1.
Headspace solid phase microextraction (headspace SPME) has been demonstrated to be an excellent solvent-free sampling method. One of the major factors contributing to the success of headspace SPME is the concentrating effect of the fiber coating toward organic compounds. The affinity of the fiber coating toward very volatile analytes, such as chloromethane, may, however, not be large enough for detection at the parts per trillion concentration level. Static headspace analysis, on the other hand, is very effective for these very volatile compounds. As analyte volatility decreases, the sensitivity of static headspace analysis drops. The complementary nature of these two sampling methods can be exploited by combining the SPME device with a gastight syringe. The sensitivity of the new sampling device is better than that of SPME for very volatile compounds or that of static headspace analysis for less volatile compounds. This new method can sample a wide range of compounds from chloromethane (b.p. −24°C) to bromoform (b.p. 149°C) with estimated limits of detection at the low parts per trillion level.  相似文献   

2.
A reliable and sensitive method for simultaneous determination of perchloroethylene (PCE), trichloroethylene (TCE), and trichloroacetic acid (TCA) in human urine by gas chromatography-mass spectrometry (GC/MS) is described after extraction and preconcentration by a new solid-phase microextraction (SPME) adsorbent. The potential of single-walled carbon nanotubes (SWCNTs) as SPME adsorbent for the pre-concentration of environmental pollutants has been investigated in recent years. This work was carried out to investigate the feasibility of SWCNTs as a headspace SPME adsorbent for the determination of chloroethylenes in human urine. SWCNTs were attached onto a stainless steel wire through an organic binder. Potential factors affecting the extraction efficiency, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity were optimized. The developed method showed good performance. For PCE and TCE, calibration curves were linear (r 2 ?≥?0.994) over the concentration ranges from 15 to 8000?ng?L?1 and the limit of detection (LOD) at signal-to-noise (S/N) ratio of 3 was 5?ng?L?1. The analytical procedure also involves derivatization of TCA with dimethyl sulfate, before headspace sampling. For TCA the linear range and LOD were 45-8000 (r 2 ?≥?0.992) and 15?ng L?1, respectively. In addition, a comparative study between the SWCNT and a commercial carboxen/polydimethylsiloxane (CAR/PDMS) SPME fibre for the determination of chloroethylenes in human urine was carried out. SWCNT fibre showed higher extraction capacity, better thermal stability (over 350°C) and longer life span (over 200 times) than the commercial CAR/PDMS fibre. The developed method was successfully applied to determine chloroethylenes in human urine samples. As the results indicated, the mean concentrations of TCE, PCE and TCA in exposed workers (dry-cleaning industry workers) were significantly greater than that of control group.  相似文献   

3.
An on-line quinine-sensitized photo-oxidation with quenched chemiluminescence (CL) detection method is developed for phenols using flow injection (FI) and liquid chromatography (LC). This detection method is based on the decrease of light emission from the luminol CL reaction due to the photo-oxidation of phenols that scavenge the photogenerated reactive oxygen species (e.g. singlet oxygen () and superoxide (O2)). On-line photo-oxidation is achieved using a coil photo-reactor made from fluoroethylene-propylene copolymer tubing ( mm i.d.) coiled around a mercury UV lamp. A buffer of pH 7 and a concentration of 350 μM for quinine sulfate are determined optimum for the sensitized photo-oxidation. Using a carrier system flow rate of 60 μl/min, calibration curves taken by FI for 10 phenolic compounds in aqueous solutions showed this decreasing sensitivity order: 4-chlorophenol, phenol, 4-nitrophenol, 3-hydroxy-l-kynurenine, 2-nitrophenol, salicylate, 3-nitrophenol, catechol, 2,4-dinitrophenol, and 2,4-dichlorophenol. This detection method using two tandem coil photo-reactors is also applied for the LC separation of phenol, 4-nitrophenol and 4-chlorophenol on an octadecyl (C18) silica LC column using acetonitrile-H2O (40:60, v/v) as a mobile phase. The quenched CL detection limits (about 1 μM or 20 pmol) for phenol and 4-chlorophenol are comparable to those for UV detection at 254 nm. Some selectivity in the quenched CL detection is evident by no interference in the FI phenol response even when benzaldehyde and phenethanol concentrations are 8 and 15 times that of phenol.  相似文献   

