首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The difficulty in using conventional ion chromatography for the determination of sulfate, thiosulfate, dithionate and polythionates (tri-, tetra-, penta- and hexathionate) in their mixtures, comes mainly from very late elutions of polythionates due to their strong retentions onto a separating column. Rapid and sensitive determination of these sulfur oxyanions has been achieved by ion-pair chromatography using a silica octadecylsilane (ODS) column with mobile phases of 10% or 20% (v/v) acetonitrile in water (pH, 5.0) containing 0.2 mM phthalate and 7 mM tetrapropylammonium salt (TPAOH). The sulfur species separated on the column were monitored with a conductivity detector after passing through a micro membrane suppressor in the H+ form. When an acetonitrile-water (10:90, v/v) mobile phase (pH, 5.0) of 0.2 mM phthalate and 7 mM TPAOH was used at a flow-rate of 0.8 ml min−1, sulfate, thiosulfate, dithionate and trithionate were eluted at short retention times of 9.1, 9.7, 11.4 and 15.8 min, respectively; however, the higher polythionates required more than 30 min to elute. When the concentration of acetonitrile in the mobile phase was raised to 20% (v/v), all polythionates of tri- to hexathionate were completely separated from their mixtures within 21 min; in this instance, both sulfate and thiosulfate failed to be resolved due to their close retention times. Good recoveries were obtained for these sulfur oxyanions when added to various hot-spring water samples.  相似文献   

2.
The reduction of iodine with azide, catalyzed by polythionates (tri-, tetra-, penta- and hexathionate) and thiosulfate, has been utilized as a postcolumn reaction for chromatographic determination of these sulfur oxyanions. The method is based on the separation of polythionates and thiosulfate on an octadecylsilica column with an acetonitrile–water (20:80, v/v) mobile phase (pH 5.0) containing 3 mM tetrapropylammonium hydroxide and 6 mM acetic acid, followed by photometric measurement of the residual iodine (as triiodide) from the catalytic postcolumn azide–iodine reaction after mixing a reaction solution containing azide and iodine with the column effluent. Chromatograms obtained for the sulfur oxyanions showed negative peaks as a result of the decrease in absorbance of background. The conditions for the catalytic postcolumn reaction of the sulfur oxyanions in the column effluents were established by varying the concentrations of azide, iodine, iodide and acetic acid in the reaction solution, and varying the flow-rate, reaction temperature and length of the reaction tube. The detection limits (defined as S/N=3) were 4.3 μM for trithionate, 0.10 μM for tetrathionate, 2.7 nM for pentathionate, 5.0 nM for hexathionate and 1.1 nM for thiosulfate. When compared with earlier methods, the proposed method gave a much higher sensitivity for the determination of two polythionates (penta- and hexathionate) and thiosulfate. This method was applied successfully to the analysis of polythionates and thiosulfate added to hot-spring water samples.  相似文献   

3.
Ion chromatography of sulfide, sulfite, sulfate and thiosulfate in a mixture is often difficult because of instability of sulfide and sulfite, poor separation of sulfide from common anions such as bromide or nitrate and similar elution-times for sulfite and sulfate. An ion-pair chromatographic method for the determination of these sulfur anions has been established by stoichiometric conversion of sulfide and sulfite into stable thiocyanate and sulfate, respectively, prior to the chromatographic run. Sulfate, thiosulfate and thiocyanate were resolved on an octadecylsilica column with an acetonitrile-water mobile phase containing tetrapropylammonium salt (TPA) as an ion-paring reagent, and thiosulfate and thiocyanate in the effluent could be measured with a photometric detector (220 nm) and sulfate with a suppressed conductivity detector. When an acetonitrile-water (6:94, v/v) mobile phase (pH 5.0) containing 15 mM TPA and small amounts of acetic acid was used at a flow-rate of 0.6 ml min(-1), the three anions could be eluted within 32 min. Calibration plots of peak height versus concentration for sulfide (detected as thiocyanate) and thiosulfate gave straight lines up to 35 and 60 microM, respectively. The calibration plot for sulfide coincided with that obtained by using thiocyanate. A calibration plot for sulfite, measured as sulfate, was also linear up to 135 microM and was in accord with that of sulfate. Each calibration plot gave a correlation coefficient greater than 0.999. For six replicates obtained for a mixture of 30.0 microM sulfide, 50.0 microM sulfite, 50.0 microM sulfate and 20.0 microM thiosulfate, the proposed method gave a mean value of 30.1 microM with a standard deviation (SD) of 0.77 microM and a relative standard deviation (RSD) of 2.6% for sulfide, 101 microM (SD = 3.5 microM, RSD = 3.5%) for the total of sulfite and sulfate and 20.1 microM (SD = 0.44 microM, RSD = 2.2%) for thiosulfate. Recoveries for sulfide, sulfite plus sulfate, and thiosulfate in hot-spring water samples using the proposed method were found to be quantitative.  相似文献   

