首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Stir bar sorptive extraction with in-situ derivatization using 2,3-diaminonaphthalene (DAN) followed by liquid desorption and high performance liquid chromatography with diode array detection (SBSE(DAN)in-situ-LD-HPLC-DAD) was developed for the determination of glyoxal (Gly) and methylglyoxal (MGly) in environmental and biological matrices. DAN proved very good specificity as in-situ derivatising agent for Gly and MGly in aqueous media, allowing the formation of adducts with remarkable sensitivity, selectivity and the absence of photodegradation. Assays performed on spiked (1.0 microg L(-1)) water samples, under convenient experimental conditions, yielded recoveries of 96.2+/-7.9% for Gly and 96.1+/-6.4% for MGly. The analytical performance showed good accuracy, suitable precision (<12.0%), low detection limits (15 ng L(-1) for Gly and 25 ng L(-1) for MGly adducts) and excellent linear dynamic ranges (r2>0.99) from 0.1 to 120.0 microg L(-1). By using the standard addition method, the application of the present method to tap and swimming-pool water, beer, yeast cells suspension and urine samples allowed very good performance at the trace level. The proposed methodology proved to be a feasible alternative for routine quality control analysis, showing to be easy to implement, reliable, sensitive and with a low sample volume requirement to monitor Gly and MGly in environmental and biological matrices.  相似文献   

2.
Polar vinyl monomers have been used for the synthesis of several polymer monoliths, to serve as novel coatings for stir bar sorptive extraction; the monovinyl monomers 2‐hydroxyethyl methacrylate (HEMA) and poly(ethylene glycol) monomethacrylate) (PEGMA) were copolymerized with (apolar) divinylbenzene (DVB) and/or pentaerythritol triacrylate (PETRA), both of which are cross‐linking agents. After the optimization of the most important synthesis parameters, which included the ratio between total monomers and porogen, the nature of the porogen, and the monomer ratios, inter alia, three mechanically stable, polar monolithic coatings for stir bar sorptive extraction were obtained that were based on poly(HEMA‐co‐DVB), poly(HEMA‐co‐PETRA), and poly(PEGMA‐co‐PETRA). Thereafter, and in order to evaluate the hydrophilicity of the resulting monoliths, they were applied as materials in the stir bar sorptive extraction of a group of emerging pollutants with a wide range of polarities. The results showed that both the poly(HEMA‐co‐DVB) and poly(PEGMA‐co‐PETRA) materials could be used to extract both polar and nonpolar compounds by stir bar sorptive extraction, in an effective manner. Taking into account the desired chemical and morphological properties, as well as the extraction efficiencies, the poly(PEGMA‐co‐PETRA) material seemed to be a particularly promising monolith for application as a novel coating in stir bar sorptive extraction.  相似文献   

3.
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SBSE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 μg/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.  相似文献   

4.
Application of stir bar sorptive extraction for wine analysis   总被引:4,自引:0,他引:4  
Stir bar sorptive extraction (SBSE) coupled with gas chromatography/mass spectrometry (GC/MS) was used to analyse wine samples for three applications: flavour and compositional analysis; 2,4,6-trichloroanisole (TCA), a common off-aroma in wine; and agrochemicals. SBSE was found to be orders of magnitude more sensitive than modern conventional methodology, allowing for lower detection and quantitation levels, and improved confirmation of identity; SBSE often gave better signal to noise in scan mode than other methods in selective ion monitoring (SIM) mode. With the help of their characteristic mass spectra all agrochemicals could be identified unambiguously at concentrations of 10 microg L(-1) in wine and a further 100 constituents were detected in a Cabernet Sauvignon sample. Thus it is now possible to analyse complex samples such as wine by scan mode, with better confirmation of identity, and without sacrificing sensitivity, where previously SIM methodology had to be used.  相似文献   

