首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have developed a biosensor for highly sensitive and selective determination of the endocrinic disruptor bisphenol A (BPA). It is based on glassy carbon electrode modified with calf thymus DNA and a composited prepared from single walled carbon nanotubes (SWNT) and Nafion. The interaction between BPA and DNA was studied by voltammetry. The binding constant was determined to be 3.55?×?103 M?1, and the binding site has a length of 4.3 base pairs. These electrochemical studies provide further information for a better understanding of the toxicity and carcinogenicity of BPA. Under optimal conditions, the biosensor displays a linear electrochemical response to BPA in the 10 nM to 20 μM concentration range, with a detection limit as low as 5.0 nM (at an S/N of 3). The method was successfully applied to the quantification of BPA in leachates from plastic baby bottles. Recoveries range from 94.0 % to 106.0 % which underpins the excellent performance of this SWNT-based DNA sensor.
Figure
A biosensor based on DNA and single walled carbon nanotubes modified glassy carbon electrode displays a linear electrochemical response to bisphenol A in the 10 nM to 20 μM concentration range, with a detection limit as low as 5.0 nM (at an S/N of 3).  相似文献   

2.
A novel enzyme-free electrochemical sensor for H2O2 was fabricated by modifying an indium tin oxide (ITO) support with (3-aminopropyl) trimethoxysilane to yield an interface for the assembly of colloidal gold. Gold nanoparticles (AuNPs) were then immobilized on the substrate via self-assembly. Atomic force microscopy showed the presence of a monolayer of well-dispersed AuNPs with an average size of ~4 nm. The electrochemical behavior of the resultant AuNP/ITO-modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. This non-enzymatic and mediator-free electrode exhibits a linear response in the range from 3.0?×?10?5 M to 1.0?×?10?3 M (M?=?mol?·?L?1) with a correlation coefficient of 0.999. The limit of detection is as low as 10 nM (for S/N?=?3). The sensor is stable, gives well reproducible results, and is deemed to represent a promising tool for electrochemical sensing.
Figure
AuNPs/ITO modified electrode prepared by self-assembly method exhibit good electrocatalytic activity towards enzyme-free detection H2O2. The linear range of typical electrode is between 3.0?×?10?5 M and 1.0?×?10?3 M with a correlation coefficient of 0.999 and the limit detection is down to 1.0?×?10?8 M.  相似文献   

3.
We describe a molecularly imprinted polymer (MIP) for the solid-phase extraction of the skin protectant allantoin. The MIP was deposited on the surface of monodisperse silica microspheres possessing acroyl groups on the surface (MH-SiO2). The resulting MIP microspheres (MH-SiO2@MIP) showed a 3.4-fold higher adsorption capacity and a 1.9-fold better selectivity for allantoin than the respective non-imprinted polymer (MH-SiO2@NIP). The monolayer adsorption capacities of the MH-SiO2@MIP and the MH-SiO2@NIP were calculated with the help of the Langmuir model and found to be 6.8 and 1.9 mg?g?1, respectively. Adsorption kinetics fit a pseudo-second order rate mechanism, with an initial adsorption rate of 1.44 for the MH-SiO2@MIP, and of 0.07 mg?g?1?min?1 for the MH-SiO2@NIP. The material can be regenerated, and its adsorption capacity for allantoin remains stable for at least five regeneration cycles. It was successfully used as a sorbent for the selective solid-phase extraction of allantoin from Rhizoma dioscoreae.
Figure
A molecularly imprinted polymer for the selective separation of allantoin was developed. It was successfully used as a sorbent for the selective solid-phase extraction of allantoin from Rhizoma dioscoreae.  相似文献   

4.
We have prepared a hydrophilic molecularly imprinted polymer (MIP) for the hydrophobic compound bisphenol A (BPA) in aqueous solution using 3-acrylamido-N,N,N-trimethylpropan-1-aminium chloride (AMTC) as the functional monomer. Under redox-polymerization conditions, BPA forms an ion-pair with AMTC, which was confirmed by 1H-NMR titration. The imprinting effect in aqueous solution was evaluated by comparison of this material with the corresponding non-imprinted polymer (NIP) and with a control polymer (CP) bearing no AMTC. The MIP showed the highest activity among the three polymers, and the imprinting factors as calculated from the amount of BPA bound to the MIP divided by the amounts bound to NIP and CP, respectively, are 1.8 and 6.0. The MIP was selective for BPA in aqueous solution, while structurally related compounds are not recognized. Such a selectivity for a hydrophobic compound is rarely observed in aqueous medium because non-specific binding of BPA inevitably leads to hydrophobic interaction.
Figure
A hydrophilic molecularly imprinted polymer (MIP) for bisphenol A (BPA) recognition was prepared in aqueous solution. The obtained MIP (BPA-MIP) showed good selectivity under aqueous conditions  相似文献   

