首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Determination of ppm levels of B in 21 igneous and sedimentary rocks of the Japanese geochemical reference samples prepared by the Geological Survey of Japan (GSJ) has been performed by neutron-induced prompt γ-ray analysis (PGA) using cold and thermal guided neutron beams of the JRR-3M. Owing to the Doppler broadened γ-ray line of B 478 keV, many elements such as Na, Ni, Cl and so on showed spectral interference in the determination of B. The interference was corrected by computer fitting and a reference peak method. The analytical results obtained by the present method almost agreed with the GSJ values recommended in 1994 within the standard deviation of the recommended values. Sodium contents determined by the PGA in the reference rock samples are also reported.  相似文献   

2.
A sorbent extraction procedure for Pb(II), Cu(II), Ni(II), and Fe(III) ions on single-walled carbon nanotube disks has been established. Analyte ions were converted to 2-(5-bromo-2-pyridylazo)-5-diethylamino-phenol chelates, then adsorbed on the disk. Adsorbed chelates were easily desorbed from the disk by using 10 mL 2 M HNO3. The various analytical parameters, including pH and reagent amounts that were effective for the recoveries of the analytes on nanotube disks, were optimized. The influence of matrix ions was also studied. The LOD values based on 3sigma were in the 0.3-4.6 microg/L range. Validation of the proposed SPE procedure was carried out by the determination of analytes in certified reference materials (TMDA-54.4 fortified lake water and HR-1 Humber River sediment). Spiking and recovery experiments for the analyte ions in real samples gave good results. Application of the procedure was illustrated by the determination of analyte contents in some animal feeds and water samples from Turkey.  相似文献   

3.
The paper describes a method of radioactivation analysis for the determination of indium, copper and nickel. In the determination of indium, ordinary and displacement substoichiometries were applied for glassmaking materials while ordinary substoichiometry was applied for NBS standard reference materials. Copper and nickel in glassmaking materials and NBS standard reference materials were also determined by the displacement and ordinary substoichiometries. Indium contents in glassmaking materials by the two methods agreed with each other. The analytical results of indium, copper and nickel in NBS' SRM were also in good agreement with published values and certified values by NBS.  相似文献   

4.
 Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used as a powerful multielement analytical method for trace analysis of geological glasses which are useful as reference materials for geochemical in-situ microanalytical work. The quantification of the analytical results was carried out using the BCR-2G and NIST 612 glass standard reference material (SRM). The experimentally determined relative sensitivity coefficients (RSC) for both SRMs vary between 0.2 and 3 for most of the elements, with increasing mass an increasing of relative sensitivity coefficients was observed. The relative standard deviation (RSD) for determination of trace element concentration of most elements (N=3) are between 2 and 10%. The determination of trace elements in various geological glasses by LA-ICP-MS yielded a good agreement with the reference values and those results of other trace analytical methods. Received October 15, 1999. Revision April 14, 2000.  相似文献   

5.
中药材三七中皂苷类成分的近红外光谱快速无损分析新方法   总被引:23,自引:0,他引:23  
提出了用近红外漫反射光谱快速无损测定三七中皂苷类成分的新方法采用 HPLC分析了中药材三七固皂昔R_1,人参皂苷Hg_1,Rb_1和Rd的含量,用吸附树脂 比色法测定了三七总皂苷(PNS)的含量,共获得R_1,Bg_1,Rb_1,Rd,PNS的含 量范围分别为1,58-5.08,21,68-46.13,11.46-40.41粉.在3500-1100cm~(-1) 扫描样品,以交叉验证误差均方根(RMsECV)为指标,通过筛选,近红外波段和光 谱预处理方法.采用偏最小二乘算法建立了近红外光谱与5个组分PHLC分析值之间 的校正模型,预测了8个未知样本.R_1,Rg_1,Rb_1,Rd及PNS校正模型的RMSECV 分别为0.40,1.47,1.94,0RMSEP分别为0.53,3.15,2.14,0.70,9.03. 该方法快速无损,结果可靠,为中药材复杂体系中化学组分的测定提供了新的绿色 分析手段.  相似文献   

6.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

7.
The determination of extractable trace metal contents in soil using single extraction procedures is currently performed in many laboratories to assess the bioavailable metal fraction (and related phytotoxic effects) and the accessability to the environment (e.g. contamination of ground waters). Owing to the need for validation of the extraction schemes used and of the analytical techniques, the EC Measurements and Testing Programme (formerly BCR) has organized a project for improving the quality of determination of extractable trace metal contents in soil, the first step being an interlaboratory study to adopt common extraction procedures and the second being a certification campaign to certify two soils for their extractable trace element contents following these procedures. This paper gives a brief overview of the project organisation and describes the preparation, homogeneity and stability studies of two soil candidate reference materials (sewage sludge-amended and terra rossa soils).  相似文献   

