首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The number of particles in a sample heavily influences the shape of a distribution corresponding to the individual particle measurements. Selecting an adequate number of particles that prevents biases due to sample size is particularly difficult for complex biological systems in which statistical distributions are not normal. Quantile analysis is a powerful statistical technique that can rapidly compare differences between multiple distributions of individual particles. This report utilizes quantile analysis to show that the number of events detected affects the mobility distributions for rat liver and mouse liver mitochondria, sample individual particles, when analyzed via capillary electrophoresis with laser-induced fluorescence. When the mitochondrial sample is small (e.g. <78), there are not enough events to obtain statistically relevant mobility data. Adsorption to the capillary surface also significantly affects the mobility distribution at a small number of events in uncoated and dynamically coated capillaries. These adsorption effects can be overcome when the mitochondrial load on the capillary is sufficiently large (i.e. >609 and >1426 events for mouse liver on uncoated capillaries and rat liver on dynamically coated capillaries, respectively). It is anticipated that quantile analysis can be used to study other distributions of individual particles, such as nanoparticles, organelles, and biomolecules, and that distributions of these particles will also be dependent on sample size.  相似文献   

2.
A combined detection system involving simultaneous LIF and contacfless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conduetivity detector was used in C^4D. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably.  相似文献   

3.
Bulk studies are not suitable to describe and study cell-to-cell variation, which is of high importance in biological processes such as embryogenesis, tissue differentiation, and disease. Previously, capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was used to measure the properties of organelles isolated from millions of cells. As such, these bulk measurements reported average properties for the organelles of cell populations. Similar measurements for organelles released from single cells would be highly relevant to describe the subcellular variations among cells. Toward this goal, here we introduce an approach to analyze the mitochondria released from single mammalian cells. Osteosarcoma 143B cells are labeled with either the fluorescent mitochondrion-specific 10-N-nonyl acridine orange (NAO) or via expression of the fluorescent protein DsRed2. Subsequently, a single cell is introduced into the CE-LIF capillary where the organelles are released by a combined treatment of digitonin and trypsin. After this treatment, an electric field is applied and the released organelles electromigrate toward the LIF detector. From an electropherogram, the number of detected events per cell, their individual electrophoretic mobilities, and their individual fluorescence intensities are calculated. The results obtained from DsRed2 labeling, which is retained in intact mitochondria, and NAO labeling, which labels all mitochondria, are the basis for discussion of the strengths and limitations of this single-cell approach. Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users  相似文献   

4.
The features of analytical systems utilizing microfluidic devices, especially detection methods, are described. Electrochemical detection (EC), laser-induced fluorescence (LIF), mass spectrometry (MS), and chemical luminescence (CL) methods are covered. EC enables detection without labeling and has been used in recent years because of its low cost and sensitivity. LIF is the most generally used detection method in microchip separations. Use of LED as an excitation source for fluorescence measurement was also developed for the purpose of miniaturization of the entire system, including detection and separation. Although MS enables highly sensitive analysis, the interface between MS and micro channels is still under examination. This review with fifty-two references introduces interesting detection methods for microchip separations. Related separation methods using microfluidic devices are also discussed.  相似文献   

5.
The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.  相似文献   

6.
Lim TS  Davila A  Zand K  Wallace DC  Burke PJ 《Lab on a chip》2012,12(15):2719-2725
It has been reported that mitochondrial metabolic and biophysical parameters are associated with degenerative diseases and the aging process. To evaluate these biochemical parameters, current technology requires several hundred milligrams of isolated mitochondria for functional assays. Here, we demonstrate manufacturable wafer-scale mitochondrial functional assay lab-on-a-chip devices, which require mitochondrial protein quantities three orders of magnitude less than current assays, integrated onto 4' standard silicon wafer with new fabrication processes and materials. Membrane potential changes of isolated mitochondria from various well-established cell lines such as human HeLa cell line (Heb7A), human osteosarcoma cell line (143b) and mouse skeletal muscle tissue were investigated and compared. This second generation integrated lab-on-a-chip system developed here shows enhanced structural durability and reproducibility while increasing the sensitivity to changes in mitochondrial membrane potential by an order of magnitude as compared to first generation technologies. We envision this system to be a great candidate to substitute current mitochondrial assay systems.  相似文献   

