首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(18):2859-2871
A method coupling high-performance liquid chromatography with diode-array detector and electrospray ionization mass spectrometry (HPLC-DAD-ESI/MSn) has been developed for the separation and characterization of atorvastatin and its related impurities. The results obtained using positive ion mode showed some diagnostic fragments that are useful for the identification of atorvastatin related impurities in real samples. Quantitative analysis of drug impurities was performed in the multiple reaction monitoring mode. Quantification limits for impurities were in the ranges 21.5–70.8 ng mL?1. The method was successfully applied to the drug purity evaluation and quantitative determination of atorvastatin related impurities in bulk drugs and pharmaceutical formulations.  相似文献   

2.
二肽衍生物的电喷雾质谱研究   总被引:1,自引:0,他引:1  
基于HIV整合酶核心结构域,合成了以HIV整合酶为靶标的二肽衍生物,采用多级质谱技术(二级、三级)研究二肽衍生物在质谱条件下的化学键断裂途径,发现主要的断裂方式为:氨基与羰基间的NH-CO键的断裂以及N-(苯并噻唑-2-基)甲酰氨基与亚甲基间的CO-C间的断裂。  相似文献   

3.
In this work, sorbent-attached membrane funnel-based spray ionization mass spectrometry was explored for quantitative analysis of anti-diabetic drugs spiked in human plasma. C18-attached membrane funnel was fabricated for in situ extraction and clean-up to alleviate matrix suppression effect in the ionization process. Repaglinide was used as a target analyte of anti-diabetic drugs. Under optimal working conditions, good linearity (R2 > 0.99) was obtained in the concentration range of 1–100 ng mL−1. The method detection limit of target drugs spiked in the human plasma was around 0.30 ng mL−1. Through the application of an isotope-labeled internal standard, the signal fluctuation caused by residual background matrices was largely alleviated and the precision of measurement (RSD) was below 15%. The recovery of repaglinide for 5, 25, and 100 ng mL−1 of spiked human plasma matrixes ranged from 87% to 112%. The developed method was successfully applied to determine repaglinide in plasma volunteers who orally received a dose of drug association. Our results demonstrated that membrane funnel-based spray is a simple and sensitive method for rapid screening analysis of complex biological samples.  相似文献   

4.
Although marine oysters contain abundant amounts of ether-linked aminophospholipids, the structural identification of the various molecular species has not been reported. We developed a normal-phase silica liquid chromatography/negative-ion electrospray ionization/quadrupole multiple-stage linear ion-trap mass spectrometric (NPLC-NI-ESI/Q-TRAP-MS3) method for the structural elucidation of ether molecular species of serine and ethanolamine phospholipids from marine oysters. The major advantages of the approach are (i) to avoid incorrect selection of isobaric precursor ions derived from different phospholipid classes in a lipid mixture, and to generate informative and clear MSn product ion mass spectra of the species for the identification of the sn-1 plasmanyl or plasmenyl linkages, and (ii) to increase precursor ion intensities by “concentrating” lipid molecules of each phospholipid class for further structural determination of minor molecular species. Employing a combination of NPLC-NI-ESI/MS3 and NPLC-NI-ESI/MS2, we elucidated, for the first time, the chemical structures of docosahexaenoyl and eicosapentaenoyl plasmenyl phosphatidylserine (PS) species and differentiated up to six isobaric species of diacyl/alkylacyl/alkenylacyl phosphatidylethanolamine (PE) in the US pacific oysters. The presence of a high content of both omega-3 plasmenyl PS/plasmenyl PE species and multiple isobaric molecular species isomers is the noteworthy characteristic of the marine oyster. The simple and robust NPLC-NI-ESI/MSn-based methodology should be particularly valuable in the detailed characterization of marine lipid dietary supplements with respect to omega-3 aminophospholipids.  相似文献   

