首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective, sensitive, rapid and reliable method based on molecularly imprinted polymers (MIPs) with dual templates to determine total content of parabens in cosmetics was developed. With methylparaben (MP) and propylparaben (PP) as dual-templates, methacrylic acid (MAA) as a functional monomer and tripropylene glycol diacrylate (TPGDA) as a cross-linker, MIPs film on a glassy carbon electrode was constructed as paraben sensor. At oxidation potential of 0.94 V (vs. SCE), the peak currents on the MIPs sensor were proportional to the concentration of parabens with square wave voltammetry. As the ratio of MP to PP in the MIPs was 1:1.25, the regression equations for four parabens were almost the same. The linear range was 20-100 μM for MP and EP, 5-100 μM for PP, and 5-80 μM for BP, with detection limit of 0.4 μM for MP and EP, 0.2 μM for the others. The total content of parabens could be calculated according to the average of these four regress equations. At least 10 times of structural analogs, such as p-hydroxybenzoic acid, p-aminobenzoic acid and phenol would not interfere with the determination of parabens. Nonanalogous coexistences such as vitamin C had no response on the sensor at all. Rapid response of the MIPs sensor was obtained within 1 min. MIPs sensor had been used to determine total content of parabens in cosmetic samples with recoveries between 98.7% and 101.8%. It reveals that the MIPs sensor with multi-templates has a potential to determine the total content of a group of homologous compounds.  相似文献   

2.
A new type of tryptophan-functionalized graphene nanocomposite (Trp-GR) was synthesized by utilizing a facile ultrasonic method via ππ conjugate action between graphene (GR) and tryptophan (Trp) molecule. The material as prepared had well dispersivity in water and better conductivity than pure GR. The surface morphology of Trp-GR was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. The electrochemical behaviors of ascorbic acid (AA), dopamine (DA), and uric acid (UA) were investigated by cyclic voltammetry (CV) on the surface of Trp-GR. The separation of the oxidation peak potentials for AA–DA, DA–UA and UA–AA was about 182 mV, 125 mV and 307 mV, which allowed simultaneously determining AA, DA, and UA. Differential pulse voltammetery (DPV) was used for the determination of AA, DA, and UA in their mixture. Under optimum conditions, the linear response ranges for the determination of AA, DA, and UA were 0.2–12.9 mM, 0.5–110 μM, and 10–1000 μM, with the detection limits (S/N = 3) of 10.09 μM, 0.29 μM and 1.24 μM, respectively. Furthermore, the modified electrode was investigated for real sample analysis.  相似文献   

3.
以辛基酚(4-OP)为模板分子,多巴胺为功能单体,采用电聚合技术在磁性石墨烯修饰碳电极表面制备对辛基酚具有高选择性与灵敏性的印迹电化学传感器。采用循环伏安法(CV)和差分脉冲伏安法(DPV)对此印迹传感器的电化学性能进行详细表征;采用扫描电子显微技术对修饰电极的形貌进行表征。结果表明,此印迹电化学传感器对辛基酚具有良好的特异识别性能。采用 DPV 法考察了孵化时间和洗脱溶剂对印迹传感器性能影响,结果表明,最佳孵化时间为14 min。此印迹电化学传感器的响应电流(△IR )与辛基酚在5.0×10-6~5.0×10-9 mol/ L 范围内浓度的负对数(-lgC)呈良好的线性关系,线性方程为△IR ( mA)=-0.25lgC(mol/ L)+2.35,检出限为3.64×10-10 mol/ L (S/ N=3)。此印迹电化学传感器对辛基酚具有良好的选择性和灵敏性,成功用于实际水样中辛基酚的检测,回收率为96.0%~104.0%。  相似文献   

4.
A nitrogen-doped graphene/carbon nanotubes (NGR–NCNTs) nanocomposite was employed into the study of the electrochemical sensor via electrodeposition for the first time. The morphology and structure of NGR–NCNTs nanocomposite were investigated by scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. Meanwhile, the electrochemical performance of the glassy carbon electrode (GCE) modified with electrodeposited NGR–NCNTs (ENGR–NCNTs/GCE) towards caffeine (CAF) and vanillin (VAN) determination was demonstrated by cyclic voltammetry (CV) and square wave voltammetry (SWV). Under optimal condition, ENGR–NCNTs/GCE exhibited a wide linearity of 0.06–50 μM for CAF and 0.01–10 μM for VAN with detection limits of 0.02 μM and 3.3 × 10−3 μM, respectively. Furthermore, the application of the proposed sensor in food products was proven to be practical and reliable. The desirable results show that the ENGR–NCNTs nanocomposite has promising potential in electrocatalytic biosensor application.  相似文献   

