首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary An analytical procedure for the individual determination of ortho and non-ortho PCB congeners in sediments, using high performance liquid chromatography (HPLC) preseparation and gas chromatography/ECD detection, is described. Gas chromatography/FTIR spectrometry (GC/FTIR) and gas chromatography/mass spectrometry (GC/MS) were employed for individual congener identification and determination. Sample extraction, clean-up of extract and selective elution procedures were optimized by using reference certified marine sediment samples. Recovery and precision were typically 83% and 16% respectively at 2 ng/g of total PCB content. The proposed procedure, tested by analyzing real sediment samples, showed a reproducibility better than 20% at 13 ng/g PCB level.  相似文献   

2.
A method is described for the determination of the sterol, erythrodiol, uvaol and alkanol content in olive oils by means of solid-phase extraction and high-performance liquid chromatography, instead of liquid-liquid and thin-layer chromatographic separations, the following step being high-resolution gas chromatographic separation. This type of procedure allows the simultaneous analysis of a larger number of samples and a substantial reduction in manual operations. Comparisons were made between the two methods on 100 different olive oils and with a statistical analysis of the results (Student's t-test).  相似文献   

3.
A method was developed for the rapid determination of testosterone in urine. The procedure consists of solid-phase extraction (SPE) followed by high-performance liquid chromatographic (HPLC) clean-up before gas chromatographic determination. Recovery was evaluated by adding [3H]testosterone (10(4) cpm) to urine samples; the mean recovery of radioactivity after SPE and HPLC was 82%. Precision was estimated by repeated measurement of testosterone in four different urine samples; the coefficient of variation was 7.9% (95% confidence limits 6.1-11.4%). Accuracy was evaluated by standard addition and dilution assays; a linear relationship was found between the expected and observed values (r2 = 0.982). The method is rapid, effective and suitable for routine analysis.  相似文献   

4.
Summary Recent work demonstrated that the combination of microwave assisted solvent extraction (MASE) and capillary gas chromatography with selective nitrogen detection (GC-NPD) is a viable approach for the efficient determination of triazine herbicides in soils. However, for soils with a high organic matter content or the injection of more concentrated extracts to obtain lower LOD's the performance of gas chromatographic analysis of uncleaned extracts is hampered. This results in both a decrease of the chromatographic response of analytes and a decrease in the life time of the column due to coextracted matrix substances. The effect of various types of soils on the chromatographic analysis of triazine herbicides was studied. It appeared that for the investigated samples with an organic matter content below 5% processing of uncleaned extracts is possible. Samples with a higher organic matter content required a cleanup step. A rapid procedure on 100 mg silica cartridges has been developed using solvents compatible with the MASE extracts and the instrumental analysis. Beside the testing with different standard soils, about 120 samples of an ongoing monitoring program involving three different types of soil (organic matter content: 3–37%) were analysed. The selected compounds atrazine, desethylatrazine, desisopropyl-atrazine and simazine could be assayed in the various soil types to a level of at least 2 μg kg−1. For soil samples with a high organic matter content (>5%), the rapid cleanup procedure allowed the trace analysis of the triazines and considerably increased the life time of the capillary column. Recoveries at levels from 2 to 50 μg kg−1 ranged from 70 to 100% with RSDs ranging from 5.1 to 9.5%. Confirmation of positive samples was carried out by gas chromatography mass spectrometry.  相似文献   

5.
A high performance liquid chromatography (HPLC) method is described for the determination of agmatine, an endogenous neuromodulator. The method involves pre-column derivatization of the sample with a fluorescent tagging reagent, 7-fluoro-4-nitrobenzoxadiazole (NBD-F). The resulting agmatine derivative is stable and can be readily extracted into ethyl acetate at pH 8.5. The extraction enhances the quantification of low level agmatine because it eliminates chromatographic peaks caused by endogenous amino acids. The HPLC separation is carried out on a C8 reversed phase column and completed in less than 10 min. With laser-induced fluorescence (LIF) detection, the detection limit is 5×10−9 M agmatine. Method precision (coefficient of variation) is 5% for agmatine in human plasma at the sub-μM level. This method has been validated by determination of agmatine in biological samples including human plasma and rat brain and stomach tissues.  相似文献   