5.
Today, immunoassays and several chromatographic methods are in use for drug screening in clinical and forensic toxicology and in doping control. For further proof of the authors’ new metabolite-based liquid chromatography-mass spectrometry (LC-MSn) screening concept, the detectability of drugs of abuse and their metabolites using this screening approach was studied. As previously reported, the corresponding reference library was built up with MS2 and MS3 wideband spectra using a LXQ linear ion trap with electrospray ionization in the positive mode and full scan information-dependent acquisition. In addition to the parent drug spectra recorded in methanolic solution, metabolite spectra were identified after protein precipitation of urine from rats after administration of the corresponding drugs and added to the library. This consists now of data of over 900 parent compounds, including 87 drugs of abuse, and of over 2,300 metabolites and artifacts, among them 436 of drugs of abuse. Recovery, process efficiency, matrix effects, and limits of detection for selected drugs of abuse were determined using spiked human urine, and the resulting data have been acceptable. Using two automatic data evaluation tools (ToxID and SmileMS), the intake of 54 of the studied drugs of abuse could be confirmed in urine samples of drug users after protein precipitation and LC separation. The following drugs classes were covered: stimulants, designer drugs, hallucinogens, (synthetic) cannabinoids, opioids, and selected benzodiazepines. The presented LC-MSn method complements the well-established gas chromatography-mass spectroscopy procedure in the authors’ laboratory.  相似文献   

6.
The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a “scheduled” survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP® hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization–MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography–mass spectrometry, and liquid chromatography–diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).  相似文献   

7.
Considering the vast variety of synthetic cannabinoids and herbal mixtures – commonly known as ‘Spice’ or ‘K2’ – on the market and the resulting increase of severe intoxications related to their consumption, there is a need in clinical and forensic toxicology for comprehensive up‐to‐date screening methods. The focus of this project aimed at developing and implementing an automated screening procedure for the detection of synthetic cannabinoids in serum using a liquid chromatography‐ion trap‐MS (LC‐MSn) system and a spectra library‐based approach, currently including 46 synthetic cannabinoids and 8 isotope labelled analogues. In the process of method development, a high‐temperature ESI source (IonBoosterTM, Bruker Daltonik) and its effects on the ionization efficiency of the investigated synthetic cannabinoids were evaluated and compared to a conventional ESI source. Despite their structural diversity, all investigated synthetic cannabinoids benefitted from high‐temperature ionization by showing remarkably higher MS intensities compared to conventional ESI. The employed search algorithm matches retention time, MS and MS2/MS3 spectra. With the utilization of the ionBooster source, limits for the automated detection comparable to cut‐off values of routine MRM methods were achieved for the majority of analytes. Even compounds not identified when using a conventional ESI source were detected using the ionBooster‐source. LODs in serum range from 0.1 ng/ml to 0.5 ng/ml. The use of parent compounds as analytical targets offers the possibility of instantly adding new emerging compounds to the library and immediately applying the updated method to serum samples, allowing the rapid adaptation of the screening method to ongoing forensic or clinical requirements. The presented approach can also be applied to other specimens, such as oral fluid or hair, and herbal mixtures and was successfully applied to authentic serum samples. Quantitative MRM results of samples with analyte concentrations above the determined LOD were confirmed as positive findings by the presented method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

8.
Desorption electrospray ionization mass spectrometry (DESI‐MS) has been applied to the direct analysis of sample media for target chemicals, including chemical warfare agents (CWA), without the need for additional sample handling. During the present study, solid‐phase microextraction (SPME) fibers were used to sample the headspace above five organophosphorus CWA, O‐isopropyl methylphosphonofluoridate (sarin, GB), O‐pinacolyl methylphosphonofluoridate (soman, GD), O‐ethyl N,N‐dimethyl phosphoramidocyanidate (tabun, GA), O‐cyclohexyl methylphosphonofluoridate (cyclohexyl sarin, GF) and O‐ethyl S‐2‐diisopropylaminoethyl methyl phosphonothiolate (VX) spiked into glass headspace sampling vials. Following sampling, the SPME fibers were introduced directly into a modified ESI source, enabling rapid and safe DESI of the toxic compounds. A SYNAPT HDMS? instrument was used to acquire time‐aligned parallel (TAP) fragmentation data, which provided both ion mobility and MSn (n = 2 or 3) data useful for the confirmation of CWA. Unique ion mobility profiles were acquired for each compound and characteristic product ions of the ion mobility separated ions were produced in the Triwave? transfer collision region. Up to six full scanning MSn spectra, containing the [M + H]+ ion and up to seven diagnostic product ions, were acquired for each CWA during SPME fiber analysis. A rapid screening approach, based on the developed methodology, was applied to several typical forensic media, including Dacron sampling swabs spiked with 5 µg of CWA. Background interference was minimal and the spiked CWA were readily identified within one minute on the basis of the acquired ion mobility and mass spectrometric data. Copyright © 2010 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   

