首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
C Kim  JH Bang  YE Kim  SH Lee  JY Kang 《Lab on a chip》2012,12(20):4135-4142
This paper proposes a new cytotoxicity assay in a microfluidic device with microwells and a distributive microfluidic channel network for the formation of cancer cell spheroids. The assay can generate rapid and uniform cell clusters in microwells and test in situ cytotoxicity of anticancer drugs including sequential drug treatments, long term culture of spheroids and cell viability assays. Inlet ports are connected to the microwells by a hydraulic resistance network. This uniform distribution of cell suspensions results in regular spheroid dimensions. Injected cancer cells were trapped in microwells, and aggregated into tumor spheroids within 3 days. A cytotoxicity test of the spheroids in microwells was subsequently processed in the same device without the extraction of cells. The in situ cytotoxicity assay of tumor spheroids in microwells was comparable with the MTT assay on hanging drop spheroids using a conventional 96-well plate. It was observed that the inhibition rate of the spheroids was less than that in the 2D culture dish and the effect on tumor spheroids was different depending on the anticancer drug. This device could provide a convenient in situ assay tool to assess the cytotoxicity of anticancer drugs on tumor spheroids, offering more information than the conventional 2D culture plate.  相似文献   

2.
Integrating 2D culture of adherent mammalian cells with single‐cell western blotting (in situ scWB) uses microfluidic design to eliminate the requirement for trypsin release of cells to suspension, prior to single‐cell isolation and protein analysis. To assay HeLa cells from an attached starting state, we culture adherent cells in fibronectin‐functionalized microwells formed in a thin layer of polyacrylamide gel. To integrate the culture, lysis, and assay workflow, we introduce a one‐step copolymerization process that creates protein‐decorated microwells. After single‐cell culture, we lyse each cell in the microwell and perform western blotting on each resultant lysate. We observe cell spreading after overnight microwell‐based culture. scWB reports increased phosphorylation of MAP kinases (ERK1/2, p38) under hypertonic conditions. We validate the in situ scWB with slab‐gel western blot, while revealing cell‐to‐cell heterogeneity in stress responses.  相似文献   

3.
Directed differentiation of embryonic stem (ES) cells is useful for creating models of human disease and could potentially generate a wide array of functional cell types for therapeutic applications. Methods to differentiate ES cells often involve the formation of cell aggregates called embryoid bodies (EBs), which recapitulate early stages of embryonic development. EBs are typically made from suspension cultures, resulting in heterogeneous structures with a wide range of sizes and shapes, which may influence differentiation. Here, we use microfabricated cell-repellant poly(ethylene glycol) (PEG) wells as templates to initiate the formation of homogenous EBs. ES cell aggregates were formed with controlled sizes and shapes defined by the geometry of the microwells. EBs generated in this manner remained viable and maintained their size and shape within the microwells relative to their suspension counterparts. Intact EBs could be easily retrieved from the microwells with high viability (>95%). These results suggest that the microwell technique could be a useful approach for in vitro studies involving ES cells and, more specifically, for initiating the differentiation of EBs of greater uniformity based on controlled microenvironments.  相似文献   

4.
The ability to control the deposition and location of adherent and non-adherent cells within microfluidic devices is beneficial for the development of micro-scale bioanalytical tools and high-throughput screening systems. Here, we introduce a simple technique to fabricate poly(ethylene glycol)(PEG) microstructures within microfluidic channels that can be used to dock cells within pre-defined locations. Microstructures of various shapes were used to capture and shear-protect cells despite medium flow in the channel. Using this approach, PEG microwells were fabricated either with exposed or non-exposed substrates. Proteins and cells adhered within microwells with exposed substrates, while non-exposed substrates prevented protein and cell adhesion (although the cells were captured inside the features). Furthermore, immobilized cells remained viable and were stained for cell surface receptors by sequential flow of antibodies and secondary fluorescent probes. With its unique strengths in utility and control, this approach is potentially beneficial for the development of cell-based analytical devices and microreactors that enable the capture and real-time analysis of cells within microchannels, irrespective of cell anchorage properties.  相似文献   