5.
An electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles using a potentiostatic method. The effects of pH, ratio between template molecule and monomer, number of cycles for electropolymerization, and of the solution for extraction were optimized. The current of the electro-active model system hexacyanoferrate(III) and hexacyanoferrate(IV) decreased linearly with successive addition of ThPh in the concentration range between 4.0?×?10?7?~?1.5?×?10?5 mol·L?1 and 2.4?×?10?4?~?3.4?×?10?3 mol·L?1, with a detection limit of 1.0?×?10?7 mol·L?1. The sensor has an excellent recognition capability for ThPh compared to structurally related molecules, can be regenerated and is stable.
Figure
In this paper, an electrochemical sensor for theophylline (ThPh) was prepared by electropolymerizing o-phenylenediamine (o-PD) on a glassy carbon electrode in the presence of ThPh via cyclic voltammetry, followed by deposition of gold nanoparticles to enhance the sensitivity of the sensor. Therefore, the sensor showed a high sensitivity for ThPh determining. Peak current of [Fe(CN)6]3?/[Fe(CN)6]4? varied linearly with the concentration of ThPh in the range of 4.0×10-7~1.5×10-5 mol·L-1 and 2.4×10-4~3.4×10-3 mol·L-1, and the detection limit reached 1.0×10-7 mol·L-1. Compared to structurally related molecules, the sensor also has a high recognition capability for ThPh. With excellent regeneration property and stability, the present sensor maybe provides a new class of polymer modified electrodes for sensor applications.  相似文献   

6.
In this work, an electrochemical dihydronicotinamide adenine dinucleotide (NADH) sensor based on the catalytic growth of Au nanoparticles (Au NPs) on glassy carbon electrode was developed. Catalyzed by Au NPs immobilized on pretreated glassy carbon electrode, the reduction of AuCl4 ? in the presence of hydroquinone and cetyltrimethyl ammonium chloride led to the formation of enlarged Au NPs on the electrode surface. Spectrophotometry and high-resolution scanning electronic microscope (SEM) analysis of the sensor morphologies before and after biocatalytic reaction revealed a diameter growth of the nanoparticles. The catalytic growth of Au NPs on electrode surface remarkably facilitated the electron transfer and improved the performance of the sensor. Under optimal conditions, NADH could be detected in the range from 1.25?×?10?6 to 3.08?×?10?4 M, and the detection limit was 2.5?×?10?7 M. The advantages of the proposed sensor, such as high precision and sensitivity, fast response, low cost, and good storage stability, made it suitable for on-line detection of NADH in complex biological systems and contaminant degradation processes.
Figure
Schematic presentation of the bioelectrocatalytic sensing of NADH  相似文献   

7.
Zearalenone (ZEN) is a nonsteroidal estrogenic mycotoxin produced by Fusarium graminearum on maize and barley. Because most current methods of ZEN detection rely on the use of low-stability antibodies or expensive equipment, we sought to develop a rapid, low-cost determination method using aptamers instead of antibodies as the specific recognition ligands. This work describes the isolation and identification of single-stranded DNA (ssDNA) aptamers recognizing ZEN using the modified systematic evolution of ligands by exponential enrichment methodology based on magnetic beads. After 14 rounds of repeated selection, a highly enriched ssDNA library was sequenced and 12 representative sequences were assayed for their affinity and specificity. The best aptamer, 8Z31, with a dissociation constant (K d) of 41?±?5 nM, was successfully applied in the specific detection of ZEN in binding buffer and in real samples based on a magnetic separation/preconcentration procedure. This analytical method provided a linear range from 3.14?×?10?9 to 3.14?×?10?5 M for ZEN, and the detection limit was 7.85?×?10?10 M. The selected aptamers are expected to be used in the potential development of affinity columns, biosensors, or other analytical systems for the determination of ZEN in food and agricultural products.
Figure
Determination of dissociation constant (K d) and specificity of aptamers recognizing zearalenone  相似文献   

