首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The use of polystyrene-based anion exchangers with aqueous eluents for the separation of primary aromatic amines has been investigated, and extended with satisfactory results to microcrystalline cellulose, cellulose-based anion-exchangers and sodium CM-cellulose layers.Interesting separations of the amines have also been effected electrophoretically on AG 1-X4 layers.The use of water-organic solvent mixtures on polystyrene-based cation exchangers is discussed.  相似文献   

2.
Two optically active liquid anion-exchangers have been synthesized. The separation factors of the enantiomers of sodium (+/-)-mandelate and sodium-N-acetyl-(+/-)-alanate have been determined by batchwise equilibration of aqueous solutions of the salts with chloroform solutions of each of the exchangers. Sodium mandelate has been resolved by Craig countercurrent extraction with one of these exchangers. Optically pure products can be obtained even though the liquid ion-exchanger is not optically pure.  相似文献   

3.
Brajter K  Słonawska K 《Talanta》1983,30(7):471-474
The use of glycine as complexing agent for chromatographie separation of palladium from platinum, or palladium from iridium, on cellulose anion-exchangers has been investigated and found possible over a wide range of concentration ratios. The method can be used for analysis of Pd-Ir alloys. The nature of the complexes taking part in the ion-exchange has been identified.  相似文献   

4.
Slavek J  Waller P  Pickering WF 《Talanta》1990,37(4):397-406
The labile metal content of sediments can be evaluated by equilibrating sediment suspensions with ion-exchange resins. By use of a sequence of strong-acid and weak-acid cation-exchangers (H(+)- and Na(+)-form) and chelating resins, extraction can be performed at pH values ranging from 2 to 10. The results allow the total metal content to be subdivided into seven categories designated as (i) low-pH labile, (ii) weak-acid labile, (iii) exchangeable and readily desorbed at sediment-suspension pH, (iv) weak-base labile, (v) high-pH labile, (vi) non-labile soluble forms and (vii) detrital metal content. The sediment suspensions are mixed overnight with the different types of exchanger (held in porous containers) and the cations transferred from the sediment are subsequently back-extracted from the resins into 0.05M EDTA (pH 7.5). The EDTA extracts are analysed for Cu, Pb, Zn, Cd, Ca, Mg, Fe and Al. Analysis of the aqueous phase left in contact with the sediment residue gives the amount of non-labile species released. Eighteen sediments, containing various levels of metal contamination, and an effluent dam sludge have been examined by this technique. All the exchangers released Ca and Mg from the sediments, and the H(+)-form exchangers also released Fe and Al. Some of the Fe, Al and to a lesser extent Zn released by the sediment/exchanger interactions was present as non-labile "soluble" species. The advantages and limitations of this "labile metal" fractionation scheme have been considered.  相似文献   

5.
Several prototypes of multi-modal ligands suitable for the capture of negatively charged proteins from high conductivity (28 mS/cm) mobile phases were coupled to Sepharose 6 Fast Flow. These new prototypes of multi-modal anion-exchangers were found by screening a diverse library of multi-modal ligands and selecting anion-exchangers resulting in elution of test proteins at high ionic strength. Candidates were then tested with respect to breakthrough capacity of BSA in a buffer adjusted to a high conductivity (20 mM Piperazine and 0.25 M NaCl, pH 6.0). The recovery of BSA was also tested with a salt step (from 0.25 to 2.0 M NaCl using 20 mM Piperazine as buffer, pH 6.0) or with a pH-step to pH 4.0. We have found that non-aromatic multi-modal anion-exchange ligands based on primary or secondary amines (or both) are optimal for the capture of proteins at high salt conditions. Furthermore, these new multi-modal anion-exchange ligands have been designed to take advantage not only of electrostatic but also hydrogen bond interactions. This has been accomplished through modification of the ligands by the introduction of hydroxyl groups in the proximity of the ionic group. Experimental evidence on the importance of the relative position of the hydroxyl groups on the ligand in order to improve the breakthrough capacity of BSA has been found. Compared to strong anion-exchangers such as Q Sepharose Fast Flow the new multi-modal weak anion-exchangers have breakthrough capacities of BSA at mobile phases of 28 mS/cm and pH 6.0 that are 20-30 times higher. The new multi-modal anion-exchangers can also be used at normal anion-exchange conditions and with either a salt step or a pH-step to acidic pH can accomplish the elution of proteins. In addition, the functional performance of the new anion-exchangers was found to be intact after treatment in 1.0 M sodium hydroxide solution for 1 week. A number of multi-modal anion-exchange ligands based on aromatic amines exhibiting high breakthrough capacity of BSA have been found. With these ligands recovery was often found to be low due to strong non-electrostatic interactions. However, for phenol derived anion-exchange media the recovery can be improved by desorption at high pH.  相似文献   

