首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper reports the results of a rapid method to determine sucrose in chocolate mass using near infrared spectroscopy (NIRS). We applied a broad-based calibration approach, which consists in putting together in one single calibration samples of various types of chocolate mass. This approach increases the concentration range for one or more compositional parameters, improves the model performance and requires just one calibration model for several recipes. The data were modelled using partial least squares (PLS) and multiple linear regression (MLR). The MLR models were developed using a variable selection based on the coefficient regression of PLS and genetic algorithm (GA). High correlation coefficients (0.998, 0.997, 0.998 for PLS, MLR and GA-MLR, respectively) and low prediction errors confirms the good predictability of the models. The results show that NIR can be used as rapid method to determine sucrose in chocolate mass in chocolate factories.  相似文献   

2.
傅里叶变换近红外光谱法快速检测人血清生化成分   总被引:1,自引:0,他引:1  
应用傅里叶变换近红外光谱透射技术结合偏最小二乘法(PLS)建立了人血清中7种生化成分的定标模型,利用内部交叉验证和自动优化功能对定标模型进行了优化,确定了最优建模参数。模型对人血清中总胆固醇、甘油三酯、总蛋白、白蛋白、载脂蛋白B、低密度脂蛋白胆固醇、葡萄糖定标样品集的预测值与化学值的相关系数r分别为0.9011、0.9593、0.9249、0.761、0.8831、0.5191、0 9148,预测校正标准误差RMSECV分别为15mg/dL,21.6mg/dL,2 66g/L,3 96g/L,0.091g/L,16.2mg/dL,0.49mmol/L。  相似文献   

3.
4.
Using proper calibration data Fourier-transform near infrared spectroscopy is used for developing multivariate calibrations for different analytical determinations routinely used in the surfactants industry. Four products were studied: oleyl-cetyl alcohol polyethoxylated, cocamidopropyl betaine (CAPB), sodium lauryl sulfate (SLS) and nonylphenol polyethoxylated (NPEO). Calibrations for major as well as very low concentrated compounds were achieved and every model was validated through linearity, bias, accuracy and precision tests, showing good results and the viability of NIR spectroscopy as a full quality control method for this products. Duplicate and complete analysis on a single sample takes at most 3 min, requiring neither sample preparation nor the use of reagents. The analytical reference procedures involved in this work represent the typical ones used in the industry and the NIR method shows good results in the analysis of components with weight concentrations less than 1%.  相似文献   

5.
近红外光谱法快速检测烟草中部分香气物的应用研究   总被引:6,自引:0,他引:6  
应用傅立叶变换近红外漫反射光谱仪,从500个样品中按高、中、低含量挑选出具代表性的150~172个烟草样品建立了近红外光谱与烟草中的苹果酸、柠檬酸和石油醚提取物成分含量间的数学模型,用建立的模型对36个样品进行预测,结果表明,各成分近红外预测值与实测值之间的平均偏差:苹果酸为0.090,柠檬酸为0.040,石油醚提取物为0.124;且近红外预测值与化学法不存在显著性差异,近红外光谱分析技术可初步用于烟草部分香气成分的快速定量分析.  相似文献   

6.
The aim of this study was to investigate the influence of compatibility on the contents of main compounds in Paeoniae Radix Alba and Atractylodis Macrocephalae Rhizoma. Ten compounds were separated on an Inertsil ODS‐SP Extend C18 column (250 mm × 4.6 mm, 5 μm) and detected by a diode array detector with the mobile phase consisting of aqueous phosphoric acid (0.1%, v/v; A) and acetonitrile (B) by linear gradient elution. All analytes showed good linearity over a wide concentration range (r2 ≥ 0.9989). The limits of detection and quantification were <8.10 and 10.80 μg/mL, respectively. The intra‐ and interday variations were <4.36%. The average recoveries were observed from 94.90 to 103.38%, with relative standard deviation ranging from 1.23 to 3.15% for the analytes. The established method was reliable enough for global quality evaluation of Paeoniae Radix Alba, Atractylodis Macrocephalae Rhizoma, and their co‐decoctions.  相似文献   