5.
Sinkala E  Eddington DT 《Lab on a chip》2010,10(23):3291-3295
Oxygen tension is critical in a number of cell pathways but is often overlooked in cell culture. One reason for this is the difficulty in modulating and assessing oxygen tensions without disturbing the culture conditions. Toward this end, a simple method to generate oxygen-sensitive microwells was developed through embossing polystyrene (PS) and platinum(ii) octaethylporphyrin ketone (PtOEPK) thin films. In addition to monitoring the oxygen tension, microwells were employed in order to isolate uniform clusters of cells in microwells. The depth and width of the microwells can be adapted to different experimental parameters easily by altering the thin film processing or embossing stamp geometries. The thin oxygen sensitive microwell substrate is also compatible with high magnification modalities such as confocal imaging. The incorporation of the oxygen sensor into the microwells produces measurements of the oxygen tension near the cell surface. The oxygen sensitive microwells were calibrated and used to monitor oxygen tensions of Madin-Darby Canine Kidney Cells (MDCKs) cultured at high and low densities as a proof of concept. Wells 500 μm in diameter seeded with an average of 330 cells exhibited an oxygen level of 12.6% whereas wells seeded with an average of 20 cells per well exhibited an oxygen level of 19.5%, a 35.7% difference. This platform represents a new tool for culturing cells in microwells in a format amenable to high magnification imaging while monitoring the oxygen state of the culture media.  相似文献   

6.
The fabrication of 3D cell microenvironments exploiting versatile, long‐term stable passivating poly(acryl amide) brushes in a microwell format and the study of the behavior of fibroblast and pancreatic tumor cells in wells of systematically varied shape and size is reported. The microwells, which are obtained by combining micromolding in capillaries with microcontact printing of initiator monolayers for subsequent surface‐initiated polymerization of acrylamide and controlled functionalization with fibronectin (FN), expose cell adhesive areas inside the wells and protein and cell resistant brushes on the topside plateaus. NIH 3T3 fibroblast and pancreatic tumor (Patu 8988T) cells adhere and remain viable in the FN coated microwells for more than 1 week. Compared to 2D patterns, both cell lines are observed to attach to the bottom as well as the sidewalls of the microwells. The cytoskeleton alignment is found to be less pronounced compared to 2D patterned substrates, independent of microwell size and geometry.

  相似文献   


7.
Organizing leukocytes into high-density arrays makes these cells amenable to rapid optical characterization and subsequent sorting, pointing to clinical and basic science applications. The present paper describes development of a cytometry platform for creating high-density leukocyte arrays and demonstrates retrieval of single cells from the array. Poly(ethylene glycol)(PEG) photolithography was employed to fabricate arrays of microwells composed of PEG hydrogel walls and glass attachment pads 20 microm x 20 microm and 15 microm x 15 microm in size. PEG micropatterned glass surfaces were further modified with cell-adhesive ligands, poly-L-lysine, anti-CD5 and anti-CD19 antibodies, in order to engineer specific cell-surface interactions within the individual wells. Localization of the fluorescently-labeled proteins in the glass attachment pads of PEG microwells was visualized by fluorescence microscopy. Glass slides micropatterned with PEG and cell-adhesive ligands were exposed to T-lymphocytes for 30 min. These anchorage-independent cells became selectively captured in the ligand-modified microwells forming high-density cell arrays. Cell occupancy in the microwells was found to be antibody-dependent, reaching 94.6 +/- 2.3% for microwells decorated with T-cell specific anti-CD5 antibodies. Laser capture microdissection (LCM) was investigated as a method for sorting cells from the array and retrieval of single selected cells was demonstrated.  相似文献   

8.
In order to better understand cellular processes and behavior, a controlled way of studying high numbers of single cells and their clone formation is greatly needed. Numerous ways of ordering single cells into arrays have previously been described, but platforms in which each cell/clone can be addressed to an exact position in the microplate, cultivated for weeks and treated separately in a high-throughput manner have until now been missing. Here, a novel microplate developed for high-throughput single cell/clone cultivation and analysis is presented. Rapid single cell seeding into microwells, using conventional flow cytometry, allows several thousands of single cells to be cultivated, short-term (72 h) or long-term (10-14 days), and analyzed individually. By controlled sorting of individual cells to predefined locations in the microplate, analysis of single cell heterogeneity and clonogenic properties related to drug sensitivity can be accomplished. Additionally, the platform requires remarkably low number of cells, a major advantage when screening limited amounts of patient cell samples. By seeding single cells into the microplate it is possible to analyze the cells for over 14 generations, ending up with more than 10 000 cells in each well. Described here is a proof-of-concept on compartmentalization and cultivation of thousands of individual cells enabling heterogeneity analysis of various cells/clones and their response to different drugs.  相似文献   

