首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In this research, a novel stacking capillary electrophoresis method, repetitive large volume sample injection and sweeping MEKC (rLVSI-sweeping MEKC) were developed to analyze the presence of three androgenic steroids considered as sport doping drugs, testosterone (T), epitestosterone (E) and epitestosterone glucuronide (EG) in urine. This method provides better sensitivity enhancement than the traditional large volume sample stacking-sweeping strategies due to sensitivity enhancement by repetitive injections. This multiple sampling method enhances sensitivity of monitoring of urine samples by UV detection (254 nm). Firstly, the phosphate buffer was filled into an uncoated fused silica capillary and the samples were injected into the capillary at 10 psi for 20 s, and then stacked at −10 kV for 1 min using phosphate buffer containing SDS. The above injecting and stacking steps were repeated five times. Finally, separation was performed at −20 kV, using phosphate buffer containing methanol, SDS and (2-hydroxypropyl)-β-cyclodextrin. Method validation showed that calibration plots were linear (r ≧ 0.997) over a range of 5-200 ng mL−1 for T, 20-200 ng mL−1 for E and 0.5-500 ng mL−1 for EG. The limits of detection were 1.0 ng mL−1 for T, 5.0 ng mL−1 for E and 200.0 pg mL−1 for EG. When evaluating precision and accuracy, values of RSD and RE in intra-day (n = 3) and inter-day (n = 5) analysis were found to be less than 10.0%. Compared with the simple LVSS-sweeping, which is also a stacking strategy, this method further improves sensitivity up to 25 folds (∼2500 folds with MEKC without preconcentration). This method was applied to monitor 10 athletes’ urine, and did not detect any analyte. The novel stacking method was feasible for monitoring of doping by sportsmen.  相似文献   

2.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma.  相似文献   

3.
Ping Tong  Lan Zhang  Yu He  Jintian Cheng 《Talanta》2010,82(4):1101-1106
In this paper, a rapid and effective method based on capillary zone electrophoresis (CZE) coupled with electrospray ionization mass spectrometry (ESI-MS) was established for the trace analysis of microcystin (MC) isomers in crude algae sample. The experimental conditions including the composition, acidity and concentration of buffer, separation voltage, injection time, and MS detection parameters were investigated in detail. A capillary separation system was as follows: a uncoated fused-silica capillary tube (50 μm i.d. × 90 cm), 40 mmol L−1 ammonium acetate solution (pH 9.86) as running buffer, 25 kV as separation voltage, 20 kV × 3 s water first and 20 kV × 20 s for sample injection. Mass analysis was performed in ESI source, with sheath gas temperature 150 °C, sheath gas pressure 10 psi, and sheath gas flow 6 L min−1. And sheath liquid was 7.5 mmol L−1 acetic acid in 50% isopropanol-water (3 μL min−1). Protonation and ammonium adduct molecular ions m/z 506.9 (MC-LR) and 532.0 (MC-YR) were used for the quantification of MCs. Under these conditions, two MCs were baseline separated within 9 min, the calibration curves were obtained in the range of 0.11-10.0 μg mL−1 and 0.16-10.5 μg mL−1 for MC-LR and MC-YR, respectively. Meanwhile, limits of detection were 0.05 and 0.08 μg mL−1 for MC-LR and MC-YR, respectively. The recoveries for the two MCs were in the range of 95.8-108%. The developed approach had been successfully applied to the analysis of MCs in crude algae samples.  相似文献   

4.
An amperometric immunoassay for the determination of tumor necrosis factor alpha (TNFα) protein biomarker in human serum based on the use of magnetic microbeads (MBs) and disposable screen-printed carbon electrodes (SPCEs) has been developed. The specifically modified microbeads were magnetically captured on the working electrode surface and the amperometric responses were measured at −0.20 V (vs. Ag pseudo-reference electrode), upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. After a thorough optimization of the assay, extremely low limits of detection were achieved: 2.0 pg mL−1 (36 fM) and 5.8 pg mL−1 (105 fM) for standard solutions and spiked human serum, respectively. The simplicity, robustness and this clinically interesting LOD proved the developed TNFα immunoassay as a good contender for real clinical application.  相似文献   

