首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Miniaturization of separation columns implies equally reduced vol- umes of injectors, detectors, and the connecting channels. Planar chip technology provides a powerful means for the fabrication of micron-sized structures such as channels. This is demonstrated by two examples. An optical absorbance detector chip exhibits the expected behavior of a 1 mm optical path length cell despite its volume of 1 nL. A capillary electrophoresis device allows integrated injections of 100 pL samples, efficiencies of 70,000 to 160,000 theoretical plates in 10 to 20 seconds, and external laser-induced fluorescence detection at any capillary length of choice between 5 and 50 mm.  相似文献   

2.
Parallel analysis of biomolecules on a microfabricated capillary array chip   总被引:2,自引:0,他引:2  
Shen Z  Liu X  Long Z  Liu D  Ye N  Qin J  Dai Z  Lin B 《Electrophoresis》2006,27(5-6):1084-1092
This paper focused on a self-developed microfluidic array system with microfabricated capillary array electrophoresis (mu-CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda-lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high-voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.  相似文献   

3.
We use direct femtosecond laser writing to integrate optical waveguides into a commercial fused silica capillary electrophoresis chip. High-quality waveguides crossing the microfluidic channels are fabricated and used to optically address, with high spatial selectivity, their content. Fluorescence from the optically excited volume is efficiently collected at a 90° angle by a high numerical aperture fiber, resulting in a highly compact and portable device. To test the platform we performed electrophoresis and detection of a 23-mer oligonucleotide plug. Our approach is quite powerful because it allows the integration of photonic functionalities, by simple post-processing, into commercial LOCs fabricated with standard techniques. Figure Femtosecond laser written waveguides can selectively excite fluorescence in a microfluidic channel of a commercial lab-on-a-chip. A compact scheme for on-chip detection by laser induced fluorescence is applied to capillary electrophoresis of a 23-mer Cy3-labeled oligonucleotide  相似文献   

4.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

5.
Ueda M  Kiba Y  Abe H  Arai A  Nakanishi H  Baba Y 《Electrophoresis》2000,21(1):176-180
A laser-induced fluorescence detection system coupled with a highly sensitive silicon-intensified target (SIT) camera is successfully applied to the imaging of a band for DNA fragment labeling by fluorescence dye in a microchannel, and to the visualizing of the separation process on a microfabricated chip. We demonstrated that an only 6 mm separation channel is sufficient for the separation of triplet repeat DNA fragment and DNA molecular marker within only 12 s. The separation using the microfabricated capillary electrophoresis device is confirmed to be at least 18 times faster than the same separation carried out by conventional capillary electrophoresis with 24.5 cm effective length. The use of a short capillary with 8.5 cm effective length is also efficient for fast separation of DNA; however, the microchip technology is even faster than capillary electrophoresis using a short capillary.  相似文献   

6.
利用模拟仿真软件模拟了死体积对于电泳分离的影响,并提出了一种实现聚甲基丙烯酸甲酯(Poly-methylmethacrylate,PMMA)电泳芯片与毛细管的最小死体积连接方法.将紫外吸收检测的检测窗口设计在石英毛细管上,使该PMMA芯片上的电泳分析可以直接采用紫外吸收检测器进行检测.利用该芯片对维生素B2进行了电泳分析,理论塔板数为73000/m;联磺甲氧苄啶片中的3种组分的分离度为4.5和1.9,3个峰迁移时间的RSD依次为1.0%,1.4%和1.0%,峰高的RSD依次为4.1%,3.0%和4.1%(n=5).  相似文献   

7.
The fabrication and performance of a microfluidic device with integrated liquid-core optical waveguides for laser induced fluorescence DNA fragment analysis is presented. The device was fabricated through poly(dimethylsiloxane) (PDMS) soft lithography and waveguides are formed in dedicated channels through the addition of a liquid PDMS pre-polymer of higher refractive index. Once a master has been fabricated, microfluidic chips can be produced in less than 3 h without the requirement for a cleanroom, yet this method provides an optical system that has higher performance than a conventional confocal optical assembly. Optical coupling was achieved through the insertion of optical fibers into fiber-to-waveguide couplers at the edge of the chip and the liquid-fiber interface results in low reflection and scattering losses. Waveguide propagation losses are measured to be 1.8 dB cm(-1) (532 nm) and 1.0 dB cm(-1) (633 nm). The chip displays an average total coupling loss of 7.6 dB due to losses at the optical fiber interfaces. In the electrophoretic separation and detection of a BK virus PCR product, the waveguide system achieves an average signal-to-noise ratio of 570 +/- 30 whereas a commercial confocal benchtop electrophoresis system achieves an average SNR of 330 +/- 30. To our knowledge, this is the first time that a waveguide-based system has been demonstrated to have a SNR comparable to a commercially available confocal-based system for microchip capillary electrophoresis.  相似文献   