8.
We have made a comparison of (a) different surface chemistries of SPR sensor chips (such as carboxymethylated dextran and carboxymethylated C1) and (b) of different assay formats (direct, sandwich and subtractive immunoassay) in order to improve the sensitivity of the determination of the model bacteria Acidovorax avenae subsp. citrulli (Aac). The use of the carboxymethylated sensor chip C1 resulted in a better sensitivity than that of carboxymethylated dextran CM5 in all the assay formats. The direct assay format, in turn, exhibits the best sensitivity. Thus, the combination of a carboxymethylated sensor chip C1 with the direct assay format resulted in the highest sensitivity for Aac, with a limit of detection of 1.6?×?106 CFU mL-1. This SPR immunosensor was applied to the detection of Aac in watermelon leaf extracts spiked with the bacteria, and the lower LOD is 2.2?×?107 CFU mL?1.
Figure
Possible strategies to improve the surface plasmon resonance-based immmunodetection of bacterial cells Acidovorax avenae subsp. citrulli (Aac) was used as a model pathogen. Two different sensor surfaces (carboxymethylated dextran CM5 and carboxymethylated C1) were compared. Direct detection, sandwich system and subtractive assay were investigated. The combination of a C1 chip with the direct assay format resulted in the highest sensitivity for Aac, with a limit of detection of 1.6*106 CFU mL?1  相似文献   

9.
We present an electrochemical aptasensor for rapid and ultrasensitive determination of the additive bisphenol A (BPA) and for screening drinking water for the presence of BPA. A specific aptamer against BPA and its complementary DNA probe were immobilized on the surface of a gold electrode via self-assembly and hybridization, respectively. The detection of BPA is mainly based on the competitive recognition of BPA by the immobilized aptamer on the surface of the electrode. The electrochemical aptasensor enables BPA to be detected in drinking water with a limit of detection as low as 0.284 pg?mL?1 in less than 30 min. This extraordinary sensitivity makes the method a most powerful tool for on-site monitoring of water quality and food safety.
Figure
A novel electrochemical aptasensor was developed for rapid and ultrasensitive detection of bisphenol A (BPA) and screening of BPA in drinking water using the specific aptamer against BPA.  相似文献   

10.
A sensor is described for the detection of propionaldehyde in the gas phase. The sensing scheme is based on the blue cataluminescence (CTL) emission that results from the catalytic oxidation of propionaldehyde on the surface of nanosized zirconium dioxide. The sensor displays high sensitivity to propionaldehyde, a response time of 3 s, and a recovery time of 8 s. Under optimized conditions, the intensity of CTL is linearly related to the concentration of propionaldehyde in the 2.5–1,300 mg·m?3 concentration range, with a limit of detection of 0.6 mg·m?3 (at an SNR of 3) and a relative standard deviation (for n?=?6) of 2.2 % at a level of 80 mg·m?3 of propionaldehyde. Relatively weak interference is observed for ethanol, acetone and acetaldehyde. The method was applied to analyze environmental air samples containing propionaldehyde, and data were compared with those obtained by GC-MS. The results were in good agreement, thereby indicating the utility of the sensor for routine monitoring. A possible mechanism for the catalytic oxidation of propionaldehyde on the ZrO2 surface is discussed on the basis of the chromatograms of the reaction products.
Figure
A gas sensor for propionaldehyde was fabricated based on the cataluminescence (CTL) emission generated by the catalytic oxidation of propionaldehyde on a nanosized ZrO2 surface. The sensor showed highly sensitivity and good selectivity to propionaldehyde with a response time of less than 3 s and a recovery time of under 20 s  相似文献   

11.
In the present work, a novel flow-injection chemiluminescence method based on CdTe quantum dots (QDs) was developed for the determination of nitrite. Weak chemiluminescence (CL) signals were observed from a CdTe QDs–H2O2 system under basic conditions. The addition of a trace amount of hemoglobin (Hb) caused the CL from the CdTe QDs–H2O2 system to increase substantially. In the presence of nitrite, the ferrous Hb reacted with the nitrate to form ferric Hb and NO. The NO then bound to ferrous Hb to generate iron nitrosyl Hb. As a result, the CL signal from the CdTe QDs–H2O2–Hb system was quenched. Thus, a flow-injection CL analytical system for the determination of trace nitrite was established. Under optimum conditions, there was a good linear relationship between CL intensity and the concentration of nitrite in the range 1.0?×?10?9 to 8.0?×?10?7 mol L?1 (R 2?=?0.9957). The limit of detection for nitrite using this system was 3.0?×?10?10 mol L?1 (S/N?=?3). This method was successfully applied to detect nitrite in water samples.
Figure
The scheme of the mechanism of the CL system  相似文献   

