首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A method has been developed based on an on-line isotope dilution technique couple with laser ablation/inductively coupled plasma mass spectrometry (LA-ICP-MS), for the determination of boron in p-type silicon wafers. The laser-ablated sample aerosol was mixed on-line with an enriched boron aerosol supplied continuously using a conventional nebulization system. Upon mixing the two aerosol streams, the isotope ratio of boron changed rapidly and was then recorded by the ICP-MS system for subsequent quantification based on the isotope dilution principle. As an on-line solid analysis method, this system accurately quantifies boron concentrations in silicon wafers without the need for an internal or external solid reference standard material. Using this on-line isotope dilution technique, the limit of detection for boron in silicon wafers is 2.8 × 1015 atoms cm−3. The analytical results obtained using this on-line methodology agree well with those obtained using wet chemical digestion methods for the analysis of p-type silicon wafers containing boron concentrations ranging from 1.0 × 1016 to 9.6 × 1018 atoms cm−3.  相似文献   

2.
A new method for the determination of seawater Pb isotope compositions and concentrations was developed, which combines and optimizes previously published protocols for the separation and isotopic analysis of this element. For isotopic analysis, the procedure involves initial separation of Pb from 1 to 2 L of seawater by co-precipitation with Mg hydroxide and further purification by a two stage anion exchange procedure. The Pb isotope measurements are subsequently carried out by thermal ionization mass spectrometry using a 207Pb–204Pb double spike for correction of instrumental mass fractionation. These methods are associated with a total procedural Pb blank of 28 ± 21 pg (1sd) and typical Pb recoveries of 40–60%. The Pb concentrations are determined by isotope dilution (ID) on 50 mL of seawater, using a simplified version of above methods. Analyses of multiple aliquots of six seawater samples yield a reproducibility of about ±1 to ±10% (1sd) for Pb concentrations of between 7 and 50 pmol/kg, where precision was primarily limited by the uncertainty of the blank correction (12 ± 4 pg; 1sd). For the Pb isotope analyses, typical reproducibilities (±2sd) of 700–1500 ppm and 1000–2000 ppm were achieved for 207Pb/206Pb, 208Pb/206Pb and 206Pb/204Pb, 207Pb/204Pb, 208Pb/204Pb, respectively. These results are superior to literature data that were obtained using plasma source mass spectrometry and they are at least a factor of five more precise for ratios involving the minor 204Pb isotope. Both Pb concentration and isotope data, furthermore, show good agreement with published results for two seawater intercomparison samples of the GEOTRACES program. Finally, the new methods were applied to a seawater depth profile from the eastern South Atlantic. Both Pb contents and isotope compositions display a smooth evolution with depth, and no obvious outliers. Compared to previous Pb isotope data for seawater, the 206Pb/204Pb ratios are well correlated with 207Pb/206Pb, underlining the significant improvement achieved in the measurement of the minor 204Pb isotope.  相似文献   

3.
Fujii T  Suzuki D  Watanabe K  Yamana H 《Talanta》2006,69(1):32-36
The total evaporation technique of thermal ionization mass spectrometry was applied to the isotopic analysis of chromium. High measurement reproducibility of the chromium isotope ratios was verified (2 S.E. < 0.05% (53Cr/52Cr)), while a clear mass fractionation effect was observed by using conventional measurement technique. The chromium isotope ratios analyzed by the total evaporation method were not affected by the sample amount on the rhenium filament (50-500 ng Cr). The isotopic analysis under the coexistence of zinc was also performed, and its effect to the chromium isotope ratios was confirmed.  相似文献   

4.
Hg concentrations in seawater are usually too low to allow direct (without pre-concentration and removal of salt matrix) measurement of its isotope ratios with multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS). Therefore, a new method for the pre-concentration of Hg from large volumes of seawater was developed. The final method allows for relatively fast (about 2.5 L h−1) and quantitative pre-concentration of Hg from seawater samples with an average Hg recovery of 98 ± 6%. Using this newly developed method we determined Hg isotope ratios in seawater. Reference seawater samples were compared to samples potentially impacted by anthropogenic activity. The results show negative mass dependent fractionation relative to the NIST 3133 Hg standard with δ202Hg values in the range from −0.50‰ to −1.50‰. In addition, positive mass independent fractionation of 200Hg was observed for samples from reference sites, while impacted sites did not show significant Δ200Hg values. Although the influence of the impacted sediments is limited to the seawater and particulate matter in very close proximity to the sediment, this observation may raise the possibility of using Δ200Hg to distinguish between samples from impacted and reference sites.  相似文献   