8.
Joule heating generated by the electrical current in capillary electrophoresis leads to a temperature gradient along the separation channel and consequently affects the separation quality. We describe a method of reducing the Joule heating effect by incorporating photonic crystal fiber into a micro capillary electrophoresis chip. The photonic crystal fiber consists of a bundle of extremely narrow hollow channels, which ideally work as separation columns. Electrophoretic separation of DNA fragments was simultaneously but independently carried out in 54 narrow capillaries with a diameter of 3.7 μm each. The capillary bundle offers more efficient heat dissipation owing to the high surface-to-volume ratio. Under the same electrical field strength, notable improvement in resolution was obtained in the capillary bundle chip.  相似文献   

9.
Feng J  Yang XJ  Li XC  Yang H  Chen ZG 《Analytical sciences》2011,27(10):1057-1060
An automated fluid-transport device for a chip-based capillary electrophoresis system has been developed. The device mainly consists of six peristaltic micropumps, two vacuum micropumps, microvalves, multi-way joints, titanium tubes, and a macro-to-micro connector. Various solutions used for the cleaning and activation of chip channels, and electrophoresis separation, are allowed to automatically transport to chip reservoirs by the electric control module. The performance of the whole system was characterized by the analysis of fluorescein sodium using chip electrophoresis with LED-induced fluorescence detection. The peak-height variation (RSD) was 3.8% in six cycles of analyses. Additionally, compared with conventional manual operation, the developed device can spare 60% time for chip pretreatment. This microdevice offers high-efficiency pretreatment for microchips, thereby resulting in a remarkable improvement of analytical capacity for batch samples.  相似文献   

10.
Z Zhou  K Wang  X Yang  S Huang  L Zhou  D Qin  L Du 《The Analyst》2001,126(11):1838-1840
A novel method for the synchronization of separation and determination is described, in which a mode-filtered light detector is used as an online detector in capillary electrophoresis. An instrument is described which has been developed for this purpose. The round capillary used in conventional capillary electrophoresis is replaced by an annular column, which is constructed from a naked optical fibre inserted into a fused-silica capillary. In fact, the annular electrophoresis column itself forms part of the mode-filtered light sensor. Along the side of the annular column are several detection channels for gathering and transmitting the mode-filtered light to a charge-coupled device (CCD). Every channel provides information on the sample from the point at which it is located. Using capillary isotachophoresis incorporating the annular column, the analytes in a sample containing alanine (10.0 mM) and glycine (9.7 mM) were simultaneously separated and determined using multichannel mode-filtered light detection with a detection limit of 1.5 mM.  相似文献   

11.
The research adopted a single-channel microchip as the probe, and focused electrokinetic injection combined with transient isotachophoresis preconcentration technique on capillary electrophoresis microchip to improve the analytical sensitivity of DNA fragments. The channel length, channel width and channel depth of the used microchip were 40.5 mm, and 110 and 50 μm, respectively. The separation was detected by CCD (charge-coupled device) (effective LENGTH=25 mm, 260 nm). A 1/100 diluted sample (0.2 mg/l of each DNA fragment) of commercially available stepladder DNA sample could be baseline separated in 120 s with S/N=2–5. Compared with conventional chip gel electrophoresis, the proposed method is ideally suited to improve the sensitivity of DNA analysis by chip electrophoresis.  相似文献   

12.
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 μm) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20–110 V in Vp–p) and frequency (40–65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 μmol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available.  相似文献   

13.
A microfluidic device is described in which an electrospray interface to a mass spectrometer is integrated with a capillary electrophoresis channel, an injector and a protein digestion bed on a monolithic substrate. A large channel, 800 microm wide, 150 microm deep and 15 mm long, was created to act as a reactor bed for trypsin immobilized on 40-60 microm diameter beads. Separation was performed in channels etched 10 microm deep, 30 microm wide and about 45 mm long, feeding into a capillary, attached to the chip with a low dead volume coupling, that was 30 mm in length, with a 50 microm i.d. and 180 microm o.d. Sample was pumped through the reactor bed at flow rates between 0.5 and 60 microL/min. The application of this device for rapid digestion, separation and identification of proteins is demonstrated for melittin, cytochrome c and bovine serum albumin (BSA). The rate and efficiency of digestion was related to the flow rate of the substrate solution through the reactor bed. A flow rate of 1 or 0.5 microL/min was found adequate for complete consumption of cytochrome c or BSA, corresponding to a digestion time of 3-6 min at room temperature. Coverage of the amino acid sequence ranged from 92% for cytochrome c to 71% for BSA, with some missed cleavages observed. Melittin was consumed within 5 s. In contrast, a similar extent of digestion of melittin in a cuvet took 10-15 min. The kinetic limitations associated with the rapid digestion of low picomole levels of substrate were minimized using an integrated digestion bed with hydrodynamic flow to provide an increased ratio of trypsin to sample. This chip design thus provides a convenient platform for automated sample processing in proteomics applications.  相似文献   

