首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hu X  Pan J  Hu Y  Huo Y  Li G 《Journal of chromatography. A》2008,1188(2):97-107
Molecularly imprinted polymer (MIP) is widely used in many fields because of its characteristics of high selectivity, chemical stability and easy preparation. To enhance the selectivity and applicability of solid-phase microextraction (SPME), a novel MIP-coated SPME fiber was firstly prepared by multiple co-polymerization method with tetracycline as template. It could be coupled directly to high-performance liquid chromatography (HPLC) and used for trace analysis of tetracyclines (TCs) in complicated samples. The characteristics and application of the fibers were investigated. The electron microscope provided a crosslinked and porous surface, and the average thickness of the MIP coating was 19.5 microm. Compared with the non-imprinted polymer (NIP) coated fibers, the special selectivity to tetracycline and structure-similar oxytetracycline, doxycycline, chlortetracycline were discovered with the MIP-coated fibers. The adsorption and desorption of TCs with the MIP-coated fiber could be achieved quickly. A method for the fluorimetric determination of four TCs by the MIP-coated SPME coupled with HPLC was developed. The optimized extraction conditions such as extraction solvent, desorption solvent, and stirring speed were studied. Linear ranges for the four TCs were 5.00-200 microg/L and detection limits were within the range of 1.0-2.3 microg/L. The method was applied to simultaneous multi-residue analysis of four TCs in the spiked chicken feed, chicken muscle, and milk samples with the satisfactory recoveries.  相似文献   

2.
Molecular imprinted polymer (MIP) as solid-phase microextraction (SPME) fibers coating has gained great attention in recent years. In this study, a simple preparation approach for bisphenol A (BPA) MIP coating with controlled thickness on fused-silica capillaries was developed. A capillary was inserted into a larger bore capillary to form a sleeve as mold. The prepolymer solution containing the template BPA was introduced into the interspace between the two capillaries for polymerization under photoirradiation. The larger bore capillary was removed away after the polymerization, and MIP coating with certain thickness on the surface of the inserted capillary was obtained. SPME conditions based on the MIP-coated fibers were optimized, and the extraction performance of the fibers with different thickness coating was compared. Finally, the MIP fibers were used for selective extraction of BPA spiked in tap water, human urine, and milk samples. The average recoveries of spiked BPA in the three samples were 92.5%, 81.6%, and 87.5%, respectively. The present analytical performance is not up to par for applicability to real environmental matrices. Further improvement will be necessary for analysis of real complex samples.  相似文献   

3.
Novel molecularly imprinted polymer (MIP)-coated fibers for solid-phase microextraction (SPME) fibers were prepared by using linezolid as the template molecule. The characteristics and application of these fibers were investigated. The polypyrrole, polythiophene, and poly(3-methylthiophene) coatings were prepared in the electrochemical polymerization way. The molecularly imprinted SPME coatings display a high selectivity toward linezolid. Molecularly imprinted coatings showed a stable and reproducible response without any influence of interferents commonly existing in biological samples. High-performance liquid chromatography with spectroscopic UV and mass spectrometry (MS) detectors were used for the determination of selected antibiotic drugs (linezolid, daptomycin, amoxicillin). The isolation and preconcentration of selected antibiotic drugs from new types of biological samples (acellular and protein-free simulated body fluid) and human plasma samples were performed. The SPME MIP-coated fibers are suitable for the selective extraction of antibiotic drugs in biological samples.  相似文献   

4.
An improved multiple co-polymerization technique was developed to prepare a novel molecularly imprinted polymer (MIP)-coated solid-phase microextraction (SPME) fiber with propranolol as template. Investigation was performed for the characteristics and application of the fibers. The MIP coating was highly crosslinked and porous with the average thickness of only 25.0 μm. Consequently, the adsorption and desorption of β-blockers within the MIP coating could be achieved quickly. The specific selectivity was discovered with the MIP-coated fibers to propranolol and its structural analogues such as atenolol, pindolol, and alprenolol. In contrast, only non-specific adsorption could be shown with the non-imprinted polymer (NIP)-coated fibers, and the extraction efficiencies of propranolol and pindolol with the MIP-coated fibers were higher markedly than that with the commercial SPME fibers. A MIP-coated SPME coupled with high-performance liquid chromatography (HPLC) method for propranolol and pindolol determination was developed under the optimized extraction conditions. Linear ranges for propranolol and pindolol were 20–1000 μg L−1 and detection limits were 3.8 and 6.9 μg L−1, respectively. Propranolol and pindolol in the spiked human urine and plasma samples, extracted with organic solvent firstly, could be simultaneous monitored with satisfactory recoveries through this method.  相似文献   