7.
Unconventional detection methods for microfluidic devices   总被引:2,自引:0,他引:2  
The direction of modern analytical techniques is to push for lower detection limits, improved selectivity and sensitivity, faster analysis time, higher throughput, and more inexpensive analysis systems with ever-decreasing sample volumes. These very ambitious goals are exacerbated by the need to reduce the overall size of the device and the instrumentation - the quest for functional micrototal analysis systems epitomizes this. Microfluidic devices fabricated in glass, and more recently, in a variety of polymers, brings us a step closer to being able to achieve these stringent goals and to realize the economical fabrication of sophisticated instrumentation. However, this places a significant burden on the detection systems associated with microchip-based analysis systems. There is a need for a universal detector that can efficiently detect sample analytes in real time and with minimal sample manipulation steps, such as lengthy labeling protocols. This review highlights the advances in uncommon or less frequently used detection methods associated with microfluidic devices. As a result, the three most common methods - LIF, electrochemical, and mass spectrometric techniques - are omitted in order to focus on the more esoteric detection methods reported in the literature over the last 2 years.  相似文献   

8.
为了探究线粒体的能量代谢过程,本文以离体大鼠肝脏线粒体为模型,利用多通道、高灵敏度的热活性检测仪TAM Ⅲ,实时监测了不同线粒体浓度、不同底物、不同缓冲液、几种呼吸抑制剂以及Ca2+和线粒体渗透转换孔抑制剂CsA存在时线粒体的能量代谢,获得了完整的热功率―时间曲线,并通过计算得到了线粒体能量代谢的热动力学参数。通过分析发现:(1)线粒体浓度越大,代谢越快;(2)直接底物琥珀酸钠使线粒体代谢更快;(3)高浓度Ca2+能够刺激线粒体快速产热,且在长期代谢进程中,线粒体渗透转换孔抑制剂CsA并不能改变Ca2+造成的影响;(4)不同缓冲液对线粒体代谢的影响基于其组分的不同,缓冲液中含有呼吸底物;(5)呼吸抑制剂都能抑制线粒体的能量代谢,尤其是复合物IV的抑制剂NaN3,高浓度下使代谢停止。  相似文献   

9.
Fuller KM  Duffy CF  Arriaga EA 《Electrophoresis》2002,23(11):1571-1576
We report the application of capillary electrophoresis (CE) with postcolumn laser-induced fluorescence (LIF) detection to measure the cardiolipin content of individual mitochondria from cultured NS1 cells. Mitochondria were isolated by differential centrifugation and stained with the fluorescent dye 10-N-nonyl acridine orange which stoichiometrically binds to cardiolipin in a 1:1 or 2:1 ratio depending on the dye concentration. The green fluorescence resulting from the 1:1 complex was chosen for analysis because it is substantially more intense than the red fluorescence resulting from the 2:1 complex. Two dye concentrations that resulted in maximal and submaximal formation of the 1:1 10-N-nonyl acridine orange-cardiolipin complex were identified by spectrofluorometry. Individual mitochondria stained with both dye concentrations were separated and detected by CE with LIF detection. The data from mitochondria dosed with the lower dye concentration, where it is assumed that all the dye added to the mitochondrial sample was bound to cardiolipin, were used to derive a sensitivity factor relating fluorescence intensity of a mitochondrial event to its cardiolipin content. Using this factor, the cardiolipin contents of individual mitochondria stained with the higher dye concentration were determined, and ranged from 1.2 to 920 amol, with a median value of 4 amol. These results suggest a new strategy for estimating the organellar content of compounds that can be fluorescently tagged.  相似文献   

10.
Li HF  Lin JM  Su RG  Cai ZW  Uchiyama K 《Electrophoresis》2005,26(9):1825-1833
A protocol of producing multiple polymeric masters from an original glass master mold has been developed, which enables the production of multiple poly(dimethylsiloxane) (PDMS)-based microfluidic devices in a low-cost and efficient manner. Standard wet-etching techniques were used to fabricate an original glass master with negative features, from which more than 50 polymethylmethacrylate (PMMA) positive replica masters were rapidly created using the thermal printing technique. The time to replicate each PMMA master was as short as 20 min. The PMMA replica masters have excellent structural features and could be used to cast PDMS devices for many times. An integration geometry designed for laser-induced fluorescence (LIF) detection, which contains normal deep microfluidic channels and a much deeper optical fiber channel, was successfully transferred into PDMS devices. The positive relief on seven PMMA replica masters is replicated with regard to the negative original glass master, with a depth average variation of 0.89% for 26-microm deep microfluidic channels and 1.16% for the 90 mum deep fiber channel. The imprinted positive relief in PMMA from master-to-master is reproducible with relative standard deviations (RSDs) of 1.06% for the maximum width and 0.46% for depth in terms of the separation channel. The PDMS devices fabricated from the PMMA replica masters were characterized and applied to the separation of a fluorescein isothiocyanate (FITC)-labeled epinephrine sample.  相似文献   