7.
应用傅里叶变换近红外漫反射光谱技术,通过对光谱预处理方法的选择和模型优化,建立了准确度较好的聚乙烯醇醇解度近红外定量分析模型,并验证了其可行性。通过验证试验表明,其预测值接近于化学法测定值,适合聚乙烯醇醇解度快速测定。  相似文献   

8.
I. Esteban-Díez 《Talanta》2007,71(1):221-229
Near infrared spectroscopy (NIRS) was used to discriminate between arabica and robusta pure coffee varieties and blends of varied varietal composition. Direct orthogonal signal correction (DOSC) pre-processing method was applied on a set of 191 roasted coffee NIR spectra from both pure varieties and blends varying the final robusta content from 0 to 60% (w/w) in order to remove information unrelated to the actual varietal composition of samples. The corrected NIR spectra, as well as raw NIR spectra, were used to develop separate classification models using the potential functions method as class-modelling technique, exploring several options more or less restrictive according to the final number of considered categories. All constructed classification models were compared to evaluate their respective qualities and to show the suitability of applying DOSC method as pre-processing step for developing improved classification models for coffee varietal identification purposes.  相似文献   

9.
The ability of near infrared reflectance spectroscopy to classify the rosasite group minerals from spectral characteristics is demonstrated. NIR spectroscopy can be regarded as an alternative tool for structure analysis. The spectra show that rosasite group minerals with different cations can be distinguished. Ni2+ in nullaginite [Ni2(CO3)(OH)2] is conspicuous through a single broad band absorption feature at 8525 cm-1, extended from 11,000 to 7000 cm-1. The effect of Ni on Cu is seen in the spectrum of glaukosphaerite [(Cu, Ni)2(CO3)(OH)2] both by a red shift of the spectrum and reduction in intensity of bands with variable positions of band maxima for Cu2+ at 6995 cm-1 and Ni2+ at 7865 cm-1. The spectrum of rosasite [(Cu, Zn)2(CO)3(OH)2] is characterised by Cu2+ band at 7535 cm-1. Kolwezite [(Cu, Co)2(CO)3(OH)2] is a spectral mixture of Cu and Co but optically separated by Co2+ and Cu2+ peaks at 8385 and 7520 cm-1. Vibrational spectra of carbonates show a number of bands in the 7000-4000 cm-1 region attributable to overtones, combination of OH stretching and deformation modes. They appear to be uniform in nature since the structure of rosasite group minerals is identical. The complexity of these features varies between samples because of the variation in composition and hence is useful for discriminating different hydrous carbonates.  相似文献   

10.
不同产地中药赤芍在振荡体系中的化学指纹图谱研究   总被引:1,自引:0,他引:1  
采用H2 SO4 - CH2 (COOH)2 - Ce2( SO4)3- KBrO3化学振荡体系,研究了中药赤芍的化学指纹图谱,并对温度、赤芍用量进行了考察,确定体系的最佳实验条件为12 mL 3.0 mol/L H2SO4溶液、6 mL 0.4 mol/LCH2( COOH)2溶液、3 mL 0.005 mol/L ...  相似文献   

11.
Evaluation of uncertainty affecting predictions is a major trend in analytical chemistry and chemometrics. Several approximate expressions and resampling methods have been proposed for the estimation of prediction uncertainty when using multivariate calibration. This article proposes a new expression for the variance of prediction, adapted to near infrared spectroscopy specificities and particularly to the spectral error structure, induced by the high colinearity of the variables. The proposed analytical expression enables a detailed evaluation of the different contributions and components of uncertainty affecting the model. An application to real data of feedstuff near infrared spectra related to protein content has shown its advantages.  相似文献   

12.
In this work, Raman and Near InfraRed (NIR) spectroscopies are evaluated for the monitoring of different semicontinuous emulsion homo- and co-polymerization reactions. Important process variables, namely monomer concentrations and average particle sizes, were monitored by both techniques under realistic conditions that would be found in an industrial environment (e.g. low signal/noise ratio, probe placed in the reaction medium). Results suggest that Raman and NIR are suitable for on-line monitoring of emulsion polymerization reactions and that the success of their application is mainly related to representative calibration models used for the estimation of the properties of interest.  相似文献   