5.
Inductively coupled plasma mass spectrometry (ICP-MS) has now been developed for application to stable isotope tracer investigations of several minerals/trace elements. Use of this method for such purposes requires an understanding of a number of fundamental issues: analytical chemistry performance of the method of isotopic analysis, relationship of the level of enriched isotope administered to the subject with background level of the isotope already present, the issues of cost, and finally the specific details of the biological issues to be explored.In this paper, a brief discussion of these issues is presented. As an example, the discussion is presented in relation to selected aspects of metabolism of selenium, employing the three stable isotopes74Se,77Se, and82Se in the rat as the biological model.Analytical performance of hydride generation/ICP-MS is discussed for the required analyses of selenium isotopes. It is shown that for solutions containing 10 ng/ml Se of natural isotopic composition, optimized signal/background ratios greater than 40/1 can be obtained, resulting in worst-case detection limits (ng Se) of 2 (74Se), and 0.6 (77,82Se). The precision and accuracy of isotope ratio measurements for the method used routinely in biological studies is 1%. The accuracy of the method for quantitative isotopic analysis is compared with hydride generation/atomic absorption spectrophotometry (HG/AAS). The following results are given (g Se/g or ml; mean + 1 SD,n = 3–5; first HG/ICP-MS, second HG/AAS): SRM 1577a [bovine liver] 0.697 ± 0.002 versus 0.69 ± 0.01; human blood plasma 0.098 ± 0.001 versus 0.135 ± 0.008; human red cells 0.211 ± 0.002 versus 0.216 ± 0.012; and human urine 0.0473 ± 0.0003 versus 0.0489 ± 0.0003.An experiment is described with the rat to show the feasibility of the method for studies of selenium metabolism. Rats were placed on Se-free diet for eight weeks, given their Se requirements in the drinking water in the form of76SeO 3 2– and a single-day (day 3) replacement of their water with that containing highly enriched74SeO 3 2– . Isotopic analysis of carcass and selected organs revealed a high degree of isotopic enrichment with respect to74Se during the entire eight weeks of the experiment, indicating the feasibility of this approach for detailed investigations of selenium metabolism in the rat.Presented in part at the 1989 European Winter Conference on Plasma Spectrochemistry, Reutte, Austria  相似文献   

6.
We developed an analytical method for measuring compound-specific stable carbon isotope ratios (δ13C) of phenols and nitrophenols in filter samples of particulate organic matter. The method was tested on 13 phenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA), together with four nonphenolic compounds. The data obtained by our method required two specific corrections for the determination of valid δ13C values: (1) for nitro compounds, the routine correction with use of m/z 46 for the contribution of 12C17O16O molecules) to m/z 45 was modified due to impact of NO2 on the m/z 46 trace, and (2) for the derivatized phenols, measured δ13C values were corrected for the shift in δ13C due to the addition of carbon atoms from the BSTFA moiety. Analysis of standard-spiked filters showed that overall there was a small compound-dependent bias in the δ13C values: the average bias ± the standard error of the mean of −0.21 ± 0.1‰ for the standard compounds tested, except 3-methylcatechol, methylhydroquinone, 4-methyl-2-nitrophenol, and 2,6-dimethyl-4-nitrophenol, whereas the average biases ± the standard errors of the mean for those were +1.2 ± 0.3‰, +1.2 ± 0.2‰, −1.2 ± 0.2‰, and −1.4 ± 0.5‰, respectively, when the injected mass of a derivatized compound exceeded 15 ngC. In situations where such small biases and uncertainties are acceptable, the method described here could be used to obtain valuable information about δ13C values. We also analyzed a real filter sample to demonstrate the practical applicability of the method.  相似文献   

