首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary Certification of the content of endogenous organochlorine pesticides and their metabolites (OCPs) in pork fat is described and the certified values are presented. The OCPs include hexachlorobenzene (HCB), -, - and -HCH, -heptachlor epoxide (-hepo), dieldrin, endrin, p,p'-DDT, p,p'-TDE and p,p'-DDE. In a previous paper [1] the preparation of pork fat as a candidate reference material has been described as well as the investigation of its homogeneity and stability. This material, when certified, may serve for the verification of the results of determinations of the above organochlorine pesticides. This paper deals with the certification of these OCPs in pork fat.Part I see [1]  相似文献   

2.
Nitroimidazoles have been applied in the past to poultry and pigs to treat protozoan diseases and to combat bacterial infections, but due to adverse health effects their use in food-producing animals has meanwhile been banned in the EU. The request for a certified reference material in a representative matrix was stipulated by the responsible Community Reference Laboratory and is underpinned by the need to improve the accuracy and comparability of measurement data and to establish metrological traceability of analytical results. The Institute for Reference Materials and Measurements (IRMM) has responded to this demand by developing and producing a new certified matrix reference material, ERM-BB124. This incurred lyophilised pork meat material was certified according to ISO guides 34 and 35 for the mass fractions of six nitroimidazole compounds. Processing of the frozen muscle tissue to the final material was accomplished by application of cutting, freeze-drying, mixing and milling techniques. Homogeneity and stability measurements were performed using liquid chromatography tandem mass spectrometry. The relative standard uncertainty due to possible heterogeneity showed to be below 1.8% for all analytes. Potential degradation during transport and storage was assessed by isochronous stability studies. No significant instability was detected at a storage temperature of −20 °C for a shelf-life of 2 years. The certified mass fraction values were assigned upon evaluation of the data acquired in an international laboratory inter-comparison involving 12 expert laboratories using different sample preparation procedures, but exclusively LC-MS/MS methods. Relative standard uncertainty contributions for the characterisation (between-lab variation of mean values) were found to be between 1.6 and 4.8%. Certified values for five analytes were in the range of 0.7 to 6.2 μg kg−1, with expanded relative uncertainties ranging between 7 and 14%. Dimetridazole could be certified as “<0.25 μg kg−1 with a probability of 95%”. All values are traceable to the International System of Units (SI). The material is intended to be used for method validation purposes (including trueness estimation) and for method performance assessment.  相似文献   

3.
A beef fat sample was prepared and tested as candidate reference material for the pesticides chlorfluazuron (CFZ) and fluazuron (FZN). An analytical method employing HPLC with UV absorbance detection was developed for homogeneity and stability testing. The material consisted of beef fat spiked with acetone solutions of CFZ and FZN to achieve concentrations close to 1.0 mg/kg for each compound. The coefficients of variation of 7 analyses carried out to test between-jar homogeneity were 1.8% and 2.3% for FZN and CFZ, respectively. No instability of CFZ was detected over a three month period. The candidate reference material was found to be suitable for certification by interlaboratory testing.  相似文献   

4.
The certification by interlaboratory testing of a candidate reference material (ACSL CRM 3) for the concentration (mass fraction) of the pesticides chlorfluazuron (CFZ) and fluazuron (FZN) is described. The certification process was based on a two-stage nested design described in ISO Guide 35. Analysis of results reported by collaborating laboratories provided an assessment of the homogeneity of the RM. The certified values were chlorfluazuron -1.01 mg/kg and fluazuron -1.02 mg/kg. The upper and lower 95% confidence limits for CFZ and FZN were calculated to be: CFZ upper=1.05 mg/kg, lower=0.97 mg/kg; FZN upper=1.08 mg/kg, lower=0.95 mg/kg. A certificate was prepared according to guidelines set out in ISO Guide 31.  相似文献   

5.
Phenolic phytochemical are known to perform several functions ranging from phytoprotectants, to protecting lipids in food products, to antioxidant activity in animals and humans. The need for a common standard mixture containing multiple phenolic phytochemicals is critical for the development of a robust validation assay for accurately quantifying antioxidant activity in various matrixes. Different research groups have used A wide array of single purified reference phenolic compounds in this regard. A 5 compound mixture (caffeic acid, morin hydrate, hesperetin, catechin hydrate, and epigallocatechin gallate) containing phenolic compounds from 4 subgroups (phenolic acid, flavone, flavanone, and flavan-3-ol) was prepared. The mixture was assayed for stability evaluation by high-performance liquid chromatography (HPLC) using a diode array detection procedure for a 3 month time interval. HPLC analysis confirmed that there was no significant interaction between different components of the mixture. The among-sample relative standard deviation (RSD) of all 5 phenolic compounds, as well as the total HPLC area, was < 1%. The RSD due to instrument variation was < 2% and the total RSD among-days was < 5%. These results unambiguously suggest that the sample was stable for a 3 month time interval in an amber vial stored in a refrigerator below 5 degrees C. This mixture is currently being used for the single-laboratory validation study for the assay of total phenolic content by the Folin-Ciocalteu method and the antioxidant capacity by oxygen radical absorbing capacity procedure.  相似文献   

