共查询到20条相似文献,搜索用时 156 毫秒
1.
A newly synthesized alkyl phosphinic acid resin (APAR) was used for on-line preconcentration of trace rare earth elements (REES, lanthanides including yttrium) and then determined by inductively coupled plasma mass spectrometry. REEs in seawater could be on-line concentrated on the APAR packed column (4.6 mm i.d. × 50 mm in length), and eluted from the column with 0.5 mL 0.1 mol L−1 nitric acid within 30 s. An enrichment factor of nearly 400 was achieved for all REEs when the seawater sample volume was 200 mL, while the matrix and coexisting spectrally interfering ions such as barium, tin and antimony could be simultaneously separated. The detection limits of this proposed method for REEs were in the range from 1.43 pg L−1 of holmium to 12.7 pg L−1 of lanthanum. The recoveries of REEs were higher than 97.9%, and the precision of the relative standard deviation (R.S.D., n = 6) was less than 5%. The method has been applied to the determination of soluble REEs in seawater. 相似文献
2.
A novel low-blank method is described for the analysis of bismuth in seawater based on preconcentration using an ethylenediaminetriacetic acid chelating resin column followed by determination with inductively coupled plasma sector-field mass spectrometry (ICPSFMS). A sample is siphoned into and drains through the column with the flow rate being kept constant by using a flotation device. Bi in 250 mL of acidified seawater is extracted onto the column in this process and eluted with 2 mL of 3 M HNO3 followed by 3 mL of ultra-high purity water. The concentration of Bi in the eluate is measured by ICPMS. The benefits of the method compared to others are its simplicity, a smaller amount of seawater, and lower procedural blanks and detection limits at pg kg−1 levels. Data on dissolved Bi in open ocean reference samples of SAFe and GEOTRACES programs are presented for the first time. 相似文献
3.
A robust and rapid method for the determination of natural levels of beryllium (Be) in seawater was developed to facilitate mapping Be concentrations in the ocean. A solid-phase extraction method using a silica gel column was applied for preconcentration and purification of Be in seawater prior to determination of Be concentrations with inductively coupled plasma mass spectrometry (ICP-MS). Be was quantitatively adsorbed onto silica gel from solutions with pH values ranging from 6.3 to 9, including natural seawater. The chelating agent ethylenediamine tetraacetic acid was used to remove other ions in the seawater matrix (Na, Mg, and Ca) that interfere with the ICP-MS analysis. The reproducibility of the method was 3% based on triplicate analyses of natural seawater samples, and the detection limit was 0.4 pmol kg−1 for 250 mL of seawater, which is sufficient for the analysis of seawater in the open ocean. The method was then used to determine the vertical profile of Be in the eastern North Pacific Ocean, which was found to be a recycled-type profile in which the Be concentration increased with depth from the surface (7.2 pmol kg−1 at <200 m) to deep water (29.2 pmol kg−1 from 3500 m to the bottom). 相似文献
4.
Copper is an essential trace metal that shows a vertical recycled-scavenged profile in the ocean. To help elucidate the biogeochemical cycling of Cu in the present and past oceans, it is important to determine the distribution of Cu isotopes in seawater. However, precise isotopic analysis of Cu has been impaired by the low concentrations of Cu as well as co-existing elements that interfere with measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The objective of this study is to develop a simple Cu pre-concentration method using Nobias-chelate PA1 resin (Hitachi High Technologies). This extraction followed by anion exchange, allows precise analysis of the Cu isotopic composition in seawater. Using this method, Cu was quantitatively concentrated from seawater and >99.9999% of the alkali and alkaline earth metals were removed. The technique has a low procedural blank of 0.70 ng for Cu for a 2 L sample and the precision of the Cu isotopic analysis was ±0.07‰ (±2SD, n = 6). We applied this method to seawater reference materials (i.e., CASS-5 and NASS-6) and seawater samples obtained from the northwestern Pacific Ocean. The range of dissolved δ65Cu was 0.40–0.68‰. 相似文献
5.