9.
MassBank is the first public repository of mass spectra of small chemical compounds for life sciences (<3000 Da). The database contains 605 electron‐ionization mass spectrometry(EI‐MS), 137 fast atom bombardment MS and 9276 electrospray ionization (ESI)‐MSn data of 2337 authentic compounds of metabolites, 11 545 EI‐MS and 834 other‐MS data of 10 286 volatile natural and synthetic compounds, and 3045 ESI‐MS2 data of 679 synthetic drugs contributed by 16 research groups (January 2010). ESI‐MS2 data were analyzed under nonstandardized, independent experimental conditions. MassBank is a distributed database. Each research group provides data from its own MassBank data servers distributed on the Internet. MassBank users can access either all of the MassBank data or a subset of the data by specifying one or more experimental conditions. In a spectral search to retrieve mass spectra similar to a query mass spectrum, the similarity score is calculated by a weighted cosine correlation in which weighting exponents on peak intensity and the mass‐to‐charge ratio are optimized to the ESI‐MS2 data. MassBank also provides a merged spectrum for each compound prepared by merging the analyzed ESI‐MS2 data on an identical compound under different collision‐induced dissociation conditions. Data merging has significantly improved the precision of the identification of a chemical compound by 21–23% at a similarity score of 0.6. Thus, MassBank is useful for the identification of chemical compounds and the publication of experimental data. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Several penta- and hexa-substituted aryloxycyclotriphosphazenes were synthesized and investigated by electrospray ionization tandem mass spectrometry (ESI-MSn). Their main fragmentation pathways are proposed based on the MSn and accurate mass data. An apparent hydrolysis reaction is an important fragmentation process exhibited in the ESI-MS/MS spectra for all of them. Also interesting is the intramolecular electrocyclic ring closure observed in ESI-MS/MS spectra of them. These observations may have some potential applications in the distinction between the mass spectra of penta- and hexa-substituted hexachlorocyclotriphosphazene derivatives.  相似文献   

11.
Applications of tandem mass spectrometry (MS/MS) techniques coupled with high-performance liquid chromatography (HPLC) in the identification and determination of phase I and phase II drug metabolites are reviewed with an emphasis on recent papers published predominantly within the last 6 years (2002–2007) reporting the employment of atmospheric pressure ionization techniques as the most promising approach for a sensitive detection, positive identification and quantitation of metabolites in complex biological matrices. This review is devoted to in vitro and in vivo drug biotransformation in humans and animals. The first step preceding an HPLC-MS bioanalysis consists in the choice of suitable sample preparation procedures (biomatrix sampling, homogenization, internal standard addition, deproteination, centrifugation, extraction). The subsequent step is the right optimization of chromatographic conditions providing the required separation selectivity, analysis time and also good compatibility with the MS detection. This is usually not accessible without the employment of the parent drug and synthesized or isolated chemical standards of expected phase I and sometimes also phase II metabolites. The incorporation of additional detectors (photodiode-array UV, fluorescence, polarimetric and others) between the HPLC and MS instruments can result in valuable analytical information supplementing MS results. The relation among the structural changes caused by metabolic reactions and corresponding shifts in the retention behavior in reversed-phase systems is discussed as supporting information for identification of the metabolite. The first and basic step in the interpretation of mass spectra is always the molecular weight (MW) determination based on the presence of protonated molecules [M+H]+ and sometimes adducts with ammonium or alkali-metal ions, observed in the positive-ion full-scan mass spectra. The MW determination can be confirmed by the [M-H]- ion for metabolites providing a signal in negative-ion mass spectra. MS/MS is a worthy tool for further structural characterization because of the occurrence of characteristic fragment ions, either MS n analysis for studying the fragmentation patterns using trap-based analyzers or high mass accuracy measurements for elemental composition determination using time of flight based or Fourier transform mass analyzers. The correlation between typical functional groups found in phase I and phase II drug metabolites and corresponding neutral losses is generalized and illustrated for selected examples. The choice of a suitable ionization technique and polarity mode in relation to the metabolite structure is discussed as well.  相似文献   