5.
The combination of coumarin derivative (7-(1,3-dithiolan-2-yl)-9,10-dihydroxy-6H-benzofuro[3,2-c]chromen-6-on), (DC)–titanium dioxide nanoparticles (TiO2) and ionic liquid (IL) yields nanostructured electrochemical sensor, formed a novel kind of structurally uniform and electrocatalytic activity material. This new ionic liquid–TiO2 nanoparticles modified carbon paste electrode (IL–CTP) due to its enhanced conductivity presented very large current response from electroactive substrates. The modified electrode was characterized by different methods including a scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS) and voltammetry. A pair of well-defined quasi reversible redox peaks of coumarin derivative was obtained at the modified carbon paste electrode (DC/IL–CTP) by direct electron transfer between the coumarin derivative and the CP electrode. Dramatically enhanced electrocatalytic activity was exemplified at the DC/IL–CTP electrode, as an electrochemical sensor to study the electro oxidation of levodopa (LD) and carbidopa (CD). Based on differential pulse voltammetry (DPV), the oxidation of LD and CD exhibited the dynamic range between 0.10– 900.0 μM and 20.0–900.0 μM respectively, and the detection limit (3σ) for LD and CD were 41 nM and 0.38 μM, respectively. DPV was used for simultaneous determination of LD and CD at the DC/IL–CTP electrode, and quantitation of LD and CD in some real samples (such as tablets of Parkin-C Fort and Madopar, Sinemet, water, urine, and human blood serum) by the standard addition method.  相似文献   

6.
A glassy carbon electrode modified with poly(alizarin red)/electrodeposited graphene (PAR/EGR) composite film was prepared and applied to detect ciprofloxacin (CPFX) in the presence of ascorbic, uric acid and dopamine. The morphology and interface property of PAR/EGR films were examined by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electrocatalytic oxidation of CPFX on AR/EGR was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linearity ranged from 4 × 10−8 to 1.2 × 10−4 M with a detection limit (S/N = 3) of 0.01 μM. The modified electrode could be applied to the individual determination of CPFX as well as the simultaneous determination of CPFX, ascorbic acid, uric acid and dopamine. This method proved to be a simple, selective and rapid way to determine CPFX in pharmaceutical preparation and biological media.  相似文献   

7.
基于石墨烯分子印迹电化学传感器测定芦丁   总被引:2,自引:0,他引:2  
将石墨烯(GR)滴涂至裸Au电极表面,并以邻氨基酚为功能单体,芦丁为模板分子,制备了芦丁分子印迹膜电化学传感器,利用循环伏安法(CV)和差分脉冲伏安法(DPV)对制得的传感器进行了电化学性能研究,并且对制备条件和测定条件进行了优化。结果表明,与裸Au电极相比,该GR修饰的Au电极在[Fe(CN)_6]~(3-/4-)溶液中峰电流明显增大,显著提高了芦丁分子印迹传感器的灵敏度。在最优实验条件下,基于GR分子印迹电化学传感器在4.40×10~(-6)~2.80×10~(-4) mol/L范围内呈良好的线性关系,检测限为1.46×10~(-6) mol/L。用该传感器测定了黑茶中芦丁的含量,获得较好结果。  相似文献   

8.
In this study, a novel material for the electrochemical determination of 17β-estradiol using an electrode based on reduced graphene oxide and a metal complex porphyrin has been applied to environmental monitoring. The electrochemical profile of the proposed electrode was analyzed by differential pulse voltammetry, which showed a shift of the oxidation peak potential of 17β-estradiol to 150 mV in a less positive direction compared to the bare reduced graphene oxide electrode. DPV experiments were performed in PBS at pH 7.0 to determine 17β-estradiol without any previous step of extraction, cleanup, or derivatization, in the range of 0.1–1.0 μmol L−1 with a detection limit archived at 5.3 nmol L−1 (1.4 μg L−1). The proposed sensor was successfully applied in the determination of 17β-estradiol in a river water sample without any purification step and was successfully analyzed under the standard addition method. All the obtained results were in agreement with those from the HPLC procedure.  相似文献   