4.
Nanostructured titania-based solid-phase microextraction (SPME) fibers were fabricated through the in situ oxidation of titanium wires with H2O2 (30%, w/w) at 80 °C for 24 h. The obtained SPME fibers possess a ∼1.2 μm thick nanostructured coating consisting of ∼100 nm titania walls and 100-200 nm pores. The use of these fibers for headspace SPME coupled with gas chromatography with electron capture detection (GC-ECD) resulted in improved analysis of dichlorodiphenyltrichloroethane (DDT) and its degradation products. The presented method to detect DDT and its degradation products has high sensitivity (0.20-0.98 ng L−1), high precision (relative standard deviation R.S.D. = 9.4-16%, n = 5), a wide linear range (5-5000 ng L−1), and good linearity (coefficient of estimation R2 = 0.991-0.998). As the nanostructured titania was in situ formed on the surface of a titanium wire, the coating was uniformly and strongly adhered on the titanium wire. Because of the inherent chemical stability of the titania coating and the mechanical durability of the titanium wire substrate, this new SPME fiber exhibited long life span (over 150 times).  相似文献   

5.
The application of a manual operated solid-phase microextraction (SPME)-HPLC interface is discussed for the analysis of thermally labile analytes in aqueous matrices. The technique has been applied on-site at a flooded rice field to demonstrate its potential for real time extraction of the herbicide profoxydim. Thus, compounds which would otherwise easily degrade in the aqueous matrices within hours or days could be determined more accurately. The fibers were shipped back to the laboratory with express delivery where the target analyte was desorbed from the fiber and determined by HPLC-UV analysis. The SPME method was characterized by significant ruggedness where conventional techniques such as liquid-liquid extraction and solid-phase extraction require additional shipping and handling costs and time-consuming multiple sample preparation steps. In general, any delay in shipping the aqueous samples to the laboratory has the potential for sample degradation and a loss in accuracy when using non on-site extraction techniques. Fifty microm Carbowax-templated resin coatings were most suitable for coupling SPME to HPLC in order to achieve a high sensitivity for polar analytes. The SPME technique was characterized by a good sensitivity and a precision less than 10% RSD. The SPME-LC-UV method was linear over at least three orders of magnitude while achieving a limit of detection in the lower microg/l range. The on-site SPME method has shown significantly increased accuracy. Profoxydim was determined at concentrations of ca. 180 microg/l 3 h after an application on a flooded bare soil field.  相似文献   

6.
Cathodic electrodeposition (CED) has received great attention in metal-organic frameworks (MOFs) synthesis due to its distinguished properties including simplicity, controllability, mild synthesis conditions, and product continuously. Here, we report the fabrication of thin (Et3NH)2Zn3(BDC)4 (E-MOF-5) film coated solid phase microextraction (SPME) fiber by a one-step in situ cathodic electrodeposition strategy. Several etched stainless steel fibers were placed in parallel in order to achieve simultaneously electrochemical polymerization. The influence of different polymerization parameters Et3NHCl concentration and polymerization time were evaluated. The proposed method requires only 20 min for the preparation of E-MOF-5 coating. The optimum coating showed excellent thermal stability and mechanical durability with a long lifetime of more than 120 repetitions SPME operations, and also exhibited higher extraction selectivity and capacity to four estrogens than commonly-used commercial PDMS coating. The limits of detection for the estrogens were 0.17–0.56 ng mL−1. Fiber-to-fiber reproducibility (n = 8) was in the respective ranges of 3.5%–6.1% relative standard deviation (RSD) for four estrogens for triplicate measurements at 200 ng mL−1. Finally, the (E-MOF-5) coated fiber was evaluated for ethinylestradiol (EE2), bisphenol A (BPA), diethylstilbestrol (DES), and hexestrol (HEX) extraction in the spiked milk samples. The extraction performance of this new coating was satisfied enough for repeatable use without obvious decline.  相似文献   

