More than 13 years of SIMS application field experience of numerous users of the ATOMIKA Ionmicroprobes have been the basis for the new SIMS Data System SDS 800. The hardware and software concept of the SDS 800, therefore, pays special attention to the following requirements:
  1. Convenient set-up, modification and re-use of the measuring parameter sets for easy, time-saving operation.
  2. Individual parameter selection from the very broad range of SIMS measuring parameters for optimum SIMS data quality.
  3. Multitasking operation for simultaneous handling of SIMS measurement, data processing, data output and of auxiliary techniques.
  4. Simultaneous depth profile/ion image acquisition and processing to enhance data quality and to validate data interpretation.
  5. User-friendly data processing and output.
  相似文献   

2.
The spatial resolution of chemical images acquired with cluster secondary ion mass spectrometry (SIMS) is limited not only by the size of the probe utilized to create the images but also by detection sensitivity. As the probe size is reduced to below 1 μm, for example, a low signal in each pixel limits lateral resolution because of counting statistics considerations. Although it can be useful to implement numerical methods to mitigate this problem, here we investigate the use of image fusion to combine information from scanning electron microscope (SEM) data with chemically resolved SIMS images. The advantage of this approach is that the higher intensity and, hence, spatial resolution of the electron images can help to improve the quality of the SIMS images without sacrificing chemical specificity. Using a pan-sharpening algorithm, the method is illustrated using synthetic data, experimental data acquired from a metallic grid sample, and experimental data acquired from a lawn of algae cells. The results show that up to an order of magnitude increase in spatial resolution is possible to achieve. A cross-correlation metric is utilized for evaluating the reliability of the procedure. Figure
?  相似文献   

3.
We describe a hybrid MALDI/C60-SIMS Q-TOF mass spectrometer and corresponding sample preparation protocols to image intact biomolecules and their fragments in mammalian spinal cord, individual invertebrate neurons, and cultured neuronal networks. A lateral spatial resolution of 10 μm was demonstrated, with further improvement feasible to 1 μm, sufficient to resolve cell outgrowth and interconnections in neuronal networks. The high mass resolution (>13,000 FWHM) and tandem mass spectrometry capability of this hybrid instrument enabled the confident identification of cellular metabolites. Sublimation of a suitable matrix, 2,5-dihydroxybenzoic acid, significantly enhanced the ion signal intensity for intact glycerophospholipid ions from mammalian nervous tissue, facilitating the acquisition of high-quality ion images for low-abundance biomolecules. These results illustrate that the combination of C60-SIMS and MALDI mass spectrometry offers particular benefits for studies that require the imaging of intact biomolecules with high spatial and mass resolution, such as investigations of single cells, subcellular organelles, and communities of cells. Graphical Abstract
?  相似文献   

4.
A glassy carbon electrode was modified with gold nanoparticles (Au-NPs) on a quaternized cellulose support in a film composed of poly(ethylene glycol diglycidyl ether) (PEGDGE), and Hb was immobilized on the Au-NPs. The sensor film was characterized by UV–vis spectra, scanning electron microscopy, and electrochemical impedance spectroscopy. Cyclic voltammetry of the Hb in the Au@Qc/PEGDGE film revealed a pair of well-defined and quasi reversible peaks for the protein heme Fe(III)/Fe(II) redox couple at about ?0.333 V (vs. SCE). The sensor film also exhibited good electrocatalytic activity for the reduction of nitric oxide and hydrogen peroxide. The amperometric response of the biosensor depends linearly on the concentration of nitric oxide in the 0.9 to 160 μM range, and the detection limit is as low as 12 nM (at 3σ). The response to hydrogen peroxide is linear in the 59 nM to 4.6 μM concentration range, and the detection limit is 16 nM (at 3σ). This biosensor is sensitive, reproducible, and long-term stable. Figure
An electrochemical biosensor based on the immobilization of hemoglobin in Au@Qc NPs /Poly ethylene glycol diglycidyl ether composite film is developed.  相似文献   