5.
The determination of taints in food products currently can involve the use of several sample extraction techniques, including direct headspace (DHS), steam distillation extraction (SDE) and more recently solid phase microextraction (SPME). Each of these techniques has disadvantages, such as the use of large volumes of solvents (SDE), or limitations in sensitivity (DHS), or have only been applied to date for determination of individual or specific groups of tainting compounds (SPME). The use of stir bar sorptive extraction (SBSE) has been evaluated as a quantitative screening method for unknown tainting compounds in foods. A range of commonly investigated problem compounds, with a range of physical and chemical properties, were examined. The method was optimised to give the best response for the majority of compounds and the performance was evaluated by examining the accuracy, precision, linearity, limits of detection and quantitation and uncertainties for each analyte.For most compounds SBSE gave the lowest limits of detection compared to steam distillation extraction or direct headspace analysis and in general was better than these established techniques. However, for methyl methacrylate and hexanal no response was observed following stir bar extraction under the optimised conditions.The assays were carried out using a single quadrupole GC-MS in scan mode. A comparison of acquisition modes and instrumentation was performed using standards to illustrate the increase in sensitivity possible using more targeted ion monitoring or a more sensitive high resolution mass spectrometer. This comparison illustrated the usefulness of this approach as an alternative to specialised glassware or expensive instrumentation. SBSE in particular offers a ‘greener’ extraction method by a large reduction in the use of organic solvents and also minimises the potential for contamination from external laboratory sources, which is of particular concern for taint analysis.  相似文献   

6.
A highly sensitive method was developed for the simultaneous determination of ten sulfonamides in pork and chicken samples by monolith-based stir bar sorptive extraction (SBSE) coupled to high-performance liquid chromatography tandem mass spectrometry. The samples were freeze-dried and extracted by acetonitrile, then enriched and further extracted by SBSE which was based on poly(vinylphthalimide-co-N,N-methylenebisacrylamide) monolith (SBSE-VPMB) as coating. To achieve optimum extraction performance of SBSE for sulfonamides, several parameters, including pH value and ionic strength in the sample matrix and extraction and desorption time, were investigated in detail. Under the optimal conditions, the limits of detection (S/N?=?3) for target sulfonamides were 1.2–6.1 ng/kg in pork and 2.0–14.6 ng/kg in chicken, respectively. Real samples spiked at the concentration of 0.5 and 5.0 μg/kg showed recoveries above 55 % and relative standard deviations below 12 %. At the same time, the extraction performances of target sulfonamides on SBSE-VPMB were compared with other SBSE based on porous monolith and commercial SBSE.
Figure
?  相似文献   

7.
A novel anionic exchange stir bar sorptive extraction (SBSE) coating based on poly(2-(methacryloyloxy)ethyltrimethylammonium chloride-co-divinylbenzene) monolithic material for the extraction of inorganic anion was prepared. The effect of preparation conditions such as ratio of functional monomer to cross-linker, content of porogenic solvent on the extraction efficiencies were investigated in detailed. The monolithic material was characterized by elemental analysis, scanning electron microscopy and infrared spectroscopy. In order to investigate the extraction capacity of the new coating for inorganic anion, the new SBSE was combined with ionic chromatography with conductivity detection, Br, NO3, PO43− and SO42− were selected as detected solutes. Several extractive parameters, including pH value and ionic strength in sample matrix, desorption solvent, extraction and desorption time were optimized. The results showed that strongly ionic strength did not favor the extraction of anlaytes. Under the optimum experimental conditions, low detection limits (S/N = 3) and quantification limits (S/N = 10) of the proposed method for the target anions were achieved within the range of 0.92–2.62 and 3.03–9.25 μg/L, respectively. The method also showed good linearity, simplicity, practicality and low cost for the extraction inorganic anions. Finally, the proposed method was successfully used to detect the two different trademarks of commercial purified water with satisfactory recovery in the range of 70.0–92.6%. To the best of our knowledge, this is the first to use SBSE to enrich inorganic anions.  相似文献   

8.
Analysis of wine primary aroma compounds by stir bar sorptive extraction   总被引:2,自引:0,他引:2  
A. Zalacain  G.L. Alonso 《Talanta》2007,71(4):1610-1615
Due to the great importance of some primary aroma compounds on wine quality, these compounds which includes terpenes, C13-norisoprenoids and C6 compounds, have been analyzed by stir bar sorptive extraction (SBSE) followed by a thermal desorption-gas chromatography-mass spectrometry analysis. The stir bar sorptive extraction method was optimized in terms of temperature, time, pH and NaCl addition. The best SBSE sorption kinetics for the target analytes were obtained after submitting the solutions to 60 °C during 90 min. The addition of sodium chloride did not enhance the volatile extraction. The method proposed showed good linearity over the concentration range tested, with correlation coefficients higher than 0.98 for all the analytes. The reproducibility and repeatability of the method was estimated between 0.22 and 9.11%. The detection and quantification limits of all analytes were lower than their respective olfactory threshold values. The application of this SBSE method revealed that monovarietal white wines were clearly separated by two canonic discriminating functions when grape varieties were used as differentiating variable, the first of which explained 98.4% of the variance. The compounds which contributed most to the differentiation were limonene, linalool, nerolidol and 1-hexanol.  相似文献   

