首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
For future medical diagnostics and drug screening, chip-based single cell analysis based on a micro-electro-mechanical system (MEMS) technology will be essential. Chip-based single cell analysis enables to perform exhaustive analysis of huge numbers of sample cells, reducing sample volume and analysis time and lowering the costs. However, the previously reported chip-based single cell analysis has some disadvantages of cell alignment, such as troublesome sample handling and long cell alignment time onto the chip. In this study, a cell alignment method and device based on electrically-generated air bubbles is presented. For practical realization, the cell alignment was carried out using microbeads. With this technique, the chip-based single cell analysis will be more simplified for medical and drug delivery applications.  相似文献   

2.
Oh KW  Park C  Namkoong K  Kim J  Ock KS  Kim S  Kim YA  Cho YK  Ko C 《Lab on a chip》2005,5(8):845-850
We report a practical world-to-chip microfluidic interfacing method with built-in valves suitable for microscale multichamber chip-based assays. One of the primary challenges associated with the successful commercialization of fully integrated microfluidic systems has been the lack of reliable world-to-chip microfluidic interconnections. After sample loading and sealing, leakage tests were conducted at 100 degrees C for 30 min and no detectable leakage flows were found during the test for 100 microchambers. To demonstrate the utility of our world-to-chip microfluidic interface, we designed a microscale PCR chip with four chambers and performed PCR assays. The PCR results yielded a 100% success rate with no contamination or leakage failures. In conclusion, we have introduced a simple and inexpensive microfluidic interfacing system for both sample loading and sealing with no dead volume, no leakage flow and biochemical compatibility.  相似文献   

3.
In this paper we report an innovative use of Poly(DiMethyl)Siloxane (PDMS) to design a microfluidic device that combines, for the first time, in one single reaction chamber, DNA purification from a complex biological sample (blood) without elution and PCR without surface passivation agents. This result is achieved by exploiting the spontaneous chemical structure and nanomorphology of the material after casting. The observed surface organization leads to spontaneous DNA adsorption. This property allows on-chip complete protocols of purification of complex biological samples to be performed directly, starting from cells lysis. Amplification by PCR is performed directly on the adsorbed DNA, avoiding the elution process that is normally required by DNA purification protocols. The use of one single microfluidic volume for both DNA purification and amplification dramatically simplifies the structure of microfluidic devices for DNA preparation. X-Ray Photoelectron Spectroscopy (XPS) was used to analyze the surface chemical composition. Atomic Force Microscopy (AFM) and Field Emission Scanning Electron Microscopy (FESEM) were employed to assess the morphological nanostructure of the PDMS-chips. A confocal fluorescence analysis was utilized to check DNA distribution inside the chip.  相似文献   

4.
DNA analysis with the polymerase chain reaction (PCR) has become a routine part of medical diagnostics, environmental inspections, food evaluations, and biological studies. Furthermore, the development of a microscale PCR chip is an essential component of studies aimed at integrating PCR into a micro total analysis system (μ-TAS). However, the occurrence of air bubbles in microchannels complicates this process. In this study, we investigated a new technique based on the fluid dynamics of laminar flow that utilizes a small amount of mineral oil at the beginning of sample injection to prevent air bubbles from occurring in microchannels. We also further optimized the pressure, the length of the pressurizing channel and the volume of oil, thus making our microfluidic device more useful for high-temperature PCR. Additionally, quantitative continuous-flow PCR was performed using the optimized PCR chip in order to detect genetically modified (GM) maize. DNA was extracted from GM maize, MON 810, and non-GM maize at several concentrations from 0% (w/v) to 100% (w/v). The DNA amplification signals were then analyzed on the PCR chip using a laser-based system. The signal from our microfluidic PCR chip was found to increase in direct proportion to the initial GM maize concentration.  相似文献   