5.
Poly(2-vinylpyridine)s (P2VPs) are important polymers with extensive applications in modern day material science. P2VP is an exceptional case for liquid chromatography because of certain polar interactions with most of the stationary phases. In the present study, we established the critical adsorption point (CAP) of P2VP for the first time. The effectiveness of the method is demonstrated by analyses of blends and block copolymers of P2VP and PMMA. The CAP of PMMA is established for determination of molar mass of P2VP component of above mentioned blends and block copolymers. The methods successfully demonstrate the separation of both types of homopolymers from the rest of the samples in conjunction with the determination of molar mass distribution of noncritical block or component. Graphical Abstract
?  相似文献   

6.
This paper describes the synthesis, characterisation and application of a very sensitive electrochemical sensor based on a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNTs) decorated with homogeneously distributed spherical gold nanoparticles (AuNPs). These AuNPs presented diameters ranging from 2 to 10 nm. The AuNPs were prepared directly on the MWCNTs’ surface via a synthesis using HAuCl4 and citric acid as the reducing agent. The resulting material (Au/MWCNTs) was characterised by scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD) and Raman spectroscopy. The developed Au/MWCNTs sensor was used in the determination of nitric oxide (NO) in phosphate buffer solution at pH 4.4 by differential pulse voltammetry. In the potential window between 0.5 and 0.65 V, a well-defined oxidation peak was observed, whose height was proportional to the NO concentration in the solution. The Au/MWCNTs-modified electrode exhibited high sensitivity for the determination of nitric oxide, with the limit of detection being 0.21 nmol L?1 (S/N?=?3). No significant interference was detected for nitrite and CO2 in the NO detection. Our study demonstrated that the resultant Au/MWCNT-modified electrode can be used for nitric oxide detection in the presence of ascorbic acid, dopamine and uric acid, being potentially useful for determinations of NO in real samples. Figure
?  相似文献   

7.
Lipophilic marine toxins are produced by harmful microalgae and can accumulate in edible filter feeders such as shellfish, leading to an introduction of toxins into the human food chain, causing different poisoning effects. During the last years, analytical methods, based on liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), have been consolidated by interlaboratory validations. However, the main drawback of LC-MS/MS methods remains the limited number of compounds that can be analyzed in a single run. Due to the targeted nature of these methods, only known toxins, previously considered during method optimization, will be detected. Therefore in this study, a method based on ultra-high-performance liquid chromatography coupled to high-resolution Orbitrap mass spectrometry (UHPLC-HR-Orbitrap MS) was developed. Its quantitative performance was evaluated for confirmatory analysis of regulated lipophilic marine toxins in shellfish flesh according to Commission Decision 2002/657/EC. Okadaic acid (OA), dinophysistoxin-1 (DTX-1), pectenotoxin-2 (PTX-2), azaspiracid-1 (AZA-1), yessotoxin (YTX), and 13-desmethyl spirolide C (SPX-1) were quantified using matrix-matched calibration curves (MMS). For all compounds, the reproducibility ranged from 2.9 to 4.9 %, repeatability from 2.9 to 4.9 %, and recoveries from 82.9 to 113 % at the three different spiked levels. In addition, confirmatory identification of the compounds was effectively performed by the presence of a second diagnostic ion (13C). In conclusion, UHPLC-HR-Orbitrap MS permitted more accurate and faster detection of the target toxins than previously described LC-MS/MS methods. Furthermore, HRMS allows to retrospectively screen for many analogues and metabolites using its full-scan capabilities but also untargeted screening through the use of metabolomics software. Figure
?  相似文献   

8.
We report herein the development of a highly sensitive colorimetric method for detection of d-Penicillamine using citrate-capped gold nanoparticles (AuNPs). This assay relies upon the distance-dependent of gold nanoparticles surface plasmon resonance band of gold nanoparticles. By replacing the thiol-containing chelator drug, d-Penicillamine, with citrate on the gold nanoparticles surface, a new peak appearing at a longer wavelength intensifies and shifts further to the red from the original peak position due to aggregation of gold nanoparticles which depends on ionic strength, gold nanoparticles and d-Penicillamine concentration. During this process, the plasmon band at 521 nm decreases gradually along with the formation of a new red-shifted band at 630 nm. The calibration curve which is derived from the ratio intensities of absorbance at longer wavelength (630 nm) to original wavelength (521 nm) displays a linear relation in the range of 5.0 × 10?6–3.0 × 10?4 M d-Penicillamine. Lower limit of detection for d-Penicillamine, at the signal-to-noise ratio of 3 (3σ), was 3.8 × 10?6 M. The developed methodology was successfully applied for the determination of d-Penicillamine in human urine and plasma.  相似文献   

