首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The fast luminosity monitor counting the γ photons above a given energy threshold emitted from radiative Bhabha scattering has been operated in the BEPC Ⅱ to measure the relative luminosity bunch by bunch for the first time and used successfully in beam tuning of BEPC Ⅱ. In the relative mode the monitor is able to deliver the relative luminosities with an accuracy of 0.8 %. By steering the electron beam while observing the counting rate changes of the monitor the horizontal and vertical sizes of the bunch spots can be estimated as: Sxe+ =Sxe =0.356 mm, Sye+ =Sye- =0.011 mm.  相似文献   

2.
BEPCⅡ is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPCⅡ. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPCⅡ timing system can also use the bunch current database to decide which bucket needs to refill to implement ``top-off' njection.  相似文献   

3.
The BEPCⅡ Luminosity Monitor (BLM) monitors relative luminosity per bunch. The counting rates of gamma photons, which are proportional to the luminosities from the BLM at the center of mass system energy of the ψ(3770) resonance, are obtained with a statistical error of 0.01% and a systematic error of 4.1%. Absolute luminosities are also determined by the BESⅢ End-cap Electro-Magnetic Calorimeter (EEMC) using Bhabha events with a statistical error of 2.3% and a systematic error of 3.5%. The calibration constant between the luminosities obtained with the EEMC and the counting rates of the BLM are found to be 0.84±0.03 (×1026 cm-2·count-1). With the calibration constant, the counting rates of the BLM can be scaled up to absolute luminosities.  相似文献   

4.
Electron Cloud Instability has been studied in the operation of BEPC. The BEPCⅡ began the commissioning in November 2006 and the positron beam current has reached 500 mA. Because of such a high beam current, some instabilities such as ECI, bunch lengthening et al, have appeared during the operation. The experimental investigation on ECI during the commissioning of BEPCⅡ will be reported in this paper.  相似文献   

5.
Electron Cloud Instability has been studied in the operation of BEPC. The BEPCⅡ began the commissioning in November 2006 and the positron beam current has reached 500 mA. Because of such a high beam current, some instabilities such as ECI, bunch lengthening et al, have appeared during the operation. The experimental investigation on ECI during the commissioning of BEPCⅡ will be reported in this paper.  相似文献   

6.
BEPCⅡ, the upgrade project of Beijing Electron Positron Collider (BEPC), is an accelerator with large beam current and high luminosity, so an efficient and stable injector is required. Several beam diagnostic and monitoring instruments are used. A new diagnostic instrument — wire scanner, has been designed and will be used to measure the profile of the linac beam of BEPCⅡ. This paper describes the prototype of this system and the cause of heat generating of the wire. Some simulation results of the heat and force by using finite element method software—ANSYS®,2) are presented and discussed.  相似文献   

7.
Commissioning of electron cooling in CSRe   总被引:1,自引:0,他引:1  
The 400 MeV/u 12C6+ ion beam was successfully cooled by the intensive electron beam near 1 A in CSRe.The momentum cooling time was estimated near 15 s.The cooling force was measured in the cases of difierent electron beam profiles,and the difierent angles between the ion beam and electron beam.The lifetime of the ion beam in CSRe was over 80 h.The dispersion in the cooling section was confirmed as positive close to zero.The beam sizes before cooling and after cooling were measured by the moving screen.The beam diameter after cooling was about 1 mm.The bunch length was measured with the help of the signals from the beam position monitor.The difiusion was studied in the absence of the electron beam.  相似文献   