5.
集成核酸提取的实时荧光PCR微全分析系统将核酸提取、PCR扩增与实时荧光检测进行整合,在同一块微流控芯片上实现了核酸分析过程的全自动和全封闭,具有试剂用量少、分析速度快、操作简便等优点。本研究采用微机械加工技术制作集成核酸提取微流控芯片的阳极模,使用组合模具法和注塑法制作具有3D通道的PDMS基片,与玻璃基底通过等离子体键合封装成集成核酸提取芯片。构建了由微流体速度可调节(0~10 mL/min)的驱动控制装置、温控精度可达0.1℃的TEC温控平台、CCD检测功能模块等组成的微全分析系统。以人类血液裂解液为样品,采用硅胶膜进行芯片上核酸提取。系统根据设置好的时序自动执行,以2 mL/min的流体驱动速度完成20μL裂解液上样、清洗;以1 mL/min的流体驱动速度完成DNA洗脱,抽取PCR试剂与之混合注入到反应腔。提取的基因组DNA以链上内参基因GAPDH为检测对象,并以传统手工提取为对照,在该系统平台上进行PCR扩增和熔解曲线分析实验。片上PCR扩增结果显示,扩增曲线明显,Ct值分别为25.3和26.9。扩增产物进行熔解曲线分析得到的熔解温度一致,均为89.9℃。结果表明,此系统能够自动化、全封闭的在微流控芯片上完成核酸提取、PCR扩增与实时定量分析。  相似文献   

6.
A sample pretreatment microfluidic chip was described based on the principle of solid phase extraction and micro electro mechanical system technology. Oxidized porous silicon with the large surface area as the solid phase matrix for absorption of DNA from a biological sample can greatly improve the DNA yield. The factors that could affect the DNA yield were analyzed and the preparation technology and the experiment procedure were improved. The DNA purification process from the rat peripheral blood can be achieved and the DNA yield is 24 ng/(μL whole blood), which can reach the level of the commercial DNA purification kits. Furthermore, the DNA extracted from the whole blood can be amplified by polymerase chain reaction, which can achieve a high efficiency of the amplification. Translated from Chemical Journal of Chinese Universities, 2006, 27(4) (in Chinese)  相似文献   

7.
A valveless microdevice has been developed for the integration of solid phase extraction (SPE) and polymerase chain reaction (PCR) on a single chip for the short tandem repeat (STR) analysis of DNA from a biological sample. The device consists of two domains--a SPE domain filled with silica beads as a solid phase and a PCR domain with an ~500 nL reaction chamber. DNA from buccal swabs was purified and amplified using the integrated device and a full STR profile (16 loci) resulted. The 16 loci Identifiler? multiplex amplification was performed using a non-contact infrared (IR)-mediated PCR system built in-house, after syringe-driven SPE, providing an ~80-fold and 2.2-fold reduction in sample and reagent volumes consumed, respectively, as well as an ~5-fold reduction in the overall analysis time in comparison to conventional analysis. Results indicate that the SPE-PCR system can be used for many applications requiring genetic analysis, and the future addition of microchip electrophoresis (ME) to the system would allow for the complete processing of biological samples for forensic STR analysis on a single microdevice.  相似文献   

8.
Zhang S  Van Pelt CK  Henion JD 《Electrophoresis》2003,24(21):3620-3632
We report a method using a fully automated chip-based nanoelectrospray system for two-dimensional (2-D) gel sample analyses with mass spectrometric detection. The automated nanoelectrospray system, consisting of the NanoMate and electrospray ionization (ESI) chip, serves as both an autosampler and nanoESI source. This infusion system aspirates samples from a 96-well plate using disposable pipette tips and then delivers these samples sequentially to an ESI chip. This chip is a fully integrated monolithic device consisting of a 10x10 array of nozzles. The automated nanoelectrospray system is easily controlled through software, permitting the user to select the number of samples to be analyzed, the volume of sample to aspirate, the spray voltage, and analysis time. The system offers all the advantages of conventional nanoelectrospray plus automated, high-throughput analyses without analyte carryover. The system was used for a protein identification study of 2-D gel spots of both Escherichia coli and yeast crude cell extracts. The identification of 50 spots from E. coli crude cell extract and 27 spots from yeast extract is presented, demonstrating the powerful combination of the automated nanoESI system, the Thermo Finnigan LCQ Deca ion-trap mass spectrometer, and SEQUEST search software. In addition, the effects of silver staining and colloidal Coomassie blue staining of 2-D gel spots on the detection sensitivity and protein sequence coverage are compared and discussed. Furthermore, the comparison results using the multiwell microscale preparation kit versus manual extraction for in-gel samples are presented.  相似文献   