8.
X射线荧光光谱法测定化探样品中主、次和痕量组分   总被引:21,自引:0,他引:21  
采用粉末样品压片制样,用PW2440X射线荧光光谱仪对化探样品中氯、溴、硫、氧化钠、氧化镁、三氧化二铝、二氧化硅、磷、氧化钾、氧化钙、钛、锰、三氧化二铁、钴、铌、锆、钇、锶、铷、铅、钍、锌、铜、镍、钒、铬、钡、镧、铈、钕、钪、镓、砷、铪等34个组分进行测定。讨论了微量元素的背景选择和谱线重叠校正及氯测定的问题。使用经验系数法和康普顿散射线作内标校正基体效应,经标准物质检验,分析结果与标样值吻合,用GBW 07308国家一级标准物质作精密度试验,统计结果RSD(n=12)除砷、钒、镍、铜〈6.0%,溴、硫、铈、铪、钕、钪、氧化钠、镧、铬、钴和钍〈14.0%以外,其余各组分均小于3.0%。  相似文献   

9.
Fernandes RN  Reis BF 《Talanta》2002,58(4):729-737
A flow system for the simultaneous determination of ammonium and phosphate in river water at the mug ml(-1) level employing a low expensive LED-based photometer is described. The manifold of the flow system comprised four analytical pathways containg a set of three-way solenoid valves and an automatic injector commutator. The signal measurements of both analytes were carried out using two LED-based photometers attached to the flow cells. A microcomputer running a programme written in quickbasic 4.5 provided facilities to control the system and to carry out simultaneously two analytical procedures also performing data acquisition. For the determination of ortho-phosphate the method based on reaction with molybdate and ascorbic acid was employed, while for ammonium the method based on reaction with hypochlorite and salicylic acid was selected. The four-pathway structure of the manifold allowed the sample incubation time to be increased to 130 s to permit the reaction to occur without a decrease in sample throughput. The usefulness of the system was ascertained by analyzing a set of water samples. Applying the paired t-test to results obtained employing reference methods, no significant difference at the 95% confidence level was observed for both analytes. Other profitable features such as an analytical throughput of 112 analyte determination per hour; relative standard deviations of 1.1 and 0.7% (n=6) ammonium and phosphate, respectively, reagent consumption of 0.3 mg ammonium molybdate, 0.75 mg salicylic acid, 3.3 mg ascorbic acid and sodium hypochlorite per determination; detection limits of 7.0 mug l(-1) NH(4)(+) and 17.0 mug l(-1) PO(4)(3-) were also achieved.  相似文献   

10.
建立了两种以火试金预浓集为基础的、可用于准确测定铂族元素的方法;中子活化法和电感耦合等离子体质谱法。讨论了它们的分析检出限、准确度及其适应性。并用这两种方法测定了5种候选地质参考物质中铂族元素的含量。  相似文献   

11.
The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an "integrated trap") was investigated. A dramatic improvement in detection limit was achieved compared with that obtained using anyone of the above atom trapping techniques separately. The concentration detection limits were 4 and 3 ng ml(-1) for As and Se, respectively. For a 2 min in situ preconcentration time, sensitivity enhancement, compared to FAAS, were 875 and 833 folds for As and Se, respectively, using hydride generation, atom trapping technique. The sensitivity can be further improved by increasing the collection time. The relative standard deviations (RSDs) are of the order of 5 - 9% for this hyphenated technique. The designs studied include slotted tube, water-cooled single silica tube and integrated atom trap. The accuracy was assessed by analyses of NRCC DOLT-2 (Dogfish Liver) and NIST SRM 1648 (Urban Particulate Matter) reference materials. The measured As and Se contents in two reference materials were in satisfactory agreement with the certified values.  相似文献   

12.
The experimental conditions for the determination of platinum, palladium and rhodium by graphite furnace atomic absorption spectrometry (GFAAS) are re-assessed. A certified material (BCR-723) was used as a working sample and analyzed using various extraction and atomization procedures in order to find the optimal experimental conditions that enable the quantitative and reproducible detection of platinum, palladium and rhodium in environmental matrices. Evidently, literature observations regarding the atomization conditions were proven fairly adequate. However, the provision of the optimum extraction conditions revealed several parameters that lie behind the reported uncertainties. The appropriate combination between extraction conditions and atomization programs afforded a considerable improvement in the recoveries and analytical features of platinum, palladium and rhodium determination with GFAAS. Cross-examination of the analytical data with various CRMs (certified reference materials) was used to validate the robustness of the method in heterogeneous matrices bearing different element levels. Under the optimum experimental conditions the method permits the determination at concentrations as low as (LOD(3S/N)) 1.9 ng g(-1), 0.45 ng g(-1) and 0.6 ng g(-1) for Pt, Pd and Rh, respectively affording recoveries in the range of 93-101%. The method was successfully applied to the assessment of Pt, Pd and Rh accumulation in real road dust and soil samples in Greece.  相似文献   

