首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(II) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range of 4.2 x 10(-6)-1.0 x 10(-2) and 3.3 x 10(-6)-1.0 x 10(-2) M ibuprofen within pH ranges of 4-9 and 5-9 for PVC and PU matrix membranes, respectively. A sensor based on a polyurethane membrane displays a lower detection limit and a wider linear working range, and a sensor based on a PVC membrane exhibits a better overall selectivity, especially in the presence of lipophilic organic anions. Both sensors are used for the quantification and quality-control assessment of ibuprofen in pharmaceutical preparations. The average recoveries are 99.1+/-0.3% and 99.3+/-0.3% for TPP In(III)-PVC and TPP In(III)-PU based membrane sensors, respectively. High selectivities towards ibuprofen in the presence of many anions, drug excipients and diluents are offered by both sensors, which exhibit a non-Hofmeister selectivity pattern.  相似文献   

2.
Two novel potentiometric sensors that are highly selective to Hg2+ ions are described. These are based on the use of 5,5'-dithio-bis(2-nitrobenzoic acid) (DTNB) and tricyclazole (TCZ) as neutral carriers in plasticized poly(vinyl chloride) membranes. Fast Nernstian responses are obtained for Hg2+ ions over the concentration ranges 7.0 x 10(-6) - 1.0 x 10(-2) and 7.7 x 10(-6) - 1.0 x 10(-2) mol l(-1) at pH 1.8 - 3.3 with lower detection limits of 5.0 x 10(-6) and 5.6 x 10(-6) mol l(-1) (approximately 1 microh ml(-1)) and calibration slopes of 30.0 and 29.7 mV decade(-1) with DTNB- and TCZ-based membrane sensors, respectively. Validation of the assay method reveals good performance characteristics, including long life span, good selectivity for Hg2+ ions over a wide variety of other metal ions, long term response stability, and high reproducibility. Applications for direct determination of mercury in hazardous wastes including dental amalgam, mercury bulbs, and fluorescent lamps give results with good correlation with data obtained using cold vapor atomic absorption spectrometry.  相似文献   

3.
The self-assembled guanosine (G 1)-based hexadecamers and isoguanosine (isoG 2)-based decamers are excellent 226Ra2+ selective ionophores even in the presence of excess alkali (Na+, K+, Rb+, and Cs+) and alkaline earth (Mg2+, Ca2+, Sr2+, and Ba2+) cations over the pH range 3-11. G 1 requires additional picrate anions to provide a neutral assembly, whereas the isoG 2 assembly extracts 226Ra2+ cations without any such additives. Both G 1-picrate and isoG 2 assemblies show 226Ra2+ extraction even at a 0.35 x 10(6) fold excess of Na+, K+, Rb+, Cs+, Mg2+, or Ca2+ (10(-2) M) to 226Ra2+ (2.9 x 10(-8) M) and at a 100-fold salt to ionophore excess. In the case of the G 1-picrate assembly, more competition was observed from Sr2+ and Ba2+, as extraction of 226Ra2+ ceased at an M2+/226Ra2+ ratio of 10(6) and 10(4), respectively. With the isoG 2 assembly, 226Ra2+ extraction also occurred at a Sr2+/226Ra2+ ratio of 10(6) but ceased at a 10(6) excess of Ba2+. The results clearly demonstrate the power of molecular self-assembly for the construction of highly selective ionophores.  相似文献   

4.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

5.
J Yuan  Y Hu  L Nie  S Yao 《Analytical sciences》2001,17(12):1389-1393
The construction and general performance characteristics of three piezoelectric quartz crystal sensors responsive to the pentoxyverine are described here. This kind of non-potentiometric sensing method is based on use of ion-pair complexes of the pentoxyverine cation with three counter anions, namely, tungstophosphate, tetraphenylborate and picrolonate. The complexes were embedded in a PVC matrix. Adsorption of the pentoxyverine ion on the complex caused a frequency decrease of the crystal. The frequency decrease was proportional to the amount of adsorbed analyte. The influencing factors were investigated in detail, and then optimized. The proposed sensors exhibit reasonable selectivity and a higher sensitivity than the potentiometric sensors. For a sensor modified with pentoxyverine-phosphotungstate, the calibration graph was linear over concentration of 1.0 x 10(-7) - 5.0 x 10(-5) M with a detection limit of 6 x 10(-8) M at pH 5.4.  相似文献   

