首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Yu CZ  He YZ  Han F  Fu GN 《Journal of chromatography. A》2007,1171(1-2):133-139
A post-column reactor with coaxial-gap mode is developed for laser-induced fluorescence detection (LIF) in capillary electrophoresis (CE). The reactor can be assembled simply and conveniently, in which a thin polyimide sleeve of 10-mm length obtained from the capillary coating is used to align separation and reaction capillary with a 20 microm gap. Naphthalene-2,3-dicarboxaldehyde and 2-mercaptoethanol are used as derivatization reagents and delivered into the reaction capillary through the annulus between the separation capillary and polyimide sleeve and the gap of two capillaries by gravity. A reaction distance from the gap to detection point is 5mm. For the post-column reactor of CE-LIF, several configuration parameters are optimized, including liquid level difference between the derivatization solution and outlet buffer, annular dimension between the outer diameter of etched separation capillary and the inner diameter of polyimide sleeve, and reaction distance, etc. The detection limits in the range from 8.0x10(-8) to 1.0x10(-6) mol/L and linear calibration range more than two orders of magnitude are obtained for amino acids. The separation efficiency ranges from 1.35x10(5) to 1.67x10(5) theoretical plates.  相似文献   

2.
高效凝胶过滤色谱法分离测定豆薯种子蛋白   总被引:5,自引:1,他引:5  
吴红京  郝冰  唐根源  林玉娟 《色谱》1997,15(2):153-155
用高效凝胶蛋白往分离豆薯种子蛋白租提液,结合光电二极管阵列检测器对分离的蛋白峰进行紫外光谱扫描来确认蛋白的纯度,测定了3种蛋白的分子量,采用邻苯二甲醛(OPA)柱后衍生法测定了豆薯种子蛋白的氨基酸含量。  相似文献   

3.
Capillary polyacrylamide gel electrophoresis separation of dideoxycytidine chain-terminated DNA fragments is reported. A post-column laser-induced fluorescence detector based on the sheath flow cuvette was used to minimize background signals due to light scatter from the gel and capillary. A preliminary mass detection limit of 10(-20) mol of fluorescein-labeled DNA fragments was obtained. The system was used to analyze an actual DNA sequencing sample. Theoretical plate counts of 2 x 10(6) were produced. Gel stability limits the performance of the current system.  相似文献   

4.
Huang Y  Duan J  Chen Q  Chen G 《Electrophoresis》2004,25(7-8):1051-1057
Eight enkephalin-related peptides were derivatized using fluorescein isothiocyanate (FITC), and the derivatization products were separated and detected by capillary electrophoresis with laser-induced fluorescence detection. The optimum molar ratio of FITC and peptide for derivatization was found to be 40:1, and 5 mmol/L sodium borate buffer (pH 9.2) was selected as derivatization media in order to get the high efficiency. Enkephalin-related peptides were completely separated in the pH range of 10.51-10.60 in a running buffer consisting of 100 mmol/L sodium borate and 60 mmol/L sodium dodecyl sulfate (SDS). The detection limit for these eight enkephalins ranged from 0.18 to 2.25 nmol/L, and the linear response range was 1.0 x 10(-6) to 1.0 x 10(-9) mol/L with correlation coefficients between 0.9947-0.9988. A separation efficiency as high as 380000 theoretical plates could be obtained for these analytes.  相似文献   

5.
高效液相色谱法测定南瓜粉中的4-氨基丁酸   总被引:15,自引:0,他引:15  
刘惠文 《色谱》2001,19(6):532-533
 采用强阳离子交换柱分离 ,pH梯度洗脱 ,邻苯二甲醛 (OPA)柱后衍生 ,荧光λex=338nm ,λem=42 5nm检测的高效液相色谱法测定了南瓜粉中的 4 氨基丁酸 (GABA)。若以GABA的峰高Y(μV)对进样质量X(μg)进行线性回归 ,则线性方程为Y =45 6 6X +1396 ,r =0 9998;GABA的平均回收率 (n =3)为 99%。方法稳定、快速、灵敏、准确。  相似文献   

