首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
This study compared the effectiveness of different biosorbents, viz. materials commonly present in natural treatment systems (Scenedesmus quadricauda and reed) and commonly produced fruit wastes (orange and banana peel) to remove Cr(III) and Cr(VI) from a synthetic wastewater simulating tannery wastewater. The Cr(III) removal efficiency followed the order S. quadricauda?>?orange peel?>?banana peel?>?reed, whereas the Cr(VI) removal followed the order banana peel?>?S. quadricauda?>?reed?>?orange peel. The chromium biosorption kinetics were governed by the intraparticle diffusion mechanism. Isotherm data obtained using the different biosorbents were fitted to the Langmuir, Freundlich, and SIPS models, revealing that the experimental data followed most closely the monolayer sorption theory-based Langmuir model than the other models. The maximum Cr(III) sorption capacity, calculated using the Langmuir model, was found to be 12 and 9 mg/g for S. quadricauda and orange peel, respectively, and the maximum Cr(VI) sorption capacity calculated for banana peel was 3 mg/g. The influence of biosorbent size, pH, solid–liquid ratio, and competing ions were examined for Cr(III) biosorption by S. quadricauda and orange peel and for Cr(VI) sorption by banana peel. The solution pH was found to be the most influential parameter affecting the biosorption process: whereas pH 5 was found to be optimum for maximum removal of Cr(III), Cr(VI) was best removed at a pH as low as 3. Interference to chromium sorption by various ions revealed that Cr(III) binding onto orange peel occurs through electrostatic forces, whereas Cr(VI) binding onto banana peel through non-electrostatic forces.  相似文献   

2.
A simple, sensitive and reliable method has been developed for separation and preconcentration of chromium (VI) from aqueous samples before determination by electrothermal atomic absorption spectrometry. The method is based on the extraction of the hydrophobic complex of chromium (VI) with ammonium pyrrolidine dithiocarbamate in the coacervates made up of decanoic acid reverse micelles in the water–tetrahydrofuran mixture. Parameters affecting the extraction efficiency of the analyte were studied and optimised. Under the optimum conditions, the linear range, enhancement factor, the limit of detection and limit of quantification were found to be 0.008–0.4 µg L?1, 127, and 1.8 ng L?1 and 6.0 ng L?1, of Cr(VI), respectively. The relative standard deviation at the concentration level of 0.1 µg L?1 Cr(VI) (n = 6) was 4.2%. Total chromium was determined after the oxidation of Cr(III) to Cr(VI) with permanganate in acidic medium. The method was successfully applied to the determination of chromium species in water and human serum samples.  相似文献   

3.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

4.
Application of Dowex 50W-X8 loaded with 2-amino-benzenethiol for preconcentration of total chromium (Cr(VI) and Cr(III)) in water samples and subsequent determination by inductively coupled plasma-atomic emission spectrometry was studied. The reagent 2-amino-benzenethiol loaded onto the resin effectively reduced Cr(VI) to Cr(III) and total chromium (both Cr(VI) and Cr(III)) formed chelate complex with the reagent in the Cr(III) valence state. Experimental parameters such as preconcentration time, solution flow rates, pH, and concentration of the eluent were optimized. The method has been applied for the determination of total chromium in seawater samples in the range of 0.1–200?µg?L?1. A detection limit of 0.3?µg?L?1 was achieved, and the relative standard deviation was about 5%.  相似文献   