11.
This paper describes a simple plasma-based dry etching method that enables patterned cell culture inside microfluidic devices by allowing patterning, fluidic bonding and sterilization steps to be carried out in a single step. This plasma-based dry etching method was used to pattern cell-adhesive and non-adhesive areas on the glass and polystyrene substrates. The patterned substrate was used for selective attachment and growth of human umbilical vein endothelial cells, MDA-MB-231 human breast cancer cells, NIH 3T3 mouse fibroblasts, and primary rat cortical neurons. Finally, we have successfully combined the dry-patterned substrate with a microfluidic device. Patterned primary rat neurons were maintained for up to 6 days inside the microfluidic devices and the neurons' somas and processes were confined to the cell-adhesive region. The method developed in this work offers a convenient way of micropatterning biomaterials for selective attachment of cells on the substrates, and enables culturing of patterned cells inside microfluidic devices for a number of biological research applications where cells need to be exposed to well-controlled fluidic microenvironment.  相似文献   

12.
A method for the determination of carnitine palmitoyltransferase I (CPT I; EC 2.3.1.19) in isolated rat liver mitochondria by reversed-phase high-performance liquid chromatography is described. Enzyme activity is assayed by direct determination of coenzyme A (CoA) released from palmitoyl-CoA within 60 min by a linear gradient system. CPT 1 in rat liver mitochondria can be assayed from only 30 micrograms of mitochondrial protein per millilitre of assay mixture. The changes in the kinetic parameters of CPT I, including Ki for malonyl-CoA, resulting from the fasting-feeding cycle are also discussed.  相似文献   

13.
Whiting CE  Arriaga EA 《Electrophoresis》2006,27(22):4523-4531
This report is the first demonstration of the use of uncoated and dynamically coated capillaries for the separation of individual mitochondria via CE. Currently, the analysis of individual mitochondria relies upon fused-silica capillaries coated with a hydrophilic polymer (e.g. poly(acryloylaminopropanol)), which is used to minimize adsorption to the capillary surface. Both uncoated fused-silica capillaries and 0.2% w/w poly(vinyl alcohol) dynamic coating solutions are used to successfully analyze isolated individual mitochondrial particles using CE-LIF. While it was possible to separate mouse liver mitochondria on an uncoated capillary, rat liver mitochondria proved to have strong adsorption characteristics that only allowed them to be adequately separated with a PVA dynamic coating or a poly(acryloylaminopropanol) (AAP) capillary. The possible causes for this adsorption are analyzed and discussed. This study shows that uncoated and dynamically coated capillaries can be used in place of AAP-coated capillaries to analyze mitochondria and suggests the use of these capillaries for the analysis of other organelles, offering a greatly simplified method for the analysis of individual organelles.  相似文献   

14.
Free radical polymerization in microfluidic devices modeled with the help of numerical simulations is discussed. The simulation method used allows the simultaneous solvation of partial differential equations resulting from the hydrodynamics, thermal and mass transfer (convection, diffusion and chemical reaction). Three microfluidic devices are modeled, two interdigital multilamination micromixers respectively with a large and short focusing section, and a simple T-junction followed by a microtube reactor together considered as a bilamination micromixer with a large focusing section. The simulations show that in spite of the heat released by the polymerization reaction, the thermal transfer in such microfluidic devices is high enough to ensure isothermal conditions. Moreover, for low radial Peclet number, microfluidic devices with a large focusing section can achieve better control over the polymerization than a laboratory scale reactor as the polydispersity index obtained is very close to the theoretical limiting value. As the characteristic dimension of the microfluidic device increases, i.e. for high radial Peclet number, the reactive medium cannot be fully homogenized by the diffusion transport before leaving the system resulting in a high polydispersity index and a loss in the control of the polymerization.  相似文献   

15.
The proper functioning of mitochondria requires that both the mitochondrial and the nuclear genome are functional. To investigate the importance of the mitochondrial genome, which encodes only 13 subunits of the respiratory complexes, the mitochondrial rRNAs and a few tRNAs, we performed a comparative study on the 143B cell line and on its Rho-0 counterpart, i.e., devoid of mitochondrial DNA. Quantitative differences were found, of course in the respiratory complexes subunits, but also in the mitochondrial translation apparatus, mainly mitochondrial ribosomal proteins, and in the ion and protein import system, i.e., including membrane proteins. Various mitochondrial metabolic processes were also altered, especially electron transfer proteins and some dehydrogenases, but quite often on a few proteins for each pathway. This study also showed variations in some hypothetical or poorly characterized proteins, suggesting a mitochondrial localization for these proteins. Examples include a stomatin-like protein and a protein sharing homologies with bacterial proteins implicated in tyrosine catabolism. Proteins involved in apoptosis control are also found modulated in Rho-0 mitochondria.  相似文献   