7.
We studied the sorption of amphetamine as a model drug to represent small, polar organic cations to a new SPME coating combining C18 and propylsulfonic acid. This combination of hydrophobic and strong cation exchange (SCX) groups was compared to conventional SPME fibers with polyacrylate (PA) or C18 coating. The affinity of amphetamine at physiological pH (PBS) was 20 to 180 times greater for the new C18/SCX coating than for C18 alone and PA of different coating thickness. As amphetamine is a base and >99% protonated at physiological pH, this enhanced affinity is attributed to the ion-exchange phase in the coating. Tests at pH above the pKa of amphetamine show that, when normalized to the coating volume, neutral amphetamine also has a higher affinity compared to PA. As ion-exchange groups are not unlimitedly present in the coating, amphetamine isotherms level off to a saturation concentration on the C18/SCX fiber at the highest tested aqueous concentrations. Also, other cations (Na+, K+, Ca2+) compete for the SCX sites and decrease the sorption coefficients, e.g. by 1.7 log units when comparing Milli-Q water with PBS. The C18/SCX fiber provides improved sensitivity over some of the classic SPME fibers. However, care should be taken near the cation exchange capacity of the fiber and the fiber should be calibrated in an appropriate matrix so as to eliminate competition effects.  相似文献   

8.
A novel HBT-hemicyanine hybrid was prepared. This hybrid not only displays a large red-shifted (Δλ = 125 nm) emission compared to the well known ESIPT dye HBT, but also can be used as a new probe for rapid, colorimetric and ratiometric fluorescent detection of bisulfite with high selectivity and sensitivity in aqueous solution. The detection limit of this probe for HSO3 was calculated to be about 56 nM with a linear range of 0–25 μM. The potential application of this probe was exampled by detection of bisulfite in real food samples and living cells. Overall, this work not only provided a new ratiometric sensing platform, but also provided a new promising colorimetric and ratiometric fluorescent probe for bisulfite.  相似文献   

9.
Kazemi  Maryam  Niazi  Ali  Yazdanipour  Atisa 《Chromatographia》2021,84(6):559-569

Multiwalled carbon nanotubes were exposed to hydrothermal treatment for obtaining graphene oxide nanoribbons (GONRs). The fabricated graphene oxide nanoribbons have been morphologically and compositionally characterized via FE-SEM, XRD, and FT-IR techniques. The as-synthesized GONRs have been used as sorbent phase for headspace solid-phase microextraction of phthalate esters (PEs) from aqueous solutions. In this regard, the GC–FID analysis route has been used for quantification of PEs. The new SPME fiber shows remarkable analytical figures of merit including broad dynamic linear ranges, low limits of detection, as well as good stability and reasonable relative standard deviations for evaluation of PEs. The linearity of the method for analysis of PEs including DnBP, DnPP, DEHP, DEHA, BBP, and DMP was between the range of 0.05–100, 0.05–100, 0.1–100, 0.1–100, 0.2–100, and 0.5–100 μg L?1, respectively. The limits of detection (based on S/N?=?3) and correlation coefficients were found to be in the range of 0.02–0.2 μg L?1 and 0.9907–0.9952, correspondingly. The prepared GONR-coated SPME fiber shows larger extraction yield in comparison to pristine MWNTs and commercial PDMS SPME fibers. Furthermore, real sample analysis showed that there is no significant matrix effect for evaluation of PEs from environmental water samples and proposed method could be used for evaluation and determination of PEs from aqueous samples in a precise and accurate manner. The existence of functional groups, π–π interactions, as well as hydrogen bonding between adsorbent phase and PE analytes could be the reason for observing such a high extraction yield.

  相似文献   

10.
A simple and rapid solid-phase microextraction (SPME) method is presented based on activated charcoal–PVC fiber for determination of some organophosphorus pesticides from aqueous samples in direct mode SPME. After optimization of the experimental variables affecting SPME of the target compounds from aqueous solutions, the proposed method was applied to determine pesticides in fruit juice. The analytes in this procedure were preconcentrated for 15 min on the SPME fiber and subsequently desorbed by heating the fiber at 200 °C for 5 min in the GC injection port. Separation was on a capillary column GC followed by flame ionization detection. Recoveries of the pesticides studied in aqueous samples ranged 42%–63% and repeatability for all analytes was < 9% for a single fiber. Fiber-to-fiber reproducibility was < 18%.  相似文献   