6.
7.
Celiac disease and wheat allergy are the most common adverse reactions triggered by cereal proteins, mainly gluten, which is one of the 14 allergenic food ingredients that must be labeled on food products in the European Union (EU). To meet the requirements of this regulation, reliable analytical methodology for proper quantification of gluten is necessary. However, validation of presently used methods (ELISA and lateral flow device) is limited partly due to the lack of reference methods and incurred reference materials. To solve this problem, the goal of our work was to develop an incurred reference material for the quantification of gluten under the auspices of EU-FP6 funded Network of Excellence MoniQA. During this work, we produced a processed model product (cookie) containing gliadin (major allergenic fraction of gluten) in a defined amount. This paper addresses the development process of this material together with the associated problems (insufficient homogeneity and low recovery) and their solutions. As a result, an incurred food matrix was produced on a laboratory-scale with a potential use as a reference material. The model product was tested by an ELISA method followed by a comparative study of commercially available ELISA kits to investigate the applicability of the product. Preliminary results of this study are also presented.  相似文献   

8.
Accreditation and Quality Assurance - Food Safety and Standards Authority of India has set maximum permissible level of lead in noodle at 2.5 mg/kg. The standardized lead measurement is of high...  相似文献   

9.
We present the development process for National Institute of Metrology (NIM) bovine serum albumin (BSA) certified reference material (CRM). Each CRM unit contains about 200 mg of purified BSA. The moisture, ignition residue, molecular weight, and high-performance liquid chromatography (HPLC) purity were analyzed and mass spectrometry based protein identification was carried out to ensure the material was BSA. Both amino acid based isotope dilution mass spectrometry (IDMS) and a purity deduction method were selected for value assignment. The certified value was the average of the IDMS and the purity deduction result. HPLC purity analysis was used to examine the homogeneity and stability of solid BSA CRM. Fifteen units were selected for between-bottle homogeneity examination and seven subsamples from the same bottle were selected for within-bottle homogeneity examination. Statistics showed the CRM passed both the between-bottle and the within-bottle homogeneity examination. The CRM stability under storage conditions (-20 °C) was tested for 18 months and no trend was observed. Uncertainties from the balance, amino acid purity, hydrolysis, method reproducibility, homogeneity, and stability were taken into account in uncertainty evaluation. The final certified value of NIM BSA CRM is (0.963±0.038) g/g.  相似文献   

10.
A certified reference material (CRM) for the determination of perfluorooctanoic acid (PFOA) has been issued as NMIJ CRM 4056-a by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Purity (kg kg?1) based on a titration method was determined by subtracting the mass fractions of impurities measured using liquid chromatography/mass spectrometry (LC/MS) from those of acids expressed as PFOA measured by a neutralization potentiometric titration. To validate an obtained result, purity based on a mass balance method was determined by subtracting the mass fractions of impurities, measured using LC/MS, Karl-Fischer titration (KFT), and vacuum evaporation, from 1 kg kg?1. Results from both titration and mass balance methods were in agreement within the accepted limits of uncertainty. The certified purity of NMIJ CRM 4056-a was determined to be 0.959 kg kg?1, calculated as the mean of the results obtained with the two methods. The standard uncertainty of the certified purity was evaluated from purity evaluations as well as from sample homogeneity and stability obtained from LC/MS and KFT analyses. Consequently, the expanded uncertainty was estimated to be 0.005 kg kg?1 with a coverage factor of k = 2.  相似文献   

11.
The paper describes a methodology for a reference material preparation to be used for the determination of the production date (i.e. the time elapsed since the last chemical processing) of uranium materials based on the 230Th/234U radiochronometer. The reference material was prepared from highly enriched uranium by a complete separation of thorium decay products, thus zeroing the initial daughter nuclide concentration at known time. The complete elimination of thorium from the starting material was verified by gamma spectrometric measurements and by addition of a 232Th tracer to the material and its re-measurement in the final product after the separation. The validation of the methodology was carried out subsequently by comparing the ingrown daughter nuclide 230Th and the measured 230Th/234U ratio after recorded times following the last chemical separation with the calculated values obtained on the basis of their respective half-lives. The prepared reference material can be used as a quality control material for age determination of uranium in nuclear forensics and safeguards as well as for method validation.  相似文献   

