首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
The elements Mn and V were determined by INAA in about 5 mg and 100 mg aliquots of NIST SRM 1648 to elucidate discrepancies between our previous results for the 0.5 mg to 15 mg aliquots and the NIST certified and/or information values. Simultaneously, other NIST SRMs 1633a, 2704, and BCR CRMs 038, 101 and 143 were also analyzed. Special attention was given to evaluating and minimizing uncertainties of all steps of analysis. Our results compared very well with the respective certified and/or information values (if available) of all SRMs and CRMs studied, except for NIST SRM 1648. For this SRM we have found significantly lower results than the NIST values which suggests that the NIST values are positively biased by about 10%. A new value for V in BCR CRM 143 was also obtained.  相似文献   

2.
    
Summary Instrumental and radiochemical neutron activation analysis results are reported for 28 elements in NIST SRM-1515 Apple Leaves and NIST SRM-1547 Peach Leaves which were analyzed as intercomparison samples before their certification. Results for NIST SRM-1571 Orchard Leaves and Bowen's Kale analyzed as control samples are also given. The very good accuracy of INAA and RNAA is shown by the close comparison of the present results with the certified, information, and literature data on the materials analyzed.  相似文献   

3.
Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma-mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.  相似文献   

4.
Accurate measurements of bromine contents in plastic samples were made by the direct comparator instrumental neutron activation analysis (INAA). Individual factors affecting the measurements were comprehensively evaluated and compensated, including the volatility loss of bromine from standard comparators, the background bromine level in the filter papers used for preparation of the standard comparators, nuclear interference, γ-ray spectral interference and the variance among replicates of the samples. Uncertainty contributions from those factors were thoroughly evaluated and included in the uncertainty budgeting of the INAA measurement. 81Br was chosen as the target isotope, and the INAA measurements for bromine were experimentally confirmed to exhibit good linearity within a bromine content range of 10–170 μg. The established method has been applied to the analysis of eight plastic samples: four commercially available certified reference materials (CRMs) of polyethylene and polystyrene and four acrylonitrile butadiene styrene (ABS) samples prepared as the candidate reference materials (KRISS CRM 113-01-012, -013, -014 and -015). The bromine contents of the samples were calculated at three different γ-ray energies and compared, showing good agreement. The results of the four CRMs also showed good consistency with their certified values within the stated uncertainties. Finally, the bromine contents of the ABS samples were determined with expanded uncertainties (at a 95% level of confidence) between 2.5% and 5% in a bromine content range of 25–900 mg kg−1.  相似文献   

5.
The objective of this work was to compare the results obtained by the relative INAA and k 0-INAA methods for the same input parameters (sample mass, nuclear data, net peak area for the same gamma line and the same measurement and same cooling and measurement times). In total eight environmental soil and sediment reference materials (RM) or certified reference materials (CRM) from different producers were analysed. In this work only the recommended or certified values were considered, allowing comparison of the two methods for 30 elements. The results point out that k 0-INAA possesses superior qualities compared to relative INAA, being insensitive to flux gradients, and independent of recommended/certified values in RMs/CRMs, often used as standards in relative INAA.  相似文献   

6.
Multielement analyses of environmental reference materials have been performed using existing certified reference materials (CRMs) as calibration standards for inductively coupled plasma–mass spectrometry. The analyses have been performed using a high-performance methodology that results in comparison measurement uncertainties that are significantly less than the uncertainties of the certified values of the calibration CRM. Consequently, the determined values have uncertainties that are very nearly equivalent to the uncertainties of the calibration CRM. Several uses of this calibration transfer are proposed, including, re-certification measurements of replacement CRMs, establishing traceability of one CRM to another, and demonstrating the equivalence of two CRMs. RM 8704, a river sediment, was analyzed using SRM 2704, Buffalo River Sediment, as the calibration standard. SRM 1632c, Trace Elements in Bituminous Coal, which is a replacement for SRM 1632b, was analyzed using SRM 1632b as the standard. SRM 1635, Trace Elements in Subbituminous Coal, was also analyzed using SRM 1632b as the standard.  相似文献   

7.
Nickel contents in different finished product alloys were determined using a k 0-based internal monostandard instrumental neutron activation analysis (IM-INAA) method. Five stainless steels (SS) and three high nickel alloys were analyzed by IM-INAA. BCS CRMs 225/1 (low alloy steel) and 466 (austenitic SS) and NIST SRM 247 (high Ni alloy) were analyzed to evaluate the accuracy of the method. The results of CRMs and SS were found to be in good agreement with certified or specified values. The Ni contents in the high nickel alloys were also determined by relative method of NAA for verification. Nickel contents in BCS CRM 466 and SS 316M were determined by UV–Visible spectrophotometry and the values were found to be in good agreement with IM-INAA results.  相似文献   