6.
New ranitidine hydrochloride (RaCl)-selective electrodes of the conventional polymer membrane type are described. They are based on incorporation of ranitidine-tetraphenylborate (Ra-TPB) ion-pair or ranitidine-phosphotungstate (RaPT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphthalate (DOP) or dibutylphthalate (DBP). The electrodes are fully characterized in terms of the membrane composition, solution temperature, and pH. The sensors showed fast and stable responses. Nernstian response was found over the concentration range of 2.0 x 10(-5) M to 1.0 x 10(-2) M and 1.0 x 10(-5) M to 1.0 x 10(-2) M in the case of Ra-TPB electrode and over the range of 1.03 x 10(-5) M to 1.00 x 10(-2) M and 1.0 x 10(-5) M to 1.0 x 10(-2) M in the case of Ra-PT electrode for batch and FIA systems, respectively. The electrodes exhibit good selectivity for RaCl with respect to a large number of common ions, sugars, amino acids, and components other than ranitidine hydrochloride of the investigated mixed drugs. The electrodes have been applied to the potentiometric determination of RaCl in pure solutions and in pharmaceutical preparations under batch and flow injection conditions with a lower detection limit of 1.26 x 10(-5) M and 5.62 x 10(-6) M at 25 +/- 1 degrees C. An average recovery of 100.91% and 100.42% with a relative standard deviation of 0.72% and 0.53% has been achieved.  相似文献   

7.
A new, simple, sensitive, low cost and rapid potentiometric method for direct determination of ultra trace amounts of sodium dodecyl sulfate (SDS) with a new DS(-)-selective electrode is reported. The electrode was prepared by electropolymerization of aniline in acidified DS- ion on the surface of a Pt electrode. The cyclic voltammetry (CV) was used for electropolymerization of polyaniline (PA) in the potential range of -200 to +1000 mV vs. Ag/AgCl. This sensor showed a Nernstian behavior (59.0 +/- 2.3 mV/decade) over a very wide linear range (1.0 x 10(-9)-3.0 x 10(-6) M) with a detection limit of 1.0 x 10(-9) M. The response time of the electrode was 15 s for 1.0 x 10(-7) M of analyte; the electrode can be used for 4 weeks without any major deviation. This electrode can be used in the pH range of 3.5-9.8. The selectivity of electrode to DS- over some organic, inorganic and anionic surfactants was investigated with the fixed primary ion method. The results show that the electrode is highly selective to DS- ion over other ions. The proposed electrode was applied to the determination of DS- in real samples.  相似文献   

8.
The electrochemical response characteristics of poly(vinyl)chloride (PVC) based membrane sensors for determination of tetramisole hydrochloride (TmCl) is described. The membranes of these electrodes consist of tetramisole-tetraphenyl borate (Tm-TPB), chlorophenyl borate (Tm-ClPB), and phosphotungstate (Tm(3)-PT) ion associations dispersed in a PVC matrix with dibutylpthalate as a plasticizer. The electrodes were fully characterized in terms of composition, life span, usable pH range, and working concentration range and ionic strength. The electrodes showed Nernstian response over the concentration ranges of 7.4 x 10(-7) to 1.0 x 10(-2) M, 1.7 x 10(-6) to 1.0 x 10(-2) M, and 5.6 x 10(-6) to 1.0 x 10(-2) M TmCl, respectively, and were applied to the potentiometric determination of tetramisole ion in pure solutions and pharmaceutical preparations. The potentiometric determination was also used in the determination of tetramisole in pharmaceutical preparations in four batches of different expiration dates. The electrodes exhibited good selectivity for TmCl with respect to a large number of excipients such as inorganic cations, organic cations, amino acids, and sugars. The solubility product of the ion-pair and the formation constant of the precipitation reaction leading to the ion-pair formation were determined conductometrically. The new potentiometric method offers the advantages of high-throughput determination, simplicity, accuracy, automation feasibility, and applicability to turbid and colored sample solutions.  相似文献   