9.
Here we demonstrate for the first time that by physically adsorbing aptamer onto conductive film assembled via alternate adsorption of graphene/polyelectrolyte and methylene blue/polyelectrolyte, a label-free electrochemical aptasensor with high sensitivity and selectivity for peptide detection is constructed. Graphene multilayer derived from layer-by-layer assembly has played significant roles in this sensing strategy: allowing accumulation of methylene blue, facilitating electron transfer and providing much more adsorption site. As compared to previous electrochemical aptasensors, the current sensor based on graphene multilayer alternated with electroactive molecule layer offers extremely high capability for sensitive detection of target without interference of environmental surrounding. This electroactive probe-confined graphene multilayer confers great flexibility to combine with differential pulse voltammetry (DPV) together. In the presence of target d entiomer of arginine vasopressin (d-VP), the binding of peptide to aptamer block the electron transfer process of MB, leading to decreased current peak of DPV. By this way, this electrochemical aptasensor based on electroactive molecule-intercalated graphene multilayer provide highly sensitive and specific detection of d-VP with the lowest detectable concentration of 1 ng mL−1 and a wide detection range from 1 to 265 ng mL−1.  相似文献   

10.
The reduction of 4-nitrophenol (4-NP) has been carried out on a modified glassy carbon electrode using cyclic and differential pulse voltammetry (DPV). The sensor was prepared by modifying the electrode with lithium tetracyanoethylenide (LiTCNE) and poly-l-lysine (PLL) film. With this modified electrode 4-NP was reduced at −0.7 V versus SCE. The sensor presented better performance in 0.1 mol l−1 acetate buffer at pH 4.0. The other experimental parameters, such as concentration of LiTCNE and PLL, pulse amplitude and scan rate were optimized. Under optimized operational conditions, a linear response range from 27 up to 23200 nmol l−1 was obtained with a sensitivity of 3.057 nA l nmol−1 cm−2. The detection limit for 4-NP determination was 7.5 nmol l−1. The proposed sensor presented good repeatability, evaluated in term of relative standard deviation (R.S.D.=4.4%) for n=10 and was applied for 4-NP determination in water samples. The average recovery for these samples was 103.0 (± 0.7)%.  相似文献   

11.
In this research, the graphene with excellent dispersity is prepared successfully by introducing gold nanoparticle to separate the individual sheets. Various techniques are adopted to characterize the prepared graphene and graphene-gold nanoparticle composite materials. This fabricated new composite material is used as the support material to construct a novel tyrosinase based biosensor for detection of bisphenol A (BPA). The electrochemical performances of the proposed new enzyme biosensor were investigated by differential pulse voltammetry (DPV) method. The proposed biosensor exhibited excellent performance for BPA determination with a wide linear range (2.5 × 10−3–3.0 μM), a highly reproducible response (RSD of 2.7%), low interferences and long-term stability. And more importantly, the calculated detection limit of the proposed biosensor was as low as 1 nM. Compared with other detection methods, this graphene-gold nanoparticle composite based tyrosinase biosensor is proved to be a promising and reliable tool for rapid detection of BPA for on-site analysis of emergency BPA related pollution affairs.  相似文献   

12.
A novel molecularly imprinted electrochemical sensor based on Fe3O4 nanobeads immobilized on graphene (Fe3O4-MIP@RGO) has been developed for detecting 17β-estradiol (17β-E2) in water using reversible addition fragmentation chain transfer (RAFT) polymerization technique. 17β-E2 can be detected by this electrochemical sensor through the response current change before and after binding 17β-E2. The Fe3O4-MIP@RGO-based sensor amplifies the response current in differential pulse voltammetry measurement, allowing the detection limit reaching 0.819 nM in a wide linear range from 0.05 to 10 μM. Moreover, Fe3O4-MIP@RGO-based sensor exhibits high selectivity and sensitivity towards 17β-E2. This MIP electrochemical sensor has a promising potential in the detection of 17β-E2 in water.  相似文献   