9.
New inorganic–organic hybrid materials were synthesized by hydrolysis and condensation of cyanopropyltriethoxysilane (CNPrTEOS) and polydimethylsiloxane (PDMS) in the presence of hydrochloric acid, HCl catalyst and methyl trimethylmethoxysilane as precursor via sol–gel method and coated on glass encased stir bar for use in stir bar sorptive extraction (SBSE). The cyano part provides polar moiety, which may improve the extraction of polar analytes. The physico-chemical properties and extraction ability of PDMS-CNPrTEOS-derived hybrid coatings can be fine tuned via manipulation of solvents (tetrahydrofuran (THF)-based and dichloromethane (DCM)-based) and PDMS-CNPrTEOS molar concentrations during the sol synthesis. Clear, homogeneous PDMS-CNPrTEOS-derived hybrid sols were obtained using THF and DCM at optimized molar ratios. The optimized molar ratios of THF:CNPrTEOS and THF:PDMS were 5:1 and 25:1, respectively. The optimized molar ratios of DCM:CNPrTEOS and DCM:PDMS were 10:1 and 70:1, respectively. FTIR spectrum showed that the intensity of the CN peak increased with increasing content of CNPrTEOS in the PDMS;CNPrTEOS-derived hybrid. The Field Emission Scanning Electron micrographs of prepared coatings revealed smooth, homogenous surfaces and crack-free coatings with film thickness of 200 nm to 2.5 μm attributing to different solvent types. All coatings prepared were thermally stable at temperature higher than 200 °C. The DCM-based PDMS-CNPrTEOS-derived coating shows more advantages in terms of physical characteristics and extraction ability compared to THF-based PDMS-CNPrTEOS-derived coatings due to higher cyano part content and its thicker coating. The PDMS-CNPrTEOS-derived hybrid coatings can be used as extraction sorbent for analysis of non steroidal anti-inflammatory drugs namely ketoprofen and diclofenac sodium in SBSE.  相似文献   

10.
A stir bar sorptive extraction method for the determination of volatile compounds in orange juices was developed. The extraction variables were optimized using a reduced two‐level factorial screening design (25‐1), and the most suitable analytical conditions for the extraction of the studied compounds were: sample volume 10 mL, extraction time 60 min, stirring speed 1800 rpm, NaCl amount 30% (weight/volume), and twister length 10 mm. The optimized method was further validated, obtaining good linearity and detection and quantification limits low enough to correctly determine the studied compounds. As well, for most of the studied compounds precision and recovery values were good. Several orange juice samples (squeezed and commercial) were extracted following the optimized extraction method and analyzed by gas chromatography coupled to mass spectrometry detection. The method has proven to be suitable for the determination of the aroma of orange juice, of which limonene was the major volatile compound in all the studied samples.  相似文献   

11.
A fast, simple, and reliable analytical method for the determination of medium‐level volatile thiols in wines is presented. Stir bar sorptive extraction using ethylene glycol‐silicone coated stir bars has been used in combination with thermal desorption gas chromatography with mass spectrometry for the analysis of 4‐mercapto‐4‐methylpentan‐2‐one, 2‐furanmethanethiol, 3‐mercaptohexyl acetate, and 3‐mercaptohexanol in wine. Optimization of the extraction technique was performed using a two‐level fractional factorial design. For the extraction step, the optimum conditions were: Ethylene glycol and silicone coated stir bars, pH at 3.5, sample volume of 25 mL, extraction time of 90 min, NaCl content 4.0 g, and stirring speed at 500 rpm. The optimized method achieved good linearity for all studied compounds (r2 > 0.995) and it provided detection limits of 21.52, 0.36, 0.73, and 2.55 μg/L for 4‐mercapto‐4‐methylpentan‐2‐one, 2‐furanmethanethiol, 3‐mercaptohexyl acetate, and 3‐mercaptohexanol, respectively. It was repeatable, with precisions lower than 18% relative standard deviation for both intraday and interday repeatability. The developed procedure is suitable for the determination of these kinds of compounds when they are present at medium concentration levels. It was finally applied to real wine samples with negative aroma derived from the high concentration levels of these compounds.  相似文献   