7.
Iron isotope fractionation between liquid and vapor iron pentacarbonyl was measured in a closed system at ∼0 and ∼21 °C to determine if Fe isotope analysis of iron pentacarbonyl vapor is viable using electron-impact, gas-source mass spectrometry. At the 2σ level, there is no significant Fe isotope fractionation between vapor and liquid under conditions thought to reflect equilibrium. Experiments at ∼0 °C indicate iron pentacarbonyl vapor is ∼0.05 per mil (‰) greater in 56Fe/54Fe than liquid iron pentacarbonyl, which is just resolvable at the 1σ level. Partial decomposition of iron pentacarbonyl vapor or liquid to an iron oxide or iron metal shows that significant isotopic fractionation occurs, where the decomposed product has a lower 56Fe/54Fe ratio as compared to the starting iron pentacarbonyl. It follows that methods to decompose iron pentacarbonyl must be quantitative to obtain accurate isotope values.  相似文献   

8.
An on-line Hg reduction technique using stannous chloride as the reductant was applied for accurate and precise mercury isotope ratio determinations by multi-collector (MC)-ICP/MS. Special attention has been paid to ensure optimal conditions (such as acquisition time and mercury concentration) allowing precision measurements good enough to be able to significantly detect the anticipated small differences in Hg isotope ratios in nature. Typically, internal precision was better than 0.002% (1 RSE) on all Hg ratios investigated as long as approximately 20 ng of Hg was measured with a 10-min acquisition time. Introducing higher amounts of mercury (50 ng Hg) improved the internal precision to <0.001%. Instrumental mass bias was corrected using 205Tl/203Tl correction coupled to a standard-sample bracketing approach. The large number of data acquired allowed us to validate the consistency of our measurements over a one-year period. On average, the short-term uncertainty determined by repeated runs of NIST SRM 1641d Hg standard during a single day was <0.006% (1 RSD) for all isotope pairs investigated (202Hg/198Hg, 202Hg/199Hg, 202Hg/200Hg, and 202Hg/201Hg). The precision fell to <0.01% if the long-term reproducibility, taken over 11 months (over 100 measurements), was considered. The extent of fractionation has been investigated in a series of sediments subject to various Hg sources from different locations worldwide. The ratio 202Hg/198Hg expressed as δ values (per mil deviations relative to NIST SRM 1641d Hg standard solution) displayed differences from +0.74 to −4.00‰. The magnitude of the Hg fractionation per amu was constant within one type of sample and did not exceed 1.00‰. Considering all results (the reproducibility of Hg standard solutions, reference sediment samples, and the examination of natural samples), the analytical error of our δ values for the overall method was within ±0.28‰ (1 SD), which was an order of magnitude lower than the extent of fractionation (4.74‰) observed in sediments. This study confirmed that analytical techniques have reached a level of long-term precision and accuracy that is sufficiently sensitive to detect even small differences in Hg isotope ratios that occur within one type of samples (e.g., between different sediments) and so far have unequivocally shown that Hg isotope ratios in sediments vary within approximately 5‰.  相似文献   

9.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

10.
A novel analytical technique for isotopic analysis of dissolved and particulate iron (Fe) from various marine environments is presented in this paper. It combines coprecipitation of dissolved Fe (DFe) samples with Mg(OH)2, and acid digestion of particulate Fe (PFe) samples with double pass chromatographic separation. Isotopic data were obtained using a Nu Plasma MC-ICP-MS in dry plasma mode, applying a combination of standard-sample bracketing and external normalization by Cu doping. Argon interferences were determined prior to each analysis and automatically subtracted during analysis. Sample size can be varied between 200 and 600 ng of Fe per measurement and total procedural blanks are better than 10 ng of Fe. Typical external precision of replicate analyses (1S.D.) is ±0.07‰ on δ56Fe and ±0.09‰ on δ57Fe while typical internal precision of a measurement (1S.E.) is ±0.03‰ on δ56Fe and ±0.04‰ on δ57Fe. Accuracy and precision were assured by the analysis of reference material IRMM-014, an in-house pure Fe standard, an in-house rock standard, as well as by inter-laboratory comparison using a hematite standard from ETH (Zürich). The lowest amount of Fe (200 ng) at which a reliable isotopic measurement could still be performed corresponds to a DFe or PFe concentration of ∼2 nmol L−1 for a 2 L sample size. To show the versatility of the method, results are presented from contrasting environments characterized by a wide range of Fe concentrations as well as varying salt content: the Scheldt estuary, the North Sea, and Antarctic pack ice. The range of DFe and PFe concentrations encountered in this investigation falls between 2 and 2000 nmol L−1 Fe. The distinct isotopic compositions detected in these environments cover the whole range reported in previous studies of natural Fe isotopic fractionation in the marine environment, i.e. δ56Fe varies between −3.5‰ and +1.5‰. The largest fractionations were observed in environments characterized by redox changes and/or strong Fe cycling. This demonstrates the potential use of Fe isotopes as a tool to trace marine biogeochemical processes involving Fe.  相似文献   