12.
13.
氮中二氧化氮气体标准物质的研制   总被引:2,自引:0,他引:2  
采用称量法制备并计算定值,研制(10~5000)μmol.mol-1氮中二氧化氮气体标准物质。考察了气体标准物质随贮存时间和钢瓶压力变化的稳定性,将制备的气体标准物质与GBW 08180进行比对验证,结果表明研制的气体标准物质定值的扩展不确定度优于3%(k=3),有效期限为12个月。  相似文献   

14.
Deoxynivalenol (DON), nivalenol (NIV) and zearalenone (ZEN) are toxic secondary metabolites produced by several species of Fusarium fungi. These mycotoxins are often found together in a large variety of cereal-based foods, which are regulated by maximum content levels of DON and ZEN. To date, suitable certified reference materials (CRM) intended for quality control purposes are lacking for these Fusarium mycotoxins. In order to overcome this lack, the first CRM for the determination of DON, NIV and ZEN in naturally contaminated wheat flour (ERM®-BC600) was developed in the framework of a European Reference Materials (ERM®) project. This article describes and discusses the whole process of ERM®-BC600 development, including material preparation, homogeneity and stability studies, and an interlaboratory comparison study for certification. A total of 21 selected expert laboratories from different European countries with documented expertise in the field of mycotoxin analysis took part in the certification study using various gas and liquid chromatographic methods. The certified values and their corresponding expanded uncertainties (k?=?2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows: 102?±?11 μg?kg?1 for DON, 1000?±?130 μg?kg?1 for NIV and 90?±?8 μg?kg?1 for ZEN.  相似文献   

15.
16.
17.
Summary Carbon has been determined in the certified reference sample Euro CRM Pure Iron 097-1 to 3.98 g C/g (R = 0.15 at P = 95%) by combustion of the sample portion with subsequent indication of the CO2 by coulometry. A calibration material based on primary sources of carbon was used with a sufficient small interval of uncertainty of the accuracy and an adequate weighing system. The blank could be kept sufficiently small with a fraction of 23% of the total analytical signal. The surface carbon of the 097-1 was determined to approximately 50% of the total carbon. This result of total carbon is considerably lower than the values in the certificate reading up to 20 g/g. This reflects the strong tendency to too high values in the certificates of reference steels with contents of carbon up to 100 g/g. Examples are given.
Herstellung von Referenzmaterial — Bestimmung von Kohle in Stählen und reinem Eisen im Bereich von 1–100 g/g mit primärer Kalibrierung
  相似文献   

18.
A certified reference material (CRM), KRISS CRM 108-10-003, has been developed for analysis of acrylamide in potato chips, as a representative of carbohydrate-rich food cooked in high-temperature oil. The material was prepared by grinding commercially available potato chips to a paste which was then homogenized, bottled in 15-g units, and stored at ?70 °C. Certification, homogeneity and stability testing, were carried out by liquid chromatography–isotope-dilution mass spectrometry (ID-LC–MS). A single ID-LC–MS measurement was performed for each of 10 selected units for certification and homogeneity assessment. The mean measurement result for the 10 bottles, 0.455?±?0.012 mg?kg?1, was assigned as the certified value of the CRM. The between-bottle homogeneity was 0.8% of the certified value. The within-bottle homogeneity, tested by measuring three replicate sub-samples from each of three randomly selected bottles, was similar to the between-bottle homogeneity. The stability of the CRM under storage conditions (?70 °C) was tested for 21 months and no change in the acrylamide content was observed within the measurement uncertainty. Stability of the CRM at –20 °C (storage at user’s site) and room temperature (for regular use and transportation) was also tested. Also presented is the newly designed procedure for evaluating the uncertainty of the certified value for the characterization scheme used in this study.
Figure
  相似文献   

19.
20.
The standard methodology used for the detection of bacteria in environmental samples and food is primarily based on bacterial growth on specific culture media and confirmation by biochemical and/or immunological tests of all presumptive colonies. However, this methodology presents a number of drawbacks, such as low sensitivity and specificity, and the long time needed to obtain results. For this reason, the implementation of molecular methods in diagnostic laboratories has increased over the past several years. Nevertheless, most of these newer methods have not been included in current legislation, and, in most of cases, they have not yet been normalized. In this sense, the availability of appropriate reference materials (RMs) can help to overcome these deficiencies. The aim of this study was to develop and validate, following ISO Guide 34, a new RM, in a tablet format, for the quantification of Legionella pneumophila and Salmonella spp. by quantitative PCR (qPCR). This new RM can be used as a work reference sample in internal quality control, in the organization of proficiency testing schemes (PTS), as well as for the validation of molecular methods based on qPCR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号