5.
With characteristics of specific selectivity,good chemical stability and easy preparation,molecularly imprinted polymer (MIP) has been used as the recognition materials m various fields ~([1,2]).Recently,the application of MIP in the sample pre-treatment techniques such as SPME was attractive ~([3,4]).For analysis of complicated samples,the interference matrix would be reduced obviously with the MIP-coated SPME fiber~([5-7]).Because MIPs were coated on the surface of silica fiber through chemical bonding,those fibers could be used for over 80 times without obvious losing of surface quality and extraction performance of MIP coatings.  相似文献   

6.
Surface reversible addition-fragmentation chain transfer (RAFT) polymerization method was firstly applied to the preparation of molecularly imprinted polymer (MIP) coated silicon solid-phase microextraction (SPME) fibers. With Sudan I as template, an ultra-thin MIP coating with about 0.55-μm thickness was obtained with homogeneous structure and controlled composition, due to the controllable radical growing and chain propagation in surface RAFT polymerization. The MIP-coated fibers were found with enhanced selectivity coefficients (3.0–6.5) to Sudan I–IV dyes in contrast with those reported in our previous work. Furthermore, the ultra-thin thickness of MIP coating was helpful to the effective elution of template and fast adsorption/desorption kinetics, so only about 18 min was needed for MIP-coated SPME operation. The detection limits of 21–55 ng L−1 were achieved for four Sudan dyes, when MIP-coated SPME was coupled with liquid chromatography (LC) and mass spectrometry (MS) detection. The MIP-coated SPME–LC–MS/MS method was tested for the monitoring of ultra trace Sudan dyes in spiked chilli tomato sauce and chilli pepper samples, and high enrichment effect, remarkable matrix peaks-removing capability, and consequent high sensitivities were achieved to four Sudan dyes.  相似文献   

7.
Yuling Hu 《Talanta》2010,80(5):2099-46
The combination of molecular imprinting and solid-phase microextraction (SPME) technique provides a powerful sample preparation tool in terms of selectivity, simplicity, and flexibility. This paper reports a novel molecularly imprinted polymer (MIP) coated SPME fiber with 17β-estradiol as template by improved multiple co-polymerization method. The obtained fiber exhibits excellent characteristics such as high porosity, good thermal and chemical stability. Extraction performance shows that the MIP-coated fiber has stronger affinity to the template molecule as compared with the commercial SPME fibers and the control polymer-coated fiber without addition of template. Owing to the shape and structural compatibility, the obtained fiber also demonstrated specific selectivity to the structural related compounds of 17β-estradiol, such as estriol, estrone and 17α-ethynylestradiol, and thus can be applied to simultaneous determination of these estrogens from complex samples coupled with high performance liquid chromatography. The variables that influence extraction were investigated. The MIP-coated fiber demonstrated its efficiency for extraction of estrogens in fishery samples. The detection limits were in the range of 0.98-2.39 μg L−1, and the recoveries were 80.0-83.6% and 85.0-94.1% for fish and shrimp tissue samples, respectively.  相似文献   

8.
A novel molecularly imprinted polymer (MIP) that was applied to a solid-phase micro-extraction (SPME) device, which could be coupled directly to gas chromatograph and mass spectrometer (GC/MS), was prepared using dibutyl phthalate (DBP) as the template molecule. The characteristics and application of this fiber were investigated. Electron microscope images indicated that the MIP-coated solid-phase micro-extraction (MI-SPME) fibers were homogeneous and porous. The extraction yield of DBP with the MI-SPME fibers was higher than that of the non-imprinted polymer (NIP)-coated SPME (NI-SPME) fibers. The MI-SPME fibers had a higher selectivity to other phthalates that had similar structures as DBP. A method was developed for the determination of phthalates using MI-SPME fibers coupled with GC/MS. The extraction conditions were optimized. Detection limits for the phthalate samples were within the range of 2.17-20.84 ng L−1. The method was applied to five kinds of phthalates dissolved in spiked aqueous samples and resulted in recoveries of up to 94.54-105.34%, respectively. Thus, the MI-SPME fibers are suitable for the extraction of trace phthalates in complicated samples.  相似文献   