9.
High-performance liquid chromatography with chemiluminescence detection based on the reaction with acidic potassium permanganate and formaldehyde was explored for the determination of neurotransmitters and their metabolites. The neurotransmitters norepinephrine and dopamine were quantified in the left and right hemispheres of rat hippocampus, nucleus accumbens and prefrontal cortex, and the metabolites vanillylmandelic acid, 3,4-dihydrophenylacetic acid, 5-hydroxyindole-3-acetic acid and homovanillic acid were identified in human urine. Under optimised chemiluminescence reagent conditions, the limits of detection for these analytes ranged from 2.5?×?10?8 to 2.5?×?10?7 M. For the determination of neurotransmitter metabolites in urine, a two-dimensional high-performance liquid chromatography (2D-HPLC) separation operated in heart-cutting mode was developed to overcome the peak capacity limitations of the one-dimensional separation. This approach provided the greater separation power of 2D-HPLC with analysis times comparable to conventional one-dimensional separations. Figure
2D-HPLC separation and permanganate chemiluminescence detection of neurotransmitter metabolites  相似文献   

10.
Point Mutations on the Kirsten rat sarcoma viral oncogene homolog (KRAS) have been identified as an important predictive biomarker for response to cancer therapy targeting the epidermal growth factor receptor. KRAS mutations are prevalent in up to 40 % of all colorectal carcinomas, and routinely conducted KRAS genotyping is becoming mandatory to predict therapy success and to reduce therapy costs. We report a low-cost, disposable and ready-to-use centrifugal microfluidic cartridge (termed GeneSlice) containing preloaded primers and probes. The GeneSlice cartridge enables the parallel detection of the seven most relevant KRAS point mutations by allele-specific real-time PCR. It represents a cost effective alternative to dideoxy-sequencing with a faster time-to-result (~ 2 h versus up to 20 h in case of dd-sequencing). Microfluidic processing of the GeneSlice along with allele-specific amplification and real-time detection are conducted in a slightly modified, commercially available PCR thermocycler. Intra-chip standard deviation of Cq values on the GeneSlices is negligible (GeneSlice 1: Cq,std.dev. = 0.13; GeneSlice 2: Cq,std.dev?=?0.26). In 23 of 24 experiments, the data for genotyping 6 cancer cell lines (n?=?4 per cell line) agreed with dd-sequencing. Additionally, DNA derived from microdissected formalin-fixed and paraffin embedded colorectal carcinomas of two cases was genotyped correctly and reproducibly (n?=?3 per patient; one GeneSlice excluded from evaluation). The GeneSlice therefore clearly demonstrated the potential to become a valuable tool for routine diagnostics of KRAS mutations by reducing costs and hands-on time. Figure
Photograph of a centrifugal microfluidic cartridge “GeneSlice” for multiplex genotyping of KRAS point mutations from tumor cell DNA by allele-specific real-time PCR. Information about the mutation status is required to predict success of state-of-the-art cancer therapy with antibodies  相似文献   

11.
The concentrations of ten trace and dopant elements in GaAs semiconductor were determined by reactor neutron activation analysis after removal of As by evaporation of AsCl3. The retentions of the elements of interest were measured using radiotracers. The concentrations of doping elements (Te, Cr and Zn) in commercial GaAs samples were compared to the limit of detection of these elements to analyze the possibility to use NAA for concentration depth profiling measurements. The NAA results were compared with those of electrical measurements and SIMS and the discrepancies found are discussed.  相似文献   