5.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

6.
A new analytical procedure for the determination of chromium Cr(III) and Cr(VI) species in different water samples was developed. The method involves solid-phase extraction (SPE), direct ultrasonic slurry sampling (DUSSS), and subsequent electrothermal atomic absorption spectrometry (ETAAS). The nanometer-sized zirconium dioxide (ZrO2) was used as the sorbent material. The optimal conditions for the proposed solid phase extraction were: 50 mg ZrO2, 20 min extraction time, pH 2.5 for Cr(VI) and pH 8.0 for Cr(III) and for the ETAAS measurement: 1500°C pyrolysis and 2300°C atomisation temperatures, 1.5 g L?1 Mg(NO3)2 as matrix modifier. The samples were sonicated directly in the autosampler cup, using an ultrasonic probe at 20% power setting for 10 seconds prior to injection into the graphite tube with ?vov platform. In this way, all drawbacks due to the elution procedure were eliminated. The limit of detection and limit of quantification for Cr(III) obtained under optimised conditions were 0.48 μg L?1, and 1.61 μg L?1, respectively, and for Cr(VI) 0.27 μg L?1 and 0.90 μg L?1. The pre-concentration factors attained for both the species were 25. The effects of alkaline, alkaline earth and some metal ions and some anions were also examined. The relative standard deviation estimated from six replicate measurements at a concentration of 0.4 μg L?1 for both Cr(III) and Cr(VI) with a pre-concentration factor of 25 was 2.96% and 4.06%, respectively. The accuracy of the method was confirmed by analysis of the standard reference material SRM 1643e “Trace Elements in Water?. The proposed technique is simple, sensitive, environmentally friendly, and the risk of contamination is low. Hence, it was successfully applied to spiked synthetic and real water samples with recoveries ranging from 91.3% to 109.2%  相似文献   

7.
An inductively coupled plasma atomic emission spectrometric (ICP-AES) method was developed for speciation and simultaneous determination of Cr and As, since these two analytes are commonly determined in various water samples in order to assess their toxicity. The objective of this research was to study the speciation of Cr(III), Cr(VI) in the presence of As(III) and/or As(V) using solid phase extraction (SPE) and ICP-AES. For these measurements, four spectral lines were used for each analyte with the purpose of selecting the most appropriate for each element. Finally with the use for first time of a cation-exchange column filled with benzosulfonic acid and elution with HCl, the speciation in solutions which contained [Cr(III)?+?Cr(VI)?+?As(V)] and [Cr(III)?+?Cr(VI)?+?As(III)] was examined. It was demonstrated that the separation of the two chromium species is almost quantitative and the simultaneous determination of chromium species and total arsenic analytes is possible, with very good performance characteristics. The estimated limits of detection for Cr(III), Cr(VI), As(III) and/or As(V) were 0.9?µg?L?1, 1.1 µg?L?1, 4.7 µg?L?1 and 4.5 µg?L?1 respectively, the calculated relative standard deviations (RSDs) were 3.8%, 4.1%, 5.2% and 5.1% respectively, and finally the accuracy of the methods was estimated using a certified aqueous reference material and found to be 5.6% and 4.8% for Cr(III) and Cr(VI) respectively. The method was applied to the routine analysis of various water samples.  相似文献   

8.
An adsorptive stripping voltammetric method for speciation analysis of chromium in natural water samples has been developed. Ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) were used as complexing agents for Cr(III) present in the sample and formed as products of Cr(VI) reduction, respectively. Under optimum experimental conditions linear relations in the range from 1×10?6 to 3×10?5 mol L?1 without accumulation and from 1×10?9 to 1×10?7 at 30 s accumulation time were obtained for Cr(III) and Cr(VI), respectively. For samples in which Cr(III) concentration is higher than 1×10?6 mol L?1 the Cr(III) and Cr(VI) were determined simultaneously in one voltammetric cell. For samples in which Cr(III) concentration is below 1×10?6 mol L?1 only Cr(VI) was selectively determined in the presence of Cr(III), which did not influence the Cr(VI) signal. The determination of Cr(III) and Cr(VI) was successful with the application of the proposed procedure in the presence of common foreign ions. The presented method was applied for the speciation of chromium in spiked tap and river water samples with satisfactory results.  相似文献   