12.
An easy, fast and reliable analytical method is proposed for the determination of the concentration of volatile phenols (ethyl- and vinylphenols) in wines. The novel stir bar sorptive extraction (SBSE) technique is employed, following a simple and fast procedure that allows 15 samples to be extracted simultaneously using very small sample volume. Extracts are desorbed in a thermodesorption system (TDS) coupled on-line to a gas chromatograph-mass spectrometry system. The SBSE offers better recovery and linear regression coefficient (r2) for the four volatile phenols than solid-phase extraction (SPE). The mass spectrometric detection in selected ion monitoring mode contributes to the lower detection limit and good sensibility obtained with this method.  相似文献   

13.
A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues (SAs) in milk was developed by stir bar sorptive extraction (SBSE) coupling to high performance liquid chromatography with diode array detection. The analytes were concentrated by SBSE based on poly (vinylimidazole–divinylbenzene) monolithic material as coating. The extraction procedure was very simple, milk was diluted with water then directly sorptive extraction without elimination of fats and protein in samples was required. To achieve optimum extraction performance for SAs, several parameters, including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. Under the optimized experimental conditions, low detection limits (S/N = 3) quantification limits (S/N = 10) of the proposed method for the target compounds were achieved within the range of 1.30–7.90 ng/mL and 4.29–26.3 ng/mL from spiked milk, respectively. Good linearities were obtained for SAs with the correlation coefficients (R2) above 0.996. Finally, the proposed method was successfully applied to the determination of SAs compounds in different milk samples and satisfied recoveries of spiked target compounds in real samples were obtained.  相似文献   

14.
A new method using the extraction and preconcentration capabilities of stir bar sorptive extraction, combined with high-resolution gas chromatography and mass spectrometry, was developed for the determination of five selected endocrine-disrupting compounds (4-n-nonylphenol, bisphenol A, estrone, 17β-estradiol, and 17α-ethinylestradiol) in water. In situ derivatization to transform the phenolic compounds into lipophilic and volatile analytes was carried out with acetic anhydride. Two different methods of headspace derivatization to further improve the chromatographic properties of 17β-estradiol and 17α-ethinylestradiol were developed and compared. The optimized method provided good sensitivity (limits of quantitation 1.2–2.6 ng), repeatability (relative standard deviation 2–9%), and reproducibility (relative standard deviation 10–17%). Passive sampling by means of polar organic chemical integrative samplers was applied to monitor river waters used as supply sources for drinking water treatment plants in the Liguria region of Italy. The analytes showed a different distribution at the three sites considered; bisphenol A proved to be the most abundant, ranging from 185 to 459 ng per sampler.  相似文献   

15.
In this contribution, polyurethane foams are proposed as new polymeric phases for stir bar sorptive extraction (SBSE). Assays performed for polyurethane synthesis demonstrated that four series of formulations (P(1), P(2), P(3) and P(4)) present remarkable stability and excellent mechanical resistance to organic solvents. For polymer clean-up treatment, acetonitrile proved to be the best solvent under sonification, ensuring the reduction of the contamination and interferences. SBSE assays performed on these polyurethane polymers followed by liquid desorption and high-performance liquid chromatography-diode array detection (LD-HPLC-DAD) or large volume injection-capillary gas chromatography-mass spectrometry (LD-LVI-GC-MS), showed that P(2) presents the best recovery yields for atrazine, 2,3,4,5-tetrachlorophenol and fluorene, used as model compounds in water samples at a trace level. SBSE(P(2)) assays performed on this polymer mixed up with several adsorbent materials, i.e. activated carbon, a mesoporous material and a calixarene, did not bring any advantages in relation with the polymeric matrix alone. The comparison between assays performed by SBSE(P(2)) and by the conventional SBSE(PDMS) showed much better performance for the former phase on aqueous samples spiked with atrazine, 2,3,4,5-tetrachlorophenol and fluorene, in which the foremost two analytes present recovery values 3- and 10-fold higher, respectively. The polyurethanes proposed as new polymeric phases for SBSE provided powerful capabilities for the enrichment of organic compounds from aqueous matrices, showing to be indicated mainly in the case of the more polar analytes.  相似文献   

16.
Blended Scotch whisky was analysed by solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE) to study the composition of the volatiles. For SPME analysis, three different fibres were compared, poly(dimethylsiloxane) (PDMS) (100 microm). poly(acrylate) (PA) (85 microm) and divinylbenzene-Carboxen on poly(dimethylsiloxane) (DVB-CAR-(PDMS) (50/30 microm). It was found that the PDMS and DVB-CAR-PDMS fibres showed a higher enrichment capacity than PA as well as a better reproducibility. The influence of sampling time, temperature and salt addition on the enrichment of volatiles as well as the difference between liquid and headspace SPME were studied. An optimum SPME method was developed. Finally a more recent sample preparation technique, namely SBSE was evaluated to extract whisky volatiles.  相似文献   