6.
A sensitive and selective high-performance capillary electrophoresis (HPCE) procedure was developed for the determination of total cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using sodium dodecyl sulphate in the run buffers and ultraviolet detection. The concentrations of cicletanine obtained by this method were compared with those obtained by a high-performance liquid chromatographic (HPLC) method used routinely. The within-run precision of the methods, expressed as relative standard deviation, ranged from 1.6 to 7.8% for HPLC and from 6.4 to 11.1% for HPCE. Both methods showed an adequate level of accuracy; the relative errors ranged from 0.02 to 3.25% for HPLC and from 0.21 to 2.90% for HPCE. The HPCE method required less than half the time taken by the HPLC method, making HPCE a useful alternative technique for the routine determination of cicletanine in plasma. Both methods were used to follow the time course of total cicletanine in human plasma after a single oral therapeutic dose of the drug.  相似文献   

7.
This paper reports the development of a highly selective and sensitive method for the determination of parts-per-billion level of 1,3-dichloropropan-2-ol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in soy sauce using capillary gas chromatography with mass spectrometric detection. Samples were homogenised, mixed with sodium chloride solution and then adsorbed on silica gel. The loaded silica gel was packed into a chromatographic column, from which chloropropanols were extracted by elution with ethyl acetate. Heptafluorobutyric acid anhydride was added to the concentrated eluant to derivatise the chloropropanols and the derivatised analytes were separated by gas chromatography, identified and quantified by mass spectrometry. A linear relationship between the concentration of the two chloropropanols and the detector response was obtained over the concentration range of 10-1000 microg/kg. Precision of the method was satisfactory at about 5%, and recoveries of 1,3-DCP and 3-MCPD from soy sauce samples spiked at 25 microg/kg were 77 and 98%, respectively. The limit of quantitation of the method was found to be about 5 microg/kg for 1,3-DCP and 3-MCPD, respectively meeting the requirements of tolerance limits adopted by different international institutions and governments around the world. This paper is the first of its kind in reporting an analytical procedure for the simultaneous separation and determination of 3-MCPD and 1,3-DCP, a more potent contaminant, at low microg/kg level.  相似文献   

8.
An innovative procedure for the on-line coupling of ion chromatography with graphite furnace atomic absorption spectrometry is described, which is particularly effective for the determination of trace metals in seawater samples. The Capillary Injection Device (CID) is used as an interface which allows the eluent to be transferred from the chromatographic column into the graphite tube at a flow rate of as high as 2 ml/min. The analytical procedure is based on the metal complex formation with 8-hydroxyquinoline in the sample solution, followed by the preconcentration of the complexes in a chromatographic column packed with XAD-2 resin. The complexes were then eluted from the column with methanol, and quantitatively injected into the furnace. The procedure was validated by determining cadmium and lead in certified reference seawater samples at a level of 30–40 pg/g, with a typical reproducibility of 10% and an accuracy of better than 5%. Finally, it was tested on a real sample of seawater. Due to the high reproducibility, a pg/g concentration level can be measured.  相似文献   

9.
Zhang C  Wang H  Zhang X  Ma Z  Deng W  Hu K  Ding M 《色谱》2011,29(12):1236-1239
建立了油脂食品(方便面、油炸糕点、沙琪玛、食用油等)中5种主要邻苯二甲酸酯类增塑剂的凝胶渗透色谱(GPC)净化-高效液相色谱(HPLC)分析方法。食品样品用石油醚超声提取,经GPC净化后,采用反相HPLC进行分析。所用的分离柱为Labtech C18(250 mm×4.6 mm, 5 μm),以乙腈和水为流动相,梯度洗脱。方法的相关系数皆在0.997以上,目标物的检出限(信噪比为3计)为3.25~13.4 μg/L。在50 mg/L添加水平时,目标物的加标回收率为70.4%~113.6%,相对标准偏差为0.3%~5.8%(n=3)。该方法简便、快捷、实用,可用于油脂食品中邻苯二甲酸酯类增塑剂的分析测定。  相似文献   

10.
A new method for determination of pyrethroids, pyrethrins, and piperonyl butoxide (PBO) by high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was developed for aquatic sediments. The method detection limits for pyrethroids (15 compounds), pyrethrins, and PBO ranged from 0.16 to 1.50 ng/g sediment, which was suitable for detecting these chemicals at environmentally relevant concentrations (low ng/L range) that are toxicologically significant to benthic organisms. Recovery of the analytes from a low level spiked sediment ranged from 89.7% to 135%. Resmethrin showed the lowest recovery at 23.5% and pyrethrins showed the highest recovery at 154%. To confirm the utility of this new method for environmental applications, sediment samples collected from five tributaries of the San Francisco Bay, California were analyzed. Individual pyrethroids were detected in concentrations of up to 17.6 ng/g, while PBO was detected in all sediment samples in concentrations of 0.010-0.215 ng/g. Pyrethrins were not found in the sediment samples.  相似文献   

