 共查询到20条相似文献,搜索用时 859 毫秒
1.
A matrix-assisted laser desorption/ionization (MALDI) source has been coupled to a tandem quadrupole/time-of-flight (QqTOF) mass spectrometer by means of a collisional damping interface. Mass resolving power of about 10,000 (FWHM) and accuracy in the range of 10 ppm are observed in both single-MS mode and MS/MS mode. Sub-femtomole sensitivity is obtained in single-MS mode, and a few femtomoles in MS/MS mode. Both peptide mass mapping and collision-induced dissociation (CID) analysis of tryptic peptides can be performed from the same MALDI target. Rapid spectral acquisition (a few seconds per spectrum) can be achieved in both modes, so high throughput protein identification is possible. Some information about fragmentation patterns was obtained from a study of the CID spectra of singly charged peptides from a tryptic digest of E. coli citrate synthase. Reasonably successful automatic sequence prediction (>90%) is possible from the CID spectra of singly charged peptides using the SCIEX Predict Sequence routine. Ion production at pressures near 1 Torr (rather than in vacuum) is found to give reduced metastable fragmentation, particularly for higher mass molecular ions. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

2.
Four liquid chromatography/mass spectrometry (LC/MS) systems, equipped with single quadrupole, triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole time-of-flight (QqTOF) mass analyzers, were evaluated for the analysis of carbosulfan and its main transformation products. The comparison of quantitative aspects (sensitivity, precision and accuracy) was emphasized. Results showed that the triple quadrupole instrument reaches at least 20-fold higher sensitivity (LOD from 0.04 to 0.4 microg kg(-1)) compared to the single quadrupole (4-70 microg kg(-1)), the QIT (4-25 microg kg(-1)) and the QqTOF (4-23 microg kg(-1)) instruments. Recoveries were over 70% for all the analytes, except dibutylamine and 7-phenolcarbofuran. Repeatabilities (within-day) were slightly better by the single quadrupole (5-10%) and the QqQ (5-9%) than by the QIT (12-16%) and the QqTOF (9-16%). Both the QqTOF and QIT offer a linear dynamic range of two orders of magnitude whereas the single quadrupole and QqQ of, at least, three orders of magnitude. The method was applied to analyze carbosulfan field-treated orange samples, in which carbosulfan, carbofuran, 3-hydroxycarbofuran, and dibutylamine were found. As an example, the mean carbosulfan concentration was 20 +/- 0.6 microg kg(-1) measured by the QqQ, 22 +/- 1.2 microg kg(-1) by the single quadrupole, 25 +/- 2.8 microg kg(-1) by the QIT, and 20 +/- 1.8 microg kg(-1) by the QqTOF. Although the QqQ is more sensitive and precise, the mean values obtained by the four instruments are acceptable and comparable. The potential of each technique for the verification of the identity of residues detected in oranges is discussed using the concept of identification points.  相似文献   

3.
Three different liquid chromatography-mass spectrometry (LC-MS) instruments equipped with triple quadrupole (QqQ), quadrupole ion trap (QIT) and quadrupole-time-of-flight (QqTOF), suitable to carry out tandem mass spectrometry, were examined to determine pesticide residues in food. Twelve pesticides (acrinathrin, bupirimate, buprofezin, cyproconazole, lambda-cyhalothrin, fluvalinate, hexaflumuron, kresoxim-methyl, propanil, pyrifenox, pyriproxyfen and tebufenpyrad) and six matrices (oranges, strawberries, cherries, peaches, apricots and pears) were taken as model. The comparison was focused on two aspects: the quantitative, covering sensitivity, precision and accuracy as well as the qualitative, checking the possibility to identify any metabolite present in the samples, which were not targeted in the methods. The extraction was carried out using pressurized liquid extraction (PLE) with ethyl acetate and acid alumina. Recoveries were over 70 % for all the analytes. Repeatabilities were better for the QqQ (5-12%) than for QIT (6-15%) and for QqTOF (14-19%). QqQ offered a linear dynamic range of at least three orders of magnitude, whereas those of QIT and QqTOF were two and one orders of magnitude, respectively. QqQ reached at least 20-fold higher sensitivity than QIT and QqTOF. However, the QqQ failed to identify non-target compounds. QIT and QqTOF were able to successfully identify the metabolite of bupirimate, ethirimol. Application to monitor the content in fruits, taken from agricultural cooperatives, and to calculate the estimated daily intake (EDI) to establish if there is any difference of toxicological interest is also reported.  相似文献   