12.
A novel glucose biosensor is presented as that based on a glassy carbon electrode modified with hollow gold nanoparticles (HGNs) and glucose oxidase. The sensor exhibits a better differential pulse voltammetric response towards glucose than the one based on conventional gold nanoparticles of the same size. This is attributed to the good biological conductivity and biocompatibility of HGNs. Under the optimal conditions, the sensor displays a linear range from 2.0?×?10?6 to 4.6?×?10?5?M of glucose, with a detection limit of 1.6?×?10?6?M (S/N?=?3). Good reproducibility, stability and no interference make this biosensor applicable to the determination of glucose in samples such as sports drinks.
Figure
A novel glucose biosensor was prepared based on glucose oxidase, hollow gold nanoparticles and chitosan modified glassy carbon electrode. The electrode showed a good response for the glucose. The sensor has been verified by the determination of glucose in sport drink  相似文献   

13.
The food antioxidant quercetin was used as a template in an ultrathin molecularly imprinted polymer (MIP) film prepared by photopolymerization. Indium tin oxide (ITO) plates were electrografted with aryl layers via a diazonium salt precursor bearing two terminal hydroxyethyl groups. The latter act as hydrogen donors for the photosensitizer isopropylthioxanthone and enabled the preparation of MIP grafts through radical photopolymerization of methacrylic acid (the functional monomer) and ethylene glycol dimethacrylate (the crosslinker) in the presence of quercetin (the template) on the ITO. The template was extracted, and the remaining ITO electrode used for the amperometric determination of quercetin at a working potential of 0.26 V (vs. SCE). The analytical range is from 5.10?8 to 10?4 mol L?1, and the detection limit is 5.10?8 mol L?1.
Figure
This work describes the grafting of a molecularly imprinted polymer (MIP) film by combining diazonium surface chemistry and surface-initiated photopolymerization. The MIP grafts specifically and selectively recognize quercetin in pure solution in THF and in real green tea infusion.  相似文献   

14.
We report on a novel non-enzymatic sensor for hydrogen peroxide (HP) that is based on a biocomposite made up from chitosan (CS), hemoglobin (Hb), and silver nanoparticles (AgNPs). The AgNPs were prepared in the presence of CS and glucose in an ultrasonic bath, and CS is found to act as a stabilizing agent. They were then combined with Hb and CS to construct a carbon paste biosensor. The resulting electrode gave a well-defined redox couple for Hb, with a formal potential of about ?0.17?V (vs. SCE) at pH?6.86 and exhibited a remarkable electrocatalytic activity for the reduction of HP. The sensor was used to detect HP by flow injection analysis, and a linear response is obtained in the 0.08 to 250?μM concentration range. The detection limit is 0.05?μM (at S/N?=?3). These characteristics, along with its long-term stability make the sensor highly promising for the amperometric determination of HP.
Figure
(A) FIA it graphs of the different concentrations of H2O2 at CS/Hb/AgNP/CPE in the PBS (pH?6.86). Applied potential: ?0.4?V. (1) 0.8?×?10?6?mol?L?1, (2) 2.4?×?10?6?mol?L?1, (3) 4?×?10?6?mol?L?1 (B) Plot of catalytic peak currents vs. the concentration of H2O2.  相似文献   

15.
We have prepared core-shell magnetic molecularly imprinted polymer nanoparticles for recognition and extraction of tributyl tin (TBT). The use of particles strongly improves the imprinting effect and leads to fast adsorption kinetics and high adsorption capacities. The functional monomer acrylamide was grafted to the surface of Fe3O4 nanospheres in two steps, and MIP layers were then formed on the surface by creating a MIP layer on the surface consisting of poly(ethyleneglycol dimethacrylate) with a TBT template. The particles were characterized in terms of morphological, magnetic, adsorption, and recognition properties. We then have developed a method for the extraction of TBT from spiked mussel (Mytilidae), and its determination by liquid chromatography-tandem mass spectrometry. The method has a limit of detection of 1.0 ng?g?1 (n?=?5) of TBT, with a linear response between 5.0 and 1,000 ng?g?1. The proposed method was successfully applied to the determination of trace TBT in marine food samples with recoveries in the range of 78.3–95.6 %.
Figure
The preparation procedures of core-shell magnetic molecularly imprinted polymer nanoparticles for recognition and extraction of tributyl tin (TBT) in seafood  相似文献   

16.
A highly sensitive electrochemical sensor for determination of L-cysteine (CySH) is presented. It is based on vertically aligned multiwalled carbon nanotubes modified with Pt nanoparticles by magnetron sputtering deposition. The morphology of the nanocomposite was characterized by scanning electron microscopy, transmission electron microscopy and energy-dispersive. The electrochemistry of CySH was investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The mechanism for the electrochemical reaction of CySH at the modified electrode at different pH values is discussed. The electrode exhibits a higher electrocatalytic activity towards the oxidation of CySH than comparable other electrodes. It displays a linear dependence (R 2?=?0.9980) on the concentration of CySH in the range between 1 and 500 μM and at an applied potential of +0.45 V, a remarkably low detection limit of 0.5 μM (S/N?=?3), and an outstandingly high sensitivity of 1.42?×?103 μA?mM?1?cm?2, which is the highest value ever reported. The electrode also is highly inert towards other amino acids, creatinine and urea. The sensor was applied to the determination of CySH in urine with satisfactory recovery, thus demonstrating its potential for practical applications.
Figure
Pt nanoparticles on carbon nanotubes by sputtering deposition show high performance for L-cysteine sensing  相似文献   