11.
Summary Analytical protocols have been adapted for the study of hydrocarbons at the trace level in the environment. Various samples, including sediments and biota, were collected from the Kuwaiti environment, treated according to the protocol and analyzed by chromatographic and spectroscopic methods. The methods used were synchronous scanning fluorescence spectroscopy (SSFS); high-performance liquid chromatography (HPLC) on C18 reversed-phase and NH2 normal-phase columns with UV and fluorescence detectors; gas chromatography on fused-silica capillary columns (GC) with flame ionization detector (FID), mass spectrometer (MS) and flame photometric detector (FPD); and high-resolution molecular spectrofluorimetry in Shpol'skii matrix at 10 K (HRSS). The different methods were found to give complementary information. SSFS was useful for fast evaluation and preliminary assessment of oil pollution during extended programs; it permitted sample selection for deeper analyses but, when applied to biota, needed special care in the clean-up procedure. GC/FID, was used to analyze saturated and ethylenic compounds and was useful for obtaining information on the origin of hydrocarbons but inconvenient for analyzing the aromatic fraction. GC/FPD was difficult to use with sediment samples and yielded little information on biota samples, although it did permit confirmation of high oil contamination in some examples. HPLC on a normal-phase column with UV and fluorescence detectors was useful for the fractionation of samples and for the separation of different families of aromatic compounds according to aromatic carbon number. GC/MS was used to quantify polycyclic aromatic hydrocarbons (PAHs) of less than four cycles but was not sensitive enough for PAHs of higher molecular weight. HRSS, however, was useful for the quantification of heavy PAHs and was also faster, could be automated, and gave accurate results. However, in an oil-pollution study, it must be backed up by the other techniques. In fact, no single analytical technique was found to be sufficient, and only judicious combinations of the tested techniques yielded adequate information on the origin of hydrocarbons in the environment.  相似文献   

12.
A complete methodology, incorporating a novel clean-up technique, for quantitative determination of amino acids in plasma by gas chromatography is described. Glucose, a component causing major analytical interference, is removed by an enzymic reaction included in the pre-chromatographic clean-up. The procedure for derivatisation of amino acid standards is shown to be reproducible down to a level of 2.5 micrograms for each amino acid, relative standard deviations for all amino acids except arginine and histidine being 3% or lower. For the entire procedure applied to plasma, relative standard deviations for most amino acids are below 5% with recoveries ranging from 90 to 120%. Normal values, obtained using eighteen plasma samples, are in reasonable agreement with published data. Plasma amino acid values were determined simultaneously by gas chromatographic and ion-exchange chromatographic techniques. Statistical evaluation shows there to be no significant difference between corresponding values for eleven amino acids. Values for tyrosine, histidine and particularly phenylalanine show significant differences (p less than 0.001).  相似文献   

13.
A procedure is given for the determination of methylcyclopentadienylmanganese tricarbonyl (MMT) at ng m-3 concentrations in air. The method involves trapping of MMT in a small segment of gas chromatographic column and then determination by gas chromatography with an electrothermal atomic absorption detector. The detection limit of the procedure is 0.05 ng m-3. Air samples from an underground car-park (when MMT was detected) were found to contain between 0.1 and 0.3 ng m-3 MMT. MMT was not detected in any of the street air samples taken.  相似文献   

14.
A simple, rapid, and accurate method is described for the determination of residual fluvalinate in beeswax. The procedure consists of partitioning on a disposable column of diatomaceous earth (Extrelut), followed by chromatographic cleanup on a Florisil cartridge. The final extract is analyzed by capillary gas chromatography with electron-capture detection (GC-ECD). Briefly, wax samples were dissolved in n-hexane, and the solutions were sonicated and transferred to Extrelut columns. The fluvalinate was extracted with acetonitrile, and a portion of the extract was cleaned up on a Florisil cartridge. The fluvalinate was eluted with diethyl ether-n-hexane (1 + 1) and directly determined by GC-ECD. Recoveries from wax samples spiked at 5 fortification levels (100-1500 microg/kg) ranged from 77.4 to 87.3%, with coefficients of variation of 5.12-8.31%. The overall recovery of the method was 81.4 +/- 3.2%, and the limit of determination was 100 microg/kg.  相似文献   