13.
A procedure is proposed for the direct determination of manganese and iron in wine employing fast sequential flame atomic absorption spectrometry and the reference element technique to correct for matrix effects. Cobalt, silver, nickel and indium have been tested as reference elements. The results demonstrated that cobalt and indium at a concentration of 2 and 10mgL(-1) were efficient for quantification of manganese and iron, respectively. Under these conditions, manganese and iron could be determined with quantification limits of 27 and 40microg L(-1), respectively. The proposed method was applied to the determination of manganese and iron in 16 wine samples. The content of manganese varied from 0.78 to 2.89mgL(-1) and that of iron from 0.88 to 9.22mgL(-1). The analytical results were compared with those obtained by inductively coupled plasma optical emission spectrometry after complete mineralization using acid digestion. The statistical comparison by a t-test (95% confidence level) showed no significant difference between the results.  相似文献   

14.
Due to be able to migrate or leach from food packaging materials into the foods and/or beverages, development of a new, sensitive and selective analytical methods for low levels of antimony as a food contaminant is of great importance in terms of food safety. In this context, an ultrasonic-assisted cloud point extraction method was developed for the preconcentration and determination of antimony as Sb(III) using 4-(2-thiazolylazo)resorcinol (TAR) and 2-(2-thiazolylazo)-p-cresol (TAC) as chelating agents and sodium dodecyl sulfate as signal enhancing agent at pH 6.0 and mediated by nonionic surfactant, t-octylphenoxypolyethoxyethanol by flame atomic absorption spectrometry. Using the optimized conditions, the calibration curves obtained from Sb(III) with TAR and TAC were linear in the concentration ranges of 0.5–180 and 1–180 μg L?1 with detection limits of 0.13 and 0.28 μg L?1, respectively. The precision (as relative standard deviations, RSDs) was lower than 3.9 % (25 and 100 μg L?1, n: 6). The method accuracy was validated by the analysis of two standard reference materials. The results obtained were statistically in a good agreement with the certified values at 95 % confidence limit. The method has successfully been applied to the determination of Sb(III) and total Sb in selected beverages, milk and fruit-flavored milk products before and after pre-reduction of Sb(V) to Sb(III) with a mixture of KI/ascorbic acid in acidic media. The Sb(V) contents of samples were quantitatively calculated from analytical difference between total Sb and Sb(III) levels.  相似文献   

15.
A flow-through optosensor with solid phase UV spectroscopic detection is proposed for the direct determination of single antioxidants, namely butylated hydroxyanisole (BHA) and n-propyl gallate (n-PG), without previous derivatization. The methods are based on the transient retention behaviour of these compounds in a flow-through cell packed with C-18 silica using ethanol-water mixtures as a carrier, and on the intrinsic absorbance monitored at 290 and 283 nm, respectively. After recording the analytical signal, the antioxidants were easily and quickly desorbed from the solid support by the same carrier. For BHA, calibration graphs were linear over the range 1.0-300.0 mg L-1 using area as the analytical parameter. The relative standard deviation (RSD) was between 0.5 and 1.6%. For n-PG, calibration graphs were linear over the range 1.0-300.0 mg L-1 in area and the RSD was between 1.4 and 1.5%. The methods were applied to the determination of these antioxidants in several food and cosmetics samples, and were validated using the standard additions method and an HPLC reference method.  相似文献   

16.
An analytical procedure fit for the simultaneous determination of copper (II), chromium(VI), thallium(I), lead(II), tin(II), antimony(III), and zinc(II) by square wave anodic stripping voltammetry (SWASV) in three interdependent environmental matrices involved in foods and food chain as meals, cereal plants and soils is described. The digestion of each matrix was carried out using a concentrated HCl-HNO3-H2SO4 (meals and cereal plants) and HCl-HNO3 (soils) acidic attack mixtures. 0.1 mol/L dibasic ammonium citrate pH 8.5 was employed as the supporting electrolyte. The voltammetric measurements were carried out using, as working electrode, a stationary hanging mercury drop electrode (HMDE) and a platinum electrode and an Ag/AgCl/KClsat electrode as auxiliary and reference electrodes, respectively. The analytical procedure was verified by the analyses of the standard reference materials: Wholemeal BCR-CRM 189, Tomato Leaves NIST-SRM 1573a and Montana Soil Moderately Elevated Traces NIST-SRM 2711. For all the elements in the certified matrix, the precision as repeatability, expressed as relative standard deviation (Sr %) was lower than 5%. The accuracy, expressed as percentage relative error (e %) was of the order of 3-7%, while the detection limits were in the range 0.015-0.103 microg/g. Once set up on the standard reference materials, the analytical procedure was transferred and applied to commercial meal samples, cereal plants and soils samples drawn in sites devoted to agricultural practice. A critical comparison with spectroscopic measurements is also discussed.  相似文献   