9.
Ying Gu  Xiashi Zhu 《Mikrochimica acta》2011,173(3-4):433-438
A sensitive and selective method for the speciation of Cr(III) and Cr(VI) in water samples was developed. It is based on the selective binding of the complex formed between Cr(III) and 4-(2-pyridylazo)resorcinol adsorbed on a cross-linked polymer modified with β-cyclodextrin and placed in a micro-column. Graphite furnace atomic absorption spectrometry (GFAAS) was used to quantify chromium. Cr(VI) ion is not adsorbed but remains in the aqueous sample phase. Thus, an in-situ separation of Cr(VI) and Cr(III) is accomplished. The concentration of Cr (VI) was calculated by subtracting the value for Cr(III) from that for total chromium. Under optimum conditions, the limit of detection of Cr(III) is 0.056 μg L?1, and the linear range is from 2.0 to 160.0 μg L?1. The relative standard deviation is 2.5% (n?=?3, at 30.0 μg L?1). The preconcentration factor is 25. The method was applied to the speciation of chromium in water samples, and recoveries in spiked real samples range from 101.9% to 104.5%. A reference water sample (GBW(E)080642) also was analyzed, and the results were in good agreement with the certified values.
Figure
The quantitative adsorption (≥90%) on the β-CDCP for Cr(III) was found in the range of the pH 5.5–6.0, whereas the adsorption efficiency for Cr(VI) at this pH range was rather low.  相似文献   

10.
Microcolumn packed single-walled carbon nanotubes (SWCNTs) were used as solid phase extraction adsorbent for chromium speciation coupled to inductively coupled plasma mass spectrometry for detection. The effects of the experimental parameters, including pH of the solution, sample flow rate, volume and concentration of eluent, sample volume and interfering ions, on separation and determination of Cr(III) and Cr(VI) were investigated in detail. It was found that Cr(III) was selectively sorbed on the microcolumn packed with SWCNTs in the pH range from 2.0 to 4.0, while Cr(VI) remained in solution. The retained Cr(III) was subsequently eluted with 2.0 mL of 1.2 mol L?1 nitric acid. Under the optimum conditions, the detection limits based on 3σ criterion were 0.01 ng mL?1 and 0.024 ng mL?1 for Cr(III) and Cr(VI), respectively. The relative standard deviations were less than 5.0% (n?=?9, c?=?1.0 ng mL?1). The method was successfully applied to the speciation of chromium in real samples including natural and waste water. The recoveries of spiked samples were higher than 92.5%.  相似文献   

11.
《Electroanalysis》2006,18(12):1223-1226
A sensitive catalytic adsorptive stripping voltammetric procedure for determination of traces of total chromium in environmental samples is reported. The method is based on the preconcentration of a Cr(III)? H2DTPA complex by adsorption at the HMDE from an acetate buffer solution at the potential ?1.0 V vs. Ag/AgCl. Total chromium was determined as Cr(III) after reduction of Cr(VI) to Cr(III) by NaHSO3. In order to stabilize the signal of Cr(III) the measurements were performed at 5 °C. The calibration graph for chromium for an accumulation time of 60 s was linear in the range from 5×10?10 to 5×10?8 mol L?1. The relative standard deviation for a chromium concentration of 1×10?8 mol L?1 was 3.9% (n=5). The detection limit for accumulation time of 60 s was about 8×10?11 mol L?1. The validation of the procedure was performed by the analysis of the certified reference materials.  相似文献   

12.
A novel method for preconcentration is described for chromium speciation at microgram per liter to sub-microgram per liter levels. It is based on selective complex formation of both Cr(VI) and Cr(III) followed by dispersive liquid–liquid microextraction and determination by microsample introduction-flame atomic absorption spectrometry. Effects influencing complex formation and extraction (such as pH, temperature, time, solvent, salinity and the amount of chelating agent) have been optimized. Enrichment factors up to 275 and 262 were obtained for Cr(VI) and total Cr, respectively. The calibration graph is linear from 0.3 to 20 µg L?1, and detection limits are 0.07 and 0.08 µg L?1 for Cr(VI) and total Cr, respectively. Relative standard deviations (RSDs) were obtained to be 2.0% for Cr(VI) and 2.6% for total Cr (n?=?7).  相似文献   