8.
Physics opportunity in the charm and τ energy region calls for higher luminosity of the Beijing Electron-Positron Collider (BEPC).The BEPC has experienced continuous improvement since its completion in 1988.BEPCII,as a major upgrading project of the BEPC,aims at enhancing its luminosity of factor 30–100,following the principle of "one machine,two purposes" as adopted in BEPC,so that both high energy physics and synchrotron radiation experiments can be carried out with BEPCII.From the BEPC to BEPCII,the double-ring scheme with multi-bunch e +-e-collision in the large crossing angle was studied in comparison with the single-ring pretzel scheme.For the dedicated synchrotron radiation operation,artful "bridges" are designed to connect two halves of the outer ring in both the southern and the northern crossing regions.This paper reviews the studies on the BEPC upgrade from pretzel to double-ring structure of BEPCII.  相似文献   

9.
A passive higher harmonic cavity (HHC) will be used in the Hefei Light Source II Project (HLS-Ⅱ) to lengthen the bunch and consequently increase the beam lifetime dominated by Touschek scattering. The effects of constant voltage and constant detuning have been calculated and compared over the operating current from 0.4 to 0.2 A on the bunch lengthening for the passive normal conducting harmonic cavity system in HLS-Ⅱ. The results show that the bunch shape has less change and the lifetime improvement factors are not less than 2.7 over the beam currents for the constant voltage case. The constant voltage operating scheme may be applied to our machine.  相似文献   

10.
During the 1 st and 2 nd stages of the commissioning of the upgrade project of the Beijing Electron Positron Collider (BEPCⅡ), which started on Nov. 12, 2006 and Oct. 24, 2007, respectively, we got the luminosity one tenth of its design value, provided beams to synchrotron radiation users for about 4 months, and studied beam dynamics as well. In this paper, some beam dynamics studies on the storage rings and their preliminary results are given.  相似文献   

11.
Using the Hefei Light Source phase Ⅱ project (HLS- Ⅱ) as an example, a theoretical analysis of shortening the bunch lengths using a higher harmonic cavity (HHC) is given. The threshold voltage of an active HHC and the threshold tuning angle of a passive HHC are first analysed. The optimum tuning angle for the constant detuning scenario and the optimum harmonic voltage for the constant voltage scenario are presented. The calculated results show that the reduced bunch length is about half that of the nominal bunch. The bunch lengths vary from 11 mm at 0.1 A to 7 mm at 0.4 A for the constant detuning scenario, while the bunch lengths are around 7 mm over the beam current range for the constant voltage scenario. In addition, the synchrotron frequency spread is increased. It indicates that HHC may be used to reduce the bunch length and increase the Landau damping of synchrotron oscillations in a storage ring.  相似文献   

12.
The length of electron beam from a photocathode RF gun is determined by a spectrometer, according to the relative energy spread induced by the bunch length during the acceleration in a linac. For a photocathode RF gun, different laser injected phase and beam charge are studied. The compression is changed for the different laser phases, as from 10° to 30°, and the bunch length is lengthened due to the strong longitudinal space charge force, caused by the increased charge.  相似文献   

13.
BEPCⅡ is a double ring e+ecollider with high beam currents and luminosity,so the high beamrelated backgrounds may disturb the detector.In order to have a good quality of data taking,backgrounds should be kept at a level as low as possible.A series of collimators are designed and installed in both the e+ and erings.Two of the collimators are horizontally movable,each for one ring,about 8 m upstream from the interaction point.Experiments have been done to identify the e-ectiveness of the movable collimators with different apertures and beam currents.The results show that the movable collimators are very effective and can reduce as much as about 50% of beam-related backgrounds.  相似文献   

14.
Using the Hefei Light Source phaseⅡproject(HLS-Ⅱ)as an example,a theoretical analysis of shortening the bunch lengths using a higher harmonic cavity(HHC)is given.The threshold voltage of an active HHC and the threshold tuning angle of a passive HHC are first analysed.The optimum tuning angle for the constant detuning scenario and the optimum harmonic voltage for the constant voltage scenario are presented.The calculated results show that the reduced bunch length is about half that of the nominal bunch.The bunch lengths vary from 11 mm at 0.1 A to 7 mm at 0.4 A for the constant detuning scenario,while the bunch lengths are around 7 mm over the beam current range for the constant voltage scenario.In addition,the synchrotron frequency spread is increased.It indicates that HHC may be used to reduce the bunch length and increase the Landau damping of synchrotron oscillations in a storage ring.  相似文献   