4.
Within the European Union the use of anabolic steroids for promoting growth and improving meat-to-fat ratio in food-producing animals has been banned since 1988. For the unequivocal identification of hormone residues in a complex matrix such as meat we have developed a rapid, specific and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, in combination with a simple extraction procedure based on the matrix solid-phase dispersion (MSPD). The performances of a triple quadrupole (QqQ) and a quadrupole/time-of-flight (QqTOF) were compared: the QqQ mass spectrometer was found to be more sensitive for almost all studied analytes, but the selectivity was superior using the QqTOF system; the full-scan spectra (acquired without losing sensitivity), mass accuracy and resolution of the hybrid instrument enabled a more probatory analyte identification than that obtained selecting two multiple-reaction monitoring (MRM) transitions with a QqQ. Average recoveries ranged from 80 to 100%, and the detection capabilities (CCbetas) were less than 1.06 ppb with the QqQ instrument and less than 5.20 ppb with the QqTOF instrument for the bovine meat, which proved to be the most complex matrix.  相似文献   

5.
A method has been developed for rapid and sensitive identification of epitope-containing peptides, based on direct MALDI-MS/MS analysis of epitope-containing peptides affinity bound to affinity beads. This technique provides sequence information of the epitope that allows unambiguous identification of the epitope either by database searching or de novo sequencing. With MALDI-MS, affinity beads with bound peptides can be placed directly on the MALDI target and analyzed. Coupling a MALDI source to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer allows direct sequencing of the bound peptides. In contrast to ESI-MS/MS, elution of the affinity-bound peptides followed by additional concentration and purification steps is not required, thus reducing the potential for sample loss. Direct mass spectrometric sequencing of affinity-bound peptides eliminates the need for chemical or enzymatic sequencing. Other advantages of this direct MALDI-MS/MS analysis of epitope-containing peptides bound to the affinity beads include its sensitivity (femtomole levels) and speed. In addition, direct analysis of peptides on affinity beads does not adversely affect the high mass accuracy of a QqTOF, and database searching can be performed on the MS/MS spectra obtained. In proof-of-principle experiments, this method has been demonstrated on beads containing immobilized antibodies against phosphotyrosine, the c-myc epitope tag, as well as immobilized avidin. Furthermore, de novo sequencing of epitope-containing peptides is demonstrated. The first application of this method was with anti-FLAG-tag affinity beads, where direct MALDI MS/MS was used to determine an unexpected enzymatic cleavage site on a growth factor protein.  相似文献   

6.
Close deposition of the sample and external standard was used in axial matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) to achieve mass accuracy equivalent to that obtained with an internal standard across the entire MALDI plate. In this work, the sample and external standard were deposited by continuous deposition in separate traces, each approximately 200 micro m wide. The dependence of the mass accuracy on the distance between the sample and standard traces was determined across a MALDI target plate with dimensions of 57.5 mm x 57.0 mm by varying the gap between the traces from 100 micro m to 4 mm. During acquisition, two adjacent traces were alternately irradiated with a 200-Hz laser, such that the peaks in the resulting mass spectra combined the sample and external standard. Ion suppression was not observed even when the peptide concentrations in the two traces differed by more than two orders of magnitude. The five peaks from the external standard trace were used in a four-term mass calibration of the masses of the sample trace. The average accuracy across the whole plate with this method was 5 ppm when peaks of the sample trace had signal-to-noise ratios of at least 30 and the gap between the traces was approximately 100 micro m. This approach was applied to determining peptide masses of a reversed-phase liquid chromatographic (LC) separation of a tryptic digest of beta-galactosidase deposited as a long serpentine trace across the MALDI plate, with accuracy comparable to that obtainable using internal calibration. In addition, the eluent from reversed-phase LC separation of a strong cation-exchange fraction containing tryptic peptides from a yeast lysate along with the closely placed external standard was deposited on the MALDI plate. The data obtained in the MS and MS/MS modes on a MALDI-TOF/TOF mass spectrometer were combined and used in database searching with MASCOT. Since the significant score is a function of mass accuracy in the MS mode, database searching with high mass accuracy reduced the number of false positives and also added peptides which otherwise would have been eliminated at lower mass accuracy (false negatives).  相似文献   