11.
Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solution has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4.5 M HCl during 25 min ultrasound exposure time. Due to the complex matrix of this fly ash material, a two-step purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10.11 ± 0.55 and 10.50 ± 0.64 μmol g−1) are comparable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference materials certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of samples.  相似文献   

12.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

13.
A robust method allowing the routine determination of n(87Sr)/n(86Sr) with at least five significant decimal digits for large sets of mineral water samples is described. It is based on 2 consecutive chromatographic separations of Sr associated to multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) measurements. Separations are performed using commercial pre-packed columns filled with “Sr resin” to overcome isobaric interferences affecting the determination of strontium isotope ratios. The careful method validation scheme applied is described. It included investigations on all parameters influencing both chromatographic separations and MC-ICPMS measurements, and also the test on a synthetic sample made of an aliquot of the NIST SRM 987 certified reference material dispersed in a saline matrix to mimic complex samples. Correction for mass discrimination was done internally using the n(88Sr)/n(86Sr) ratio. For comparing mineral waters originating from different geological backgrounds or identifying counterfeits, calculations involved the well known consensus value (1/0.1194) ± 0 as reference. The typical uncertainty budget estimated for these results was 40 ‘ppm’ relative (k = 2). It increased to 150 ‘ppm’ (k = 2) for the establishment of stand alone results, taking into account a relative difference of about 126 ‘ppm’ systematically observed between measured and certified values of the NIST SRM 987. In case there was suspicion of a deviation of the n(88Sr)/n(86Sr) ratio (worst case scenario) our proposal was to use the NIST SRM 987 value 8.37861 ± 0.00325 (k = 2) as reference, and assign a typical relative uncertainty budget of 300 ‘ppm’ (k = 2). This method is thus fit for purpose and was applied to eleven French samples.  相似文献   

14.
We developed an ion trap — laser cooling system for observing the laser induced fluorescence (LIF) of a single ion, in the view of utilizing it for the trace isotope analysis of Ca. We observed stepwise LIF signals, which correspond to the numbers of trapped 40Ca+ ions (40Ca/Ca = 96.9%). The detection efficiency was evaluated and the observation of single ions demonstrated the experimental feasibility of trace isotope analysis. Furthermore, as the next step towards trace isotope analysis, we report observation of the even calcium isotopes, 44Ca (44Ca/Ca = 2.09%) and 48Ca (48Ca/Ca = 0.187%), without the use of a selective loading method.  相似文献   

15.
Nitrogen and hydrogen isotope effects for the reaction of N-tert-butyl-P-phenylphosphonamidothioic acid 1 with alcohols (methanol, butanol, iso-propanol, tert-butanol) were measured in dichloromethane at 30 °C. The observed nitrogen isotope effect k14/k15 is only slightly sensitive to a steric hindrance of the alcohol [1.0070 ± 0.0002 (MeOH), 1.0074 ± 0.0004 (BuOH), 1.0062 ± 0.0004 (PriOH), 1.0087 ± 0.0007 (ButOH)]. The pre-equilibrium step, with proton transfer from oxygen to nitrogen was proved by the inverse hydrogen effect kROH/kROD[0.778 ± 0.052 (MeOH), 0.863 ± 0.063 (BuOH), 0.883 ± 0.080 (PriOH), 0.746 ± 0.084 (ButOH)]. The experimental values are consistent with theoretical results of semiempirical calculations on PM3 level for an elimination-addition mechanism and metathiophosphonate PhPSO intermediacy. For the reaction with methanol the addition-elimination mechanism is also possible.  相似文献   