8.
Trace amounts of transition elements (Co, Cr, Cu, Fe, Mn and V) and other seven elements in optical waveguide samples were determined by INAA. The contents of impurities in ultra-pure materials are less than those of high-purity materials and of G.R. grade. The increase of contamination of trace transition elements and iridium from furnace or crucible are observed in the production of optical glass fibers. Up to seventeen elements were determined in five NBS biological standard reference materials: Oyster Tissue: SRM-1566, Brewers Yeast: SRM-1569, Spinach: SRM-1570, Orchard Leaves: SRM-1571 and Tuna Fish, and in four Japanese biological standard reference materials: Tea Leaves B&C, Pepperbush and Shark Meat. The analytical results in NBS and Japanese standard reference materials are in good agreement with published values and certified values by NBS.  相似文献   

9.
Determination of selenium in soil by hydride generation AAS   总被引:2,自引:0,他引:2  
Hydride generation AAS was applied for the determination of total selenium in soil. The influence of various anions and cations present in the sample solution on the generation of selenium hydride was investigated. Special attention was paid to the wet oxidation procedure for the sample dissolution. The proposed procedure involves microwave sample preparation by using a mixture of H2O2/HNO3/H2SO4. The accuracy of the procedure was checked by the analysis of the standard reference material Buffalo River Sediment (SRM-2704, NIST). Satisfactory agreement of the results obtained with the values reported was achieved. The detection limit of the procedure was 25 ng Se/g of soil. The relative standard deviation of the measurements varied from 5.5% for SRM-2704 up to 10% for the real soil samples. Received: 20 January 1997 / Revised: 24 February 1997 / Accepted: 1 March 1997  相似文献   

10.
Summary The great usefulness of reference materials, especially ones of certified elemental composition, is discussed with particular attention devoted to their use in instrumental neutron activation analysis (INAA) work. Their use, including both certified and uncertified values, in calculations made by the INAA Advance Prediction Computer Program (APCP) is discussed. The main features of the APCP are described, and mention is made of the large number of reference materials run on the APCP (including the new personal computer version of the program), with NBS Oyster Tissue SRM-1566 used as the principal example.  相似文献   

11.
Concentrations of 35 elements in Chinese Standard Rocks (GSR-1 to GSR-3) and Soils (GSS-1 to GSS-8) have been measured with INAA using the SLOWPOKE reactor. At the same time, the U. S. NBS reference standards: SRM-1632a (Bituminous Coal), SRM-1633a (Coal Fly Ash) and SRM-1646 (Estuarine Sediment) were also analyzed in order to cross-check the accuracy of this method. The results obtained indicate that the reproducibility of the method is satisfactory for most of the elements, namely the precision in general, is better than ±10%. Comparison of our values for NBS SRM-1632a, 1633a and 1646 with the certified values of NBS or with values cited in the literature indicates good agreement. The results were found to be accurate within ±10% error of the established results.  相似文献   

12.
Levels of essential and toxic trace elements in six marine species greatly in demand in the international market (canned pink clams, razor clams, clams, king crab, sardines, and frozen albacore tuna fish) were studied. A special laboratory adequately equipped for handling and preparing biological materials, is described. The elements As, Br, Na, Se, Hg, Cr, Fe, Zn and Rb were determined by INAA, while copper and cadmium content were determined using RNAA. Significant differences were found on comparing the contents of some toxic elements in mollusk and other samples of marine food. Various certified reference materials (CRMs) of the IAEA, NIST and NIES were analyzed for quality assurance purposes.  相似文献   

13.
A modified three-step sequential extraction procedure for the fractionation of heavy metals, proposed by the Commission of the European Communities Bureau of Reference (BCR) has been applied to the Slovak reference materials of soils (soil orthic luvisols, soil rendzina and soil eutric cambisol), which represent pedologically different types of soils in Slovakia. Analyses were carried out by flame or electrothermal atomic absorption spectrometry (FAAS or ETAAS). The fractions extracted were: exchangeable (extraction step 1), reducible-iron/manganese oxides (extraction step 2), oxidizable-organic matter and sulfides (extraction step 3). The sum of the element contents in the three fractions plus aqua-regia extractable content of the residue was compared to the aqua-regia extractable content of the elements in the origin soils. The accuracy obtained by comparing the determined contents of the elements with certified values, using BCR CRM 701, certified for the extractable contents (mass fractions) of Cd, Cr, Cu, Ni, Pb and Zn in sediment following a modified BCR-three step sequential extraction procedure, was found to be satisfactory.  相似文献   