9.
Gansen A  Herrick AM  Dimov IK  Lee LP  Chiu DT 《Lab on a chip》2012,12(12):2247-2254
This paper describes the realization of digital loop-mediated DNA amplification (dLAMP) in a sample self-digitization (SD) chip. Digital DNA amplification has become an attractive technique to quantify absolute concentrations of DNA in a sample. While digital polymerase chain reaction is still the most widespread implementation, its use in resource-limited settings is impeded by the need for thermal cycling and robust temperature control. In such situations, isothermal protocols that can amplify DNA or RNA without thermal cycling are of great interest. Here, we accomplished the successful amplification of single DNA molecules in a stationary droplet array using isothermal digital loop-mediated DNA amplification. Unlike most (if not all) existing methods for sample discretization, our design allows for automated, loss-less digitization of sample volumes on-chip. We demonstrated accurate quantification of relative and absolute DNA concentrations with sample volumes of less than 2 μl. We assessed the homogeneity of droplet size during sample self-digitization in our device, and verified that the size variation was small enough such that straightforward counting of LAMP-active droplets sufficed for data analysis. We anticipate that the simplicity and robustness of our SD chip make it attractive as an inexpensive and easy-to-operate device for DNA amplification, for example in point-of-care settings.  相似文献   

10.
He QH  Fang Q  Du WB  Huang YZ  Fang ZL 《The Analyst》2005,130(7):1052-1058
An automated and continuous sample introduction system for microfluidic chip-based capillary electrophoresis (CE) was developed in this work. An efficient world-to-chip interface for chip-based CE separation was produced by horizontally connecting a Z-shaped fused silica capillary sampling probe to the sample loading channel of a crossed-channel chip. The sample presentation system was composed of an array of bottom-slotted sample vials filled alternately with samples and working electrolyte, horizontally positioned on a programmable linearly moving platform. On moving the array from one vial to the next, and scanning the probe, which was fixed with a platinum electrode on its tip, through the slots of the vials, a series of samples, each followed by a flow of working electrolyte was continuously introduced electrokinetically from the off-chip vials into the sample loading channel of the chip. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine and phenylalanine with LIF detection, by continuously introducing a train of different samples. Employing 4.5 kV sampling voltage (1000 V cm(-1) field strength) for 30 s and 1.8 kV separation voltage (400 V cm(-1) field strength) for 70 s, throughputs of 36 h(-1) were achieved with <1.0% carryover and 4.6, 3.2 and 4.0% RSD for arginine, FITC and phenylalanine, respectively (n = 11). Net sample consumption was only 240 nL for each sample.  相似文献   

11.
We have developed a microfluidic device operating at a planar surface instead of a closed channel network. The fluid is transported in single droplets using surface acoustic waves (SAW) on a piezoelectric LiNbO(3) substrate. The surface of the piezo is chemically structured to induce high contact angles of the droplets or enclose areas where the liquid can wet the substrate. Combining the SAW technique with thin film resistance heaters, a biological analysis chip with integrated DNA amplification by PCR and hybridization was designed. To prevent evaporation of the PCR reagents at high temperatures the sample is enclosed in droplets of mineral oil. On this chip the SAW resolves dried primers, shifts the oil capped liquid between the two heaters and mixes during hybridization. The chip is able to perform a highly sensitive, fast and specific PCR with a volume as low as 200 nl. During the temperature cycles an online monitoring of the DNA concentration is feasible with an optical unit, providing a sensitivity of 0.1 ng. After PCR the product is moved to the second heater for the hybridization on a spotted DNA array. With our chip we were able to detect a single nucleotide polymorphism (SNP) responsible for the Leiden Factor V syndrome from human blood.  相似文献   

