首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A rapid procedure for the evaluation of codeine phosphate drug substance derived from poppy straw or opium concentrate is described. The gradient HPLC procedure employs a pH 2.5 phosphate buffer, methanol and acetonitrile mobile phase at 40°C and a Bondapak C-18 column. Eight opium alkaloids, including the four major alkaloids, are separated from each other. The paper describes details of the assay procedure and presents data documenting the linearity, specificity, precision, and sensitivity of the method.  相似文献   

2.
A new concept in high-performance liquid chromatography supports is proposed for the direct injection analysis of drug enantiomers in plasma. The new supports are designed with disuccinimidyl suberate as a hydrophobic internal region, and avidin protein as a hydrophilic and bulky surface region. Plasma proteins are excluded by the avidin phase and are eluted immediately from the column, whereas low-molecular-mass analytes can penetrate the surface region and interact with disuccinimidyl suberate. Enantiomers interact differentially with avidin, and are thereby separated. This column was used in reversed-phase high-performance liquid chromatographic analysis to determine ketoprofen enantiomers in plasma by direct injection. The recovery of racemic drug from plasma was almost 100%.  相似文献   

3.
Summary The resolution of the enantiomers of new acetylcholinesterase inhibitors by high-performance liquid chromatography (HPLC) was investigated on stationary phases containing cellulose tris-(3,5 methylphenylcarbamide) (Chiralcel OD). The effects of the mobile phase on retention, enantioselectivity and resolution were also studied. Ethanol and isopropanol were tested as organic modifiers and the influence of diethylamine was investigated. The effect of temperature on chiral separations was also studieded.  相似文献   

4.
5.
Careful selection of both high-pH mobile phase as well as organic modifier, was performed in order to develop and optimize HPLC conditions for the separation of drug discovery compounds. High-pH mobile phases provide excellent chromatographic resolution and increased mass loading of basic compounds. The analytical methods so defined have been successfully transferred to preparative automated UV-directed purification, an important fact due to the increasing number of samples requiring purification. It should be noted that, the single prerequisite for this approach is an analytical LC-UV-MS run, therefore the system has the ability to collect only fractions likely to contain the target product. A cost-effective strategy for maximizing the purification of drug discovery compounds is proposed.  相似文献   

6.
Methods for the enantiomeric quantitative determination of 3 chiral pesticides, paclobutrazol, myclobutanil, and uniconazole, and their residues in soil and water are reported. An effective chiral high-performance liquid chromatographic (HPLC)-UV method using an amylose-tris(3,5-dimethylphenylcarbamate; AD) column was developed for resolving the enantiomers and quantitative determination. The enantiomers were identified by a circular dichroism detector. Validation involved complete resolution of each of the 2 enantiomers, plus determination of linearity, precision, and limit of detection (LOD). The pesticide enantiomers were isolated by solvent extraction from soil and C18 solid-phase extraction from water. The 2 enantiomers of the 3 pesticides could be completely separated on the AD column using n-hexane isopropanol mobile phase. The linearity and precision results indicated that the method was reliable for the quantitative analysis of the enantiomers. LODs were 0.025, 0.05, and 0.05 mg/kg for each enantiomer of paclobutrazol, myclobutanil, and uniconazole, respectively. Recovery and precision data showed that the pretreatment procedures were satisfactory for enantiomer extraction and cleanup. This method can be used for optical purity determination of technical material and analysis of environmental residues.  相似文献   

7.
Summary N-Protected aminoacids have been chemically bonded to aminopropylated silica gel, and the resulting chiral phases have been applied to the LG resolution of racemic mixtures of polar compounds. Best results were obtained with surfacebound N-formyl-isoleucine and N-formylvaline, with which baseline resolutions of a range of aminoacid and aminoalcohol derivatives were achieved.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

8.
Column packings widely used for high-performance liquid chromatography (HPLC) mostly are based on porous silica microspheres with certain pore sizes and pore size distributions. Such materials have the most desirable compromise of properties that provide for effective and reproducible separations over a wide range of operating conditions. To provide desired separation characteristics, several manufacturers specially synthesize the silica particles for these packings. While such column packing materials have general utility for a wide range of needs, special silica-based particles have been synthesized with different physical conformations for special separation goals. This presentation describes some atypical types of silica-based particles with unique separation properties that enlarge the capabilities of HPLC methods.  相似文献   

9.
10.
11.
12.
This paper describes validated high-performance liquid chromatographic (LC) and high-performance thin-layer chromatographic (TLC) methods for the simultaneous estimation of olanzapine and fluoxetine in pure powder and tablet formulations. The LC separation was achieved on a Lichrospher 100 RP-180, C18 column (250 mm, 4.0 mm id, 5 microm) using 0.05 M potassium dihydrogen phosphate buffer (pH 5.6 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1 mL/min and ambient temperature. The TLC separation was achieved on aluminum sheets coated with silica gel 60F254 using methanol-toluene (40 + 20, v/v) as the mobile phase. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 10-70 and 40-280 microg/mL with mean recovery of 99.54 +/- 0.89 and 99.73 +/- 0.58% for olanzapine and fluoxetine, respectively, by the LC method. Quantitation was achieved by measuring ultraviolet absorption at 233 nm over the concentration range of 100-800 and 400-3200 ng/spot with mean recovery of 101.53 +/- 0.06 and 101.45 +/- 0.35% for olanzapine and fluoxetine, respectively, by the TLC method with densitometry. These methods are simple, precise, and sensitive, and they are applicable for simultaneous determination of olanzapine and fluoxetine in tablet formulations.  相似文献   