13.
A relationship was established between the organic matter content in soils determined by conventional chemical measurements and by diffuse reflectance spectra in the near infrared region (1000-2500 nm). Radial basis function networks (RBFN) with regularized forward selection to control the model complexity were used for non-parametric regression, resulting in a RMSEP of 0.25%. The observed results using RBFN were better than those obtained by partial least squares regression (PLS) and multi-layer perceptron (MLP) feed-forward networks with a back-propagation learning algorithm. RBFN is a suitable tool to model this complex system, with additional advantages over MLP, since the training procedure is less dependent on the initial conditions.  相似文献   

14.
Near infrared (NIR) spectroscopy was used to simultaneously predict the concentrations of malvidin-3-glucoside (M3G), pigmented polymers (PP) and tannins (T) in red wine. A total of 495 samples from 32 commercial scale red wine fermentations over two vintages using two grape varieties (Cabernet Sauvignon and Shiraz), and also including as additional variables two types of fermenters, two different yeasts, and three fermentation temperatures were used. Samples were scanned in transmission mode (400-2500 nm) using a monochromator instrument (NIRSystems6500). Calibration equations were developed from high performance liquid chromatography (HPLC) and NIR data using partial least squares (PLS) regression with internal cross validation. Using PLS regression, very good calibration statistics (Rcal2>0.80) were obtained for the prediction of M3G, PP and T with standard deviation (S.D.)/standard error in cross validation (SECV) ratio (residual predictive deviation, RPD)) ranging from 1.8 to 5.8. It was concluded that near infrared spectroscopy could be used as rapid alternative method for the prediction of the concentration of phenolic compounds in red wine fermentations.  相似文献   

15.
The aim of this study was to assess the feasibility of near infrared spectroscopy (NIRS) for analysis of acyclovir in plasma. This methodology was based on the direct measurement of the transmission spectra of liquid samples and a multivariate calibration model (partial least squares, PLS) to determine the acyclovir concentration in plasma sample. The PLS calibration set was built on using the spiked samples by mixing different amounts of acyclovir. Concentration of acyclovir in the plasma samples was calculated employing a 6-factors PLS calibration using the spectral information in the range of 6102-5450 cm− 1. The root mean square errors of prediction (RMSEP) found was 1.21 for acyclovir. The developed PLS-NIRS procedure allows the determination of 120 samples/h does not require any sample pretreatment and avoids waste generation.  相似文献   

16.
Different calibration techniques are available for spectroscopic applications that show nonlinear behavior. This comprehensive comparative study presents a comparison of different nonlinear calibration techniques: kernel PLS (KPLS), support vector machines (SVM), least-squares SVM (LS-SVM), relevance vector machines (RVM), Gaussian process regression (GPR), artificial neural network (ANN), and Bayesian ANN (BANN). In this comparison, partial least squares (PLS) regression is used as a linear benchmark, while the relationship of the methods is considered in terms of traditional calibration by ridge regression (RR). The performance of the different methods is demonstrated by their practical applications using three real-life near infrared (NIR) data sets. Different aspects of the various approaches including computational time, model interpretability, potential over-fitting using the non-linear models on linear problems, robustness to small or medium sample sets, and robustness to pre-processing, are discussed. The results suggest that GPR and BANN are powerful and promising methods for handling linear as well as nonlinear systems, even when the data sets are moderately small. The LS-SVM is also attractive due to its good predictive performance for both linear and nonlinear calibrations.  相似文献   