4.
刘玉珍  于泓  张仁庆 《色谱》2012,30(4):384-390
建立了同时测定离子液体的阴离子三氟乙酸根、硫氰酸根、四氟硼酸根和三氟甲磺酸根的反相离子对色谱-直接电导检测方法。采用Diamonsil C18分离柱,以离子对试剂-苹果酸-乙腈水溶液为流动相,从流动相组成和色谱柱温度两方面讨论并确定了优化的色谱条件,即以0.15 mmol/L氢氧化四丁铵-0.099 mmol/L苹果酸-20%(v/v)乙腈混合水溶液(pH 6.5)为流动相,柱温25 ℃。在此条件下,三氟乙酸根、硫氰酸根、四氟硼酸根和三氟甲磺酸根离子均达到基线分离,且不受其他常见阴离子氟离子、氯离子、溴离子、硝酸根、硫酸根的干扰。三氟乙酸根、硫氰酸根、四氟硼酸根和三氟甲磺酸根离子的检出限(信噪比为3)分别为0.21、0.07、0.36、0.12 mg/L。将方法应用于测定离子液体中三氟乙酸根、硫氰酸根、四氟硼酸根和三氟甲磺酸根离子,加标回收率为95.0%~104.6%。该法简便、快速、灵敏度较高,可满足离子液体样品的检测要求。  相似文献   

5.
An analytical method was developed for the simultaneous determination of thiocyanate and iodide by reversed‐phase liquid chromatography with UV detection using imidazolium ionic liquids as mobile phase additives. The chromatographic behaviors of the two anions on a C18 column were studied and compared with four types of reagents including imidazolium ionic liquids, pyridinium ionic liquids, 4‐aminophenol hydrochloride and tetrabutylammonium as mobile phase additives. The effects of the concentrations of imidazolium ionic liquids, organic solvents and detection wavelength on separation and detection of the anions were investigated. The role of ionic liquids, retention rules and mechanisms were discussed. The separation of the anions was performed on the C18 reserved‐phase column using acetonitrile‐0.3 mmol/L 1‐amyl‐3‐methylimidazolium tetrafluoroborate (10:90, v/v) as mobile phase, with column temperature of 35°C, flow rate of 1 mL/min and detection wavelength of 210 nm. Under these conditions, the two anions can be completely separated within 6 min. The limits of detection were 0.05 mg/L. The method was applied for the determination of thiocyanate and iodide in ionic liquid samples and iodide drugs, and the spiked recoveries ranged from 97 to 101%. The method is simple, accurate and meets the requirements of quantitative analysis for thiocyanate and iodide.  相似文献   

6.
A novel method for determination of formaldehyde sulfoxylate,sulfite,thiocyanate,and thiosulfate in foodstuffs by ion chromatography separation with postcolumn derivation and UV detection has been developed.All species are separated at Dionex IonPac AG22A and AS22A with mobile phase of a mixture of 4.5 mmol/L sodium carbonate and 0.8 mmol/L sodium bicarbonate at a flow-rate of 1.0mL/min.The postcolumn derivation solution was 0.24%iodine in 0.2%phosphate acid and the detection wavelength was set at 288 nm...  相似文献   

7.
A method for the separation of the polythionates (SxO6(2-), x = 3-5) in gold thiosulfate leach solutions using ion-interaction chromatography with conductivity and ultraviolet (UV) detection is described. Polythionates were eluted within 18 min using an eluent comprising an acetonitrile step gradient at 0.0 min from 15% v/v to 28% v/v, 3 mM TBAOH, and 2.5 mM sodium carbonate, operated using a Dionex NS1-5 micron column with guard. The developed method was capable of separating the gold thiosulfate complex ion in standard solutions, but quantification of this species in realistic leach solutions proved impractical due to a self-elution effect that caused the gold peak to be eluted as a broad band. Detection limits for polythionates using a 10 microL injection volume ranged between 1-6 mg L(-1) (5-23 microM) for conductivity and 0.8-13 mg L(-1) (4-68 microM) for UV detection, based on a signal-to-noise ratio of 2. Calibration was linear over the ranges 5-2000, 10-2000 and 25-2500 mg L(-1) for trithionate, tetrathionate and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20 % m/v gold ore.  相似文献   

8.
The sequential simplex strategy has been used to optimize the mobile phase used for separation of inorganic anions by micellar chromatography on a C(18)- micro Bondapak column, with absorption detection at 230 nm. The amount of acetonitrile and the concentration of phosphate buffer (pH 6.0) were chosen for optimization. The optimum mobile phase was found to be 38% acetonitrile in 18.2 mmol L(-1) phosphate buffer (pH 6.0) containing 10 mmol L(-1) cetyltrimethylammonium bromide (CTAB); this optimum was achieved within seven experiments. The separation of the five anions (nitrite, nitrate, iodide, thiocyanate, and thiosulfate) was accomplished in 18 min.  相似文献   