5.
A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2 h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20 V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0 ng mL−1 Ara h 1, a detection limit of 6.3 ng mL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.  相似文献   

6.
An ionic liquid-based single-drop microextraction (IL-SDME) procedure using IL as an extractant on-line coupled to capillary electrophoresis (CE) is proposed. The method is capable of quantifying trace amounts of phenols in environmental water samples. For the SDME of three phenols, a 2.40 nL IL microdrop was exposed for 10 min to the aqueous sample and then was directly injected into the capillary column for analysis. Extraction parameters such as the extraction time, the IL single-drop volume, pH of the sample solution, ionic strength, volume of the sample solution and the extraction temperature were systematically investigated. Detection limits to three phenols were less than 0.05 μg mL−1, and their calibration curves were all linear (R2 ≥ 0.9994) in the range from 0.05 to 50 μg mL−1. And enrichment factors for three phenols were 156, 107 and 257 without agitation, respectively. This method was then utilized to analyze two real environmental samples from Yellow River and tap water, obtaining satisfactory results. Compared with the usual SDME for CE, IL-SDME–CE is a simple, low-cost, fast and environmentally friendly preconcentration technique.  相似文献   

7.
Yanyan Lu  Zhi Xing  Po Cao  Xinrong Zhang 《Talanta》2009,78(3):869-1801
A sandwich-type immunoassay linked with inductively coupled plasma mass spectrometry (ICP-MS) has been developed for the detection of anti-erythropoietin antibodies (anti-EPO Abs). Recombinant human erythropoietin (rhEPO) was immobilized on the solid phase to capture anti-rhEPO Abs specifically. After the immunoreactions with Au-labeled goat-anti-rabbit IgG, a diluted HNO3 (2%) was used to dissociate Au nanoparticles which was then introduced to the ICP-MS for measurements. Under the optimized conditions, the calibration graph for anti-EPO Abs was linear in the range of 35.6-500 ng mL−1 with a detection limit of 10.7 ng mL−1 (3σ, n = 9). The relative standard deviation (R.S.D.) for three replicate measurements of 30.9 ng mL−1 of anti-EPO Abs was 8.43%. The recoveries of anti-EPO Abs in sera at the spiking level of 50, 100, 150, 200 and 400 ng mL−1 were 99.2%, 101.5%, 95.0%, 94.0% and 102.9%, respectively. For the real sample analysis, 26 samples from healthy people and 53 samples from patients with rhEPO treatments were studied. One sample from patients showed significantly higher anti-EPO Abs from other samples, indicating a possibility of immune response of this patient.  相似文献   

8.
Microemulsion electrokinetic capillary chromatography (MEEKC) with sample stacking induced by reverse migrating pseudostationary phase (SRMP) technique in a suppressed electro-osmotic flow (EOF) strategy was investigated for analysing the new ultra-short hypnotic HIE-124 in mice serum. The proposed method utilized fused-silica capillary with a total length of 50 cm (effective length 40 cm), applied voltages for stacking and separation were 5.0 kV for 4.30 min and subsequently 25 kV, respectively, with a sample injection of 0.5 psi for 90 s. All the runs were carried out at 25 °C and detected at 213 nm. The optimum microemulsion background electrolyte (BGE) solution consisted of 0.8% (v/v) ethyl acetate, 6.6% (v/v) butan-2-ol, 1.0% (v/v) acetonitrile, 2.0% (w/v) sodium dodecyl sulfate (SDS), and 89.6 mL with 25 mM phosphate buffer pH 8. When this preconcentration technique was used, the sample stacking and the separation processes took place successively with changing the voltage with an intermediate polarity switching step. The proposed method was validated carefully with respect to high specificity of the method, good linearity (r = 0.9994), fair wide linear concentration range (66-1500 ng mL−1), limit of detection and quantitation were 21.6 and 65.5 ng mL−1, respectively. The mean relative standard deviation (RSD) of the results of intra- and inter-day precision and accuracy were less than 6.0%, and overall recovery higher than 95% of HIE-124 in mice serum. The developed method could be used for the trace analyses of HIE-124 in serum and was finally used for the pharmacokinetic study investigation of HIE-124 in mice serum.  相似文献   

