首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
In X-ray photoelectron spectroscopy (XPS) Ar+ ion sputtering is usually used for depth profiling. However, for such samples as organic coatings, this is not feasible because of degradation. Also, measurement of a depth profile on a conventionally prepared cross-section is not possible if, for example, sample thickness is below the smallest available measurement spot size of the XPS system. In our approach we used a rotary microtome to cut samples under a shallow tilting angle of 0.5° to obtain an extended cross-section suitable for XPS investigations. We also used liquid nitrogen cooling to ensure an exposed area of higher quality: topography measurements with a novel optical 3D microscope and by atomic force microscopy revealed the linearity of the inclined sections. With our cryo ultra-low-angle microtomy (cryo-ULAM) preparation technique we were able to determine, by XPS, elemental and chemical gradients within a 25 μm thick polyester-based organic coating deposited on steel. The gradients were related to, for example, depletion of the crosslinking agent in the sub-surface region. Complementary reflection electron energy-loss spectroscopy measurements performed on the cryo-ULAM sections also support the findings obtained from the XPS depth profiles.
Figure
Top view of the sample as imaged in 3D by FF-OCM is shown in a). In b) a side view of the 3D sample structure simultaneously exhibiting the coating surface and substrate-coating interface is depicted. Compositional XPS-depth profile of the coating prepared by cryo-ULAM is shown in c)  相似文献   

2.
An amperometric biosensor for hydrogen peroxide (H2O2) has been constructed by immobilizing cytochrome c on an indium/tin oxide (ITO) electrode modified with a macroporous material. Cyclic voltammetry showed that the direct and quasi-reversible electron transfer of cytochrome c proceeds without the need for an electron mediator. A surface-controlled electron transfer process can be observed with an apparent heterogeneous electron-transfer rate constant (ks) of 29.2?s?1. The biosensor displays excellent electrocatalytic responses to the reduction of H2O2 to give amperometric responses that increase steadily with the concentration of H2O2 in the range from 5???M to 2?mM. The detection limit is 0.61???M at pH?7.4. The apparent Michaelis-Menten constant (Km) of the biosensor is 1.06?mM. This investigation not only provided a method for the direct electron transfer of cytochrome c on macroporous materials, but also established a feasible approach for durable and reliable detection of H2O2.
Figure
Biosensor for hydrogen peroxide was developed by immobilizing cytochrome c in the macroporous ordered silica foam (MOSF) through the electrostatic interaction. The achievement of the direct electron transfer between cytochrome c and electrode surface indicated that the MOSF modified electrode displayed good affinity and biocompatibility for cytochrome c.  相似文献   

3.
We report on an amperometric biosensor for hydrogen peroxide. It is obtained via layer-by-layer assembly of ordered mesoporous carbon nanospheres and poly(diallyldimethylammonium) on the surface of an indium tin oxide (ITO) glass electrode and subsequent adsorption of cytochrome c. UV–vis absorption spectroscopy was applied to characterize the process of forming the assembled layers. Cyclic voltammetry revealed a direct and quasi-reversible electron transfer between cytochrome c and the surface of the modified ITO electrode. The surface-controlled electron transfer has an apparent heterogeneous electron-transfer rate constant (k s ) of 5.9?±?0.2?s?1 in case of the 5-layer electrode. The biosensor displays good electrocatalytic response to the reduction of H2O2, and the amperometric signal increase steadily with the concentration of H2O2 in the range from 5?μM to 1.5?mM. The detection limit is 1?μM at pH 7.4. The apparent Michaelis-Menten constant (K m ) of the sensor is 0.53?mM. We assume that the observation of a direct electron transfer of cytochrome c on mesoporous carbon nanospheres may form the basis for a feasible approach for durable and reliable detection of H2O2.
Figure
An amperometric biosensor for hydrogen peroxide has been fabricated via layer-by-layer assembly of mesoporous carbon nanospheres and polyelectrolyte on ITO electrode surface for the adsorption of cytochrome c. The direct electrochemistry and electrocatalytic activity of cytochrome c was achieved on the multilayer-assembled electrode, indicating a good affinity and biocompatibility of mesoporous carbon nanospheres for cytochrome c.  相似文献   