7.
With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.  相似文献   

8.
This paper focuses on development of time‐of‐flight (TOF) mass spectrometry in response to the invention of matrix‐assisted laser desorption/ionization (MALDI). Before this breakthrough ionization technique for nonvolatile molecules, TOF was generally considered as a useful tool for exotic studies of ion properties but was not widely applied to analytical problems. Improved TOF instruments and software that allow the full potential power of MALDI to be applied to difficult biological applications are described. A theoretical approach to the design and optimization of MALDI‐TOF instruments for particular applications is presented. Experimental data are provided that are in excellent agreement with theoretical predictions of resolving power and mass accuracy. Data on sensitivity and dynamic range using kilohertz laser rates are also summarized. These results indicate that combinations of high‐performance MALDI‐TOF and TOF‐TOF with off‐line high‐capacity separations may ultimately provide throughput and dynamic range several orders of magnitude greater than those currently available with electrospray LC‐MS and MS‐MS. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) has proven a convenient and rapid method for ion production in the mass spectrometric (MS) analysis of biomolecules. AP‐MALDI and electrospray ionization (ESI) sources are easily interchangeable in most mass spectrometers. However, AP‐MALDI suffers from less‐than‐optimal sensitivity due to ion losses during transport from the atmosphere into the vacuum of the mass spectrometer. Here, we study the signal‐to‐noise ratio (S/N) gains observed when an on‐chip dynamic pre‐concentration/focusing approach is coupled to AP‐MALDI for the MS analysis of neuropeptides and protein digests. It was found that, in comparison with conventional AP‐MALDI targets, focusing targets showed (1) a sensitivity enhancement of approximately two orders of magnitude with S/N gains of 200–900 for hydrophobic substrates, and 150–400 for weak cation‐exchange (WCX) substrates; (2) improved detection limits as low as 5 fmol/µL for standard peptides; (3) significantly reduced matrix background; and (4) higher inter‐day reproducibility. The improved sensitivity allowed successful tandem mass spectrometric (MS/MS) sequencing of dilute solutions of a derivatized tryptic digest of a protein standard, and enabled the first reported AP‐MALDI MS detection of neuropeptides from Aedes aegypti mosquito heads. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
The present work investigates various method development aspects for the quantitative analysis of pharmaceutical compounds in human plasma using matrix-assisted laser desorption/ionization and multiple reaction monitoring (MALDI-MRM). Talinolol was selected as a model analyte. Liquid-liquid extraction (LLE) and protein precipitation were evaluated regarding sensitivity and throughput for the MALDI-MRM technique and its applicability without and with chromatographic separation. Compared to classical electrospray liquid chromatography/mass spectrometry (LC/ESI-MS) method development, with MALDI-MRM the tuning of the analyte in single MS mode is more challenging due to interfering matrix background ions. An approach is proposed using background subtraction. With LLE and using a 200 microL human plasma aliquot acceptable precision and accuracy could be obtained in the range of 1 to 1000 ng/mL without any LC separation. Approximately 3 s were required for one analysis. A full calibration curve and its quality control samples (20 samples) can be analyzed within 1 min. Combining LC with the MALDI analysis allowed improving the linearity down to 50 pg/mL, while reducing the throughput potential only by two-fold. Matrix effects are still a significant issue with MALDI but can be monitored in a similar way to that used for LC/ESI-MS analysis.  相似文献   