12.
13.
Detection of drugs in tissue typically requires extensive sample preparation in which the tissue is first homogenized, followed by drug extraction, before the extracts are finally analyzed by LC/MS. Directly analyzing drugs in intact tissue would eliminate any complications introduced by sample pretreatment. A matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS n ) method as been developed for the quantification of cocaine present in postmortem brain tissue of a chronic human cocaine user. It is shown that tandem mass spectrometry (MS2 and MS3) increase selectivity, which is critical for differentiating analyte ions from background ions such as matrix clusters and endogenous compounds found in brain tissue. It is also shown that the use of internal standards corrects for signal variability during quantitative MALDI, which can be caused by inhomogeneous crystal formation, inconsistent sample preparation, and laser shot-to-shot variability. The MALDI-MS n method developed allows for a single MS3 experiment that uses a wide isolation window to isolate both analyte and internal standard target ions. This method is shown to provide improved precision [∼10–20 times reduction in percent relative standard deviation (%RSD)] for quantitative analysis compared to using two alternating MS3 experiments that separately isolate the target analyte and internal standard ions.  相似文献   

14.
Buryakov IA 《Talanta》2003,61(3):369-375
Ion mobility increment spectrometry (IMIS) is a high sensitive selective ionization technology for detection and identification of ultra-trace constituents, including toxic compounds, CW-agents, drugs and explosives in ambient air or liquid sample. Like an ion mobility spectrometry (IMS), this technology rests on sampling air containing a mixture of trace constituents, its ionization, spatial separation of produced ions and separated ions detection. Unlike IMS, ions of different types in IMIS are separated by ion mobility increment, α. Value α, is a function of the parameters: electric field strength and form, atmospheric pressure. To exclude the influence of these parameters on an α, the method of explosives identification by a standard compound was suggested. As a standard compound iodine was used. The relationship among the mobility coefficient increments equal to the relationship among the compensation voltage αi/αiodine=Ui/Uiodine is determined, where i are ions of 1,3-dinitrobenzene, 1,3,5-trinitrobenzene, p-mononitrotoluene, 2,4-dinitrotoluene and 2,4,6-trinitrotoluene This relationship is practically independent of the above mentioned parameters in the range 25<E/N<90 Td. The limits of the relative error of this relationship are determined both from spectra of individual compounds and nitrocompound-iodine mixtures.  相似文献   

15.
A series of α‐acyloxyhydroperoxy aldehydes was analyzed with direct infusion electrospray ionization tandem mass spectrometry (ESI/MSn) as well as liquid chromatography coupled with the mass spectrometry (LC/MS). Standards of α‐acyloxyhydroperoxy aldehydes were prepared by liquid‐phase ozonolysis of cyclohexene in the presence of carboxylic acids. Stabilized Criegee intermediate (SCI), a by‐product of the ozone attack on the cyclohexene double bond, reacted with the selected carboxylic acids (SCI scavengers) leading to the formation of α‐acyloxyhydroperoxy aldehydes. Ionization conditions were optimized. [M + H]+ ions were not formed in ESI; consequently, α‐acyloxyhydroperoxy aldehydes were identified as their ammonia adducts for the first time. On the other hand, atmospheric‐pressure chemical ionization has led to decomposition of the compounds of interest. Analysis of the mass spectra (MS2 and MS3) of the [M + NH4]+ ions allowed recognizing the fragmentation pathways, common for all of the compounds under study. In order to get detailed insights into the fragmentation mechanism, a number of isotopically labeled analogs were also studied. To confirm that the fragmentation mechanism allows predicting the mass spectrum of different α‐acyloxyhydroperoxy aldehydes, ozonolysis of α‐pinene, a very important secondary organic aerosol precursor, was carried out. Spectra of the two ammonium cationized α‐acyloxyhydroperoxy aldehydes prepared with α‐pinene, cis‐pinonic acid as well as pinic acid were predicted very accurately. Possible applications of the method developed for the analysis of α‐acyloxyhydroperoxy aldehydes in SOA samples, as well as other compounds containing hydroperoxide moiety are discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
质谱作为一种具有高准确度、高灵敏度、高选择性的检测仪器,在公共安全领域有着重要的应用前景.公共安全领域的需求主要涉及毒品、毒物、爆炸物等化学物质的现场快速检测,因其影响广泛,检测结果需非常准确.作为实验室分析仪器,质谱的准确性和速度能满足公共安全的应用需求,但作为现场快速检测的仪器仍需要一定改进.现场快速检测一方面要求...  相似文献   