6.
On-line automation of two different liquid chromatographic procedures, a pre-column derivatization system and a pre- and post-column system, in order to generate chemiluminescence is reported. Dansyl chloride (Dns-Cl) was used as a pre-column reagent to form fluorophores and bis(2,4,6-trichlorophenyl) oxalate (TCPO) and hydrogen peroxide (H2O2) as a post-column reagent to generate chemiluminescence. This procedure is based on the employment of a primary column packed with C18 material inserted in a multi-dimensional assembly for sample clean-up and derivatization with Dns-Cl. The dansyl derivatives formed are transferred and separated in a LiChrospher 100 RP18 analytical column (125 x 4 mm id, 5 microns film thickness) using acetonitrile-imidazole buffer (pH 6.8) (70 + 30) as eluent. The separated derivatives were transferred to the detector for fluorescence detection or to the post-column system where the chemiluminescence response was generated by using TCPO-H2O2 and the products were detected by chemiluminescence. The procedure was optimised for amphetamine and related compounds. A comparison between the on-line pre-column and pre- and post-column systems was performed. The results show that the sensitivity of chemiluminescence detection can be higher than that of fluorescence detection. The recoveries obtained ranged from 98 +/- 8 up to 108 +/- 8% for amphetamine and methamphetamine, respectively. The accuracy and precision of these methods were evaluated.  相似文献   

7.
Ye M  Hu S  Schoenherr RM  Dovichi NJ 《Electrophoresis》2004,25(9):1319-1326
A nanoliter enzyme microreactor was developed for on-line capillary electrophoresis (CE) peptide mapping of proteins, allowing picomole quantities of proteins to be digested. The enzyme microreactor was formed by immobilizing trypsin onto a monolithic capillary column, which was prepared by in situ polymerization of glycidyl methacrylate and ethylene dimethacrylate in a capillary. Highly efficient digestion of three protein standards was demonstrated. The detection of peptide fragments in CE was enhanced by post-column derivatization and laser-induced fluorescence detection. The microreactor has a volume of about 30 nL and is coupled with a separation capillary via a fluid joint for on-line digestion. The overall analysis, including digestion and separation, lasted only about 16 min. Column efficiencies > 300 000 plates/m were obtained for most peaks in the electropherogram of an on-line peptide mapping experiment of denatured alpha-lactalbumin under optimal conditions.  相似文献   

8.
A rapid and sensitive method was developed for the simultaneous determination of histamine and histidine by capillary zone electrophoresis with lamp-induced fluorescence detection. A fluoregenic derivatization reagent, naphthalene-2,3-dicarboxaldehyde (NDA) was successfully applied to label the histamine and histidine respectively. The derivatization conditions and separation parameters including pH and concentration of electrolyte and sample injection were optimized in detail. The optimal derivatization reaction was performed with 1.0 mM NDA, 20 mM NaCN, and 20 mM borate buffer, pH 9.1 for 15 min. The separation of NDA-tagged histamine and histidine could be achieved in less than 200 s with 40 mM phosphate buffer (pH 5.8) as the running buffer. The detection limits for histamine and histidine were 5.5 x 10(-9) and 3.8 x 10(-9) M, respectively (S/N = 3). The relative standard derivations for migration time and peak height of derivatives were less than 1.5 and 5.0%, respectively. The method was successfully applied to the analysis of histamine and histidine in the P815 mastocytoma cells and the beer samples.  相似文献   

9.
刘惠文 《色谱》1999,17(4):410-412
使用强阳离子交换柱分离、pH梯度洗脱、柱后衍生、荧光λex=338nm和λem=425nm检测的高效液相色谱法,成功地分析了药用植物铃兰中的吖丁啶-2-羧酸,方法回收率为96.4%。  相似文献   