9.
A simple, rapid, and highly sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) and disposable screen-printed electrodes (SPE) has been developed to detect polychlorinated biphenyls (PCBs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PCB-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PCB (HRP-PCB). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreactions among PCB-antibody-coated MBs, PCB analyte, and HRP-PCB. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing o-aminophenol and hydrogen peroxide for electrochemical detection. The different parameters, including the amount of HRP-PCB conjugates, immunoreaction time, and the concentration of substrate that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 10 pg mL−1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical immunoassay was successfully evaluated with untreated river water spiked with PCBs, and the results were validated by commercial PCB enzyme-linked immunosorbent assay kit, indicating that this convenient and sensitive technique offers great promise for decentralized environmental application and trace PCBs monitoring.  相似文献   

10.
To address people's concerns of exogenous oxytocin (OT) administration to lactating bovines, a study was undertaken to (a) establish an enzyme immunoassay (EIA) for OT determination in milk, (b) quantify OT in milk of cows administered OT, and (c) study influence of pasteurization on OT stability in milk. A sensitive EIA validated according to the criteria of European Union—Decision 2002/657/EC was developed for OT in skim milk in an analytical range of 10-250 pg mL−1 with a decision limit (CCα) of 30 pg mL−1 and detection capability (CCβ) of 41.5 pg mL−1. Milk samples collected from cows (n = 38) administered either 25 or 50 IU OT prior to milking were investigated for the presence of OT. There was no significant difference among both groups with the mean concentrations of OT being 15.8 and 14.9 pg mL−1 for cows subjected to 25 and 50 IU OT administration, respectively. The OT levels in skim milk of control cows (n = 30; untreated) were basal (around 10 pg mL−1). All the analyzed milk samples were below the CCα value of 30 pg mL−1. Pasteurization of OT spiked milk samples at different temperature and sample holding conditions reduced the immunological activity of OT to 43% at 110 °C. However, no further decline occurred in the immunological activity with increased pasteurization temperature and time. It was concluded that the milk OT concentrations after OT administrations were minimal and below the assay decision limit. However, OT was quite stable to pasteurization in OT spiked milk.  相似文献   

11.
Fong BM  Tam S  Tsui SH  Leung KS 《Talanta》2011,83(3):1030-1036
A sensitive analytical method for the determination of tetrodotoxin (TTX) in urine and plasma matrices was developed using double solid phase extraction (C18 and hydrophilic interaction liquid chromatography) and subsequent analysis by HPLC coupled with tandem mass spectrometry. The double SPE sample cleanup efficiently reduced matrix and ion suppression effects. Together with the use of ion pair reagent in the mobile phase, isocratic elution became possible which enabled a shorter analysis time of 5.5 min per sample. The assay results were linear up to 500 ng mL−1 for urine and 20 ng mL−1 for plasma. The limit of detection and limit of quantification were 0.13 ng mL−1 and 2.5 ng mL−1, respectively, for both biological matrices. Recoveries were in the range of 75-81%. To eliminate the effect of dehydration and variations in urinary output, urinary creatinine-adjustment was made. TTX was quantified in eight urine samples and seven plasma samples from eight patients suspected of having TTX poisoning. TTX was detected in all urine samples, with concentrations ranging from 17.6 to 460.5 ng mL−1, but was not detected in any of the plasma samples. The creatinine-adjusted TTX concentration in urine (ranging from 7.4 to 41.1 ng μmol−1 creatinine) correlated well with the degree of poisoning as observed from clinical symptoms.  相似文献   