4.
We report on a nanocomposite based genosensor for the detection of Neisseria gonorrhoeae, a bacterium causing the sexually transmitted disease gonorrhoea. Amino-labeled probe DNA was covalently immobilized on electrochemically prepared polyaniline and iron oxide (PANI-Fe3O4) nanocomposite film on an indium tin oxide (ITO) electrode. Scanning electron microscopy, transmission electron microscopy, electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) techniques have been employed to characterize surface of the modified electrode. The genosensor has detection limits of 1?×?10-15 M and 1?×?10-17 M, respectively, using the EIS and DPV techniques. This biosensor can discriminate a complementary sequence from a single-base mismatch and from non-complementary DNA, and has been utilized for detection of DNA extracted from N. gonorrhoeae culture, and from patient samples with N. gonorrhoeae. It is found to exhibit good specificity for N. gonorrhoeae species and shows no response towards non-gonorrhoeae type of Neisseria species (NgNs) and other gram-negative bacterias (GNBs). The affinity constant for hybridization calculated using the Langmuir adsorption isotherm model is found to be 3.39?×?108 M-1.
Figure
Electrochemically deposited nanostructured platform for Neisseria gonorrhoeae detection.  相似文献   

5.
We have constructed a new electrochemical biosensor by immobilization of hemoglobin (Hb) and ZnWO4 nanorods in a thin film of chitosan (CTS) on the surface of carbon ionic liquid electrode. UV–vis and FT-IR spectra reveal that Hb remains in its native conformation in the film. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry. A pair of well-defined redox peaks appears which indicates direct electron transfer from the electrode. The presence of CTS also warrants biocompatibility. The electron transfer coefficient and the apparent heterogeneous electron transfer rate constant were calculated to be 0.35 and 0.757 s?1, respectively. The modified electrode displays good electrocatalytic activity for the reduction of trichloroacetic acid with the detection limit of 0.613 mmol L?1 (3σ). The results extend the protein electrochemistry based on the use of ZnWO4 nanorods.
Figure
A ZnWO4 nanorods and hemoglobin nanocomposite material modified carbon ionic liquid electrode was used as the platform for the construction of an electrochemical hemoglobin biosensor.  相似文献   

6.
We describe the implementation and characterization of activated ion electron transfer dissociation (AI-ETD) on a hybrid QLT-Orbitrap mass spectrometer. AI-ETD was performed using a collision cell that was modified to enable ETD reactions, in addition to normal collisional activation. The instrument manifold was modified to enable irradiation of ions along the axis of this modified cell with IR photons from a CO2 laser. Laser power settings were optimized for both charge (z) and mass to charge (m/z) and the instrument control firmware was updated to allow for automated adjustments to the level of irradiation. This implementation of AI-ETD yielded 1.6-fold more unique identifications than ETD in an nLC-MS/MS analysis of tryptic yeast peptides. Furthermore, we investigated the application of AI-ETD on large scale analysis of phosphopeptides, where laser power aids ETD, but can produce b- and y-type ions because of the phosphoryl moiety’s high IR adsorption. nLC-MS/MS analysis of phosphopeptides derived from human embryonic stem cells using AI-ETD yielded 2.4-fold more unique identifications than ETD alone, demonstrating a promising advance in ETD sequencing of PTM containing peptides.
Figure
?  相似文献   

7.
We report on a novel matrix of solgel organic–inorganic nanocomposite that was fabricated from silica sol gel and dextran. It was used for the immobilization of horseradish peroxidase (HRP) to give a biosensor for hydrogen peroxide (H2O2). The sensor film was characterized by Fourier transform infrared and UV–vis spectroscopy with respect to structural features and the conformation of the enzyme. The topographies of the surface of the electrode were investigated by field emission scanning electron microscopy. The biosensor was used to determine H2O2 quantitatively in the presence of Methylene blue as a mediator with high electron transfer efficiency. A pair of stable and well defined quasi-reversible redox peaks of the HRP [Fe (III)]/HRP [Fe (II)] redox couple was observed at pH 7.0. The biosensor responds to H2O2 in the 0.5 mM to 16.5 mM concentration range, and the limit of detection is 0.5 mM.
Figure
A synthesized novel silica-dextran nanocomposite provides three dimensional interfaces for immobilization of HRP which maintains the characteristic structure and enhances the catalytic activity.  相似文献   