12.
13.
In this work, a new approach is proposed to verify the differentiating characteristics of five bacteria (Escherichia coli, Enterococcus faecalis, Streptococcus salivarius, Streptococcus oralis, and Staphylococcus aureus) by using digital images obtained with a simple webcam and variable selection by the Successive Projections Algorithm associated with Linear Discriminant Analysis (SPA-LDA). In this sense, color histograms in the red–green–blue (RGB), hue-saturation-value (HSV), and grayscale channels and their combinations were used as input data, and statistically evaluated by using different multivariate classifiers (Soft Independent Modeling by Class Analogy (SIMCA), Principal Component Analysis-Linear Discriminant Analysis (PCA-LDA), Partial Least Squares Discriminant Analysis (PLS-DA) and Successive Projections Algorithm-Linear Discriminant Analysis (SPA-LDA)). The bacteria strains were cultivated in a nutritive blood agar base layer for 24 h by following the Brazilian Pharmacopoeia, maintaining the status of cell growth and the nature of nutrient solutions under the same conditions. The best result in classification was obtained by using RGB and SPA-LDA, which reached 94 and 100 % of classification accuracy in the training and test sets, respectively. This result is extremely positive from the viewpoint of routine clinical analyses, because it avoids bacterial identification based on phenotypic identification of the causative organism using Gram staining, culture, and biochemical proofs. Therefore, the proposed method presents inherent advantages, promoting a simpler, faster, and low-cost alternative for bacterial identification. Figure
Summary of the new proposed methodology for bacteria classification by using color histograms and SPA-LDA  相似文献   

14.
The diagnosis of cardiomyopathies by endomyocardial biopsy analysis is the gold standard for confirmation of causative reasons but is failing if a sample does not contain the area of interest due to focal pathology. Biopsies are revealing an extract of the current situation of the heart muscle only, and the need for global organ-specific or systemic markers is obvious in order to minimize sampling errors. Global markers like specific gene expression signatures in myocardial tissue may therefore reflect the focal situation or condition of the whole myocardium. Besides gene expression profiles, microRNAs (miRNAs) represent a new group of stable biomarkers that are detectable both in tissue and body fluids. Such miRNAs may serve as cardiological biomarkers to characterize inflammatory processes, to confirm viral infections, and to differentiate various forms of infection. The predictive power of single miRNAs for diagnosis of complex diseases may be further increased if several distinctly deregulated candidates are combined to form a specific miRNA signature. Diagnostic systems that generate disease-related miRNA profiles are based on microarrays, bead-based oligo sorbent assays, or on assays based on real-time polymerase chain reactions and placed on microfluidic cards or nanowell plates. Multiparametric diagnostic systems that can measure differentially expressed miRNAs may become the diagnostic tool of the future due to their predictive value with respect to clinical course, therapeutic decisions, and therapy monitoring. We discuss here specific merits, limitations and the potential of currently available analytical platforms for diagnostics of heart muscle diseases based on miRNA profiling. Contains 34 references. Figure
Modern diagnostics of cardiomyopathies will include multiparametric analysis of microRNA profiles in endomyocardial biopsies by real-time PCR or bead-based OLISA techniques. In contrast to high-throughput screening technologies diagnostic systems are realized by down-scaling sample volumes and simultaneous measurement of a limited number of stable disease related parameters.  相似文献   

15.
Stereocomplex-poly(l- and d-lactide) (sc-PLA) and poly(methyl methacrylate) (PMMA) blends were prepared by solution blending at PMMA loadings from 20 to 80 mass%. The miscibility and crystallization behaviors of the blends have been studied in detail by differential scanning calorimeter. The single-glass transition temperatures (T g) of the blends demonstrated that the obtained system was miscible in the amorphous state. It was observed that the crystallization peak temperature of sc-PLA/PMMA blends was marginally lower than that of neat sc-PLA at various cooling rates, indicating the dilution effect of PMMA on the sc-PLA component to restrain the overall crystallization process. In the study of isothermal crystallization kinetics, the reciprocal value of crystallization peak time ( \( t_{\text{p}}^{ - 1} \) ) decreased with increasing PMMA content, indicating that the addition of non-crystalline PMMA inhibited the isothermal crystallization of sc-PLA at an identical crystallization temperature (T c). Moreover, the negative value of Flory–Huggins interaction parameter (χ 12 = ?0.16) of the blend further indicated that sc-PLA and PMMA formed miscible blends.  相似文献   