12.
聚合酶链式反应(polymerase chain reaction,PCR)是一种重要的体外DNA扩增技术,在生物化学、分析化学以及分子生物学等领域中得到广泛的应用.基于微电子机械系统(Microelectromechanical system,MEMS)技术构建而成的PCR生物微流体芯片由于具有反应速度快、样品消耗少以及所占空间体积少等优点而倍受人们亲睐.然而,伴随之较大比表面积以及其所用的裸露衬底材料常常抑制PCR反应,从而导致PCR不能顺利进行.本文结合本试验室的研究工作,综述了PCR生物微流体芯片中为了获得“友善”的PCR扩增体系而采取的表面钝化技术,主要包括表面钝化的必要性、静力学/动力学表面钝化技术以及硅相关材料对PCR抑制的机制等等.  相似文献   

13.
We present a fully automated DNA purification module comprised of a micro-fabricated chip and sequential injection analysis system that is designed for use within autonomous instruments that continuously monitor the environment for the presence of biological threat agents. The chip has an elliptical flow channel containing a bed (3.5 x 3.5 mm) of silica-coated pillars with height, width and center-to-center spacing of 200, 15, and 30 microm, respectively, which provides a relatively large surface area (ca. 3 cm(2)) for DNA capture in the presence of chaotropic agents. We have characterized the effect of various fluidic parameters on extraction performance, including sample input volume, capture flow rate, and elution volume. The flow-through design made the pillar chip completely reusable; carryover was eliminated by flushing lines with sodium hypochlorite and deionized water between assays. A mass balance was conducted to determine the fate of input DNA not recovered in the eluent. The device was capable of purifying and recovering Bacillus anthracis genomic DNA (input masses from 0.32 to 320 pg) from spiked environmental aerosol samples, for subsequent analysis using polymerase chain reaction-based assays.  相似文献   

14.
《Analytical letters》2012,45(1):12-21
In this article, we introduce a novel real-time polymerase chain reaction (PCR) chip, which integrated the pretreatment of biological sample, the PCR reaction, and the real-time fluorescent detection. We have built a dam in the chamber of the chip and formed a crack underneath it to separate the white blood cell from the whole blood. After the lysis of white blood cells, which were separated from the whole blood, the real-time PCR reaction was produced by the integrated microheaters and resistance temperature detector (RTD), and the real-time fluorescent measurement was made in the identical chamber. Compared with conventional tubular PCR analysis, this chip-based PCR analysis can obtain more accurate results with a smaller amount of samples and reagents. We have designed the corresponding detection and control platform, which is composed of syringe pump module, temperature control module, and fluorescence sampling module. We also used the constructed chip for the examination of HLA-B27 related to ankylosing spondylitis, and the results show that the chip is available for the accurate and rapid analysis of HLA-B27 in whole blood.  相似文献   

15.
This paper reports the development of a disposable, integrated biochip for DNA sample preparation and PCR. The hybrid biochip (25 × 45 mm) is composed of a disposable PDMS layer with a microchannel chamber and reusable glass substrate integrated with a microheater and thermal microsensor. Lysis, purification, and PCR can be performed sequentially on this microfluidic device. Cell lysis is achieved by heat and purification is performed by mechanical filtration. Passive check valves are integrated to enable sample preparation and PCR in a fixed sequence. Reactor temperature is needed to lysis and PCR reaction is controlled within ±1°C by PID controller of LabVIEW software. Buccal epithelial cell lysis, DNA purification, and SY158 gene PCR amplification were successfully performed on this novel chip. Our experiments confirm that the entire process, except the off‐chip gel electrophoresis, requires only approximately 1 h for completion. This disposable microfluidic chip for sample preparation and PCR can be easily united with other technologies to realize a fully integrated DNA chip.  相似文献   