9.
集成药物代谢微流控芯片的研制   总被引:1,自引:1,他引:0  
本文研制了一种集成药物代谢微流控芯片, 此芯片可以同时完成药物代谢物的分子检测和代谢过程对药物细胞毒性的影响评价, 为进一步的药物代谢和药物相互作用研究奠定了良好的基础.  相似文献   

10.
Lateral mobility and dimensionality have both been shown to influence cellular behavior, but have yet to be combined and applied in a single in vitro platform to address, e.g., cell adhesion in a setting mimicking the three-dimensional environment of neighboring cells in a reductionist way. To study the effect of the lateral mobility of cell adhesive ligands in three dimensions we present and characterize a platform, which enables patterning of single cells into microwells presenting a cell membrane mimetic interface pre-patterned to its walls. Soluble E-cadherin extracellular domains coupled through an optimized streptavidin-antibody linkage to lipids in a supported lipid bilayer (SPB) were presented on the microwell walls as either laterally mobile or immobile ligands. The fluidity was controlled through a small change in temperature by choosing phospholipids for the SPB with a lipid phase transition temperature around 30 °C. The platform thus enabled the investigation of cell adhesion to either laterally immobile or mobile E-cadherin ligands presented on the same cell membrane mimetic surface. Chinese hamster ovary (CHO) cells engineered to express E-cadherin that were cultured on the platform demonstrated that enhanced cadherin lateral mobility significantly decreased the formation of actin bundles and resulted in more diffuse actin organization, while constraining the cell shape to that of the microwell. This example highlights the potential to use in vitro cell culture platforms to mimic direct cell-cell interaction in a controlled environment that nevertheless captures the dynamic nature of the native cell environment.  相似文献   

11.
Over the past few years there has been a great deal of interest in reducing experimental systems to a lab-on-a-chip scale. There has been particular interest in conducting high-throughput screening studies using microscale devices, for example in stem cell research. Microwells have emerged as the structure of choice for such tests. Most manufacturing approaches for microwell fabrication are based on photolithography, soft lithography, and etching. However, some of these approaches require extensive equipment, lengthy fabrication process, and modifications to the existing microwell patterns are costly. Here we show a convenient, fast, and low-cost method for fabricating microwells for cell culture applications by laser ablation of a polyester film coated with silicone glue. Microwell diameter was controlled by adjusting the laser power and speed, and the well depth by stacking several layers of film. By using this setup, a device containing hundreds of microwells can be fabricated in a few minutes to analyze cell behavior. Murine embryonic stem cells and human hepatoblastoma cells were seeded in polyester microwells of different sizes and showed that after 9 days in culture cell aggregates were formed without a noticeable deleterious effect of the polyester film and glue. These results show that the polyester microwell platform may be useful for cell culture applications. The ease of fabrication adds to the appeal of this device as minimal technological skill and equipment is required.  相似文献   

12.
Microwell structures were fabricated using SU-8 photoresist for engineering a quasi-three-dimensional (quasi-3D) microenvironment for cultured neuronal cells. SH-SY5Y human neuroblastoma cells were successfully integrated into microwells of a nominal diameter of 100 microm, with or without 10-microm wide microchannels connecting neighboring microwells, in an aspect ratio (ratio of structure depth over width) of approximately 1. With the help of polyethylene glycol stamping and laminin coating, a neuronal-like network was achieved by integrating populations of SH-SY5Y cells with a microwell network pattern. Resting membrane potential establishment was evaluated with confocal microscopy and the potentiometric fluorescent dye tetramethylrhodamine methyl ester. It was found that the intra/extracellular fluorescent intensity ratio (R) was 2.4+/-1.4 [n (number of cells measured)=112] for SH-SY5Y cells on flat SU-8 substrates on day 5 into differentiation, which was not significantly different from the ratio on day 13 into differentiation, 2.0+/-1.8 (n=104) (P>0.05). For cells in the microwell network structures, R was 4.8+/-4.7 (n=51) and 3.9+/-3.2 (n=62) on days 5 and 13 into differentiation, respectively (P>0.5). Cells within the network structures had higher R ratios than on flat substrates, for either day 5 or 13 into differentiation (P<0.01). These results demonstrated that the well network structures, or topographically patterned substrates, were more suitable formats for promoting SH-SY5Y cell resting membrane potential establishment than flat substrates, suggesting the potential to control cellular function through substrate topography engineering.  相似文献   