8.
Microextraction of organic or inorganic analytes using solidified floating drops of organic solvents is a fairly new method that is simple and rapid, and requires only small quantities of solvents and reagents. This review (with 109 references) covers published work up to Sep. 2012, and describes how the method was combined with analytical techniques such as GC, HPLC, ICP-OES and electrothermal atomic absorption spectrometry. We discuss basic principles and the main parameters that affect the extraction efficiency, and give specific applications of the technique.
Figure
Schematic diagram of liquid-phase microextraction based on solidified floating drops of organic solvents  相似文献   

9.
The interaction between papain and two typical ionic liquids (ILs), 1-octyl-3-methylimidazolium chloride ([C8mim]Cl) and 1-butyl-3-methylimidazolium chloride ([C4mim]Cl), was investigated by using fluorescence spectroscopy technique at a pH value of 7.4. The results suggested that ILs could quench the intrinsic fluorescence of papain probably via a static quenching mechanism. The binding constants were determined by employing the fluorescence quenching method. They were very small compared with that of volatile organic solvents, indicating that only very weak interaction between ILs and papain existed. The Gibbs free energy change (?G), enthalpy change (?H), and entropy change (?S) during the interaction of papain and ILs were estimated. Negative values of these parameters indicated that the interaction between ILs and papain was a spontaneous process, also implying that hydrogen bonding and van der Waals forces played important roles in the interaction processes.
Figure
Three-dimensional fluorescence spectrum of papain (0.2?g?L-1)  相似文献   

10.
In the present study, the molecular chain changes and structural transitions of partially hydrolyzed poly(vinyl alcohol) (PVA) having a 12 mol% acetate unit were analyzed by moving-window two-dimensional (MW2D) correlation infrared spectroscopy combined with differential scanning calorimetry and thermogravimetric analysis. The results show the glass-transition temperature (T g ) of PVA is clearly distinguished by MW2D correlation infrared spectroscopy, and the acetate groups start to be eliminated around the melting temperature, whereas the free water molecules in PVA are eliminated above T g. The correlation movements of the O–H stretching modes, including the free hydroxyl groups and the hydrogen bonds, are clearly determined using MW2D correlation infrared spectroscopy. The spectral variations in the C=O stretching region caused by the elimination of the acetate unit from polymer chains are also discussed on the basis of the results of the MW2D correlation analysis. Such results cannot be obtained by traditional infrared spectroscopy owing to the complex overlapping peaks.
Figure
The structural variations of partially hydrolyzed poly(vinyl alcohol) studied by moving-window two-dimensional correlation infrared spectroscopy  相似文献   

11.
A novel strategy for preparation of a boronate affinity hybrid monolith was developed using a Cu(I)-catalyzed 1,3-dipolar azide–alkyne cycloaddition (CuAAC) reaction of an alkyne–boronate ligand with an azide-functionalized monolithic intermediate. An azide-functionalized hybrid monolith was first synthesized via a single-step procedure to provide reactive sites for click chemistry; then the alkyne–boronate ligands were covalently immobilized on the azide-functionalized hybrid monolith via an in-column CuAAC reaction to form a boronate affinity hybrid monolith under mild conditions. The boronate affinity monolith was characterized and evaluated by means of elemental analysis, Fourier transform infrared spectroscopy, and scanning electron microscopy. The boronate affinity hybrid monolith exhibited excellent specificity toward nucleosides and glycoproteins, which were chosen as test cis-diol-containing compounds under neutral conditions. The binding capacity of the monolith for the glycoprotein ovalbumin was 2.36 mg?·?g-1 at pH 7.0. The practicability of the boronate affinity hybrid monolithic material was demonstrated by specific capture of the glycoproteins ovalbumin and ovotransferrin from an egg sample.
Figure
A novel strategy for preparation of boronate affinity hybrid monolith was developed by utilizing Cu(I)-catalyzed 1,3-dipolar azide-alkyne cycloaddition reaction (CuAAC). The obtained boronate affinity hybrid monolith exhibited excellent performance for isolation and enrichment of nucleosides and glycoproteins and was successfully employed to specific capture of glycoproteins from the egg sample  相似文献   