9.
A sulfate ion-selective PVC membrane sensor based on 4-(4-bromophenyl)-2,6-diphenylpyrilium perchlorate (BDPP) as a novel sensing material is successfully developed. The electrode shows a good selectivity for sulfate ion with respect to common organic and inorganic anions. The sensor exhibits a good linear response with slope of -28.9+/-0.5 mV per decade over the concentration range of 1.0x10(-6)-1.0x10(-2) M, and a detection limit of 8.0x10(-7) M of SO(4)(2-) ions. The electrode response is independent of pH in the range of 4.0-9.0. The proposed sensor was applied as an indicator electrode in potentiometric titration of sulfate and barium ions, and to the determination of zinc in zinc sulfate tablets.  相似文献   

10.
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.  相似文献   

11.
A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10(-6) M. It has a response time of 30 s and can be used for at least 3 months without any divergence in the potential. The potentiometric response is independent of the pH, in the pH range 1.6 - 10.0. The proposed electrode has shown very high selectivity for the triiodide ion over a wide variety of other anions. This electrode was successfully applied as an indicator electrode in the potentiometric titration of ascorbic acid and hydroquinone from pharmaceutical preparations as well as ascorbic acid in orange juice and dissolved O2 in tap water.  相似文献   

12.
Arvand M  Asadollahzadeh SA 《Talanta》2008,75(4):1046-1054
A novel ion-selective PVC membrane sensor for Al(III) ions based on 6-(4-nitrophenyl)-2-phenyl-4-(thiophen-2-yl)-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NTDH) as a new ionophore has been prepared and studied. The electrode exhibit a good response for aluminum ion over concentration range of 1.0x10(-6) to 1.0x10(-1) mol L(-1) with a Nernstian slope of 19.6+/-0.4 mV per decade and low detection limit of 6.3x10(-7) mol L(-1). The best performance was obtained with membrane composition 30% poly(vinyl chloride), 62% acetophenone, 5% oleic acid, 3% ionophore and 2 ml tetrahydrofuran. NTDH-based electrode was suitable for aqueous solutions of pH 3. It has relatively fast response time (approximately 10 s) and can be used at least for 3 months without any considerable divergence in potentials. The proposed membrane electrode revealed good selectivity for Al(III) ions over a wide variety of other cations. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The formation constant and stoichiometry ratio of ionophore-Al(III) complex were calculated at 25 degrees C by using segmented sandwich membrane method. It was used in non-aqueous solvents and also as indicator electrode in potentiometric determination of Al(III) ions in some real samples.  相似文献   

13.
Triprolidine (Trip) ion selective electrodes of three types: the conventional polymer membrane (I), graphite coated electrode (II) and carbon paste electrode (III), have been prepared, based on the ion pair of triprolidine hydrochloride with sodium tetraphenylborate. The electrodes exhibit a linear response with a mean calibration graph slope of 56.12, 55.00 and 54.32 mV decade(-1) at 25 degrees C for I, II and III, respectively, within the concentration ranges 1.96 x 10(-5) - 1.00 x 10(-2) M for I and 3.84 x 10(-5) - 1.00 x 10(-2) M for II and III. The detection limits are 1.13+/-0.13 x 10(-5), 1.70+/-0.06 x 10(-5) and 1.78+/-0.05 x 10(-5) M for the three electrodes, respectively. The change of pH within the ranges 4.85 - 8.75 and 4.70 - 8.50 for I and III, respectively, did not affect the electrode performance. The standard electrode potentials were determined at different temperatures and were used to calculate the isothermal coefficient of the electrode. The electrodes showed a very good selectivity for Trip with respect to a large number of inorganic cations and compounds. The standard addition method was applied to the determination of TripCl in pure solution, pharmaceutical preparations, and urine samples.  相似文献   

14.
Liquid-liquid extractions of sodium and potassium picrates with naphtho-15-crown-5 (N15C5) into 1,2-dichloroethane are studied, in order to clarify the factors governing the high potassium ion selectivity of the N15C5-based membrane electrode. The distribution coefficient of N15C5 between water and 1,2-dichloroethane was 1800 at 15°C. The formation constants of the complexes of N15C5 with the sodium ion and the potassium ion in the aqueous phase were less than unity and there was no remarkable difference between their values. Potassium picrate was mainly extracted into 1,2-dichloroethane by forming the 2:1 N15C5-potassium complex, while sodium picrate was extracted by forming the 1:1 complex. The extraction constants for sodium picrate and potassium picrate were 103.86 and 107.61, respectively, The high potassium selectivity is concluded to be due to the high extractability of the 2:1 potassium complex.  相似文献   