6.
A sensitive and selective high-performance liquid chromatographic method has been developed for a new sulphonylurea, glimepiride, and its metabolites. The assay involves extraction with diethyl ether, thermolysis of the sulphonylureas at 100 degrees C and trapping of the resulting amines with 2,4-dinitrofluorobenzene. The derivatives were quantitated on a reversed-phase column by absorbance at 350 nm using a step gradient for the three compounds in serum and an isocratic run for the metabolites in urine. Analogous compounds were used as internal standards. The detection limit was 5 ng/ml for glimepiride and metabolite II and 10 ng/ml for metabolite I using 1 ml of serum. The method has been applied to the analysis of serum and urine samples from pharmacokinetic studies in humans.  相似文献   

7.
8.
Bhatnagar RP  Trivedi RG  Bala Y 《Talanta》1970,17(4):249-253
Ion-exchange equilibrium distribution of some metal ions has been studied in nitrite media, with cation- as well as anion-exchangers. The distribution coefficients (K(D)) show the utility of a new nitrite medium which is a complexing medium for most transition metal ions giving anionic complexes in aqueous solution. Similar studies have been performed in aqueous ethanol. Increase in the concentration of ethanol led to increased complex formation and changed K(D) values.  相似文献   

9.
The behaviour of transplutonium elements (TPE) on cation and anion exchangers in aqueous alcoholic solutions of chlorides and nitrates of some alkali and alkaline earth metals as depending on different factors: salt concentration, content of alcohol and of acid in the solution as well as the nature of a cation has been studied. The data obtained were used to determine the optimal conditions of concentration of TPE on ion exchangers from solutions containing great quantities of salts. The advantages of the use of aqueous alcoholic solutions of nitric acid in the isolation of TPE from such solutions have been shown.  相似文献   

10.
A method for the determination of alprenolol and its 4-hydroxy metabolite has been developed. The urine sample is made alkaline with buffer (pH 12) and derivatized with 60 microliter of 2 M phosgene in toluene with vigorous shaking. In the presence of 2.5% methanol, an oxazolidineone methyl carbonate is formed from 4-hydroxy alprenolol. The now neutral derivatives are extracted with an equal volume of dichloromethane. After evaporation of the organic phase, the residue is taken up in a small volume of ethyl acetate and subjected to capillary column gas chromatography with CP-Sil 8 as the stationary phase. The precision was 2.1% at the 3.3 micrograms/ml level of the metabolite in urine (n = 8). The isopentylamino analogue was used as the internal standard.  相似文献   

11.
Two methods have been developed for the analysis of thiodiglycol sulphoxide, a metabolite of sulphur mustard, in urine. The first method recovers thiodiglycol sulphoxide from urine by extraction from a solid absorbent tube and clean up on Florisil. In the second method thiodiglycol sulphoxide is reduced to thiodiglycol with acidic titanium trichloride prior to extraction. This method detects thiodiglycol, thiodiglycol sulphoxide, and their acid-labile esters, as the single analyte thiodiglycol. In both cases the recovered analytes were converted to the bis(pentafluorobenzoyl) derivative of thiodiglycol and detected by gas chromatography-mass spectrometry using negative ion chemical ionisation. The limits of detection were 1 ng per 0.5-ml sample of urine. Urine from five normal human subjects showed low background levels of thiodiglycol sulphoxide in the range 2-8 ng/ml. However, a sixth subject was found to be excreting levels of thiodiglycol sulphoxide as high as 36 ng/ml. The first method has been used in toxicokinetic studies of sulphur mustard and the second method is intended to be used for the retrospective confirmation of mustard poisoning in casualties of chemical warfare.  相似文献   