12.
The chemical transformation of the polar chloroaluminum phthalocyanine, AlClPc, to μ-(oxo)bis(phthalocyaninato)aluminum(III), (PcAl)2O, in thin films on indium tin oxide is studied and its influence on the molecular orientation is discussed. The studies were conducted using complementary spectroscopic techniques: Raman spectroscopy, X-ray photoelectron spectroscopy, and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy. In addition, density functional theory calculations were performed in order to identify specific vibrations and to monitor the product formation. The thin films of AlClPc were annealed in controlled environmental conditions to obtain (PcAl)2O. It is shown that the chemical transformation in the thin films can proceed only in the presence of water. The influence of the reaction and the annealing on the molecular orientation was studied with Raman spectroscopy and NEXAFS spectroscopy in total electron yield and partial electron yield modes. The comparison of the results obtained from these techniques allows the determination of the molecular orientation of the film as a function of the probing depth.
Illustration of the dimerization reaction of MClPc to (PcM)2O.  相似文献   

13.
Nanocomposites composed of cuprous oxide (Cu2O) and graphene were synthesized via reduction of copper(II) in ethylene glycol. This material possesses the specific features of both Cu2O and graphene. Its morphology was characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy, and X-ray photoelectron spectroscopy. Cyclic voltammetry was used to evaluate the electrochemical response of a glass carbon electrode (GCE) modified with the nanocomposite towards dopamine (DA). Compared to the bare GCE, the Cu2O nanoparticles modified electrode and the graphene modified electrode, the nanocomposites modified electrode displays high electrocatalytic activity in giving an oxidation peak current that is proportional to the concentration of DA in the range from 0.1 to 10???M,with a detection limit of 10?nM (S/N?=?3). The modified electrode shows excellent selectivity and sensitivity even in the presence of high concentration of uric acid and can be applied to determine DA in real samples with satisfactory results.
Figure
Cu2O/Graphene nanocomposites were successfully prepared, Cu2O particles were uniformly distributed on transparent graphene and no particles scattered out of the supports. Electrochemical experiment results indicate that the nanocomposites modified electrode displays a wide linear region, excellent selectivity and sensitivity to DA.  相似文献   

14.
We have immobilized iminodiacetic acid on mesoporous Fe3O4@SiO2 microspheres and used this material for efficient and cost effective method of magnetic solid phase extraction (SPE) of trace levels of Cd, Mn and Pb. The microspheres were characterized by infrared spectroscopy, scanning electron microscopy and transmission electron microscopy. The loaded microspheres can be easily separated from the aqueous sample solution by applying an external magnetic field. The effects of pH, sample volume, concentration and volume of eluent, and of interfering ions were investigated in detail. The method has detection limit of 0.16, 0.26 and 0.26?ng?L?1 for the ions of Cd, Mn and Pb, respectively, and the relative standard deviations (RSDs, c?=?1???g?L?1, n?=?7) are 4.8%, 4.6% and 7.4%. The method was successfully applied to the determination of these metals in biological and environmental samples using ICP-MS. Two certified reference materials were analyzed, and the results coincided well with the certified values.
Figure
Mesoporous Fe3O4@SiO2@IDA magnetic particles for fast and selective magnetic solid phase extraction of trace Cd, Mn and Pb from environmental and biological samples followed by inductively coupled plasma mass spectrometry detection.  相似文献   

15.
A new hydrophilic and nonionic poly(2-vinyloxazoline)-grafted silica (Sil-VOX n ) phase was synthesized and applied for the separation of nucleosides and nucleobases in hydrophilic interaction chromatography (HILIC). Polymerization and immobilization onto silica were confirmed by using characterization techniques including 1H NMR spectroscopy, elemental analysis, and diffuse reflectance infrared Fourier transform spectroscopy. The hydrophilicity or wettability of Sil-VOX n was observed by measuring the contact angle (59.9°). The chromatographic results were compared with those obtained with a conventional HILIC silica column. The Sil-VOX n phase showed much better separation of polar test analytes than the silica column, and the elution order was different. Differences in selectivity between these two columns indicate that the stationary phase cannot function merely as an inert support for a water layer into which the solutes are partitioned from the bulk mobile phase. To elucidate the interaction mechanism, the separation of dihydroxybenzene isomers was performed on both columns in normal-phase liquid chromatography. Sil-VOX n was very sensitive to the dipole moments of the positional isomers of polycyclic aromatic compounds in normal-phase liquid chromatography. The interaction mechanism for Sil-VOX n in HILIC separation is also described.
Figure
Separation of nucleosides and nucleobases with Sil-VOXn (bottom) and a commercial silica column (top). Mobile phase of acetonitrile and 20 mM ammonium acetate (9:1, v/v). Flow rate 1 ml min-1, column temperature 25 °C. The analytes were as follows 5-iodouracil (1), thymine (2), uracil (3), 4,6-diaminopyrimidine (4), uridine (5), adenosine 2 (6), cytosine (7), cytidine (8), and guanosine (9)  相似文献   

