled with diode array or laser-induced fluorescence (LIF) detection to analyze the four sulfur-containing excitatory amino acids (SEAA), homocysteine sulfinic acid (HCSA), homocysteic acid (HCA), cysteine sulfinic acid (CSA), and cysteic acid (CA) was investigated. 5-Carboxy-fluorescein succinimidyl ester was chosen as fluorescent reagent to derivatize HCSA, HCA, CSA, and CA. During method development, the yield of reaction dependent on pH and incubation time as well as the stability of the products were analyzed. The maximum yield was obtained after 30 min using a 0.1 M borate buffer (pH 8.9) as derivatization buffer. Each labeled amino acid exhibited high stability at room temperature over a period of 5 days. Baseline separation of labeled HCSA, HCA, CSA, and CA was obtained using a buffer consisting of 0.1 M borate, 50 mM sodium dodecyl sulfate (SDS), and 5% v/v methanol (pH 9.0). By applying LIF detection, limits of detection ranged from 0.9 x 10(-10) M for HCSA to 6.0 x 10(-10) M for CA, respectively. Slightly modified separation conditions enabled the analysis of SEAA in cerebrospinal fluid in the presence of the neurotransmitters glutamate and aspartate. In conclusion, MEKC coupled with LIF detection is a suitable technique for the simultaneous and sensitive analysis of SEAA. Further work will focus on the validation of the method with cerebrospinal fluid as sample matrix.  相似文献   

18.
吴友谊  屈锋  林金明 《中国化学》2005,23(2):155-159
An end-channel amperometric detector with a guide tube for working electrode was designed and integrated on a home-made glass microchip. The guide tube was directly patterned and fabricated at the end of the detection reservoir, which made the fixation and alignment of working electrode relatively easy. The fabrication was carried out in a two-step etching process. A 30 μm carbon fiber microdisk electrode and Pt cathode were also integrated onto the amperometric detector. The baseline separation of dopamine (DA), catechol (CA) and epinephrine (EP) was achieved within 80 s. Relative standard deviations of not more than 5.2% were obtained for both peak currents and migration times of DA and CA (n=5). Using standard adding method, DA in tLrine and plasma samples was detected. The recoveries were in the range of 83%—103%.  相似文献   

19.
In this work, an LED‐induced‐chemiluminescence (LED‐CL) system was developed to extend the application of CL detection in CE. In the LED‐CL, the analyte photooxidizes luminol under the irradiation of LEDs and generates CL. Taking the advantage of the small size nature of LEDs, the constructed photoreactor is greatly miniaturized, and especially suitable as a CE detector. The feasibility of the proposed detector was evaluated by detection of riboflavin (RF), flavin mononucleotide (FMN) and flavin adenine dinucleotide (FAD) after CE separation. Under the optimized conditions, the LODs for RF, FMN and FAD were 0.007, 0.02 and 0.1 μg/mL, respectively, better than those by UV detection. The RSDs were 3.4, 3.6 and 4.1% for 0.5 μg/mL RF, 2 μg/mL FMN and 5 μg/mL FAD, respectively. The LED‐CL detector features low cost, miniaturization, fast response, high sensitivity and good reproducibility.  相似文献   

20.
A new method for determination for catecholamines (CA) utilizing microchip technology and a thermal lens microscope has been developed. Microchannels with a 250 microm x 10 microm cross section were used for mixing, reaction, and detection. Epinephrine (EP), nor-epinephrine (NE), dopamine (DA), and L-dopa (LD) were determined by using coloring oxidization to aminochromes by sodium metaperiodate. A thermal lens microscope (TLM) was used for detection of the product. The sensitivity of the system was comparable for the four CA and required only 15 s for mixing of sample and reagent. The calibration lines indicated excellent linearity for concentrations of 5-20 microg mL(-1). The relative standard deviations for 10 microg mL(-1) solution were 1.08, 2.18, 2.2, and 2.5% for EP, NE, DA, and LD, respectively. CA in pharmaceutical injections were also determined by use of the system and the results correlated very well with nominal values. Results obtained by use of the integrated system suggested there was a sufficient possibility to realize high-throughput medical diagnosis systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号