Varga Z 《Analytical and bioanalytical chemistry》2008,390(2):511-519
An improved and novel sample preparation method for 226Ra determination in liquid samples by isotope dilution inductively coupled plasma sector field mass spectrometry using laboratory-prepared
228Ra tracer has been developed. The procedure involves a selective preconcentration achieved by applying laboratory-prepared
MnO2 resin followed by cation exchange chromatographic separation. In order to completely eliminate possible molecular interferences,
medium mass resolution (R = 4,000) combined with chemical separation was found to be a good compromise that enhanced the reliability of the method.
The detection limit of 0.084 fg g−1 (3.1 mBq kg−1) achieved is comparable to that of the emanation method or alpha spectrometry and is suitable for low-level environmental
measurements. The chemical recovery of the sample preparation method ranged from 72 to 94%. The proposed method enables a
rapid, accurate and less labor-intensive approach to routine environmental 226Ra determination than the radioanalytical techniques conventionally applied. 相似文献
6.
Based on carbon nanofibers (CNFs) as a solid phase extraction adsorbent, a microcolumn preconcentration method coupled to inductively coupled plasma mass spectrometry (ICP–MS) was developed for the determination of trace elements (Mn, Co and Ni). The effect of various experimental parameters such as pH, sample flow rate and volume, elution solution and interfering ions on the retention of the studied ions have been investigated systematically. During all the steps of the experimental process, Mn, Co and Ni could be quantitatively sorbed on the microcolumn containing CNFs in the range of pH 6.0–9.0, and then eluted completely with 0.5 mol ml− 1 HNO3. A preconcentration factor of 150-fold was obtained. The detection limits for Mn, Co and Ni were 40, 0.4 and 8.0 pg ml− 1, respectively, with relative standard deviations less than 6.0%. In order to validate the proposed method, two certified reference materials of human hair (GBW 07601) and mussel (GBW 08571), and water sample were analyzed with satisfactory results. The recoveries were between 95.0 and 114%. 相似文献
7.
A method for the determination of ultratrace amounts of Cr, Fe, Mn, Pb and Zn in seawater has been developed. It combined the low-blank magnesium hydroxide coprecipitation procedure with quadrupole inductively coupled plasma mass spectrometry and used the dynamic reaction cell technique to resolve the polyatomic interferences arising from the residual matrix, the solvent and plasma gases. Detection limits (3σB, n = 10) for Cr, Fe, Mn, Pb and Zn were 0.02, 0.10, 0.01, 0.002 and 0.19 nM, respectively, using 50 mL of seawater sample. The accuracy of the analytical procedure was verified by the analysis of the seawater reference materials CASS-4, NASS-5, SAFe D2 and SAFe S. The analytical precision ranged from 3% to 16% (n = 6), with a sample throughput of about 6 samples h−1. 相似文献
8.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article. 相似文献
9.
Dwinna Rahmi 《Talanta》2007,72(2):600-606
The multielement determination of trace metals in seawater was carried out by inductively coupled plasma mass spectrometry (ICP-MS) with aid of a down-sized chelating resin-packed minicolumn for preconcentration. The down-sized chelating resin-packed minicolumn was constructed with two syringe filters (DISMIC 13HP and Millex-LH) and an iminodiacetate chelating resin (Chelex 100, 200-400 mesh), with which trace metals in 50 mL of original seawater sample were concentrated into 0.50 mL of 2 M nitric acid, and then 100-fold preconcentration of trace metals was achieved. Then, 0.50 mL analysis solution was subjected to the multielement determination by ICP-MS equipped with a MicroMist nebulizer for micro-sampling introduction. The preconcentration and elution parameters such as the sample-loading flow rate, the amount of 1 M ammonium acetate for elimination of matrix elements, and the amount of 2 M nitric acid for eluting trace metals were optimized to obtain good recoveries and analytical detection limits for trace metals. The analytical results for V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U in three kinds of seawater certified reference materials (CRMs; CASS-3, NASS-4, and NASS-5) agreed well with their certified values. The observed values of rare earth elements (REEs) in the above seawater CRMs were also consistent with the reference values. Therefore, the compiled reference values for the concentrations of REEs in CASS-3, NASS-4, and NASS-5 were proposed based on the observed values and reference data for REEs in these CRMs. 相似文献
10.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials. 相似文献
11.