13.
A Nafion-graphene (Nafion-GR) nanocomposite film modified glassy carbon electrode was fabricated by a simple drop-casting method, and used in the electrochemical detection of p-aminophenol (4-AP). Owing to the large surface area, good conductivity of GR and good affinity of Nafion, the sensor exhibited excellent electrocatalytic activity for the oxidation of 4-AP. The electrochemical behaviors of 4-AP on Nafion/GR film modified glassy carbon electrodes were investigated by cyclic voltammetry and differential pulse voltammetry. A calibration curve is constructed in the same matrix, urine, as the unknown samples to be analyzed. The Nafion-GR film modified electrode was linearly dependent on the 4-AP concentration and the linear analytical curve was obtained in the ranges of 0.5–200 μM with differential pulse voltammetry (DPV) and the detection limit was 0.051 μM. The Nafion-graphene nanocomposite modified electrode exhibited good reusability than pure graphene modified GCE. This procedure can be used for the determination of p-aminophenol in the presence of its degradation products and paracetamol. Finally, the proposed method was successfully used to determine p-aminophenol in local tap water samples in urine samples and pharmaceutical preparations.  相似文献   

14.
p-Nitrophenyl organophosphates (OPs) including paraoxon, parathion and methyl parathion, etc, are highly poisonous OPs, for which sensitive and rapid detection method is most needed. In this work, an ultrasensitive electrochemical sensor for the determination of p-nitrophenyl OPs was developed based on ordered mesoporous carbons (OMCs) modified glassy carbon electrode (GCE) (OMCs/GCE). The electrochemical behavior and reaction mechanism of p-nitrophenyl OPs at OMCs/GCE was elaborated by taking paraoxon as an example. Experimental conditions such as buffer pH, preconcentration potential and time were optimized. By using differential pulse voltammetry, the current response of the sensor at −0.085 V was linear with concentration within 0.01–1.00 μM and 1.00–20 μM paraoxon. Similar linear ranges of 0.015–0.5 μM and 0.5–10 μM were found for parathion, and 0.01–0.5 μM and 0.5–10 μM for methyl parathion. The low limits of detection were evaluated to be 1.9 nM for paraoxon, 3.4 nM for parathion and 2.1 nM for methyl parathion (S/N = 3). Common interfering species had no interference to the detection of p-nitrophenyl OPs. The sensor can be applicable to real samples measurement. Therefore, a simple, sensitive, reproducible and cost-effective electrochemical sensor was proposed for the fast direct determination of trace p-nitrophenyl OPs at low potential without deoxygenization.  相似文献   

15.
建立了一种循环伏安法制备CuNi/β-环糊精/还原氧化石墨烯修饰玻碳电极(CuNi/β-CD/ERGO/GCE)的方法。通过多巴胺在该修饰电极上的电化学行为发现,该电化学传感器实现了快速、灵敏的测定多巴胺。该传感器用差分脉冲伏安法(DPV)测定多巴胺时,其电化学响应电流与多巴胺浓度在0.01~20μmol/L之间呈线性关系,检测限为8 nmol/L。该传感器用于尿液样品中的多巴胺检测,回收率在95.6%~107.2%之间。  相似文献   

16.
A novel one-step approach to glassy carbon nanoelectrode ensembles (NEEs) with the pores of 20-120 nm in radii has been developed using an amphiphilic block copolymer [polystyrene-block-poly (acrylic acid)] self-assembly. This procedure is simple and fast, and requires only conventional, inexpensive electrochemical instrumentation. Electrochemical methods were used to characterize the NEEs prepared using this new procedure. The NEEs drastically suppressed the response of ascorbic acid (AA) and resolved the overlapping voltammetric response of uric acid (UA) and AA into two well-defined peaks with a large anodic peak difference (ΔEpa) of about 310 mV. The peak current obtained from differential pulse voltammetry (DPV) was linearly dependent on the UA concentration in the range of 0.25-50 μM at neutral pH (PBS, pH 6.86) with a correlation coefficient of 0.999, and the detection limit was 0.04 μM (S/N = 3). The NEEs has also been demonstrated to be applicable in the detection of UA in serum and urine samples with excellent sensitivity and selectivity. The NEEs will hopefully be of good application for further sensor development.  相似文献   