9.
A new capillary electrophoresis (CE) method was developed for the rapid, simple and selective determination of thiosulfate, sulfide and sulfite species. The proposed method is based on the in-capillary derivatization of separated sulfur anions by mixing their zones with the iodine zone during the electrophoretic migration and direct UV detection of iodide formed. The optimal conditions for the separation and derivatization reaction were established by varying electrolyte pH, electrolyte counter-ion, concentration of iodine, and applied voltage. The optimized separations were carried out in 20 mmol/L Tris-chloride electrolyte (pH 8.5) using direct UV detection at 214 nm. All three sulfur species were well resolved in less than 4 min. The method gives repeatability comparable or even better than this obtained for sulfur anions using standard CE technique. The proposed CE system was applied to the monitoring of sulfur anions in spent fixing solutions during the electrolytic oxidation.  相似文献   

10.
Capillary electrophoresis (CE) was developed for the rapid and simple determination of thiosulfate and its oxidation products such as common polythionates, sulfite and sulfate. Direct and indirect UV detection techniques were investigated. The optimized separations of UV absorbing S2O3(2-), S4O6(2-), S5O6(2-) and S6O6(2-) anions were carried out in 5 mmol l(-1) (NH4)2SO4, 5 mmol l(-1) KH2PO4 electrolyte at pH 5.0, with direct UV detection at 214 nm. All analytes were well resolved in less than 4 min. Analysis of S2O3(2-), S4O6(2-), SO4(2-) and SO3(2-) ions can be performed in 5 mmol l(-1) H2CrO4, 1 mmol l(-1) hexamethonium hydroxide electrolyte neutralized with triethanolamine to pH 8.0, using indirect UV detection at 254 nm. However, the detection sensitivity for tetrathionate was poor. Other polythionates can not be detected at all because of their high absorbance even at 254 nm. The developed CE method was applied for the monitoring of sulfur species in spent fixing solutions during the electrolytic oxidation.  相似文献   

11.
Padarauskas A  Schwedt G 《Talanta》1995,42(5):693-699
A reversed phase ion pair chromatographic method for the simultaneous determination of Cr species and common anions on a C(18)-bonded stationary phase was developed by using acetonitrile-water (2:98 v/v) containing 1.0 mM tetrabutylammonium hydroxide and 0.5 mM trans-1,2-diaminecyclohexane-N,N,N',N'-tetraacetic acid (DCTA) at pH 6.5 as mobile phase and UV-detection at 210 nm. Chromatographic parameters were optimized for separation of Cr(III)-DCTA complex, chromate and other anions. The detection limits were found as 8 ng/ml for Cr(III) and 35 ng/ml for Cr(VI). Under the optimum conditions, most other ions did not interfere. The method can be applied to separate a number of common anions simultaneously with the separation of Cr(III) and Cr(VI).  相似文献   

12.
The analysis of sulfur species in complex matrices, like environmentally related samples, requires selective and sensitive as well as robust determination methods. As many as possible different anions need to be quantified in a reasonable analysis time. Besides ion chromatography, capillary electrophoresis has proven to be a very efficient technique for the separation and determination of ionic compounds. With the advantages of less sample and solvent consumption compared to conventional LC, short separation time, inexpensive and robust capillaries, CE was used to separate the anions sulfate, sulfite, thiosulfate, thiocyanate and sulfide. Detection and injection modes and the composition of the separation buffers have been varied to find the most suitable conditions. Conductivity detection after electrokinetic sample injection and improvement of calibration linearity allowed the determination of sulfur containing anions with low limits of detection (8 to 50 micrograms/l). The developed CE method was applied to the analysis of water from an open-pit mining lake.  相似文献   

13.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

14.
Summary A sensitive ion-exclusion chromatographic method has been developed for determination of oxalate, thiosulfate, and thiocyanate. The method is based on separation of these anions on a polymethacrylate-based, weakly acidic cation-exchange resin (TSKgel OApak-A) and detection by means of a glassy carbon (GC) electrode electrochemically modified with polyvinylpyridine (PVP), palladium, and iridium oxide (PVP/Pd/IrO2). The electrochemical behavior of oxalate, thiosulfate, and thiocyanate at this chemically modified electrode (CME) have been investigated by cyclic voltammetry. The results indicated that electrocatalytic oxidation of these anions by the electrode was efficient and that the sensitivity, stability, and lifetime of the electrode were relatively high. Combined with ion-exclusion chromatography the PVP/Pd/IrO2 electrode was used as the working electrode for amperometric detection of these anions. All linear ranges were over two orders of magnitude and detection limits, defined asS/N=3, were 9.0×10−7 mol L−1 for oxalate, 6.7×10−7 mol L−1 for thiosulfate, and 5.6×10−7 mol L−1 for thiocyanate. Correlation coefficients were all>0.998. Coupled with microdialysis sampling the method has been successfully applied to the determination of oxalate, thiosulfate, and thiocyanate in urine.  相似文献   