12.
Individual high-performance liquid chromatographic (HPLC) methods have been developed for the determination of two major metabolites of lonapalene in rat urine. The highly unstable and polar 1,4-diketo-2,3-dihydroxy metabolite (II) is extracted from urine by two extraction columns (phenyl followed by silica), further purified by means of HPLC with a fully end-capped C18 HPLC column and quantified by an ultraviolet detector at 280 nm. Ascorbic acid is used as an antioxidant during extraction and overnight injection of II. Urine samples for total II (free plus conjugated) determination are incubated with arylsulfatase and beta-glucuronadase prior to extraction. The 1,4-diketo metabolite (III) is extracted from urine with a C18 extraction column, further purified with a C18 HPLC column, and quantified by an ultraviolet detector at 260 nm. The detection limit for both metabolites is 100 ng/ml of urine (signal-to-noise = 2.5). The methods were used to analyze urine samples from a long-term toxicology study of lonapalene in rats and to determine the linearity of dose-concentration relationships for both metabolites.  相似文献   

13.
High-performance liquid chromatographic (HPLC) methods using ultraviolet (UV) detection have been developed for the assay of the antibiotic imipenem (N-formimidoyl thienamycin) in human plasma and urine. A reversed-phase analytical column is employed in the plasma assay method and a cation-exchange column is used in the urine assay method. Both methods use borate buffer in the mobile phase. The method of preparation of human fluid samples for HPLC injection has been optimized with respect to the stability of imipenem in aqueous buffers, in morpholine buffer--ethylene glycol stabilizer, and in urine and plasma. Preparation of the samples before injection into the HPLC systems involves deproteination/filtration of the plasma/urine samples. The open lactam metabolite and the coadministered dehydropeptidase inhibitor, cilastatin sodium, do not interfere with the 313-nm detection of imipenem in either the plasma or the urine assay. Thienamycin, the precursor of imipenem and an impurity in imipenem formulations, is separated from the drug using both of these methods. Concentrations generated from the HPLC analysis of plasma and urine samples from two healthy volunteers compare favorably with results using a microbiological assay method. Correlation of the two methods gives r greater than or equal to 0.990 for both fluids.  相似文献   

14.
An efficient reversed-phase high-performance liquid chromatographic method has been developed for the determination of ethyl biscoumacetate (EBA) and its metabolite in human serum, using the mu Bondapak C18 column and methanol-water-phosphoric acid (56:46.8:0.2, v/v/v) as the mobile phase. This method permitted the determination of both EBA and a metabolite in human serum. The latter has been mentioned by other authors only in urine samples, where significant concentrations were found. Identification of the metabolite as 7-hydroxyethyl biscoumacetate was based on its chromatographic separation, followed by isolation from the eluate and direct mass spectrometric identification. It has been found that the higher EBA concentrations in human serum described by Brodie et al. [J. Pharmacol. Exp. Ther., 106 (1952) 453] were caused by the insufficient resolving power of the spectrophotometric method used, leading to overlapping of the UV spectra of the parent drug and its metabolite.  相似文献   

15.
A flow-fluorimetric high-performance liquid chromatographic assay for 6-methylthioguanine in urine has been developed. This compound is a major catabolite of 6-thioguanine, an important drug in cancer chemotherapy. The metabolite was extracted from alkaline urine with ethyl acetate which was injected onto a reversed-phase high-performance liquid chromatographic system for separation and detection. The method is simple, rapid and sensitive to below 500 ng ml-1 which is below the levels encountered following a therapeutic dose of 6-thioguanine. Another metabolite was chromatographically separated from 6-methylthioguanine and partially characterised.  相似文献   

16.
A rapid, specific and sensitive method using reversed phase HPLC for the simultaneous determination of clozapine and its two metabolites in serum and urine has been developed. The mobile phase was a mixture of 67% (v/v) methanol in water containing 0.4% tetramethylethylenediamine and 0.32% acetic acid (pH 5.5). The influence of methanol content, the pH of the mobile phase and the effect of adding alkylammonium ions as peak tailing reducer in the mobile phase have been investigated. The solvent for extracting clozapine from serum and urine was ether. 50 microliters of 0.25 M H2SO4 solution was used to redissolve the dry residue to eliminate the endogenous compounds which could otherwise be eluted together with clozapine from the HPLC column. The analysis of a single sample was accomplished within half an hour. The identities of the chromatographic peaks of clozapine and its N-demethyl metabolite collected from the patient urine sample were confirmed by mass spectrometry. The method is sufficiently sensitive (5 ng/ml) and reproducible (CV 2.9%-6.7%) for clinical and pharmacokinetic studies, and preliminary results in these respects are presented.  相似文献   