16.
The mitochondrial membrane potential (DeltaPsi(m)) is an important indicator of the energetic state of both the mitochondria and the cells. To develop a sensitive, convenient, and rapid method for the measurement of DeltaPsi(m), we carried out cell fluorescence assays using the Agilent 2100 bioanalyzer system which, unlike the conventional flow cytometry, is based on microfluidic technology employing fluorescence detection with a 3,3'-dihexyloxacarbocyanine iodide (DiOC(6)(3)) fluorescent probe. The use of DiOC(6)(3) in the fluorometer was shown to be feasible for monitoring variations in DeltaPsi(m) in the mitochondria isolated from rat liver and treated with rotenone, succinate, ADP, and carbonylcyanide-p-trifluoromethoxyphenylhydrazone (FCCP). Flow cytometry analysis showed severe reduction of fluorescence intensity in Jurkat cells after treatment with 1.0 and 10 microM FCCP. However, fluorescence microscopy demonstrated obvious accumulation of fluorescence in the mitochondria and induction of diffuse cytoplasmic fluorescence not localized to the mitochondria in these cells. The dose response range of DiOC(6)(3) in the Agilent 2100 bioanalyzer system for yielding sufficient fluorescence intensity in the mitochondria of the cells was 20 nm-2.0 microM. Furthermore, significant reduction of fluorescence intensity in the cells stained with 2.0 microM DiOC(6)(3) was observed after treatment with 10 microM FCCP for 30 min. These results indicate that the Agilent 2100 bioanalyzer is potentially useful for monitoring DeltaPsi(m) in cell assays.  相似文献   

17.
Ion mobility spectrometry (IMS) has potential analytical applications in very diverse fields such as chemical, petrochemical, environmental, and, more recently, in drug, chemical warfare agent, and explosives detection. Commercially available IMS instruments are based on time-of-flight (TOF) mass spectrometry. IMS is inherently suitable for field operation as it uses relatively simple microfluidic devices and operates at atmospheric pressure. It is portable, highly sensitive with tunable selectivity, yet can be produced at relatively low cost. Key limitations of this analytical detection technique are low duty cycle, ion cluster formation, short linear dynamic range, and restriction to only positive or negative ion collection in a single analysis. Microelectromechanical system, radio frequency modulated IMS (MEMS RF-IMS), also known as differential mobility spectrometry, has recently been developed and commercialized. The technology is based on IMS, and MEMS RF-IMS offers substantially better performance. In this study, the strengths and limitations of the recently introduced differential mobility detector when used with gas chromatography in trace analyses are discussed and illustrated with applications of industrial significance.  相似文献   

18.
19.
AC electrokinetics is a generic term that refers to an induced motion of particles and fluids under nonuniform AC electric fields. The AC electric fields are formed by application of AC voltages to microelectrodes, which can be easily integrated into microfluidic devices by standard microfabrication techniques. Moreover, the magnitude of the motion is large enough to control the mass transfer on the devices. These advantages are attractive for biomolecular analysis on the microfluidic devices, in which the characteristics of small space and microfluidics have been mainly employed. In this review, I describe recent applications of AC electrokinetics in biomolecular analysis on microfluidic devices. The applications include fluid pumping and mixing by AC electrokinetic flow, and manipulation of biomolecules such as DNA and proteins by various AC electrokinetic techniques. Future prospects for highly functional biomolecular analysis on microfluidic devices with the aid of AC electrokinetics are also discussed.  相似文献   

20.
Flow cytometry (FCM) and more recently capillary electrophoresis with post-column laser-induced fluorescence detection (CE-LIF) have both been used for subcellular particle analysis but their analytical performance has not been compared. In this work, we compare a commercial FCM with an in-house built CE-LIF instrument using fluorescently labeled microspheres and isolated mitochondria. As evidenced by the relative standard deviation (RSD) of the individual fluorescence intensities, FCM is two-fold better than CE-LIF for microspheres with > or =1.5 x 10(6) molecules of equivalent soluble fluorescein (MESF). However, FCM has a comparatively low signal-to-noise ratio (S/N) and high RSD for microspheres with <1.5 x 10(6) MESF. CE-LIF, on the other hand, produces S/N ratios that are >25 times higher than FCM for all the microspheres tested and a lower RSD for microspheres with <1.5 x 10(6) MESF. When 10-N-nonyl acridine orange (NAO)-labeled mitochondria are analyzed, the S/N ratios of both techniques are similar. This appears to result from photobleaching of NAO-labeled mitochondria as they are detected by the LIF detector of the CE-LIF instrument. Both techniques have a niche in subcellular analysis; FCM has the advantage of collecting data for thousands of particles quickly, whereas CE-LIF consumes less than a nanoliter of sample and provides the electrophoretic mobility for individual particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号