10.
With a new oxidant for post-column chemical derivation, a novel approach was developed for the determination of Malachite Green (MG) and Leucomalachite Green (LMG) in fish by high-performance liquid chromatography (HPLC). A C(8) column was used for separation, and elution was performed with a pH 2.5 phosphate buffer (0.02molL(-1)) containing 40% acetonitrile. When the eluate was combined with 3.0x10(-4)molL(-1) iodine solution, LMG was converted to MG and detected at 618nm after post-column derivatization. The recoveries of MG and LMG were ranged from 67.3% to 73.9% and 84.7% to 92.1%, respectively, which were obtained by measuring the amount of MG and LMG in the samples with solvent calibration curve. The decision limit (CCalpha) and the detection capability (CCbeta) obtained for MG and LMG were in the range of 0.10-0.17 and 0.13-0.23mugkg(-1) in grass carp, shrimp and shellfish. This method appeared suitable for the control of MG and LMG residues in aquatic products.  相似文献   

11.
Becker A  Scheuch E  Bode U  Jaehde U 《Electrophoresis》2002,23(15):2457-2464
The suitability of micellar electrokinetic chromatography (MEKC) coupled with diode array or laser-induced fluorescence (LIF) detection to analyze the four sulfur-containing excitatory amino acids (SEAA), homocysteine sulfinic acid (HCSA), homocysteic acid (HCA), cysteine sulfinic acid (CSA), and cysteic acid (CA) was investigated. 5-Carboxy-fluorescein succinimidyl ester was chosen as fluorescent reagent to derivatize HCSA, HCA, CSA, and CA. During method development, the yield of reaction dependent on pH and incubation time as well as the stability of the products were analyzed. The maximum yield was obtained after 30 min using a 0.1 M borate buffer (pH 8.9) as derivatization buffer. Each labeled amino acid exhibited high stability at room temperature over a period of 5 days. Baseline separation of labeled HCSA, HCA, CSA, and CA was obtained using a buffer consisting of 0.1 M borate, 50 mM sodium dodecyl sulfate (SDS), and 5% v/v methanol (pH 9.0). By applying LIF detection, limits of detection ranged from 0.9 x 10(-10) M for HCSA to 6.0 x 10(-10) M for CA, respectively. Slightly modified separation conditions enabled the analysis of SEAA in cerebrospinal fluid in the presence of the neurotransmitters glutamate and aspartate. In conclusion, MEKC coupled with LIF detection is a suitable technique for the simultaneous and sensitive analysis of SEAA. Further work will focus on the validation of the method with cerebrospinal fluid as sample matrix.  相似文献   

12.
建立了邻苯二甲醛(OPA)柱后衍生-高效液相色谱测定玉米中伏马菌素B1和B2(FB1和FB2)的方法。采用ZORBAX SB-C18色谱柱,以0.1 mol/L磷酸二氢钠溶液(pH 3.3)-甲醇为流动相,梯度洗脱。流动相流速为0.8 mL/min,柱温40 ℃;衍生剂的流速为0.4 mL/min,衍生温度为室温。实验对衍生剂缓冲液的pH、衍生剂的浓度和流速、激发和发射波长等重要条件进行了优化。结果表明,衍生剂的pH在10.5、OPA的质量浓度为2 g/L、流速为0.4 mL/min、激发波长335 nm、发射波长440 nm时测定效果良好,FB1、FB2在0.2~20 mg/L范围内线性关系良好,相关系数大于0.999; FB1和FB2的检出限均为0.02 mg/kg;在0.1~ 4.0 mg/kg范围内,3个添加水平的平均回收率为82.5%~89.8%。该方法精确、简单、快速,适合玉米中FB1和FB2的测定。  相似文献   