9.
In this research, a novel strategy was developed to prepare molecularly imprinted polymer (MIP) coated solid-phase microextraction fibers on a large scale with Sudan I as template and stainless steel fibers as substrate. More than 20 fibers could be obtained in one glass tube, and the efficiency and coating repeatability were enhanced remarkably in contrast with the yield of only one fiber in our previous works. The obtained MIP-coated stainless steel fibers were characterized by homogeneous and highly cross-linked coating, good chemical and thermal stabilities, high extraction capacities, and specific selectivities to Sudan I–IV dyes. Based on the systemic optimization of extraction conditions, a simple and cost-effective method based on the coupling of MIP-coated SPME with high-performance liquid chromatography was developed for the fast and selective determination of trace Sudan I–IV dyes in hot chili powder and poultry feed samples. The limits of detection of Sudan I–IV dyes were within 2.5–4.6 ng g?1, and the spiked recoveries were in the range of 86.3–96.3% for hot chili powder sample and 84.6–97.4% for poultry feed sample.  相似文献   

10.
The fabrication of a solid-phase microextraction (SPME) fiber through UV-induced polymerization of poly(ethylene glycol) diacrylate (PEG-DA) for determination of parabens in cosmetic products is presented in this work. The PEG-DA polymer coating was covalently attached to the fiber by introducing a surface modification with 3-(trichlorosilyl)propyl methacrylate (TPM). The PEG-DA polymer thin film coated on the fiber was homogeneous and wrinkled, which led to an increase of the surface area and high extraction efficiency. The extraction performances of the prepared SPME fibers were assessed by preconcentration of parabens including methylparaben, ethylparaben, propylparaben and benzylparaben from cosmetic products. The analysis was performed on an ultra high-speed liquid chromatography with diode array detector. The prepared SPME fibers exhibited good repeatability (for one fiber) and reproducibility (fiber-to-fiber) with RSDs of 5.4 and 6.9%, respectively. The optimized SPME method supported a wide linear range of 0.50-160 μg/mL and the detection limits for parabens were in the range of 0.12-0.15 μg/mL (S/N=3). The developed method was successfully applied for determination of parabens in cosmetic products with different natures.  相似文献   

11.
《Analytical letters》2012,45(7):1358-1370
A molecularly imprinted polymer (MIP) with metolachlor as the template molecule was first coated on the surface of stainless steel fibers through chemical bonding. Despite 12 times repeated coating procedures, a homogenous, porous, and highly cross-linked MIP coating was obtained with thickness of 17.4 µm (RSD of 6.1%). The specific selectivity of MIP coating to metolachlor and three metabolites could be concluded with 4.4, 4.1, 3.9, and 2.9 times higher extraction amounts of metolachlor, hydroxymetolachlor, deschlorometolachlor, and desmethylmetolachlor than that of the NIP coating, respectively, and good extraction capabilities for chloroacetanilide herbicides were found with the MIP-coated SPME stainless steel fiber. For validation, the fiber was applied for the extraction of metolachlor, propisochlor, and butachlor in spiked corn and soybean samples, and the recoveries of 90.7–92.6%, 86.4–87.9, and 85.4–87.5% were obtained, respectively.  相似文献   

12.
In this paper, a simple, fast and in situ polymerization strategy to prepare monolithic molecularly imprinted polymer (MIP) fibers for solid phase microextraction (SPME) is developed using silica capillaries as molds. With the help of microwave irradiation, polymerization was carried out in 5.5 min using olivetol as a template molecular, α‐methacrylic acid (MAA) as a functional monomer and ethylene dimethacrylate (EDMA) as a crosslinker, toluene and dodecanol as the binary porgens. The resulted MIP fibers were finally obtained after silica being etched away with a controlled length, and subsequently characterized by scanning electron microscope (SEM) and Fourier transform infrared absorption spectroscopy (FT‐IR). Under the optimal extraction conditions, a simple method based on the coupling of MIP SPME with high performance liquid chromatography (HPLC) was used for the selective determination of the model mixtures of olivetol, phenol and m‐toluidine in lake water and wheat bran samples. The recoveries of olivetol, phenol and m‐toluidine for both samples were in the range of 87.3‐93.6%, 21.4‐27.2%, 18.9‐24.8% at three spiked levels, respectively, demonstrating that higher extraction and the specific absorption occurred between the template molecule and the prepared MIP fiber.  相似文献   