17.
Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes.  相似文献   

18.
In contrast to GC-MS libraries, currently available LC-MS libraries for toxicological detection contain besides parent drugs only some main metabolites limiting their applicability for urine screening. Therefore, a metabolite-based LC-MS n screening procedure was developed and exemplified for antidepressants. The library was built up with MS2 and MS3 wideband spectra using an LXQ linear ion trap with electrospray ionization in the positive mode and full-scan information-dependent acquisition. Pure substance spectra were recorded in methanolic solution and metabolite spectra in urine from rats after administration of the corresponding drugs. After identification, the metabolite spectra were added to the library. Various drugs and metabolites could be sufficiently separated. Recovery, process efficiency, matrix effects, and limits of detection for selected drugs were determined using protein precipitation. Automatic data evaluation was performed using ToxID and SmileMS software. The library consists of over 700 parent compounds including 45 antidepressants, over 1,600 metabolites, and artifacts. Protein precipitation led to sufficient results for sample preparation. ToxID and SmileMS were both suitable for target screening with some pros and cons. In our study, only SmileMS was suitable for untargeted screening being not limited to precursor selection. The LC-MS n method was suitable for urine screening as exemplified for antidepressants. It also allowed detecting unknown compounds based on known fragment structures. As ion suppression can never be excluded, it is advantageous to have several targets per drug. Furthermore, the detection of metabolites confirms the body passage. The presented LC-MS n method complements established GC-MS or LC-MS procedures in the authors’ lab.  相似文献   

19.
A novel analytical workflow was developed and applied for the detection and identification of unknown xenobiotics in biological samples. High-resolution mass spectrometry (HRMS)-based data-independent MSE acquisition was employed to record full scan MS and fragment spectral datasets of test and control samples. Then, an untargeted data-mining technique, background subtraction, was utilized to find xenobiotics present only in test samples. Structural elucidation of the detected xenobiotics was accomplished by database search, spectral interpretation, and/or comparison with reference standards. Application of the workflow to analysis of unknown xenobiotics in plasma samples collected from four poisoned patients led to generation of xenobiotic profiles, which were regarded as xenobiotic fingerprints of the individual samples. Among 19 xenobiotics detected, 11 xenobiotics existed in a majority of the patients' plasma samples, thus were considered as potential toxins. The follow-up database search led to the tentative identification of azithromycin (X5), α-chaconine (X9) and penfluridol (X12). The identity of X12 was further confirmed with its reference standard. In addition, one xenobiotic component (Y5) was tentatively identified as a penfluridol metabolite. The remaining unidentified xenobiotics listed in the xenobiotic fingerprints can be further characterized or identified in retrospective analyses after their spectral data and/or reference compounds are available. This HRMS-based workflow may have broad applications in the detection and identification of unknown xenobiotics in individual biological samples, such as forensic and toxicological analysis and sport enhancement drug screening.  相似文献   

20.
An integrated approach combining data acquisition using MSE and multi-period product ion scan (mpMS/MS), with high-resolution characteristic extracted ion chromatograms (hcXIC) as a data mining method, was developed for in vivo drug metabolites screening and identification. This approach is illustrated by analyzing metabolites of a potential anticancer agent, 3,6,7-trimethoxyphenanthroindolizidine (CAT) in rat urine based on rapid resolution liquid chromatography combined with tandem mass spectrometry (RRLC–MS/MS). Untargeted full-scan MSE enabled the high-throughput acquisition of potential metabolites, and targeted mpMS/MS contributed to the sensitivity and specificity of the acquisition of molecules of interest. The data processing method hcXIC, based on the structure of CAT, was shown to be highly effective for the metabolite discovery. Through the double-filtering effect of the characteristic ion and accurate mass, conventional extracted ion chromatograms that contained a substantial number of false-positive peaks were simplified into chromatograms essentially free of endogenous interferences. As a result, 21 metabolites were detected in rat urine after oral administration of CAT. Based on the characteristic fragmentation patterns of the phenanthroindolizidine alkaloid, the structures of 9 metabolites were identified. Furthermore, the interpretation of the MS/MS spectra of these metabolites enabled the determination of demethylation position as well as the differentiation between N-oxidized and hydroxylated metabolites.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号