13.
Stability constants of binary Fe(III)-methylcysteine, Cr(III)-methylcysteine and mixed Fe(III)-methylcysteine-cysteine, Cr(III)-methylcysteine-cysteine complexes have been determined by paper electrophoresis at 0.1 M ionic strength and a temperature of 35 degrees C. The stability constants of Fe(III)-methylcysteine-cysteine and Cr(III)-methylcysteine-cysteine mixed complexes were found to be 6.00 +/- 0.07 and 5.05 +/- 0.15 (logarithm of stability constant values), respectively.  相似文献   

14.
An adsorbent for the high-performance affinity chromatography of antisteroid antibodies was prepared, based on a commercial pre-packed column. The column contained activated microparticulate silica beads bearing epoxide functions, on which the steroid dexamethasone was covalently linked. The column was used successfully for the rapid and complete isolation of several hundred microgram amounts of specific antidexamethasone antibodies from rabbit antisera. The practical aspects of the purification procedure, especially the optimization of the washing and of the elution steps, are detailed. Despite non-biospecific elution with 20% acetonitrile in an acidic buffer, the purification yield was very satisfactory and the biological activity of the purified immunoglobulins appeared excellent.  相似文献   

15.
For the investigation of a diol phase (Inertsil Diol column) in hydrophilic interaction chromatography, urea, sucrose and glycine were used as test compounds. The chromatographic conditions were investigated for optimal column efficiency. The column temperature used in common reversed-phase liquid chromatography could also be used for the separation and the flow-rate should be adjusted to 0.3-0.5 ml/min to optimize column efficiency. It is suggested that the velocity of the hydrophilic interaction is slower than the hydrophobic interaction in RPLC. The addition of trifluoroacetic acid is effective for the retention of glycine, but ineffective for urea and sucrose. The diol phase exhibited sufficient chemical stability even if exposed to water in high percentage, and could be applied with isocratic elution for the separation/analysis of amino acids and glucose.  相似文献   

16.
17.
N. Mellor 《Chromatographia》1982,16(1):359-363
Summary Many analysts are not taking full advantage of the high speed possibilities of modern LC. Some analytical procedures reported in the literature, and many in regular use in control laboratories, could be achieved in less time without loss in precision. Some factors which affect retention times are discussed and the advantages and disadvantages of employing shorter column lengths and finer packing materials in reversed-phase HPLC are examined. The effect on efficiency of increased flow rates with 10,5 and 3 m ODS materials is shown. The ability to couple shorter column lengths without loss of efficiency is also demonstrated. This allows a minimum length to be selected that gives adequate resolution. Examples of high speed separations are shown and limitations in state of the art HPLC equipment and chromatographic data systems are discussed briefly.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

18.
19.
A procedure is presented for the rapid evaluation of HPLC stationary phase stability at pH 8.4 or 10.1 using a temperature of 60 degrees C. Mobile phase (MeOH-0.1 mol l(-1) aqueous NaHCO3, 50:50, v/v) is continuously passed through the column with periodic injections of a test solution until the several chromatographic parameters of the resulting chromatograms are degraded. The tests were applied to several commercial and laboratory-made stationary phases. After degradation two of these phases, one commercial and one laboratory-made, were examined by elemental analysis and scanning electron microscopy to elucidate the degradation process.  相似文献   

20.
We describe an improved method for purification of sedimentary vanadyl and nickel porphyrins (i.e., naturally occurring metalloalkylporphyrins). For the purpose of compound-specific isotopic analyses, various sedimentary porphyrins were purified from the complex natural mixtures by the dual-step high-performance liquid chromatography (HPLC) method. The high-sample-capacity reversed-phase HPLCs by adding N,N-dimethylformamide to the mobile phase allow an efficient collection of fractions containing the target compounds even using analytical-scale columns. Furthermore, this method achieved improved chromatographic resolutions but significantly reduced the overall retention time down to 60% compared with the previous work. The target compounds were then isolated with the normal-phase HPLC with the baseline-resolution, which is necessary to avoid chromatographic isotopic fractionation. One of the advantages of this method is that it requires neither derivatization nor demetallation. The purity of these isolated compounds was demonstrated by various HPLC online detection methods utilizing a photodiode-array detector, a mass selective detector. The overall recoveries of Ni porphyrin, VO porphyrin, and porphyrin-free base, respectively, were estimated to be approximately 50-60%, 65%, and 85%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号