13.
14.
Microcarrier‐based stem cell expansion cultures can increase the dimensions of in vitro stem cell cultures from 2D to 3D. The culture handling process then becomes more efficient compared with conventional 2D cultures. However, the use of spherical plastic microcarriers complicates the monitoring of cell culture. To facilitate monitoring, transparent disc‐shaped microcarriers are manufactured using a light‐initiated microfluidic printing system and the obtained microcarriers are named as 2.5D microcarrier. The 2.5D microcarriers (diameter/height ≈ 5) enable us to use conventional monitoring tools in 2D‐based platform during the in vitro expansion on a 3D culture platform. Surface modification via a 1 h‐long poly‐dopamine (PDA) reaction can maintain the transparent nature of the microcarriers while optimizing the cell attachment. The surface marker expression and differentiation potential of the 2.5D microcarrier‐expanded stem cells reveal that the characteristics and functionalities preserved during expansion. The 2.5D microcarrier is readily integrated into an on‐bead assay to conserve reagents and permit a high number (n = 9) of repeated measurements with reliable results. These results demonstrate that the 2.5D microcarrier‐based scale‐up culture provides a valuable tool for the in vitro expansion of adherent stem cells, especially if repetitive monitoring is required.  相似文献   

15.
In this paper we demonstrate a facile and efficient way to fabricate poly(dimethylsiloxane) (PDMS) molds with hexagonal non-close-packed (ncp) arrangements of microwells by casting PDMS prepolymer onto two-dimensional (2D) ncp colloidal crystals. The templates of the 2D ncp colloidal crystals were fabricated via coupling lift-up soft lithography and solvent-swelling. We found that the depths of the microwells together with the lattice spacing can be adjusted by the sphere interstices and chemical composition of the 2D ncp colloidal crystals. The relationship of the surface character of the templates with the depths of the microwells can be explained by the wetting behavior of PDMS prepolymer on the rough surface. Contact angle measurements are consistent with the experimental results of the microwells in depth and agree well with the Cassie-Baxter theory. There are at least three advantages of the approach. First, the depth and distance of the microwells can be controlled. Second, PDMS molds can be easily peeled from the surfaces of the templates, which results in reusing the original templates to make new molds. Third, this method can be applied to other materials, such as photopolymerizable resin or thermosetting resin. The potential application of the microwells is as microlenses to make a pattern or as microvials in bioanalytical techniques.  相似文献   

16.
A common method of three-dimensional (3D) cell cultures is embedding single cells in Matrigel. Separated cells in Matrigel migrate or grow to form spheroids but lack cell-to-cell interaction, which causes difficulty or delay in forming mature spheroids. To address this issue, we proposed a 3D aggregated spheroid model (ASM) to create large single spheroids by aggregating cells in Matrigel attached to the surface of 96-pillar plates. Before gelling the Matrigel, we placed the pillar inserts into blank wells where gravity allowed the cells to gather at the curved end. In a drug screening assay, the ASM with Hepatocellular carcinoma (HCC) cell lines showed higher drug resistance compared to both a conventional spheroid model (CSM) and a two-dimensional (2D) cell culture model. With protein expression, cytokine activation, and penetration analysis, the ASM showed higher expression of cancer markers associated with proliferation (p-AKT, p-Erk), tight junction formation (Fibronectin, ZO-1, Occludin), and epithelial cell identity (E-cadherin) in HCC cells. Furthermore, cytokine factors were increased, which were associated with immune cell recruitment/activation (MIF-3α), extracellular matrix regulation (TIMP-2), cancer interaction (IL-8, TGF-β2), and angiogenesis regulation (VEGF-A). Compared to CSM, the ASM also showed limited drug penetration in doxorubicin, which appears in tissues in vivo. Thus, the proposed ASM better recapitulated the tumor microenvironment and can provide for more instructive data during in vitro drug screening assays of tumor cells and improved prediction of efficacious drugs in HCC patients.  相似文献   