13.
It was demonstrated that a separation of 20 amino acids constituting a protein and three phosphoamino acids that mostly frequently occur in eukaryotes was achieved within 15 min by capillary electrophoresis coupled with lamp-induced fluorescence detection. Fluorescein isothiocyanate was employed as the fluorescence label to facilitate the fluorescence detection of the 23 amino acid species. The fluorescent derivatization conditions and separation parameters including concentration of electrolyte, surfactant in buffer, applied voltage and sample injection were investigated in detail and optimized. The influence of buffer additives such as methanol, acetone and polyvinylpyrrolidone on separation selectivity and sensitivity were discussed. We showed that addition of 2% polyvinylpyrrolidone into the running buffer could dramatically enhance the separation selectivity of amino acids at the expense of a decrease of sensitivity of phosphoamino acids. Under the optimized conditions, the detection limits (S/N=2) ranged from 1.90 x 10(-8) M to 5.66 x 10(-8) M with an average efficiency of 620,000/m. The method was applied to characterization of the phosphorylation of a novel protein kinase RCaMBP (calcium/calmodulin-binding protein kinase) encoded by a cDNA newly isolated and cloned from rice. We verified that RCaMBP belonged to a type of Ser/Thr kinase, providing insight into its function in signal transduction.  相似文献   

14.
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein, a new synthesized fluorescent reagent, was established for the first time as a label for the sensitive analysis of catecholamines (CAs) and serotonin (5-HT) by micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection. After careful study on the derivatization conditions such as pH value, reagent concentration, temperature and reaction time, the labeling reaction was accomplished as quickly as 7 min with stable yield. The separation parameters for the CAs and 5-HT were also optimized in detail. The derivatives were baseline separated in a running buffer containing 30 mM boric acid and 15 mM sodium dodeculsulfate at pH 9.0. The detection limits ranged from 5 x 10(-10) to 2 x 10(-9) M (signal-to-noise ratio = 3). The rapid and sensitive method was also applied to the determination of the CAs and 5-HT of urine samples.  相似文献   

15.
《Analytical letters》2012,45(10):1821-1834
In this study 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) is proposed as a post-column derivatization (PCD) reagent for the fluorescence detection of aliphatic primary and secondary amines after HPLC separation. Five primary (methylamine, isoamylamine, 2-phenylethylamine, putrescine, and histamine) and one secondary amine (dimethylamine) were separated isocratically on a cation-exchange column using HNO3 (5 × 10?3 mol L?1) as the mobile phase. Post-column derivatization was based on two steps: 1) the derivatization of amines with NBD-Cl in alkaline medium, and 2) the acidification of the resulted mixture in order to minimize the background signal of the reagent and improve dramatically the sensitivity and determination range. The variables of the post-column reaction (concentration of NBD-Cl, buffer concentration and pH, reaction temperature, concentration of HCl, flow rates of the reagents) were thoroughly investigated. Critical chromatographic parameters such as the concentration of HNO3, the percentage of organic solvent, and the column temperature were also examined to achieve adequate separation. An internal standard of 1,7-diaminoheptane was used. The developed post-column method provides the ability for a fully automated analysis, low detection limits (LODs 20–100 µg L?1 with S/N = 3), and it requires less sample preparation. The applicability of the proposed analytical scheme was demonstrated by the determination of histamine (HIS) in tuna fish tissues according to US Food and Drug Administration (FDA) guidelines.  相似文献   

16.
A sensitive and selective analytical method was developed for the quantitative determination of fumonisins B(1) and B(2) in maize-based foods for direct human consumption. The method, based on high-performance liquid chromatography and fluorescence detection, presents a rapid and automated on-line post-column derivatization, performed with o-phtalaldehyde and N,N-dimethyl-2-mercaptoethylamine. Several factors affecting the separation and detection of fumonisins were investigated, including mobile phase composition, column features, derivatization agent flow-rate and both the excitation and the emission wavelengths. Optimal fluorescence detection was obtained by using a lambda(exc) of 343 nm and a lambda(em) of 445 nm. Under the optimized experimental conditions, a complete separation of fumonisins was obtained in less than 13 min by using a C(18) column and a gradient elution at 0.8 mL/min with methanol and 0.1M phosphate buffer at pH 3.15. The limits of detection for FB(1) and FB(2) were 4 and 5 microg/L corresponding to 5 and 6 microg/kg in matrix. Each fumonisin was determined in the range 40-320 microg/L that correspond to 50-400 microg/kg in matrix. The necessary requirements for accuracy, reproducibility and sensitivity were fulfilled and recovery values ranged from 87 to 94% for FB(1) and from 70 to 75% for FB(2) in cornflake samples at three fortification levels in the range 100-300 microg/kg. The potential of this method, combined with a simple clean-up procedure, was assessed by the measurements of FB(1) and FB(2) in maize-based products, such as maize flour, "polenta", tortillas and cookies.  相似文献   