17.
A sensitive amperometric sensor for norfloxacin (NF) was introduced. The receptor layer was prepared by molecularly imprinted photopolymerization of acrylamide and trimethylolpropane trimethacrylate on the surface of a gold electrode. The binding mechanism of the molecularly imprinted polymer was explored by ultraviolet (UV) and infrared (IR) spectroscopy. The chemosensor was characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance (EI), and scanning electron microscopy (SEM). The electrode prepared by photopolymerization has a better recognition ability to template molecules than that of electropolymerization and NIP. Some parameters affecting sensor response were optimized. Norfloxacin was detected by measurements of an amperometric it curve. The linear relationships between current and logarithmic concentration are obtained from 1.0?×?10?9 to 1.0?×?10?3?mol?L?1. The detection limit of the sensor was 1.0?×?10?10?mol?L?1. The proposed method is sensitive, simple, and cheap, and is applied to detect NF in human urine successfully.
Figure
Amperometric i-t curves of MIPs electrode  相似文献   

18.
We report on a carbon nanotube (CNT) fiber microelectrode coated with palladium nanoparticles (PdNPs) and enabling electrochemical sensing of hydrogen peroxide (H2O2). The synergistic effects of the CNT fibers (good mechanical strength and large surface area) and of the PdNPs (high electrocatalytic activity) result in a microelectrode for H2O2 that exhibits a 2-s response time, a detection limit as low as 2 μM, a sensitivity of 2.75 A cm?2 M?1, and a linear response range from 2 μM to 1.3 mM (R?=?0.9994). The sensor is also selective and not interfered by potentially competing species in biological fluids, thus representing an inexpensive but highly sensitive and selective microsensor for H2O2.
Figure
Images ofthe palladium nanoparticle-coated carbon nanotube (PdNP/CNT) fiber microelectrode (left) and its amperometric response to hydrogen peroxide (H2O2) with different concentrations (right)  相似文献   

19.
A glassy carbon electrode was modified with PdO-NiO composite nanofibers (PdO-NiO-NFs) and applied to the electrocatalytic reduction of hydrogen peroxide (H2O2). The PdO-NiO-NFs were synthesized by electrospinning and subsequent thermal treatment, and then characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. Factors such as the composition and fraction of nanofibers, and of the applied potential were also studied. The sensor exhibits high sensitivity for H2O2 (583.43 μA?·?mM?1?·?cm?2), a wide linear range (from 5.0 μM to 19 mM), a low detection limit (2.94 μM at an SNR of 3), good long term stability, and is resistant to fouling.
Figure
A glassy carbon electrode was modified with PdO-NiO composite nanofibers which were synthesized by electrospinning and subsequent thermal treatment. The sensor exhibited a wide linear range, high sensitivity, good stability and selectivity for the detection of hydrogen peroxide  相似文献   

20.
This work describes a comparison of three types of commercial high-performance liquid chromatography silica monolithic columns with different inner diameters and generations of monolithic sorbent: a “classic” monolithic column, the first generation (Onyx? monolithic C18, 100 mm?×?4.6 mm, Phenomenex); a “narrow” monolithic column for fast separation at lower flow rates (Chromolith® Performance RP-18e, 100 mm?×?3 mm, Merck); and a recently introduced “high-resolution” monolithic column, the next generation (Chromolith® HighResolution RP-18e, 100 mm?×?4.6 mm, Merck). Separation efficiency (number of theoretical plates, height equivalent to a theoretical plate and van Deemter curves), working pressure, the symmetry factor and resolution were critical aspects of the comparison in the case of the separation of ascorbic acid, paracetamol and caffeine. The separations were performed under isocratic conditions with a mobile phase consisting of 10:90 (v/v) acetonitrile–phosphoric acid (pH 2.80). Detailed comparison of the newest-generation monolithic column (Chromolith® HighResolution) with the previously introduced monolithic sorbents was performed and proved the advantages of the Chromolith® HighResolution column.
Figure
Chromatogram of separation using different flow rates (corresponded to optimal separation conditions); 1 0.5 mL?min-1; 2 0.6 mL?min-1; 3 0.3 mL?min-1  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