16.
The effects and benefits of N2 addition to the central channel of the ICP through the nebulizer gas used in ICP OES with axial view configuration were investigated in the present study. The N2 flow rate, nebulizer gas flow rate, RF power and sample uptake rate were evaluated and compared for two sample introduction systems (pneumatic nebulization/aerosol desolvation and conventional pneumatic nebulization). It was observed that N2 did not affect solution nebulization and aerosol transport but affects the ICP characteristics. The higher thermal conductivity of N2 (in comparison with Ar) changes energy distribution in the ICP, observed by monitoring the signals of Ar emission lines and sodium emission. The ratio Mg(II)-280.270 nm/Mg(I)-285.213 nm was utilized as a diagnostic tool for plasma robustness. The addition of N2 (20 mL min−1) increased plasma robustness significantly and mitigated effects caused by Na, K and Ca. For 40 spectral lines evaluated, it was observed that the emission signals of ionic spectral lines were in general more affected by N2 than those of atomic spectral lines. Detection limits, precision, sensitivity and linearity of calibration curves obtained using N2-Ar-ICP were almost similar to those obtained using Ar-ICP. The analysis of 5 different reference materials revealed that accuracy was not degraded by adding N2 to the Ar-ICP.  相似文献   

17.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials.  相似文献   

18.
A new method for quantification of spectral interferences based on analyte isotope ratio measurements in the presence of various concentrations of a specific matrix is presented. Within the method, a tolerance level is used, defined as the matrix concentration at which the ratio between analyte isotopes with and without interferences is altered by 10% compared to a pure water reference standard, normalized with respect to the analyte concentration in the solutions. This can be used to estimate the lowest analyte concentration which can be determined with a defined accuracy in the presence of a known concentration of a specific matrix. Regarding spectroscopic interference effects, comparative results for sample introduction into the ICP–MS by electrothermal vaporization, ETV, and nebulization are presented for common matrix — (Ca, Na, K, Cl, P, O) and analyte (Cr, Ni, Cu, As, Se) elements. With the exception of the spectral overlap of 31P2+ on 62Ni+, spectroscopic interferences were reduced by 1–2.5 orders of magnitude when using ETV for sample introduction. Reasons for the increase in the spectral interference of 31P2+ on 62Ni+ are discussed. For sample introduction by nebulization, it was found that spectral interferences from CaO+ on 58Ni+ and 60Ni+ were reduced in the presence of phosphate.  相似文献   

19.
An improved technique for precise and accurate determination of boron isotopic composition in Na-rich natural waters (groundwater, seawater) and marine biogenic carbonates was developed. This study used a ‘micro-sublimation’ technique to separate B from natural sample matrices in place of the conventional ion-exchange extraction. By adjusting analyte to appropriate pH, quantitative recovery of boron can be achieved (>98%) and the B procedural blank is limited to <8 pg. An additional mass bias effect in MC-ICP-MS was observed which could not be improved via the standard-sample-standard bracketing or the ‘pseudo internal’ normalization by Li. Therefore a standard other than NBS SRM 951 was used to monitor plasma condition in order to maintain analytical accuracy. An isotope cross-calibration with results from TIMS shows that the space-charge mass bias on MC-ICP-MS can be successfully corrected using off-line mathematical manipulation. Several reference materials, including the seawater IAPSO and two groundwater standards IAEA-B-2 and IAEA-B-3, were used to validate this approach. We found that the δ11B of the reference coral JCp-1 was 24.22 ± 0.28‰, corresponding to seawater pH based on the coral δ11B-pH function.  相似文献   

20.
A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO4) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l−1) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000™ or an API 3200™ mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio (35Cl/37Cl) was used as a confirmation tool. The transition of 35Cl16O4 (m/z 98.9) into 35Cl16O3 (m/z 82.9) was monitored for quantifying the main analyte; the transition of 37Cl16O4 (m/z 100.9) into 37Cl16O3 (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of 35Cl/37Cl; and the transition of 35Cl18O4 (m/z 107.0) into 35Cl18O3 (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l−1 (ppt) using the API 2000™ mass spectrometer and 0.5 ng l−1 using the API 3200™ mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l−1 to 463.5 ± 6.36 μg kg−1 using MRM 98.9 → 82.9 and 100 μl injection.  相似文献   