13.
Zhuomin Zhang  Xi Chen 《Talanta》2009,78(3):1083-1240
A new solid phase microextraction (SPME) method coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of four anabolic steroids such as 3α-hydroxy-5α-androstane-17-one (HA), dihydrotestosterone (DHT), androstenedione (AD) and methyltestosterone (MT) in pig urine. SPME was used to extract the four anabolic compounds directly without derivatization. The optimum SPME sampling conditions were based on the home-made carbowax-divinylbenzene (CW-DVB) fiber coating during extraction at 40 °C for 50 min with 0.18 g/mL NaCl solution and 750 rpm stirring speed. The linear ranges of the proposed method were in the range of 8-640 pg/mL for HA and DHT and 16-510 pg/mL for AD and MT, respectively. The detection limits (S/N = 3) were from 2 to 8 pg/mL for the four anabolic steroids. This SPME method provided very high enrichment factors for the four anabolic steroids, which were 1063-fold and 965-fold for HA and DHT at the concentration of 8 pg/mL and 207-fold and 451-fold for AD and MT at the concentration of 16 pg/mL, respectively. The recoveries ranged from 71.3 to 121%, and the RSDs were lower than 12.9%. The method was sensitive and reliable for determination of trace anabolic steroids in biological samples.  相似文献   

14.
A novel capillary electrophoresis (CE) method coupled with monolithic molecular imprinted polymer (MIP) fiber based solid phase microextraction (SPME) was developed for selective and sensitive determination of ephedrine (E) and pseudoephedrine (PE). With in situ polymerization in a silica capillary mold and E as template, the MIP fibers could be produced in batch reproducibly and each fiber was available for 50 extraction cycles without significant decrease in extraction ability. Using the MIP fiber under optimized extraction conditions, CE detection limits of E and PE were greatly lowered from 0.20 to 0.00096 μg/mL and 0.12 to 0.0011 μg/mL, respectively. Analysis of urine and serum samples by the MIP-SPME-CE method was also performed, with results indicating that E and PE could be selectively extracted. The recoveries and relative standard deviations (RSDs) for sample analysis were found in the range of 91–104% and 3.8–9.1%, respectively.  相似文献   

15.
A novel liquid–liquid–solid microextraction (LLSME) technique based on porous membrane-protected molecularly imprinted polymer (MIP)-coated silica fiber has been developed. In this technique, a MIP-coated silica fiber was protected with a length of porous polypropylene hollow fiber membrane which was filled with water-immiscible organic phase. Subsequently the whole device was immersed into aqueous sample for extraction. The LLSME technique was a three-phase microextraction approach. The target analytes were firstly extracted from the aqueous sample through a few microliters of organic phase residing in the pores and lumen of the membrane, and were then finally extracted onto the MIP fiber. A terbutylazine MIP-coated silica fiber was adopted as an example to demonstrate the feasibility of the novel LLSME method. The extraction parameters such as the organic solvent, extraction and desorption time were investigated. Comparison of the LLSME technique was made with molecularly imprinted polymer based solid-phase microextraction (MIP-SPME) and hollow fiber membrane-based liquid-phase microextraction (HF-LPME), respectively. The LLSME, integrating the advantages of high selectivity of MIP-SPME and enrichment and sample cleanup capability of the HF-LPME into a single device, is a promising sample preparation method for complex samples. Moreover, the new technique overcomes the problem of disturbance from water when the MIP-SPME fiber was exposed directly to aqueous samples. Applications to analysis of triazine herbicides in sludge water, watermelon, milk and urine samples were evaluated to access the real sample application of the LLSME method by coupling with high-performance liquid chromatography (HPLC). Low limits of detection (0.006–0.02 μg L−1), satisfactory recoveries and good repeatability for real sample (RSD 1.2–9.6%, n = 5) were obtained. The method was demonstrated to be a fast, selective and sensitive pretreatment method for trace analysis of triazines in complex aqueous samples.  相似文献   

16.
A field expedient analytical method for detecting the chemical warfare agent (CWA) sulfur mustard as a soil contaminant was developed using solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Five commercially available SPME fibers were investigated to determine the optimal fiber, and extraction conditions. Polyacrylate and carbowax-divinylbenzene fiber coatings gave a statistically indistinguishable and best response compared to the other three types examined in a simple system studied without soil. The polyacrylate fiber coating was selected for study of a system in which sulfur mustard was spiked to an agricultural soil (Standard Reference Material 2709, San Joaquin type). With soil samples, the greatest sensitivity occurred by the addition of deionized water to spiked soil and extraction at ambient temperature for 20 min or longer. SPME sampling with GC-MS analyses afforded good reproducibility (relative standard deviation between 2 and 10%), and analyte concentrations as low as 237 ng/g were detected in soil (total ion chromatograms). As completed here, total time for sampling and analysis was just under 1 h, and use of organic solvents or special sample introduction equipment was avoided.  相似文献   