14.
毛细管电泳柱及微流控芯片通道涂层的发展   总被引:2,自引:0,他引:2  
刘春叶  陈杰瑢 《色谱》2005,23(1):63-68
综述了用于毛细管电泳柱和微流控芯片通道的涂层材料和涂层技术的发展状况,以及涂层对分离效果和分离结果重现性的影响。将涂层材料按照动态和静态分类,静态涂层又分别按照均聚物、共聚物、杂环类等进行讨论;综述了交联反应法、溶胶-凝胶法、辐照法、化学沉积法等涂层的制备方法。对毛细管电泳柱和微流控芯片通道的改良具有一定的参考价值。  相似文献   

15.
Among electrochemical detection methods in capillary electrophoresis, conductometric methods are of specific interest for the determination of inorganic species. This is due to the fact that inorganic ions exhibit a high equivalent conductivity which corresponds to the analytical signal in conductivity detection. Indirect optical absorption methods, which are widely used in capillary electrophoretic ion analyses, become less sensitive with smaller capillary dimensions and thus have disadvantages in electrokinetic chip separation technologies.Conductivity detection for capillary electrophoresis is performed either through galvanic contact or in a contactless mode. Techniques using a galvanic contact of the sample ions with the measuring electrode are performed either on-capillary without decoupling of the separation high voltage, or off-capillary after grounding the separation voltage in order to avoid interferences. This technology is specifically important when a suppressor is used prior to detection. Most contactless methods use oscillometric techniques in order to obtain the analytical signal.This review discusses the theoretical and instrumental background of conductivity detection in capillary electrophoresis and reports on recent aspects and applications using conductometric detection methods for capillary zone electrophoresis.  相似文献   

16.
集成毛细管电泳芯片系统的制作、测试及应用   总被引:7,自引:0,他引:7  
使用标准光刻和化学湿法腐蚀技术,在玻璃板材上制作了由样样管道和分离管道内构成的集成毛细管网路系统,对影响芯片质量的一些因素进行了讨论,并进行了性能测试和评价。芯片上毛细管道散热良好。使用激光诱导荧光和CCD成像检测系统,以电渗作用为驱动力,对混合样品进行了进样、快速分离(20s以内)和监测,证明了自制集成毛细管电泳芯片及检测系统的可行性。比较了两种注样方式(float和pinched)的不同;证明了在分离时可以优化加电策略,防止拖尾,改善峰形。  相似文献   

17.
Microfluidic chip electrophoresis has been widely employed for separation of various biochemical species owing to its advantages of low sample consumption, low cost, fast analysis, high throughput, and integration capability. In this article, we reviewed the development of four different modes of microfluidics‐based electrophoresis technologies including capillary electrophoresis, gel electrophoresis, dielectrophoresis, and field (electric) flow fractionation. Coupling detection schemes on microfluidic electrophoresis platform were also reviewed such as optical, electrochemical, and mass spectrometry method. We further discussed the innovative applications of microfluidic electrophoresis for biomacromolecules (nucleic acids and proteins), biochemical small molecules (amino acids, metabolites, ions, etc.), and bioparticles (cells and pathogens) analysis. The future direction of microfluidic chip electrophoresis was predicted.  相似文献   

18.
Vrouwe EX  Luttge R  van den Berg A 《Electrophoresis》2004,25(10-11):1660-1667
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.  相似文献   

19.
单细胞分析的研究   总被引:1,自引:0,他引:1  
程介克  黄卫华  王宗礼 《色谱》2007,25(1):1-10
单细胞分析是分析化学、生物学和医学之间渗透发展形成的跨学科前沿领域。近年来,毛细管电泳及微流控芯片用于单细胞分析已取得显著进展,特别表现在微流控芯片用于细胞的培养、分选、操纵、定位、分离及检测细胞的组分,实时监测细胞释放,及高通量阵列检测等方面。芯片的单元操作可根据需要灵活组合,显示出其独特的优点。本文重点介绍作者研究组的工作,并对近三年来国内外在毛细管电泳及芯片毛细管电泳用于单细胞分析的新进展进行评论。最后从毛细管电泳与微流控芯片、微流控芯片与细胞界面以及量子点用于探测活细胞等方面,展望了单细胞分析的发展前景。  相似文献   

20.
A sheathless and electrodeless nanospray interface has been used to interface a polycarbonate capillary electrophoresis (CE) chip to a mass spectrometer (MS). The chip was made of two flat polycarbonate plates which were bolted together. Channels were imprinted in one of the plates with metal wires, using a hydraulic press. A short tapered capillary connected to the chip was used as the nanospray emitter. The advantage of this electrodeless interface is that it was not necessary to apply a electrospray voltage to the chip or the nanospray emitter. Instead, the CE voltage already applied to the buffer compartment on the chip, to drive the electrophoresis, was used to generate the spray also. A low conductivity buffer of 1.25 mmol/L ammonium acetate in 80% methanol was used to obtain a large electric field across the buffer channel. The performance of the device was evaluated by analyzing a mixture of three beta-agonists Relative standard deviation (RSD) values obtained were between 4.8 and 5.0%. A sample concentration of 40 nmol/L resulted in a signal-to-noise ratio of 2 to 5 for the different components. Compared to a conventional CE analysis in a fused silica capillary with UV detection, only a minor loss of resolution was observed, which can be attributed to the design of the chip.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号