15.
A methodology for multi-class pesticide determination at trace level in lanolin is presented. Gel permeation chromatography on a Bio-Beads SX-3 column followed by a dual GC chromatographic determination has been developed. The effluent of the analytical column (50% diphenyl–methyl- or 14% cyanopropyl–phenylpolysiloxane) was split into an electron-capture and a nitrogen–phosphorus detection system. The chromatographic system was optimised for 28 pesticides commonly used to control sheep pests and corresponding to organochlorine, organophosphorus and pyretroid classes. Identification has been carried out by gas chromatography coupled to negative chemical ionization mass spectrometry. Recoveries ranged from 72 to 94% and the detection limits from 20 to 97 ng/g depending on the pesticide class, the RSDs were below 10%. Finally, the developed analytical methodology has been successfully applied to the determination of pesticides in several lanolin samples.  相似文献   

16.
A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub-ppb level. A micro gas-phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam distillation-extraction, and capillary gas chromatographic analysis is carried out in less than four hours.  相似文献   

17.
A selective procedure is described for the determination of amitriptyline in plasma. The method involves extraction, separation of amitriptyline from its metabolites and subsequent oxidation by ceric sulphate in 5.4 M sulphuric acid. The oxidation product, anthraquinone, is determined by means of electron-capture gas chromatography. The metabolites were separated by a column chromatographic extraction technique. The choice of oxidation reagent, optimum conditions for the oxidation, and the electron-capture properties of anthraquinone are discussed. The method can be used to determine down to 2 ng of amitriptyline in a plasma sample; the relative standard deviation at the 50-ng level was 4.0% (n = 8). The levels of amitriptyline found in a series of plasma samples are compared with those obtained by gas chromatography with use of nitrogen-specific detection; the two techniques gave coincident results.  相似文献   

18.
A novel ion chromatographic method was proposed for the simultaneous determination of artificial sweeteners (sodium saccharin, aspartame, acesulfame-K), preservatives (benzoic acid, sorbic acid), caffeine, theobromine and theophylline. The separation was performed on an anion-exchange analytical column operated at 40 degrees C within 45 min by an isocratic elution with 5 mM aqueous NaH2PO4 (pH 8.20) solution containing 4% (v/v) acetonitrile as eluent, and the determination by wavelength-switching ultraviolet absorbance detection. The detection limits (signal-to-noise ratio 3:1) for all analytes were below the sub-microg/ml level. Under the experimental conditions, several organic acids, including citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various food and pharmaceutical preparations, and the average recoveries for real samples ranged from 85 to 104%. The levels of all analytes determined by this method were in good agreement with those obtained by the high-performance liquid chromatographic procedure. The results also indicated that ion chromatography would be possibly a beneficial alternative to conventional high-performance liquid chromatography for the separation and determination of these compounds.  相似文献   

19.
Determination of aflatoxins in food products by chromatography.   总被引:1,自引:0,他引:1  
Several chromatographic methods for the determination of aflatoxins in agricultural and food products are reviewed. During the past two decades, identification and determination of aflatoxins were done by thin-layer chromatography (TLC) because it was easy, fast and inexpensive. However, high-performance liquid chromatography (HPLC) using fluorescence detection is now the method of choice for determining aflatoxins and is also growing in popularity for their identification. The reasons for selecting HPLC over TLC can be summarized as the ability to analyze for a wide variety of compounds, including compounds that are easily degraded by heat, light or air, the ease of adaptation to confirmatory procedures, the potential for automation and the dramatic improvement in instrumentation, including the development of increasingly sensitive fluorescence and electrochemical detectors and short, high-resolution, reversed-phase columns.  相似文献   

20.
A simple, selective and rapid analytical method for determination of trimethoprim (TMP) in honey samples was developed and validated. This method is based on a SPE technique followed by HPLC with photodiode array detection. After dilution and filtration, aliquots of 500 μL honey samples were directly injected to an on-line SPE HPLC system. TMP was extracted on an RP SPE column, and separated on a hydrophilic interaction chromatography column during HPLC analysis. At the first detection step, the noise level of the photodiode array data was reduced with two-dimensional equalizer filtering, and then the smoothed data were subjected to derivative spectrum chromatography. On the second-derivative chromatogram at 254 nm, the limit of detection and the limit of quantification of TMP in a honey sample were 5 and 10 ng/g, respectively. The proposed method showed high accuracy (60-103%) with adequate sensitivity for TMP monitoring in honey samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号