15.
The new beam position monitor (BPM) system of the injector at the upgrade project of the Hefei Light Source (HLS Ⅱ) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.  相似文献   

16.
Fluorescence lifetime measurement in the time domain requires excitation from a well separated single bunch using synchrotron light sources. In the colliding mode of the Beijing Electron Positron Collider Ⅱ (BEPCⅡ), a hybrid filling pattern was realized such that a single bunch was placed in the middle of a large gap between two multi-bunch groups. Detection of fluorescence lifetime, based on the excitation of the light pulse from this designated single-bunch, was established at Beamline 4B8 of the Beijing Synchrotron Radiation Facility (BSRF). The timing signal of the BEPCII was utilized as a trigger to gate this fluorescence event. L-Tryptophan amino acid, a known lifetime standard, was selected to assess the lifetime measurement performance. The measured lifetime was consistent in both colliding and single-bunch mode with the time resolution down to 450 ps. Moreover, both the bunch purity and the fine structure of the hybrid filling pattern were characterized.  相似文献   

17.
To monitor the integral dose deposited in the BESⅢ electromagnetic calorimeter whose performance degrades due to exposure to the BEPC Ⅱ background, a 400 nm IMPL RadFET dosimeter-based integral dose online monitor system is built, After calibration with the ^60Co source and verification with TLD in the pulse radiation fields, an experiment was arranged to measure the BEPC Ⅱ background online. The results are presented.  相似文献   

18.
There has recently been a dramatic renewal of interest in hadron spectroscopy and charm physics. This renaissance has been driven in part by the discovery of a plethora of charmonium-like XYZ states at BESⅢ and B factories, and the observation of an intriguing proton-antiproton threshold enhancement and the possibly related X(1835) meson state at BESⅢ, as well as the threshold measurements of charm mesons and charm baryons. We present a detailed survey of the important topics in tau-charm physics and hadron physics that can be further explored at BESⅢ during the remaining operation period of BEPCⅡ. This survey will help in the optimization of the data-taking plan over the coming years, and provides physics motivation for the possible upgrade of BEPCⅡ to higher luminosity.  相似文献   

19.
RF deflectors can be used for bunch length measurement with high resolution. This paper describes a completed S-band traveling wave RF deflector and the bunch length measurement of the electron beam produced by the photocathode RF gun of the Shanghai DUV-FEL facility. This is the first time that such a transverse RF deflector has been developed and used to measure the bunch length of picosecond order in China. The deflector's VSWR is 1.06, the whole attenuation 0.5 dB, and the bandwidth 4.77 MHz for VSWR less than 1.1. With a laser pulse width of 8.5 ps, beam energy of 4.2 MeV, and bunch charge of 0.64 nC, the bunch lengths for different RF input power into the deflector were measured, and an averaged rms bunch length of 5.25 ps was obtained. A YAG crystal is used as a screen downstream of the deflector, with the calibrated value of 1 pix = 136 μm.  相似文献   

20.
A simulation code that executes the tracking of longitudinal oscillations of the bunches for the double rf system of the Hefei Light Source Ⅱ Project (HLS-Ⅱ) is presented to estimate the mean beam lifetime and the Robinson instabilities. The tracking results show that the mean beam lifetime is in agreement with the analytical results and the system is stable when we tune the harmonic cavity in the optimum lengthening conditions. Moreover, the simulated results of the asymmetric fill pattern show that some bunches are compressed only with a 7% gap (3 gaps), which will lead to the reduction in the mean bunch lengthening and potential beam lifetime. It is demonstrated that HLS-Ⅱ with a passive higher harmonic cavity is not suitable for operating in an asymmetric fill pattern.  相似文献   