Hui-Fang Hsieh 《Talanta》2009,79(2):183-240
This work describes a simple procedure for blood lead level determination. The proposed method requires little sample pretreatment and subsequent direct analysis of a dried blood spot on a filter membrane using laser ablation coupled with inductively coupled plasma mass spectrometry (LA-ICP-MS). In general, LA-ICP-MS studies are somewhat limited by the lack of matrix-matched standards for calibration purposes. Here we describe aqueous standard calibration and matrix-matched calibration methods. This method was validated by analysis of the reference materials. With the matrix-matched calibration method, the recovery ranged from 97.8% to 112.8%, while the aqueous standard calibration method ranged 90.4% to 122.4%. The lower detection limit was estimated as 0.1 ng mL−1. The determination precision, expressed as the relative standard deviation (RSD), was not worse than 10% for all results. A sample throughput of approximately 5 min per sample made it possible to rapidly screen a large number of samples. 相似文献
12.
为开展重金属监测及环境保护,本文建立了电感耦合等离子体质谱法测定固体生物质燃料中重金属方法。对样品全消解酸溶法进行了实验研究,确定了微波消解酸体系和微波消解程序。采用Ge和In作为内标元素消除仪器干扰,方法线性关系良好,线性系数>0.999,检出限为0.001~0.089mg/kg。采用标准物质对方法准确性和稳定性进行验证,各元素测定值均在标准证书值范围内,相对标准偏差在0.36%~3.96%,Hg的加标平均回收率为104.7%。通过3家实验室协同实验验证了方法准确性,并给出了方法精密度。 相似文献
13.
J.C. Raposo U. Villanueva L. Bartolomé M. Olivares J.A. Carrero A. Sarmiento N. Etxebarria J.M. Madariaga 《Microchemical Journal》2011,99(2):252-259
Inductively coupled plasma mass spectrometry analysis of trace and major elements of mussel tissues can be quickly and accurately analyzed after cleaning up the interfering fat content before the sample is digested in a microwave oven. Making use of experimental designs, the clean up procedure was achieved by the extraction of 1 g of freeze-dried tissue sample stirred with 5 ml of dichloromethane during five minutes. The microwave assisted digestion of the fat free samples was carried out with 0.2 g of tissue sample, 15 ml of 7.0% nitric acid with a power of 980 W during 18 min. The analytical method efficiency (accuracy and precision) was evaluated with a CRM: (NIST 2977, mussel tissue) and real mussel samples analyzed previously. The results confirmed the accuracy of the analysis by agreement with the previous results but the precision was significantly improved. The developed method allows operating routinely permitting to large numbers of samples to be quickly screened for trace metals. 相似文献
14.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science. 相似文献
15.
以HNO3-H2O2为消解体系,采用微波对沉积物进行消解,建立了普里兹湾沉积物中微量元素的电感耦合等离子体质谱(ICP-MS)测定方法。从样品分析数据可以看出:8个站位10种元素总量变化范围为493.41~1481.02μg/g,总量最大值是最小值的3.00倍。元素Ba、Mn在总量中占了很大比例,V次之,而As、Mo、Ag、Cd的含量很少。大部分元素检出限可达ng/L,仅Co、Mo 2种元素的检出限稍高;各元素线性良好,相关系数r2≥0.9997。方法的RSD<5.0%,适用于普里兹湾沉积物中微量元素的定量分析。 相似文献
16.