17.
This article presents a method employing stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry for the analysis of fluoxetine in plasma samples. Ethyl chloroformate was employed as derivatizing agent producing symmetrical peaks. Parameters such as solvent polarity, time for analyte desorption, and extraction time, were evaluated. During the validation process, the developed method presented specificity, linearity (R2 > 0.99), precision (R.S.D. < 15%), and limits of quantification (LOQ) of 30 and 1.37 pg mL−1, when liquid and thermal desorption were employed, respectively. This simple and highly sensitive method showed to be adequate for the measurement of fluoxetine in typical and trace concentration levels.  相似文献   

18.
利用自制的以聚(乙烯基咪唑-二乙烯基苯)(VIDB)整体材料为涂层的固相萃取搅拌棒(VIDB-SBSE)萃取3种硝基呋喃类药物,然后与高效液相色谱-二极管阵列检测器联用建立了测定饲料和水样品中硝基呋喃类药物残留的方法。详细考察了萃取过程中萃取和解吸时间、样品基质的pH值以及离子强度等实验条件对萃取效率的影响。在最佳条件下,呋喃唑酮的线性范围为0.5~200μg/L,呋喃妥因和呋喃西林的线性范围为0.25~200μg/L,3种目标物的检出限(LO D)(S/N=3)在0.068~0.11μg/L之间,所建方法具有理想的日内和日间重现性(R SD值均小于6%)。在对饲料和实际水样的测定中,不同加标浓度呋喃唑酮、呋喃妥因和呋喃西林的回收率在80.6%~108%之间。研究表明,所建立的方法具有简便、灵敏、环境友好等特点。  相似文献   

19.
Yuling Hu 《Talanta》2010,82(2):464-4294
A novel stir bar coated with molecularly imprinted polymer (MIP) as selective extraction phase for sorptive extraction of triazine herbicides was developed. The stir bar was prepared by chemically bonding the MIP to the glass bar to improve its stability. A homogeneous and porous structure was observed on the stir bar surface. Extraction performance shows that the MIP-coated stir bar has stronger affinity to the template molecule terbuthylazine as compared with that of the reference stir bar without addition of template. Owning to the shape and structural compatibility, the obtained stir bar also demonstrated specific selectivity to the structural related-compounds of nine triazines, and thus can be applied to simultaneous determination of these compounds from complex samples coupled with high performance liquid chromatography. Four complex samples with different matrix, including rice, apple, lettuce and soil were used to evaluate this proposed method. The limits of detection obtained are in the range of 0.04-0.12 μg L−1, and the recoveries for the spiked rice, apple, lettuce and soil samples were 80.8-107.7%, 80.6-107.8%, 72.0-109.8% and 89.0-114.8% with RSD from 1.2 to 7.9%, respectively. Moreover, this MIP-coated stir bar was firm, durable and can be prepared simply and reproducibly. The developed coating method would be useful to prepare a range of selective stir bars in order to extend the applicability of stir bar sorptive extraction (SBSE) in complex sample analysis.  相似文献   

20.
Nguyen KT  Scapolla C  Di Carro M  Magi E 《Talanta》2011,85(5):2375-2384
Fast liquid chromatography coupled to triple-quadrupole tandem mass spectrometry was employed for the determination of six UV filters in seawater. The separation of the analytes was achieved in less than 5 min; polarity switching was used as four of the analytes were ionized in positive mode and the remaining two in negative mode. Two ionization sources were employed and compared: atmospheric pressure chemical ionization (APCI) gave better results than electrospray ionization (ESI) for all analytes, with higher reproducibility and lower detection limits. Therefore APCI was chosen for the determination of the analytes in seawater samples using stir bar sorptive extraction-liquid desorption (SBSE-LD).Quantitative analysis was performed in multiple reaction monitoring (MRM) mode; fragmentation pathways of the analytes with regard to the formation of the MRM ions were also proposed.For the analysis of seawater samples, calibration curves were drawn using SBSE in spiked seawater. All figures of merit of the method were satisfactory; limits of detection were particularly low for the four analytes ionized in positive mode, being in the range 8-31 ng/L. The method was applied to the determination of the six UV filters in seawater samples from Liguria, Italy. Only benzophenone-3 (BP-3) and ethylhexyl methoxycinnamate (EHMC) were measured in the analyzed samples; some of the remaining analytes were also detected but always below the limit of quantitation.  相似文献   