17.
Nanocrystalline graphite-like pyrolytic carbon film (PCF) electrode fabricated by a non-catalytic chemical vapor deposition (CVD) process was used for the simultaneous electrochemical sensing of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electrode was studied with respect to changes in electrocatalytic activity caused by a simple and fast electrochemical pretreatment. The anodized electrode exhibited excellent performance compared to many chemically modified electrodes in terms of detection limit, linear dynamic range, and sensitivity. Differential pulse voltammetry (DPV) was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Under optimum conditions, the detection limits were 2.9 μM for AA, 0.04 μM for DA, and 0.03 μM for UA with sensitivities of 0.078, 5.345, and 6.192 A M−1, respectively. The peak separation was 219 mV between AA and DA and 150 mV between DA and UA. No electrode fouling was observed and good reproducibility was obtained in all the experiments. The sensor was successfully applied for the assay of DA in an injectable drug and UA in human urine by using standard addition method.  相似文献   

18.
Here, an electrochemical detection approach (differential pulse voltammetry) was employed to develop a 2-nitrophenol (2-NP) sensor probe using a glassy carbon electrode (GCE) coated by wet-chemically synthesized nanorods (NRs) of BaO. The prepared BaO NRs were characterized by field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and powder X-ray diffraction (XRD) analysis. The peak currents by differential pulse voltammetric (DPV) analysis of 2-NP are plotted against the concentration to obtain the calibration curve of the 2-NP detection. It was found to be linear from 1.5 to 9.0 μM, defined as the dynamic range (LDR) for 2-NP detection in phosphate buffer solution. The sensor sensitivity was calculated from the slope of LDR by considering the active surface area of NRs coated on GCE (0.0316 cm2) and found as 17.6 μAμM−1 cm−2. The limit of detection (LOD) was calculated as 0.50±0.025 μM from the signal/noise (S/N) ratio of 3. Moreover, the sensor analytical parameters such as reproducibility, long-term performing ability (stability), response time and validity in real environmental samples were found acceptable and to give satisfactory results. The development of a nanomaterial-based electrochemical chemical sensor might be an effective approach to sensor technology to detect carcinogenic and hazardous toxins for environmental safety and healthcare fields in a broad scale.  相似文献   

19.
In this work, a very sensitive and simple electrochemical sensor for chlorophenols (CPs) based on a nanocomposite of cetyltrimethylammonium bromide (CTAB) and ZnSe quantum dots (ZnSe–CTAB) through electrostatic self-assembly technology was built for the first time. The composite of ZnSe–CTAB introduced a favorable access for the electron transfer and gave superior electrocatalytic activity for the oxidation of CPs than ZnSe QDs and CTAB alone. Differential pulse voltammetry (DPV) was used for the quantitative determination of the CPs including 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP) and pentachlorophenol (PCP). Under the optimum conditions, the peak currents of the CPs were proportional to their concentrations in the range from 0.02 to 10.0 μM for 2-CP, 0.006 to 9.0 μM for 2,4-DCP, and 0.06 to 8.0 for PCP. The detection limits were 0.008 μM for 2-CP, 0.002 μM for 2,4-DCP, and 0.01 μM for PCP, respectively. The method was successfully applied for the determination of CPs in waste water with satisfactory recoveries. This ZnSe–CTAB electrode system provides operational access to design environment-friendly CPs sensors.  相似文献   

20.
An effective electrochemical sensor for the rapid and simultaneous determination of tramadol and acetaminophen based on carbon paste electrode (CPE) modified with NiFe2O4/graphene nanoparticles was developed. The structures of the synthesized NiFe2O4/graphene nanocomposite and the electrode composition were confirmed by X-ray diffraction (XRD) spectrometry, Fourier transform infrared (FT-IR) spectrometry and scanning electron microscopy (SEM). The peak currents of square wave voltammetry of tramadol and acetaminophen increased linearly with their concentration in the range of 0.01–9 μmol L−1. The detection limit for their determination was found to be 0.0036 and 0.0030 μmol L−1, respectively. The results show that the combination of graphene and NiFe2O4 nanoparticles causes a dramatic enhancement in the sensitivity of the sensor. The fabricated sensor exhibited high sensitivity and good stability, and would be valuable for the clinical assay of tramadol and acetaminophen.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号