17.
A fast, specific and sensitive high-performance liquid chromatographic procedure for the determination of cefatrizine, an orally active cephalosporin, in serum and urine is proposed. The drug is determined by the internal standard method, using cephradine as the internal standard. The separation is carried out on a reversed-phase column, filled with octadecylsilane chemically bonded microparticles. The eluent is a mixture of acetonitrile with 0.025 M sodium phosphate buffer (pH 7). Quantitation is effected by fluorescence detection of the fluorophores formed after post-column derivatization with fluorescamine in a packed-bed reactor. The chromatographic conditions and the conditions for the post-column derivatization are discussed. The method has been applied to serum and urine samples, which were analysed after deproteinization with trichloroacetic acid and injection of the clear supernatant. The accuracy and reproducibility of the procedure were investigated by the determination of the cefatrizine content in spiked serum and urine samples.  相似文献   

18.
A fluorescent post-column reaction detection scheme has been devised for selective determination of thiols. The post-column reagent is 40 microM Cd2+ and 100 microM 8-hydroxyquinoline-5-sulfonic acid (HQS) in non-complexing buffer at pH 10. HQS complexes Cd2+ to form a fluorescent product. Thiols in the HPLC effluent compete for complexation of the Cd2+, resulting in a decrease in the fluorescence response. Detection limits of 0.2 microM (0.04 ppm) are achieved for cysteine, homocysteine and glutathione in a 5 min separation. Recoveries from spiked synthetic urine samples are 87-120%.  相似文献   

19.
A rapid on-column DNA labeling technique is used to detect viral restriction DNA fragments by capillary electrophoresis-laser induced fluorescence detection. Intercalating dyes such as POPO3 or ethidium homodimer-2 are incorporated into the detection buffer. The cationic dyes migrate into the capillary during electrophoresis and bind to the oppositely migrating DNA fragments. A post-column sheath-flow fluorescence detector is used in the experiment. Excellent labeling efficiency is achieved at minimal background fluorescence by diluting the dyes to between 1 x 10(-7) M and 5 x 10(-7) M in a buffer with low ionic strength relative to the running buffer within the capillary. This dilute sheath-flow buffer allows stacking of dye molecules inside the capillary when an electric field is applied. Calibration curves using a series of DNA size markers (between 72 and 1353 base pairs) were linear over an order of magnitude in DNA concentration. Sensitivity also increased linearly with fragment length, and detection limits ranged from 4 x 10(-14) M to 5 x 10(-13) M for the size-standards. Analysis of cloned viral DNA using duck hepatitis B virus demonstrated a concentration detection limit of 3.9 x 10(-16) M. Last, the technique produced very high separation efficiency, 14 x 10(6) theoretical plates which is greater than 47 x 10(6) plates m-1, for the duck hepatitis B viral genome.  相似文献   

20.
Abstract

A rapid and specific reversed-phase ion-pairing high performance liquid chromatographic procedure for putrescine, spermidine and spermine is reported. The ion-pairing reagent, heptanesulfonate, was employed and o-phthalaldehyde and 2-mercaptoethanol were used for on-line post-column derivatization and subsequent fluorescence detection. Experiments were carried out to determine the effects of several variables such as pH, concentration of the aqueous buffer, counter-ion concentration, and the percentage of organic modifier in the moving phase. The minimum detection limits for the polyamines ranged from 120 pmoles for spermine to 12 pmoles for putrescine. The method includes a gradient program which provides complete separation from amino acids and specificity for the three polyamines. The procedure was applied successfully to urine and serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号