11.
Triacetone triperoxide (TATP) is a high explosive synthesized from easily available reactants making it accessible for illicit uses. In this study, fast detection of TATP is achieved using a novel planar solid-phase microextraction (PSPME) as a preconcentration and sampling device for headspace analysis offering improved sensitivity and reduced sampling time over the conventional fiber-based solid-phase microextraction (SPME) when followed by ion mobility spectrometer (IMS) detection. Quantitation and comparison of the retention capabilities of PSPME as compared to the commercially available SPME were determined using TATP standards and analyzed using gas chromatography–mass spectrometry for SPME analysis and a commercial IMS with no instrumental modification for PSPME. Static and dynamic headspace extractions were used and compared for PSPME extractions, in which low milligram quantities of TATP were detected within 30 s of static mode sampling and less than 5 s in the dynamic mode sampling for PSPME–IMS.  相似文献   

12.
A glassy carbon electrode (GCE) modified with internal-electrolysis deposited gold nanoparticles (AuNPsied) was applied to sensitively and selectively detect As(III) by anodic stripping linear sweep voltammetry (ASLSV). The AuNPsied/GCE was prepared based on the redox replacement reaction between a supporting-electrolyte-free aqueous HAuCl4 and a copper sheet in saturated KCl separated by a salt bridge. Under optimum conditions (0.5 M aqueous H2SO4, 300-s preconcentration at − 0.4 V), the ASLSV peak current for the As(0)–As(III) oxidation responded linearly to As(III) concentration from 0.02 to 3 μM with a limit of detection (LOD) of 0.9 nM (0.07 μg L 1) (S/N = 3), while that for the As(III)–As(V) oxidation was linear with As(III) concentration from 0.02 to 1 μM with a LOD of 4 nM (0.3 μg L 1) (S/N = 3). An appropriate high-scan-rate for ASLSV can enhance both the sensitivity and signal-to-noise ratio. This method was applied for analyses of As(III) in real water samples.  相似文献   

13.
Solid-phase microextraction (SPME) represents a very simple and rapid method for the extraction of organophosphorus, triazine and 2,6-dinitroaniline pesticides from aqueous samples without making use of any solvents. The same fiber can be used repeatedly. Moreover, a sample volume as small as 3 mL can be employed with no loss in sensitivity. 34 compounds have been extracted from aqueous samples by SPME using a 85 m polyacrylate fiber. For organophosphorus pesticides, a 100 m polydimethylsiloxane fiber has been used additionally for comparison. The fibers were directly introduced into the heated split/splitless injector of the gas chromatograph and determined using a nitrogen-phosphorus detector. The method was evaluated with respect to the limit of detection (LOD), linearity and precision. The limit of detection (LOD) depends on the compound and varies from 0.005–0.09 g/L. The method is linear over at least three orders of magnitude with coefficients of correlation usually >0.999. For triazines and 2,6-dinitroanilines the coefficient of variation (precision) is <8% while for organophosphorus compounds it may reach values up to 18% (however, if the latter compounds are extracted using the polydimethylsiloxane phase considerably higher precision is achieved). The partitioning of the analyte between the aqueous phase and the polymeric phase depends on the hydrophobicity of the compound as expressed by the octanol/water partitioning coefficient (Pow). For triazines it was shown that there is a linear dependence of the logarithm of the analyte response on the log(Pow) i.e. the higher the hydrophobicity, the higher the affinity of the analytes to the polymeric phase of the fiber and the higher the response. Salt addition has a strong effect on the extraction efficiency. This effect increases with decreasing hydrophobicity (increasing polarity) of the compound. The triazines ametryn, atrazine, propazine, simazine and simetryn have been identified in a ground water well sample by SPMEGC/NPD.  相似文献   