11.
A matrix‐assisted laser desorption/ionization time of flight/time of flight tandem mass spectrometer (MALDI TOF/TOF) has been used for high‐speed precursor/fragment ion transition image acquisition. High‐throughput analysis is facilitated by an Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz, a high digitizer acquisition rate (up to 50 pixels/s), and continuous laser raster sampling. MS/MS experiments are enabled through the use of a precision timed ion selector, second source acceleration, and a dedicated collision cell. Continuous raster sampling is shown here to facilitate rapid MS/MS ion image acquisition from thin tissue sections for the drug rifampicin and for a common kidney lipid, SM4s(d18:1/24:1). The ability to confirm the structural identity of an analyte as part of the MS/MS imaging experiment is an essential part of the analysis. Additionally, the increase in sensitivity and specificity afforded by an MS/MS approach is highly advantageous, especially when interrogating complex chemical environments such as those in biological tissues. Herein, we report continuous laser raster sampling TOF/TOF imaging methodologies which demonstrate 8 to 14‐fold increases in throughput compared with existing MS/MS instrumentation, an important advantage when imaging large areas on tissues. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A prototype matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometer has been used for high-speed ion image acquisition. The instrument incorporates a Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz and continuous laser raster sampling for high-throughput data collection. Lipid ion images of a sagittal rat brain tissue section were collected in 10 min with an effective acquisition rate of roughly 30 pixels/s. These results represent more than a 10-fold increase in throughput compared with current commercially available instrumentation. Experiments aimed at improving conditions for continuous laser raster sampling for imaging are reported, highlighting proper laser repetition rates and stage velocities to avoid signal degradation from significant oversampling. As new high spatial resolution and large sample area applications present themselves, the development of high-speed microprobe MALDI imaging mass spectrometry is essential to meet the needs of those seeking new technologies for rapid molecular imaging.  相似文献   

13.
Mass spectrometry (MS)‐based high‐throughput screening (HTS) has tremendous potential as an alternative to current screening methods due to its speed, sensitivity, reproducibility and label‐free readout. We recently reported that a new generation matrix‐assisted laser desorption/ionization triple quadrupole (MALDI‐QqQ) mass spectrometer is ideally suited for a variety of enzyme assays and screening protocols. However, all the targets measured to date had peptide substrates that were easily monitored by selected ion monitoring (SIM) without interference from the MALDI matrix. To further extend the application to enzymes with small molecule, non‐peptide substrates, we evaluated this method for measuring enzyme activity and inhibition of acetylcholinesterase (AChE). Due to the potential of MALDI matrix interference, multiple reaction monitoring (MRM) was investigated for selective MS/MS transitions and to accurately measure the conversion of acetylcholine into choline. Importantly, ionization, detection and MRM transition efficiency differences between the substrate and product can be overcome by pre‐balancing the MRM transitions during method development, thus allowing for a direct readout of the enzyme activity using the ratio of the substrate and product signals. Further validation of the assay showed accurate concentration‐dependent inhibition measurements of AChE with several known inhibitors. Finally, a small library of 1008 drug‐like compounds was screened at a single dose (10 µM) and the top 10 inhibitors from this primary screen were validated in a secondary screen to determine the rank order of inhibitory potency for each compound. Collectively, these data demonstrate that a MALDI‐QqQMS‐based readout platform is amenable to measuring small molecule substrates and products and offers significant advantages over current HTS methods in terms of speed, sensitivity, reproducibility and reagent costs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.  相似文献   

15.
Current biological studies have been advanced by the continuous development of robust, accurate, and sensitive mass spectrometric technologies. The MALDI LTQ Orbitrap is a new addition to the Orbitrap configurations, known for their high resolving power and accuracy. This configuration provides features inherent to the MALDI source, such as reduced spectra complexity, forgiveness to contaminants, and sample retention for follow-up analyses with targeted or hypothesis-driven questions. Here we investigate its performance for characterizing the composition of isolated protein complexes. To facilitate the assessment, we selected two well characterized complexes from Saccharomyces cerevisiae, Apl1 and Nup84. Manual and automatic MS and MS/MS analyses readily resolved their compositions, with increased confidence of protein identification compared with our previous reports using MALDI QqTOF and MALDI IT. CID fragmentation of singly-charged peptides provided sufficient information for conclusive identification of the isolated proteins. We then assessed the resolution, accuracy, and sensitivity provided by this instrument in the context of analyzing the isolated protein assemblies. Our analysis of complex mixtures of singly-charged ions up to m/z 4000 showed that (1) the resolving power, inversely proportional to the square root of m/z, had over four orders of magnitude dynamic range; (2) internal calibration led to improved accuracy, with an average absolute mass error of 0. 5 ppm and a distribution centered at 0 ppm; and (3) subfemtomole sensitivity was achieved using both CHCA and DHB matrices. Additionally, our analyses of a synthetic phosphorylated peptide in mixtures showed subfemtomole level of detection using neutral loss scanning.  相似文献   