15.
A high-performance liquid chromatographic method using refractive index detection for the determination of glycogen in sea urchin (Paracentrotus lividus) gonads is developed. After alkaline digestion with sodium carbonate, samples are adjusted to pH 4.6 with citric acid and incubated with amyloglucosidase to hydrolyze the glycogen. The resulting glucose is determined using a Spherisorb NH2 column as the stationary phase and an acetonitrile-water mixture (80:20, v/v) as the mobile phase. The relative standard deviation (%) was 3.57, the limit of detection was 40.1 microg/mL, and the recovery percentage was 97.2%.  相似文献   

16.
李善茂  李伟  岳丽君  左伯莉 《色谱》2005,23(5):545-547
二苯氯胂和二苯氰胂是刺激性毒剂,在环境中易于降解,其产物苯胂酸、苯胂氧、二苯胂酸、氧联双二苯胂和三苯胂比较稳定,对环境危害大。建立了同时测定这5种含胂产物的反相高效液相色谱方法,选择了最佳色谱条件,提供了各组分的紫外光谱图。5种化合物的线性范围分别为8~30,5~40,20~4000,120~8000,1~60 mg/L,检测限分别为0.1,0.1,0.2,10,0.1 mg/L。对实际环境样品进行了分析,结果较好。  相似文献   

17.
Ion-pair chromatographic technique was developed for the rapid and simple determination of the main contaminants (bromide, iodide, sulphite, thiosulphate, thiocyanate, iron(III)-EDTA chelate, free EDTA, hydroquinone and phenidone) in spent photographic solutions. Free EDTA was converted into stable Ni(II)-EDTA chelate prior to analysis. The optimal mobile phase conditions were established by varying the concentrations of tetrabutylammonium (TBA) phosphate and acetonitrile, pH and ionic strength. Separation of five inorganic anions, two metal chelates and two neutral compounds was accomplished in about 30 min using a mobile phase containing 7.5 mmol/L TBA-phosphate, 10 mmol/L NaCl (pH 6.5) and 20% (v/v) acetonitrile. The detection limits (UV detection at 210 nm) ranged from 0.4 μmol/L for phenidone to 8 μmol/L for sulphite with a linearity of 2–2.5 orders of magnitude. The method was applied to the rapid monitoring of spent photographic solutions before and after decomposition. The recovery tests established for two samples were within the range 95–103%.   相似文献   

18.
Degradation by silver permits determination of the distribution of activity inside the labelled molecule for thiosulfate and for the polythionates. When single salts are present, the reactions can be carried out either in solution or on the pherogram. In comparison, for mixtures of sulfur anions, it is necessary to perform previously a high voltage inonophoretic separation. The cutout zone of a definite anion is put on a new pherogram and the degradation by silver is carried out. The results correspond within the accuracy of measurement to the theoretical values.  相似文献   

19.
A reliable and sensitive HPLC method was developed for the quantitation of tadalafil transdermal permeation through human skin. An RP column with UV detection at 290 nm was used for chromatographic separation at ambient temperature. The mobile phase was acetonitrile-water containing 20 mM pH 7 phosphate buffer (35/65, v/v) with a flow rate of 1.0 mL/min. The LOQ achieved was 1 ng/mL, and the calibration curve showed good linearity over the concentration range of 5-2000 ng/mL for tadalafil, with a determination coefficient (R2) of 0.998. The RSD values of intraday and interday analyses were all within 7%. Parameters of validation proved the precision of the method; this validated method was applied for the determination of tadalafil in transdermal permeation and drug deposition in human skin studies.  相似文献   

20.
A sensitive and specific high performance liquid chromatographic method for the determination of sulfide, sulfite, and thiosulfate was established. Inorganic sulfur anions were converted into fluorescent derivatives with monobromobimane. The derivatives were separated on a coupled column chromatography with a reversed-phase octadecyl silica column connected with a weakly basic anion exchanger column by isocratic elution with acetic acid solution (pH 3)-acetonitrile (13:3, v/v) containing 25 mM NaClO4. The method was applied to the determination of bound sulfide and sulfite and thiosulfate in normal human serum. Thiosulfate could be determined directly by use of an ultrafiltered sample. For the determination of bound sulfide and sulfite, the pretreatment step with continuous flow gas dialysis was effective for the sample after releasing sulfide and sulfite by reduction with dithiothreitol. The limits of quantification by the present method were 0.05 microM for thiosulfate, 0.5 microM for bound sulfide, and 0.2 microM for bound sulfite.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号