12.
The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10 min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78 ng mL−1 and the CCβ to be 1 ng mL−1. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC–MS/MS showed a high correlation (R2 = 0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1 ng mL−1, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1 ng mL−1. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1 μg L−1. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.  相似文献   

13.
A novel sample preparation method, vial wall sorptive extraction (VWSE), which uses a vial whose internal wall is coated with polydimethylsiloxane (PDMS), was developed. The method was applied to the determination of progesterone in human serum sample. Human serum sample (0.5 mL) spiked with progesterone-13C2 was pipetted into the VWSE device and vortex mixing was performed for 30 min. Then, the serum sample was removed and the vial rinsed with purified water. Fifty microliter of methanol as liquid desorption (LD) solvent was pipetted into the VWSE device and vortex mixing was performed for 10 min. Then, the extract was analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The correlation coefficient (r) of the calibration curve over the concentration range of 0.5–200 ng mL−1 was 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.1 and 0.5 ng mL−1, respectively. The relative recoveries were 97.9% (RSD: 4.4%, n = 6) and 102.8% (RSD: 1.1%, n = 6) for progesterone spiked at 5 and 50 ng mL−1, respectively. This simple, accurate, sensitive, and selective analytical method is applicable to the trace analysis of a minute amount of sample.  相似文献   

14.
A new doping control screening method for the analysis of diuretics and stimulants using ultra high pressure liquid chromatography–high resolution Orbitrap mass spectrometry has been developed. The screening was performed in full scan MS with scan-to-scan polarity switching which allowed to detect more than 120 target analytes. Sample preparation was limited to 10-fold dilution of the urine into the internal standard solution followed by injection. Total run time per sample was 10 min. Validation of the method yielded detection limits for diuretics between 25 and 250 ng mL−1 and for stimulants between 5 and 500 ng mL−1. The screening method has been implemented in routine doping control.  相似文献   

15.
In this paper, four organic acids constituents of Plateau alfalfa roots have been identified and detected by a novel capillary electrophoresis (CE) strategy which combined chitosan (CS) trapping and cetyltrimethyl ammonium bromide (CTAB) assisted sample stacking. Under the optimized condition, organic acids, i.e., aconitic acid, gallic acid, citric acid and l-malic acid were concentrated and separated within 3 min. Validation parameters of this method (such as detection limits, linearity and precision) were also investigated and the limit of detection (LOD) was 2.41-53.9 ng mL−1. Linearity was obtained over the magnitude range of 5-4000 ng mL−1 approximately for different organic acids and 3 × 102-1.5 × 104 folds enrichment was achieved. The method has been applied to the determination of organic acids in roots of normal grown Plateau alfalfa and stressing affected Plateau alfalfa. Satisfactory results and recoveries were obtained in the analysis without costly and complicated sample pretreatment.  相似文献   

16.
A novel photonic suspension array was developed for multiplex immunoassay. The carries of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers are the characteristic reflection peak originated from their structural periodicity, and therefore they do not suffer from fading, bleaching, quenching, and chemical instability. In addition, because no dyes or materials related with fluorescence are included, the fluorescence background of SCCBs is very low. With a sandwich format, the proposed suspension array was used for simultaneous multiplex detection of tumor markers in one test tube. The results showed that the four tumor markers, α-fetoprotein (AFP), carcinoembryonic antigen (CEA), carcinoma antigen 125 (CA 125) and carcinoma antigen 19-9 (CA 19-9) could be assayed in the ranges of 1.0-500 ng mL−1, 1.0-500 ng mL−1, 1.0-500 U mL−1 and 3.0-500 U mL−1 with limits of detection of 0.68 ng mL−1, 0.95 ng mL−1, 0.99 U mL−1 and 2.30 U mL−1 at 3σ, respectively. The proposed array showed acceptable accuracy, detection reproducibility, storage stability and the results obtained were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. This technique provides a new strategy for low cost, automated, and simultaneous multiplex immunoassay.  相似文献   