17.
A rapid near infrared spectroscopy analysis method was developed for the geographical origin discrimination and content determination of Radix scutellariae, a kind of Traditional Chinese Medicine (TCM). 81 R. scutellariae samples from six different origins were analyzed with HPLC-UV as reference method. The NIR spectra were collected in integrating-sphere diffused reflection mode and processed with different spectra pretreated methods. Discriminant analysis (DA) and discriminant partial least squares (DPLS) were applied to classify the geographical origins of those samples, and the latter had a better predictive ability with 100% accuracy after two exceptional samples eliminated from the calibration set. For the quantitative calibration, the samples were divided into calibration set and validation set by Kennard-Stone algorithm. The models of baicalin, wogonoside, baicalein, wogonin were established with partial least squares (PLS) algorithm and the optimal principal component (PC) numbers were selected with Leave-One-Out (LOO) cross-validation. The established models were evaluated with the root mean square error of prediction (RMSEP) and corresponding correlation coefficients. The correlation coefficients of all the four calibration models are above 0.920, and the RMSEPs of baicalin, wogonoside, baicalein and wogonin are 0.752%, 0.094%, 0.418% and 0.139%, respectively. This research indicated that the NIR diffuse reflection spectroscopy could be used for the rapid analysis of R. scutellariae, which is beneficial to the quality control of this raw material in TCM pharmaceutical factory, and will also help to solve analogous problems.  相似文献   

18.
This paper indicates the possibility to use near infrared spectroscopy (NIR) combined with PLS as a rapid method to estimate the quality of green tea. NIR is used to build calibration models to predict the content of caffeine, epigallocatechin gallate (EGCG) and epicatechin (EC) and for the prediction of the total antioxidant capacity of green tea. For the determination of the total antioxidant capacity, the trolox equivalent antioxidant capacity (TEAC) method is used. Until now, the prediction of the antioxidant capacity as such by use of NIR has not been reported. For caffeine and TEAC, models are build for the whole green tea leaves and also for the ground leaves. For the polyphenols (EGCG and EC), only models for the whole leaves are investigated. A partial least squares (PLS) algorithm is used to perform the calibration. To decide upon the number of PLS factors included in the PLS model, the model with the lowest root mean square error of cross-validation (RMSECV) for the training set is chosen. The correlation coefficient (r) between the predicted and the reference results for the test set is used as an evaluation parameter for the models: for the TEAC results r=0.90 for the model with the whole leaves, r=0.86 for the model with the powdered leaves are obtained. The caffeine prediction model has a correlation coefficient r=0.96 for the whole leaves and r=0.93 for the ground leaves. The correlation coefficient for the EGCG and the EC content models are, respectively 0.83 and 0.44.  相似文献   

19.
气相色谱-串联质谱法同时测定白芍中10种有机磷农药残留   总被引:4,自引:0,他引:4  
建立了同时测定中药白芍中10种有机磷农药残留含量的气相色谱–串联质谱方法。样品用乙腈超声提取,提取液经凝胶渗透色谱净化后,以VF–5毛细管色谱柱(30 mm×0.25 mm,0.25μm)分离,串联四极杆质谱仪为检测器进行定性、定量分析。10种有机磷农药残留的检出限为0.02~4.0 mg/kg,实际样品的加标回收率为75%~105%,相对标准偏差为4%~10%。该方法能够满足白芍中有机磷农药残留的定性、定量检测要求。  相似文献   

20.
The aim of this study was to establish a rapid quality assessment method for Gentianae Macrophyllae Radix (RGM) using near-infrared (NIR) spectra combined with chemometric analysis. The NIR spectra were acquired using an integrating sphere diffuse reflectance module, using air as the reference. Capillary electrophoresis (CE) analyses were performed on a model P/ACE MDQ Plus system. Partial least squares-discriminant analysis qualitative model was developed to distinguish different species of RGM samples, and the prediction accuracy for all samples was 91%. The CE response values at each retention time were predicted by building a partial least squares regression (PLSR) calibration model with the CE data set as the Y matrix and the NIR spectra data set as the X matrix. The converted CE fingerprints basically match the real ones, and the six main peaks can be accurately predicted. Transforming NIR spectra fingerprints into the form of CE fingerprints increases its interpretability and more intuitively demonstrates the components that cause diversity among samples of different species and origins. Loganic acid, gentiopicroside, and roburic acid were considered quality indicators of RGM and calibration models were built using PLSR algorithm. The developed models gave root mean square error of prediction of 0.2592% for loganic acid, 0.5341% for gentiopicroside, and 0.0846% for roburic acid. The overall results demonstrate that the rapid quality assessment system can be used for quality control of RGM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号