14.
A new method is described for the qualitative and quantitative analysis of cyanide, a very short-acting and powerful toxic agent, in human whole blood. It involves the conversion of cyanide into hydrogen cyanide and its subsequent headspace solid-phase microextraction (HS-SPME) and detection by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring (SIM) mode. Optimizing the conditions for the GC/MS (type of column, injection conditions, temperature program) and SPME (choice of SPME fiber, effect of salts, adsorption and desorption times, adsorption temperature) led to the choice of a 75-microm carboxen/polydimethylsiloxane SPME fiber, with D3-acetonitrile as internal standard, and a capillary GC column with a polar stationary phase. Method validation was carried out in terms of linearity, precision and accuracy in both aqueous solutions and blood. The limit of detection (LOD) and limit of quantitation (LOQ) were determined only in aqueous solutions. The assay is linear over three orders of magnitude (water 0.01-10, blood 0.05-10 microg/mL); and the LOD and LOQ in water were 0.006 and 0.01 microg/mL, respectively. Good intra- and inter-assay precision was obtained, always <8%. The method is simple, fast and sensitive enough for the rapid diagnosis of cyanide intoxication in clinical and forensic toxicology.  相似文献   

15.
An isocratic high-performance liquid-chromatographic method has been developed for the simultaneous determination of disulfiram and bupropion in human plasma samples. Analyses were carried out on a C8 reversed-phase column using a mobile phase composed of 50% acetonitrile and 50% aqueous phosphate buffer, containing triethylamine. Diode-array detection was used, operating at a wavelength of 250 nm. For the clean-up of plasma samples, a solid phase extraction procedure, based on C2 cartridges, was implemented. Extraction yields of the analytes were satisfactory, being always higher than 84%. The calibration curve was linear over the 5–500 ng mL-1 plasma concentration range for both disulfiram and bupropion. The method showed a high sensitivity (limit of detection of 1.5 ng mL-1) and satisfactory precision, selectivity and accuracy. The application to human plasma samples obtained from some alcohol and nicotine abusers also gave good results.  相似文献   

16.
A new, long-path integrated optical (IO) sensor for the detection of non-polar organic substances is described. The sensing layer deposited on a planar multimode IO structure is built by a suitable silicone polymer with lower refractive index (RI). It acts as a hydrophobic matrix for the reversible enrichment of non-polar organic contaminants from water or air. Light from the near-infrared (NIR) range is coupled into the planar structure and the evanescent wave part of the light field penetrating into the silicone layer interacts with the enriched organic species. As a result, light is absorbed at the characteristic frequencies of the corresponding C-H, N-H or O-H overtone and combination band vibrations of the analytes. To perform evanescent field absorbance (EFA) measurements, the arc-shaped strip waveguide structure of 172 mm interaction length was adapted to a tungsten-halogen lamp and an InGaAs diode array spectrograph over gradient index fibers. Dimethyl-co-methly(phenyl)polysiloxanes with varying degrees of phenylation were prepared and used as sensitive coating materials for the IO structure. Light attenuation in the arc-shaped waveguides is high and typical insertion losses in the range of 14–18 dB were obtained. When the coated sensors were brought in contact with aqueous samples, the light transmission decreases, which is due to the formation of H2O micro-emulsions in the silicone superstrates. Nevertheless, after reaching constant light transmissions, absorbance spectra of aqueous trichloroethene samples were successfully collected. For gas measurements, where water cross sensitivity problems are absent, the sensitivity of the IO device for trichloroethene was tested as a function of the RI of the silicone superstrate. The slope of the TCE calibration function increases by a factor of 10 by using a poly(methylphenylsiloxane) layer with a RI of 1.449 instead of poly(dimethylsiloxane) (RI: 1.41). A comparison of the IO-EFA and an earlier developed fiber-optic EFA sensor for trichloroethene measurements in the gas phase showed an increase in sensitivity per unit length of the waveguide by a factor of up to 120.  相似文献   

17.
A new method for quantification of 12 nitroaromatic compounds including 2,4,6‐trinitrotoluene, its metabolites and 2,4,6‐trinitrophenyl‐N‐methylnitramine with microextraction by packed sorbent followed by gas chromatography and mass spectrometric detection in environmental and biological samples is developed. The microextraction device employs 4 mg of C18 silica sorbent inserted into a microvolume syringe for sample preparation. Several parameters capable of influencing the microextraction procedure, namely, number of extraction cycles, washing solvent, volume of washing solvent, elution solvent, volume of eluting solvent and pH of matrix, were optimized. The developed method produced satisfactory results with excellent values of coefficient of determination (R2 > 0.9804) within the established calibration range. The extraction yields were satisfactory for all analytes (> 89.32%) for aqueous samples and (> 87.45%) for fluidic biological samples. The limits of detection values lie in the range 14–828 pg/mL.  相似文献   