15.
Abbas MN  Mostafa GA  Homoda AM 《Talanta》2001,55(3):647-656
A novel PVC membrane electrode selective for the determination of pentachlorophenolate (PCP) ion based on 2,3,5-triphenyl-2H-tetrazolium (TPT) pentachlorophenolate ion pair as an electroactive material is described. The electrode shows a linear response for PCP ion over the concentration range of 6x10(-5) to 1x10(-2) M with lower detection limit of 4x10(-5) M at 25 degrees C. The electrode posses a Nernstian slope of -55.0+/-1.0 mV/decade and a fast potential response of 45 s, which is almost constant over a pH range of 5.5-10.5. Selectivity coefficient data for some common ions show negligible interference, however, 2,4,6-trichlorophenolate and cetylpyridinium ions interfere. An average recovery of 96.2% with relative standard deviation of 2.3% has been achieved for the determination of 75.0 ppm PCP in wastewater samples. The determination of PCP in soil and wood samples gave results that compare favorably with those obtained by gas chromatography. The electrode has been utilized as an end point indicator electrode for the determination of PCP using potentiometric titration.  相似文献   

16.
An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slope of -59.8 +/- 0.5 mV decade(-1) for I- ion over a concentration range of 1.0 x 10(-5) - 1.0 x 10(-2) M with a limit of detection of 7.0 x 10(-6) M. The electrode displays a good selectivity for I- with respect to a number of inorganic and organic species. It canbe used over a pH range of 2.5 - 8.5. The membrane sensor was successfully applied to the determination of iodide in water samples and blood serum, as well as in pharmaceutical products such as iodoquinol and thyroxin.  相似文献   

17.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a good Nernstian slope of -58.9 +/- 0.7 mV decade(-1), over a wide pH range of 3.5 - 8.5 and a linear range of 1.0 x 10(-6) - 1.0 x 10(-1) M for thiocyanate. The detection limit of electrode was 3.1 x 10(-7) M SCN(-). The selectivity coefficients determined by a fixed interference method (FIM) indicate that a good discriminating ability towards the SCN- ion compared to other anions. The proposed sensor had a fast response time of about 5 - 15 s and could be used for at least 3 months without any considerable divergence in the potential. It was applied as an indicator electrode in the titration of thiocyanate with Ag+ and in the potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

18.
A PVC membrane electrode for aluminium ion based on bis(5-phenyl azo salicylaldehyde) 2,3-naphthalene diimine (5PHAZOSALNPHN) as an ion carrier was developed. The electrode exhibits a Nernstian slope of 19.3+/-0.8 mV per decade and a linear range of 5.0x10(-6)-1.0x10(-2) M for Al(NO(3))(3). The limit of detection is 2.5x10(-6) M. It has a fast response time of about 10 s and can be used for at least 10 weeks without observing any deviation. The proposed membrane sensor revealed good selectivity for Al(3+) over a wide variety of other metal ions and could be used in pH range of 2.9-5.0. It was used as an indicator electrode in potentiometric titration of aluminium ion.  相似文献   

19.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

20.
Mahajan RK  Kumar M  Sharma V  Kaur I 《The Analyst》2001,126(4):505-507
A PVC membrane electrode for silver(I) ion based on Schiff base-p-tert-butylcalix[4]arene is reported. The electrode works well over a wide range of concentration (1.0 x 10(-5)-1.0 x 10(-1) mol dm-3) with a Nernstian slope of 59.7 mV per decade. The electrode shows a fast response time of 20 s and operates in the pH range 1.0-5.6. The sensor can be used for more than 6 months without any divergence in the potential. The selectivity of the electrode was studied and it was found that the electrode exhibits good selectivity for silver ion over some alkali, alkaline earth and transition metal ions. The silver ion-selective electrode was used as an indicator electrode for the potentiometric titration of silver ion in solution using a standard solution of sodium chloride; a sharp potential change occurs at the end-point. The applicability of the sensor to silver(I) ion measurement in water samples spiked with silver nitrate is illustrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号