17.
建立电感耦合等离子体-质谱(ICP-MS)法测定高纯硫粉中Si、P、V、Cr、Mn、Ni、Co、Cu、As、Zn、Zr、Cd、In、Sb、Te、Pb、Bi等17种痕量金属杂质含量的方法。样品用HClO4溶解后挥发硫基体,使样品中杂质元素得到富集,各杂质元素的方法检出限为0.1~50ng/g。方法加标回收率为83%~117%。各杂质元素均为10ng/mL的混合标准溶液平行7次测定的相对标准偏差均小于5%。该方法能够满足纯度为99.999%~99.9999%的高纯硫样品中杂质测定的需要。 相似文献
18.
电感耦合等离子体质谱技术最新进展 总被引:22,自引:0,他引:22
对1998年以来电感耦合等离子体质谱技术(ICP-MS)的最新进展作一简要回顾。内容包括同位素比值分析、双聚焦扇形磁场高分辨ICP-MS、多接收器磁扇形等离子体质谱仪(MC-ICP-MS)、飞行时间等离子体质谱仪(ICP-TOF-MS)、“冷”等离子体及屏蔽炬技术以及动态碰撞/反应池技术等进展。 相似文献
19.
A new strategy for the determination of trace Ni in food by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) was proposed. The food samples were analyzed by ICP-MS/MS after microwave digestion. In the MS/MS mode,O2and NH3/He were used as reaction gases, respectively, while Ni+was used to undergo mass shift reactions with reaction gases to eliminate spectral interference. Although the spectral interference can be eliminated to near the background level in both reaction modes, using O2as a reaction gas in the MS/MS mode to convert Ni+into NiO+could provide a higher sensitivity and a lower limit of detection (LOD). The mass shift reaction mechanism of Ni+and O2was revealed through theoretical calculation and experimental verification. Under the optimized conditions, the LOD of Ni was as low as 11.5 ng/L. The accuracy of the method was evaluated by analyzing the standard reference materials and comparing them with the national standard GB 5009.138-2017 method. The results showed that at the 95% confidence level, there was no significant difference between the analytical results of this method and those of the national standard method, and the relative standard deviations (RSDs) were 2.8%-4.7%. The measured values of two analytical methods were basically consistent with the certified values of standard reference materials. © 2023 The Authors. 相似文献
20.
M.L. Alonso Castillo E. Vereda Alonso M.T. Siles Cordero J.M. Cano Pavn A. García de Torres 《Microchemical Journal》2011,98(2):234-239
In this work, a fast microwave assisted extraction procedure was developed and optimized for the heavy metals (Cu, Ni, Cr, Pb and Cd) partitioning in the three-stage sequential extraction procedure proposed by the European Standards, Measurements and Testing (SM&;T) Program, formerly the Community Bureau of Reference (BCR). The microwave oven procedure was optimized to obtain extraction efficiencies similar to the conventional BCR procedure, in less time, while using smaller volumes of reagents. In the optimization process, three variables (extraction time, ramping time and microwave power) were considered as factors and as a response the concentration of different metal ions in each individual BCR fraction. Interactions between analytical factors and their optimized levels were investigated using a central composite design. Extractable metals obtained by both comparable methodologies were measured by inductively coupled plasma mass spectrometry. With the use of optimal microwave conditions, steps 1–3 of the sequential extraction (including the hydrogen peroxide digestion in step 3) could be completed between 21 and 22 min. Detection limits were between 1 and 18 ng l− 1. The accuracy of the proposed method was checked with a certified reference material (CRM) of Lake Sediment BCR 701. Values obtained were in accordance with those reported for the certified material with only a few exceptions. Different origin sediments (river and marine) were analyzed by both BCR and MW procedures, and the results obtained were comparable according to the t-paired-test for a 95% confidence level. 相似文献