17.
A new analytical voltammetric procedure for the simultaneous determination of copper(II), lead(II), cadmium(II), zinc(II), chromium(VI), and manganese(II) in two kinds of dialysis fluid (peritoneal and haemodialysis fluids) is described. The voltammetric measurements were performed using, as working electrode, a stationary mercury electrode, and a platinum electrode and a Agmid R:AgClmid R:KCl ((sat.)) electrode as auxiliary and reference electrodes, respectively, employing 0.1 mol L(-1) dibasic ammonium citrate solution pH 6.9 as supporting electrolyte. For all the elements, the accuracy, expressed as relative recovery R%, was very satisfactory being in the range 94-105%, the precision, expressed as relative standard deviation s(r)%, was lower than 6%, while the limits of detection were of the order of a few units of microg L(-1). The analytical voltammetric procedure has been validated by comparison with spectroscopic (graphite furnace atomic absorption spectroscopy, GFAAS) measurements.  相似文献   

18.
Gao Z  Li P  Zhao Z 《Talanta》1991,38(10):1177-1184
The utility of carbon-paste electrodes modified with 2,2'-bipyridyl and Nafion for the differential pulse voltammetric determination of iron(II) in aqueous medium is demonstrated. The method is based on formation of the 2,2'-bipyridyl complex of iron(II) and its accumulation by the Nafion. The differential pulse voltammetric response of the accumulated complex is used as the analytical signal. The response was evaluated with respect to carbon-paste composition, preconcentration time, pH, iron(II) concentration and other variables. A 3-min accumulation period permits measurement of iron(II) down to 10(-8)M, and a relative standard deviation of 3.8% for 2 x 10(-6)M iron(II). Rapid and convenient chemical renewal allows use of a single modified carbon-paste electrode in multiple analytical measurements over several days. The proposed procedure was applied to the determination of iron in certified standard reference materials and trace iron in natural waters.  相似文献   

19.
Sun YC  Mierzwa J  Lan CR 《Talanta》2000,52(3):417-424
A reliable and very sensitive procedure for the determination of trace levels of molybdenum in seawater is proposed. The complex of molybdenum with 8-hydroxyquinoline (Oxine) is analyzed by cathodic stripping square-wave voltammetry based on the adsorption collection onto a hanging mercury drop electrode (HMDE). This procedure of molybdenum determination was found to be more favorable than differential pulse cathodic stripping voltammetry because of inherently faster scan rate and much better linearity obtained through the one-peak (instead of one-of-two peaks) calibration. The variation of polarographic peak and peak current with a pH, adsorption time, adsorption potential, and some instrumental parameters such as scan rate and pulse height were optimized. The alteration of polarographic wave and its likely mechanism are also discussed. The relationship between peak current and molybdenum concentration is linear up to 150 mug l(-1). Under the optimal analytical conditions, the determination limit of 0.5 mug l(-1) Mo was reached after 60 s of the stirred collection. The estimated detection limit is better than 0.1 mug l(-1) of Mo. The applicability of this method to analysis of seawater was assessed by the determination of molybdenum in two certified reference seawater samples (CASS-2 and NASS-2) and the comparison of the analytical results for real seawater samples (study on a vertical distribution of Mo in the seawater column) with the results obtained by Zeeman-corrected electrothermal atomization atomic absorption spectrometry (Zeeman ETAAS). A good agreement between two used methods of molybdenum determination was obtained.  相似文献   

20.
Peak area was used for the simultaneous determination of copper(II), lead(II), cadmium(II), and nickel(II) in environmental matrixes by differential pulse voltammetry. The voltammetric measurements were performed with a conventional 3-electrode cell and an ammonia-ammonium chloride buffer, pH 9.1, as the supporting electrolyte. The analytical procedure was verified first in aqueous reference solutions and later by analysis of the standard reference materials Estuarine Sediment BCR-CRM 277 and River Sediment BCR-CRM 320. The precision and accuracy of the method, expressed as the relative standard deviation and the relative error, respectively, were <5% in all cases; the detection limit for each element under the experimental conditions used was in the range 1-5 microg/L. In the case of mutual interference between neighboring elements, an analytical procedure is proposed that is based on the standard additions technique, which allows the resolution of the overlapping voltammetric peaks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号