18.
An imprinted fluorescent sensor was fabricated based on SiO2 nanoparticles encapsulated with a molecularly imprinted polymer containing allyl fluorescein. High fluorine cypermethirin as template molecules, methyl methacrylate as functional monomer, and allyl fluorescein as optical materials synthesized a core‐shell fluorescent molecular imprinted sensor, which showed a high and rapid sensitivity and selectivity for the detection of τ‐fluvalinate. The sensor presented appreciable sensitivity with a limit of 13.251 nM, rapid detection that reached to equilibrium within 3 min, great linear relationship in the relevant concentration range from 0 to 150 nM, and excellent selectivity over structural analogues. In addition, the fluorescent sensor demonstrated desirable regeneration ability (eight cycling operations). The molecularly imprinted polymers ensured specificity, while the fluorescent dyes provided the stabile sensitivity. Finally, an effective application of the sensor was implemented by the detection of τ‐fluvalinate in real samples from vodka. The molecularly imprinted fluorescent sensor showed a promising potential in environmental monitoring and food safety.  相似文献   

19.
Although photooxidation has previously been shown to be successful in removing organic contaminants from water, methods combining the rapid photooxidation of the desired contaminant with easy catalyst manipulation and removal are few and far between. In the absence of an easy means of catalyst removal, the photooxidation process becomes more costly and time consuming, and photocatalysis cannot be employed as an in situ method for the remediation of aqueous organic contaminants. In this study, the photocatalyst was added to an aqueous trichloroethylene (TCE) solution in the form of TiO2-coated buoyant microspheres. The solution, placed in a flow-cell photoreactor along with the buoyant catalyst, was irradiated with a UV-filtered Xenon light source. Limited sample sizes necessitated the development of a low-cost headspace GC/MS analysis method, utilizing a standard direct-injection autosampler. This analytical technique aptly monitored reaction progress and indicated that aqueous TCE concentration decreases by nearly 90% in the first hour of irradiation. Subsequent solvent extraction GC/MS analysis indicated that the TCE is initially sorbed by the photocatalyst spheres, but as irradiation continued, TCE is removed from the catalyst spheres surfaces. During the course of irradiation, the expected TCE mineralization product hydrochloric acid appeared, as indicated by a decrease in pH and ion chromatography analysis. The microsphere-born catalyst was easily removed from the treated solution by filtration. Thus, it is possible that a method for effective, low-cost in situ photooxidation of aqueous organic contaminants will be realized in the near future.  相似文献   

20.
Solid-phase microextraction (SPME) was applied, in conjunction with gas chromatography–mass spectrometry, to the analysis of volatile organic compounds (VOCs) in human breath samples without requiring exhaled breath condensate collection. A new procedure, exhaled breath vapor (EBV) collection, involving the active sampling and preconcentration of a breath sample with a SPME fiber fitted inside a modified commercial breath-collection device, the RTube™, is described. Immediately after sample collection, compounds are desorbed from the SPME fiber at 250 °C in the GC-MS injector. Experiments were performed using EBV collected at −80 °C and at room temperature, and the results compared to the traditional method of collecting exhaled breath condensate at −80 °C followed by passive SPME sampling of the collected condensate. Methods are compared in terms of portability, ease-of-use, speed of analysis, and detection limits. The need for a clean air supply for the study subjects is demonstrated using several localized sources of VOC contaminants including nail polish, lemonade, and gasoline. Various simple methods to supply clean inhaled air to a subject are presented. Chemical exposures are used to demonstrate the importance of providing cleaned air (organic vapor respirator) or an external air source (tubing stretched to a separate room). These techniques allow for facile data interpretation by minimizing background contaminants. It is demonstrated herein that this active SPME breath-sampling device provides advantages in the forms of faster sample collection and data analysis, apparatus portability and avoidance of power or cooling requirements, and performance for sample collection in a contaminated environment.   相似文献   