16.
We show that the addition of white dextrin during the electrochemical deposition of platinum nanostructures (nano-Pt) on a glassy carbon electrode (GCE) results in an electrochemically active surface that is much larger than that of platinum microparticles prepared by the same procedure but in the absence of dextrin. The nano-Pt deposits are characterized by scanning electron microscopy (SEM), energy dispersive spectroscopy, and electrochemical methods. The SEM images reveal deposits composed of mainly nanoparticles and short nanorods. The GCE was applied as a novel and cost-effective catalyst for methanol oxidation. The use of nano-Pt improves the electrocatalytic activity and the stability of the electrodes.
Figure
(A) SEM image of the Pt nanostructures. (B) Electrochemical responses of the Pt nanostructures (solid line) and Pt microparticles (line) in 1.4 M CH3OH + 0.5 M H2SO4 solution at υ?=?50 mV s?1. Novel Pt nanostructures were electrodeposited at the surface of glassy carbon electrode in the presence of white dextrin as an additive, which exhibit high electrocatalytic activity towards methanol oxidation due to their highly electrochemically active surface area.  相似文献   

17.
Platinum nanoparticles (Pt-NPs) with sizes in the range from 10 to 30 nm were synthesized using protein-directed one-pot reduction. The model globular protein bovine serum albumin (BSA) was exploited as the template, and the resulting BSA/Pt-NPs were studied by transmission electron microscopy, energy dispersive X-ray spectroscopy, and resonance Rayleigh scattering spectroscopy. The modified nanoparticles display a peroxidase-like activity that was exploited in a rapid method for the colorimetric determination of hydrogen peroxide which can be detected in the 50 μM to 3 mM concentration range. The limit of detection is 7.9 μM, and the lowest concentration that can be visually detected is 200 μM.
Figure
Pt-NPs were synthesized using BSA-directed one-pot reduction and BSA/Pt-NPs composite can effectively catalyze the oxidation of TMB producing blue solution in the presence of H2O2.  相似文献   

18.
19.
Ferritin was immobilized on a glassy carbon electrode with electrodeposited cobalt oxide nanoparticles, and its direct electron transfer behavior was studied. It exhibits a pair of redox peaks due to direct electron transfer between ferritin and the nanoparticles. Electrochemical parameters including the formal potential (E0??), the charge transfer coefficient (??), and the apparent heterogeneous electron transfer rate constant (ks) were determined. The sensor displays excellent biocatalytic activity in terms of reduction of hydrogen peroxide, and this was applied to electrochemical sensing of hydrogen peroxide.
Figure
In this work, cobalt oxide nanoparticles were electrodeposited on the surface of an electrode for immobilization of ferritin molecules to prepare hydrogen peroxide biosensor. The immobilized protein molecules still preserve their biological activities and have great capability in catalyzing the reduction of hydrogen peroxide.  相似文献   

20.
We report on a novel amperometric glassy carbon biosensing electrode for glucose. It is based on the immobilization of a highly sensitive glucose oxidase (GOx) by affinity interaction on carbon nanotubes (CNTs) functionalized with iminodiacetic acid and metal chelates. The new technique for immobilization is exploiting the affinity of Co(II) ions to the histidine and cysteine moieties on the surface of GOx. The direct electrochemistry of immobilized GOx revealed that the functionalized CNTs greatly improve the direct electron transfer between GOx and the surface of the electrode to give a pair of well-defined and almost reversible redox peaks and undergoes fast heterogeneous electron transfer with a rate constant (k s) of 0.59?s?1. The GOx immobilized in this way fully retained its activity for the oxidation of glucose. The resulting biosensor is capable of detecting glucose at levels as low as 0.01?mM, and has excellent operational stability (with no decrease in the activity of enzyme over a 10?days period). The method of immobilizing GOx is easy and also provides a model technique for potential use with other redox enzymes and proteins.
Figure
This paper reports a novel amperometric biosensor for glucose based on the immobilization of the glucose oxidase (GOx) by affinity interaction on carbon nanotubes (CNTs) functionalized with iminodiacetic acid and metal chelates. The GOx immobilized in this way fully retained its activity for the oxidation of glucose. The resulting biosensor exhibited high sensitivity, good stability and selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号