16.
Applications of mass spectrometry to food proteins and peptides   总被引:3,自引:0,他引:3  
The application of mass spectrometry (MS) to large biomolecules has been revolutionized in the past decade with the development of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) techniques. ESI and MALDI permit solvent evaporation and sublimation of large biomolecules into the gaseous phase, respectively. The coupling of ESI or MALDI to an appropriate mass spectrometer has allowed the determination of accurate molecular mass and the detection of chemical modification at high sensitivity (picomole to femtomole). The interface of mass spectrometry hardware with computers and new extended mass spectrometric methods has resulted in the use of MS for protein sequencing, post-translational modifications, protein conformations (native, denatured, folding intermediates), protein folding/unfolding, and protein-protein or protein-ligand interactions. In this review, applications of MS, particularly ESI-MS and MALDI time-of-flight MS, to food proteins and peptides are described.  相似文献   

17.
The need for high‐throughput methodologies providing both qualitative and quantitative information has grown substantially in the pharmaceutical laboratory in recent years. Currently, tandem mass spectrometry (MS/MS) using quadrupole technology offers analysis in the minutes time scale. The use of matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) offers the advantage of speed and automation and enables analysis in the seconds time scale with accurate mass capabilities that are not typically found in quadrupole MS/MS. However, one of the limitations of MALDI for the analysis of small molecules is the abundance of interfering matrix peaks in the low molecular weight region of the mass spectrum. Described herein is an evaluation of a pre‐prepared MALDI target plate that has been coated with a thin layer of α‐cyano‐4‐hydroxycinnamic acid (CHCA) and nitrocellulose. This modified plate has been shown to suppress or eliminate CHCA matrix signals without any significant loss of analyte sensitivity when compared with analysis of the same sample using an unmodified target plate. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

18.
Studies of yessotoxin involving confirmation of fragmentation processes using a high-resolution orthogonal hybrid quadrupole time-of-flight (QqTOF) mass spectrometer and nanoLC hybrid quadrupole TOF MS have been undertaken. The fragmentation of YTX was studied in negative mode using nano electrospray (nanoESI) QqTOF mass spectrometry. Three major molecule-related ions were observed, [M - 2Na + H]-, [M - Na]- and [M - 2Na]2-, and fragmentation of the latter was studied in detail. This showed that product ions were formed as a consequence of charge-remote fragmentation processes that included a strong directional cleavage of the polyether rings of YTX. NanoLC coupled with QqTOF MS was used to determine YTX in small samples of the phytoplankton, Protoceratium reticulatum, by monitoring the [M - 2Na]2- ion at m/z 570. A PepMap C18 nanoLC column (75 microm x 10 cm, 100 A, 3 microm, LC Packings) was used and the solvent was acetonitrile/water (90:10 (v/v)) containing 1 mM ammonium acetate, at a flow rate of 400 nl/min, for 30 min. Calibrations obtained with YTX standard solutions were linear over four orders of magnitude, 0.75-250 ng/ml; r2 = 0.9947-0.9998. Phytoplankton cells (ca. 100-300) were picked, extracted with methanol/water (40:60), and the YTX concentration was determined over the range 0.011-0.020 ng/cell. The detection limit (3 x S/N) of this method was ca. 0.5 pg YTX on-column.  相似文献   

19.
A simple and rapid method using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of the urinary metabolites of benzene, toluene, xylene and styrene in human urine specimens and standard solutions is described. A hybrid quadrupole/time-of-flight (QqTOF) mass spectrometer was compared for the determination of metabolite of aromatic solvents in urine samples. The metabolites selected were: trans,trans-muconic acid, hippuric acid, o-, m- and p-methylhippuric acid and phenylglyoxylic acid. The compounds were well separated from each other on narrow-bore 1-mm i.d. reversed-phase LC C-18 columns. Average recoveries for loading 100 microL of urine samples varied from 88-110% and the quantification limits were less than 30 ng/mL for each analyte (3 ng/mL for trans,trans-muconic acid). The qualitative information obtained (mass accuracy, resolution and full-scan spectra) with the QqTOF mass spectrometer allows a secure identification of analytes in biological matrices.  相似文献   

20.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   