17.
The preparation, properties and application of carbon fibers for SPME   总被引:1,自引:0,他引:1  
Gierak A  Seredych M  Bartnicki A 《Talanta》2006,69(5):1079-1087
The conditions of preparation of new types of carbon fibers for solid phase micro extraction (SPME) prepared by methylene chloride pyrolysis (at 600 °C) on the quartz fiber (100 μm) as well as by supporting synthetic active carbon (prepared especially for this purposes) supported in a special epoxide-acrylic polymer is described. The properties of such carbon fibers for SPME were defined by determination of the partition coefficient of the tested substances (i.e., benzene, toluene, xylenes, trichloromethane and tetrachloromethane) and by the microscopic investigations with the application of the optical and scanning electron microscope.

The obtained carbon SPME fibers were applied to the analysis of some volatile organic compounds from its aqueous matrix. During chromatographic GC test, at the investigated SPME carbon fibers, we obtained different but mostly high partition coefficients for the determined compounds (Kfs from 120 for trichloromethane up to 11,500 for tetrachloromethane).

Owing to the high partition coefficients of the studied substances obtained on carbon fibers, it was possible to do the analysis of organic substances occurring in trace amounts in different matrices. In this paper, we present the analysis of BTX contents in the petrol analyzed with the application carbonized with CH2Cl2 SPME fiber (C1NM) and a headspace over the petrol sample (concentration of each BTX g/dm3).  相似文献   


18.
《Analytical letters》2012,45(4):645-660
Abstract

A novel reproducible solid‐phase microextraction (SPME) coating was prepared on the surface of silanized silica fibers by molecularly imprinted polymerization using prometryn as template molecule. The structure and extraction performance of molecularly imprinted polymer (MIP) coating was studied with the scanning electron microscope and high performance liquid chromatography (HPLC). Specific selectivity was found with the prometryn MIP‐coated fiber to prometry and its structural analogues such as atrazine, simetryn, terbutylazin, ametryn, propazine and terbutryn. In contrast, these triazines could not be selectively extracted by the non‐imprinted polymer fiber or commercial polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB), polyacrylate (PA) fibers.  相似文献   

19.
A monolithic solid-phase microextraction (SPME) fiber was fabricated based on a molecularly imprinted polymer which could be coupled with gas chromatography for extraction, pre-concentration and determination of methamphetamine (MAMP). Methacrylic acid, ethylene glycol dimethacrylate and MAMP play the roles of functional monomer, cross-linker and template, respectively. The effective factors influencing the polymerization and extraction procedures were investigated and will be detailed here. The fabricated fiber was firm, inexpensive, stable, selective and durable which gives it vital importance in SPME. Selectivity of the fabricated fiber in relation to the template in solution containing MAMP, related and unrelated compounds was also investigated. Under the optimum conditions, the calibration plot was linear in the range of 50?C3,500 ng mL?1 (r 2  = 0.997). The high extraction efficiency was obtained for MAMP giving a detection limit of 14 ng mL?1. The fabricated fiber was successfully applied to SPME of MAMP from human saliva samples followed by gas chromatography-flame ionization detector analysis.  相似文献   

20.
A highly porous fiber-coated SBA-15/polyaniline material was prepared for solid-phase microextraction (SPME). The SBA-15/polyaniline nanocomposite was synthesized via chemical polymerization. The prepared SBA-15/polyaniline particles were analyzed by scanning electron microscopy analysis. The prepared nanomaterial was immobilized onto a stainless steel wire for fabrication of the SPME fiber. The fiber was evaluated for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions in combination with gas chromatography-mass spectrometry (GC-MS). In optimum conditions (extraction temperature 60°C, extraction time 40 min, ionic strength 20%, stirring rate: 500 rpm, desorption temperature 260°C, desorption time 2 min), the repeatability for one fiber (n=3), expressed as relative standard deviation (RSD%), was between 5.3 and 8.6% for the test compounds. For deionized water, spiked with selected PAHs, the detection limits for the studied compounds were between 2 and 20 pg/mL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号