16.
17.
An electrochemical glucose biosensor was developed by immobilizing glucose oxidase (GOx) on a glass carbon electrode that was modified with molybdenum disulfide (MoS2) nanosheets that were decorated with gold nanoparticles (AuNPs). The electrochemical performance of the modified electrode was investigated by cyclic voltammetry, and it is found that use of the AuNPs-decorated MoS2 nanocomposite accelerates the electron transfer from electrode to the immobilized enzyme. This enables the direct electrochemistry of GOx without any electron mediator. The synergistic effect the MoS2 nanosheets and the AuNPs result in excellent electrocatalytic activity. Glucose can be detected in the concentration range from 10 to 300 μM, and down to levels as low as 2.8 μM. The biosensor also displays good reproducibility and long-term stability, suggesting that it represents a promising tool for biological assays. Figure
A MoS2-based glucose sensor has been prepared by gold nanoparticles-decorated MoS2 nanocomposite, which exhibited excellent electrocatalytic activity, reproducibility and long-term stability. It was applied to determine glucose concentration in human serum, suggest the sensor maybe promising for practical application.  相似文献   

18.
Morphine was used as a model analyte to examine the possibility of using cellulose, physically modified by papermaking and converting techniques, as a capillary matrix in a lateral flow type of diagnostic assay. This research was directed toward low-cost, disposable, and portable paper-based diagnostics, with the aim of addressing the analytical performance of paper as a substrate in the analysis for drugs of abuse. Antibody Fab fragments were used as sensing molecules, and gold nanoparticle detection was employed. Inkjet printing was used to pattern sensing biomolecules as detection zones on paper. To validate the usefulness of paper as a diagnostic platform, the principle of a direct sandwich assay, based on immunocomplex formation between morphine and the anti-morphine Fab fragment and detection of the formed immunocomplex by another Fab fragment, was implemented. Results were compared with that achieved by using nitrocellulose as a reference material. Possible interfering from the sample matrix on assay quality was investigated with spiked oral fluid samples. Under optimized conditions, a visually assessed limit of detection for the sandwich assay was 1 ng/mL, indicating that the paper-based test devices developed in this work can perform screening for drugs of abuse and can fulfill the requirement for a sensitive assay in diagnostically relevant ranges. Fig
?  相似文献   

19.
Carbon/1-octadecanethiol-carboxylated multiwalled carbon nanotubes (cMWCNT) composite was used to construct a DNA sensor for detection of human bacterial meningitis caused by Neisseria meningitidis. The carbon composite electrode was used to covalently immobilize 5′-amine-labeled 19-mer single-stranded DNA (ssDNA) probe, which was hybridized with 1.35?×?102–3.44?×?104 pM (0.5–128 ng/5 μl) of single-stranded genomic DNA (ssG-DNA) of N. meningitidis for 10 min at room temperature (RT). The surface topography of the DNA sensor was characterized by using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) while electrochemically characterized by electrochemical impedance. The immobilization of ssDNA probe and hybridization with ssG-DNA were detected electrochemically by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at RT in 30 min with a response time of 1 min. The DNA sensor showed high pathogenic specificity and can distinguish among complement, noncomplement, one base mismatch, and triple base mismatch oligomer targets. The limit of detection (LOD) and sensitivity of the sensor were approximately 68 pM and 38.095 (μA/cm2)/nM of ssG-DNA, respectively, using DPV. The improved sensitivity and LOD of the sensor can be attributed to the higher efficiency of probe immobilization due to high surface area-to-volume ratio and good electrical activity of cMWCNT. Figure
?  相似文献   

20.
This study evaluates solid-phase micro-extraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) to determine trace levels of bis-phenol A in water and leached from plastic containers. In our study, we used very thin composite membranes prepared in the laboratory. The extraction using headspace post-derivatization with bis(trimethylsilyl) trifluoroacetamide (BSTFA), containing 1 % trimethylchlorosilane (TMCS) vapor, following SPME was compared with extraction without derivatization. The SPME experimental procedures to extract bis-phenol A in water were optimized with a relatively polar polyacrylate (PA)-coated fiber, an extraction time of 50 min, and desorption at 300 °C for 2 min. Headspace derivatization following SPME was performed using 7 μL of BSTFA with 1 % TMCS at 65 °C for 30 s. The precision was 5.2 % without derivatization and 9.0 % headspace derivatization. The detection limit was determined to be at the nanogram per liter level. When SPME was used following headspace derivatization, the detection limit was one order of magnitude better than that achieved without derivatization. The results of this study reveal the adequacy of the SPME–GC–MS method for analyzing bisphenol A leached from plastic containers. The concentrations of bisphenol A leached from plastic containers into water ranged from 0.7 to 78.5 μg L?1.  相似文献   