14.
Purity certified reference materials (CRMs) are playing a key role in metrological traceability, because they form the basis for many traceability chains in chemistry. Recently, the National Metrology Institute of Japan (NMIJ) has developed two purity CRMs for creatinine (NMIJ CRM 6005-a) and urea (NMIJ CRM 6006-a), because the concentrations of these two compounds are frequently measured in clinical laboratories for monitoring the renal functions. In the certification of purity CRMs, it is essential that the materials have been thoroughly characterized for purity, and the purity should preferably be determined directly by a primary method of measurements. In the development of these two CRMs, we used the purified materials as candidates. The certified values were assigned based on the results of two different methods; acidimetric titration and nitrogen determination by the Kjeldahl method. Since both methods cannot distinguish some impurities from the target compounds, major impurities in the candidate materials were also identified, quantified, and subtracted. These CRMs can provide a traceability link between routine clinical methods and SI units. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

15.
In this paper the impact of the uncertainty in the elemental composition of the certified reference material (CRM) used for absolute efficiency calculations in gamma spectrometry is investigated. The method involved the use of semi-empirical modeling using solid angle concepts. The samples involved were a standard Jamaican soil, four bauxite reference samples from NIST and a standard ICRU reference material configuration simulating the calibrating CRM. The results indicate that at gamma energies below 60 keV, the impact on the bauxite reference samples and local soil samples resulted in errors up to 43 and 70 % respectively when the elemental composition of the efficiency calibrating reference sample was ignored. A set of equations for correcting the errors introduced were developed. The modeling of a theoretical soil type validated the process of ashing soils for low energy gamma spectrometry due to the extremely high errors introduced by the element carbon.  相似文献   

16.
Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg−1. In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. Figure Preparation and certification processes of the mineral oil CRMs (example shown is polychlorinated biphenyls in insulation oil, high/low concentrations) Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

17.
A method was validated for the direct determination of As(III) and As(V) in water samples by ion chromatography/inductively coupled plasma-mass spectrometry. Sample preservation required only dilution with a mobile phase containing a sufficient amount of ethylenediaminetetraacetic acid and acetic acid. Analyses of 6 certified reference materials (CRMs) of various water matrixes, including seawater, demonstrated good method accuracy. The matrixes included 2 natural water samples [National Institute of Standards and Technology Standard Reference Material (NIST SRM) 1643e and NIST SRM 1640], 1 fortified standard solution (TMDA-64), 1 fortified water sample (TM-DWS), and 2 seawater samples (CASS-4 and NASS-5). The sum of As(III) and As(V) in each CRM agreed with the respective certified value for the total amount of As within its stated uncertainty. Quantitative recoveries (96.7-102.1%) were obtained. Satisfactory results were achieved for intraday repeatability [relative standard deviation (RSD = 0.3-5.1%] and interday precision (RSD = 0.7-4.1%). In the study of fortified blanks and fortified CRMs, quantitative recoveries of As(III) and As(V) (92.5-102.6%) were obtained. Interconversion of As(III) and As(V) was not observed under the conditions of sample preservation. International comparability of analytical results was demonstrated by the analysis of 2 interlaboratory proficiency test samples, NY7011 and NY8511, from the New York State Department of Health.  相似文献   

18.
The environmental CRMs currently available from NRC Ottawa comprise four natural waters for trace elements, four biological tissues for trace elements and methylmercury, three marine sediments for major and trace elements (one sediment has certified values for butyltins) and one fish tissue for organochlorines (PCBs, dioxins). Although significant effort has been expended to maintain this suite of materials, several new initiatives have also recently been completed or are in progress. The certified value for arsenobetaine in Dogfish Muscle CRM DORM-2 has been established. The certification approaches, as well as the studies to determine extraction efficiency of this organoarsenic compound, are presented. A stability study has been completed for Hg in a natural water sample and plans are underway for production of a CRM. Assessment of micronutrient stability in seawater for the purposes of CRM production is continuing and progress on this initiative is discussed.  相似文献   

19.
The environmental CRMs currently available from NRC Ottawa comprise four natural waters for trace elements, four biological tissues for trace elements and methylmercury, three marine sediments for major and trace elements (one sediment has certified values for butyltins) and one fish tissue for organochlorines (PCBs, dioxins). Although significant effort has been expended to maintain this suite of materials, several new initiatives have also recently been completed or are in progress. The certified value for arsenobetaine in Dogfish Muscle CRM DORM-2 has been established. The certification approaches, as well as the studies to determine extraction efficiency of this organoarsenic compound, are presented. A stability study has been completed for Hg in a natural water sample and plans are underway for production of a CRM. Assessment of micronutrient stability in seawater for the purposes of CRM production is continuing and progress on this initiative is discussed.  相似文献   

20.
Reliable measurement results of electrolytic conductivity (EC), in particular for low values, must be metrologically traceable and be based on a realistic measurement uncertainty budget. The use of certified reference materials (CRMs) can help to achieve this goal. This paper presents results from all stages of the certification of an EC CRM with a conductivity of 1.5 μS cm?1, including the preparation of the batch solution and the evaluation of the homogeneity and stability of the bottled CRM. An uncertainty budget is presented for the CRM, including the main contributions from each of these sources. The CRM batch remained stable within its certified uncertainty for more than 1 year.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号