17.
Progress in prostate cancer research is presently limited by a shortage of reliable in vitro model systems. The authors describe a novel self‐assembling peptide, bQ13, which forms nanofibers and gels useful for the 3D culture of prostate cancer spheroids, with improved cytocompatibility compared to related fibrillizing peptides. The mechanical properties of bQ13 gels can be controlled by adjusting peptide concentration, with storage moduli ranging between 1 and 10 kPa. bQ13's ability to remain soluble at mildly basic pH considerably improved the viability of encapsulated cells compared to other self‐assembling nanofiber‐forming peptides. LNCaP cells formed spheroids in bQ13 gels with similar morphologies and sizes to those formed in Matrigel or RADA16‐I. Moreover, prostate‐specific antigen (PSA) is produced by LNCaP cells in all matrices, and PSA production is more responsive to enzalutamide treatment in bQ13 gels than in other fibrillized peptide gels. bQ13 represents an attractive platform for further tailoring within 3D cell culture systems.  相似文献   

18.
3D constructs are fundamental in tissue engineering and cancer modeling, generating a demand for tailored materials creating a suitable cell culture microenvironment and amenable to be bioprinted. Gelatin methacrylate (GelMA) is a well-known functionalized natural polymer with good printability and binding motifs allowing cell adhesion; however, its tight micropores induce encapsulated cells to retain a non-physiological spherical shape. To overcome this problem, blended GelMa is here blended with Pluronic F-127 (PLU) to modify the hydrogel internal porosity by inducing the formation of larger mesoscale pores. The change in porosity also leads to increased swelling and a slight decrease in Young's modulus. All blends form stable hydrogels both when cast in annular molds and bioprinted in complex structures. Embedded cells maintain high viability, and while Neuroblastoma cancer cells typically aggregate inside the mesoscale pores, Mesenchymal Stem Cells stretch in all three dimensions, forming cell–cell and cell–ECM interactions. The results of this work prove that the combination of tailored porous materials with bioprinting techniques enables to control both the micro and macro architecture of cell-laden constructs, a fundamental aspect for the development of clinically relevant in vitro constructs.  相似文献   

19.
Dynamic single cell culture array   总被引:2,自引:0,他引:2  
Di Carlo D  Wu LY  Lee LP 《Lab on a chip》2006,6(11):1445-1449
It is important to quantify the distribution of behavior amongst a population of individual cells to reach a more complete quantitative understanding of cellular processes. Improved high-throughput analysis of single cell behavior requires uniform conditions for individual cells with controllable cell-cell interactions, including diffusible and contact elements. Uniform cell arrays for static culture of adherent cells have previously been constructed using protein micropatterning techniques but lack the ability to control diffusible secretions. Here we present a microfluidic-based dynamic single cell culture array that allows both arrayed culture of individual adherent cells and dynamic control of fluid perfusion with uniform environments for individual cells. In our device no surface modification is required and cell loading is done in less than 30 seconds. The device consists of arrays of physical U-shaped hydrodynamic trapping structures with geometries that are biased to trap only single cells. HeLa cells were shown to adhere at a similar rate in the trapping array as on a control glass substrate. Additionally, rates of cell death and division were comparable to the control experiment. Approximately 100 individual isolated cells were observed growing and adhering in a field of view spanning approximately 1 mm(2) with greater than 85% of cells maintained within the primary trapping site after 24 hours. Also, greater than 90% of cells were adherent and only 5% had undergone apoptosis after 24 hours of perfusion culture within the trapping array. We anticipate uses in single cell analysis of drug toxicity with physiologically relevant perfused dosages as well as investigation of cell signaling pathways and systems biology.  相似文献   

20.
Hydrogel precursors that crosslink within minutes are essential for the development of cell encapsulation matrices and their implementation in automated systems. Such timescales allow sufficient mixing of cells and hydrogel precursors under low shear forces and the achievement of homogeneous networks and cell distributions in the 3D cell culture. The previous work showed that the thiol-tetrazole methylsulfone (TzMS) reaction crosslinks star-poly(ethylene glycol) (PEG) hydrogels within minutes at around physiological pH and can be accelerated or slowed down with small pH changes. The resulting hydrogels are cytocompatible and stable in cell culture conditions. Here, the gelation kinetics and mechanical properties of PEG-based hydrogels formed by thiol-TzMS crosslinking as a function of buffer, crosslinker structure and degree of TzMS functionality are reported. Crosslinkers of different architecture, length and chemical nature (PEG versus peptide) are tested, and degree of TzMS functionality is modified by inclusion of RGD cell-adhesive ligand, all at concentration ranges typically used in cell culture. These studies corroborate that thiol/PEG-4TzMS hydrogels show gelation times and stiffnesses that are suitable for 3D cell encapsulation and tunable through changes in hydrogel composition. The results of this study guide formulation of encapsulating hydrogels for manual and automated 3D cell culture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号