16.
Genotyping from saliva with a one-step microdevice   总被引:1,自引:0,他引:1  
Pjescic I  Crews N 《Lab on a chip》2012,12(14):2514-2519
This paper presents a disposable microfluidic device for on-chip lysing, PCR, and analysis in one continuous-flow process. Male-female sex determination was performed with human saliva in less than 20 min from spit to finish, and requiring only seconds of manual sample handling. This genetic analysis was based on the amplification and detection of the DYZ1 repeat region unique to the Y-chromosome. The flow-through microfluidic chip consisted of a single serpentine channel designed to guide samples through 42 heating and cooling cycles. Cycling was performed by matching the local channel geometry to a steady-state temperature gradient established across the microfluidic chip. 38 channel segments were designed for rapid low volume PCR, and four were optimized for spatial DNA melting analysis. Fluorescence detection was used to monitor the amplification and to capture the melting signature of the amplicon was performed with a basic 8-bit CCD camera. The microfluidic device itself was fabricated from microscope slides and a double-sided tape. The simplicity of the system and its robust performance combine in an elegant solution for lab-on-a-chip genetic analysis.  相似文献   

17.
Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.  相似文献   

18.
The application of microfluidic devices for DNA amplification has recently been extensively studied. Here, we review the important development of microfluidic polymerase chain reaction (PCR) devices and discuss the underlying physical principles for the optimal design and operation of the device. In particular, we focus on continuous-flow microfluidic PCR on-chip, which can be readily implemented as an integrated function of a micro-total-analysis system. To overcome sample carryover contamination and surface adsorption associated with microfluidic PCR, microdroplet technology has recently been utilized to perform PCR in droplets, which can eliminate the synthesis of short chimeric products, shorten thermal-cycling time, and offers great potential for single DNA molecule and single-cell amplification. The work on chip-based PCR in droplets is highlighted.  相似文献   

19.
A sequential injection analysis (SIA) system based on polydimethylsiloxane (PDMS) chip with integrated pneumatic-actuated valves was developed. A novel SIA operation mode using multiphase laminar flow effect and pneumatic microvalve control was proposed. The sample and reagent solutions were synchronously loaded and injected in the chip-based sample injection module instead of multi-step sequential injection by a multiposition valve and a reciprocating pump as in conventional SIA system. The sample and reagent injection volumes were reduced to ca. 1.1 nL. The present system has the advantages of simple structure, fast and convenient operation, low sample and reagent consumption, and high degree of integration and automation. The system operation conditions were optimized using fluorescein as model sample. Its feasibility in biological analysis was preliminarily demonstrated in enzyme inhibition assay.  相似文献   

20.
Chips and Qi: microcomponent-based analysis in traditional Chinese medicine   总被引:1,自引:0,他引:1  
Over the last 50 years or so Traditional Chinese medicine (TCM) has been subject to intensive basic and clinical research. Although the effectiveness and remarkable safety of TCM have been documented after controlled clinical studies, there are several herbal and animal parts that are toxic or difficult to identify. DNA polymorphism-based assays have recently been developed for the identification of herbal medicines. In this approach, small amounts of DNA are amplified by the polymerase chain reaction and the reactions products are analyzed by gel electrophoresis, sequencing, or hybridization with species-specific probes. With the DNA based identification of TCM materials as an example, chip-based analytical micro devices were developed with the goal of fabricating an integrated device that will enable sample preparation, amplification, and analysis on a single microchip-based device ("lab-on-a-chip"). The application of a silicon-based polymerase chain reaction microreactor and a DNA microarray for the DNA sequence-based identification of toxic medicinal plants is reported here.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号