17.
Summary In previous pharmacokinetic studies tiopronin, a drug used for effective treatment of cystinuria and rheumatoid arthritis, and its metabolite 2-mercaptopropionic acid were analysed by conventional liquid chromatography with pre- and post-column derivatization and UV detection. Now a novel HPLC-coupled chemiluminescence-flow-injection analysis (CL-FIA) method has been developed for the determination of tiopronin and 2-mercaptopropionic acid in urine. The method is based on chemiluminescence from a Ce(IV) oxidation system sensitized by quinine, as proposed earlier by this group, and flow-injection analysis. The method, which has the advantages of high sensitivity and selectivity, simple sample treatment and prompt production of results, has also been preliminarily adapted for pharmacokinetic study of tiopronin in urine.  相似文献   

18.
ABT-869 (A-741439) is an investigational new drug candidate under development by Abbott Laboratories. ABT-869 is hydrophobic, but is oxidized in the body to A-849529, a hydrophilic metabolite that includes both carboxyl and amino groups. Poor solubility of ABT-869 in aqueous matrix causes simultaneous analysis of both ABT-869 and its metabolite within the same extraction and injection to be extremely difficult in human urine. In this paper, a high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method has been developed and validated for high-speed simultaneous quantitation of the hydrophobic ABT-869 and its hydrophilic metabolite, A-849529, in human urine. The deuterated internal standards, A-741439D(4) and A-849529D(4), were used in this method. The disparate properties of the two analytes were mediated by treating samples with acetonitrile, adjusting pH with an extraction buffer, and optimizing the extraction solvent and mobile phase composition. For a 100 microL urine sample volume, the lower limit of quantitation was approximately 1 ng/mL for both ABT-869 and A-849529. The calibration curve was linear from 1.09 to 595.13 ng/mL for ABT-869, and 1.10 to 600.48 ng/mL for A-849529 (r2 > 0.9975 for both ABT-869 and A-849529). Because the method employs simultaneous quantification, high throughput is achieved despite the presence of both a hydrophobic analyte and its hydrophilic metabolite in human urine.  相似文献   

19.
1-Hydroxypyrene is a metabolite of pyrene, a member of the class of polycyclic aromatic hydrocarbons (PAHs) whose toxic properties in some cases include carcinogenicity. The determination of 1-hydroxypyrene in human urine is used as a biological indicator for exposure to PAHs, which is related to the combustion of organic materials, like smoking, living in urban environments, and eating grilled or smoked food. The determination of 1-hydroxypyrene by high-performance liquid chromatography (HPLC) with fluorescence detection has very good sensitivity but it is not highly specific: this can reduce accuracy in the quantitative determination of low levels of analyte in a complex matrix like urine. An HPLC method that uses triple quadrupole mass detection has been validated with the objective both to improve the signal-to-noise (S/N) ratio and to achieve the maximum specificity for the analyte in those urine samples that are richer in possible inteferents. The calibration range for 1-hydroxypyrene is from 0.005-0.1 microg/L in the urine of non-smoking healthy volunteers. After solid-phase extraction, samples were analyzed by HPLC/tandem mass spectrometry (MS/MS) in the multiple reaction monitoring (MRM) mode. In order to obtain reliable results quantitative analysis must be performed by means of the internal standard method (we used deuterium-labelled 1-hydroxypyrene): the method accuracy is not less than 85%. The S/N ratio at a concentration of 0.1 microg/L is about 10, and therefore this can be considered the lowest limit of quantitation. The method performance does not change if urine samples are measured using a calibration curve prepared in methanol, thus reducing the time of analysis and costs.  相似文献   

20.
Armitage GM  Lyle SJ  Nair VC 《Talanta》1976,23(1):58-61
The pH-dependent distribution of carrier-free radioisotopes between aqueous phases at constant ionic strength and polystyrene-divinylbenzene type exchangers reveals the presence of a secondary exchange function attributable to carboxyl groups. Cation- and anion-exchangers of the sulphonate and quaternary ammonium types possess this additional cation-exchange capacity which is, however, relatively very low in currently available commercial resins. Its influence on separations involving radioisotopes of high specific activity is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