17.
A rapid immunoassay for sensitive detection of microcystin-LR using a portable chemiluminescence multichannel immunosensor (CL-MADAG) was developed. The sensor device is based on a capillary ELISA technique in combination with a miniaturized fluidics system and uses chemiluminescence as the detection principle. Minimum concentrations of at least 0.2 μg L−1 microcystin-LR could be unambiguously measured in a spiked buffer system as well as in spiked real water samples. A single sample analysis for detection of microcystin-LR could be accomplished in just 13 min on the CL-MADAG. Besides providing a highly reproducible, fast and easy to perform test format, one major advantage of the newly established capillary immunoassay is represented by the feasibility of an internal retrospective quality control mechanism. Finally, simultaneous CL-MADAG measurements employing our inhibition immunoassay and a sandwich ELISA could be successfully demonstrated.  相似文献   

18.
For the detection of the major active component of cannabis, Δ9-tetrahydrocannabinol (THC) in aqueous samples, a homogeneous competitive immunoassay based on fluorescence quenching induced by fluorescence resonance energy transfer (FRET) has been developed. The fluorescence of anti-THC-antibody, labeled with fluorescence dye DY-481XL, can be quenched after its binding to THC-BSA-quencher conjugate (bovine serum albumin coupled with THC and another fluorescence dye, DYQ-661, as quencher). This quenching effect is inhibited when the antibodies bind to free THC in aqueous sample, thus competing for binding sites with the THC-BSA-quencher conjugate. The extent of the inhibition corresponds to the concentration of THC in the samples. The assay principle is simple and the test duration is within 10 min. The detection limit for THC in buffer was 2 ng mL−1. In pooled saliva samples a detection limit of 50 ng mL−1 was achieved.  相似文献   

19.
Ji X  He Z  Ai X  Yang H  Xu C 《Talanta》2006,70(2):353-357
A competitive immunoassay for clenbuterol (CLB) based on capillary electrophoresis with chemiluminescence (CL) detection was established. The method was based on the competitive reaction of horseradish peroxidase (HRP)-labeled CLB (CLB-HRP) and free CLB with anti-CLB antiserum. The factors affecting the electrophoresis and CL detection were systematically investigated with HRP as a model sample. Under the optimal conditions, the tracer CLB-HRP and the immunoassay complex were separated, and the linear range and the detection limit (S/N = 3) for CLB were 5.0-40 nmol l−1 and 1.2 nmol l−1, respectively. The proposed method has been applied satisfactorily in the analysis of urine sample.  相似文献   

20.
The combination of capillary electrophoresis (CE) and mass spectrometry (MS) is particularly well adapted to bioanalysis due to its high separation efficiency, selectivity, and sensitivity; its short analytical time; and its low solvent and sample consumption. For clinical and forensic toxicology, a two-step analysis is usually performed: first, a screening step for compound identification, and second, confirmation and/or accurate quantitation in cases of presumed positive results. In this study, a fast and sensitive CE-MS workflow was developed for the screening and quantitation of drugs of abuse in urine samples. A CE with a time-of-flight MS (CE-TOF/MS) screening method was developed using a simple urine dilution and on-line sample preconcentration with pH-mediated stacking. The sample stacking allowed for a high loading capacity (20.5% of the capillary length), leading to limits of detection as low as 2 ng mL−1 for drugs of abuse. Compound quantitation of positive samples was performed by CE-MS/MS with a triple quadrupole MS equipped with an adapted triple-tube sprayer and an electrospray ionization (ESI) source. The CE-ESI-MS/MS method was validated for two model compounds, cocaine (COC) and methadone (MTD), according to the Guidance of the Food and Drug Administration. The quantitative performance was evaluated for selectivity, response function, the lower limit of quantitation, trueness, precision, and accuracy. COC and MTD detection in urine samples was determined to be accurate over the range of 10–1000 ng mL−1 and 21–1000 ng mL−1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号