13.
A simple, rapid, sensitive, and inexpensive method for spectrophotometric determination of chromium(VI), based on the absorbance of its complex with 1,4,8,11-tetraazacyclotetradecane (cyclam) is presented. The complex showed a molar absorbtivity of 1.5?×?104?L?mol?1?cm?1 at 379?nm. Under optimum experimental conditions, a pH of 4.5 and 1.960?×?103?mg?L?1 cyclam were selected, and all measurements were performed 10?min after mixing. Major cations and anions did not show any interference; Beer's law was applicable in the concentration range 0.2–20?mg?L?1 with a detection limit of 0.001?mg?L?1. The standard deviation in the determination is ±0.5?mg?L?1 for a 15.0?mg?L?1 solution (n?=?7). The described method provides a simple and reliable means for determination of Cr(VI) in real samples.  相似文献   

14.
A novel inhibition-based glucose oxidase (GOx) biosensor for environmental chromium(VI) detection is described. An electropolymerized aniline membrane has been prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx is cross-linked by glutaraldehyde. The mechanism of the redox reaction on the electrode and the performance of the sensor are studied. The sensor's response to glucose decreases when it is inhibited by chromium(VI), with a lower detection limit of 0.49?µg?L?1, and the linear response range is divided into two parts, one of which is 0.49–95.73?µg?L?1 and the other is 95.73?µg?1 to8.05?mg?L?1. The enzyme membrane is shown to be completely reactivated after inhibition, retaining 90% activity over more than forty days. Interference to chromium(VI) determination from lead(II), copper(II), cadmium(II), chromium(III), cobalt(II), tin(II) and nickel(II) is found to be minimal, while high concentrations of mercury(II) and silver(I) may interfere with the determination of trace chromium(VI). The sensor has been used for chromium(VI) determination in soil samples with good results.  相似文献   

15.
Three bacterial isolates, GT2, GT3, and GT7, were isolated from the sludge and water of a circulating cooling system of iron and steel plant by screening on Cr(VI)-containing plates. Three isolates were characterized as the members of the genus Pseudomonas on the basis of phenotypic characteristics and 16S rRNA sequence analysis. All isolates were capable of resisting multiple antibiotics and heavy metals. GT7 was most resistant to Cr(VI), with a minimum inhibitory concentration (MIC) of 6.5 mmol L?1. GT7 displayed varied rates of Cr(VI) reduction in M2 broth, which was dependent on pH, initial Cr(VI) concentration, and inoculating dose. Total chromium analysis revealed that GT7 could remove a part of chromium from the media, and the maximum rate of chromium removal was up to 40.8 %. The Cr(VI) reductase activity of GT7 was mainly associated with the soluble fraction of cell-free extracts and reached optimum at pH 6.0~8.0. The reductase activity was apparently enhanced by external electron donors and Cu(II), whereas it was seriously inhibited by Hg(II), Cd(II), and Zn(II). The reductase showed a K m of 74 μmol L?1 of Cr(VI) and a V max of 0.86 μmol of Cr(VI) min?1 mg?1 of protein. The results suggested that GT7 could be a promising candidate for in situ bioremediation of Cr(VI).  相似文献   

16.
A simple speciation, separation and enrichment method has been developed for the determination of Cr(III) and Cr(VI) ions in different samples by ion-pair solvent extraction with a β-diketone ligand, 2-(4-methoxybenzoyl)-N′-benzylidene-3-(4-methoxyphenyl)-3-oxo-N-phenyl-propono hydrazide (MBMP). Cr(III) was separated from Cr(VI) as Cr(III)-(MBMP)-perchlorate ternary ion-pair complex. The influences of various analytical parameters including pH, amount of reagent, shaking time, sample volume and ionic strength on the recovery of Cr(III) and/or Cr(VI) were investigated. Total chromium was obtained after reducing Cr(VI) to Cr(III) with NH2OH?·?HCl. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 2%. The method detection limit based on 3σ criterion for Cr(III) was found to be 0.32?µg?L?1. The formed ternary ion-pair complex, Cr(III)?:?MBMP?:?2ClO4, has a molar ratio of 1?:?1?:?2. The developed method has been applied successfully to the speciation of chromium in various natural water, soil, sediment and hair samples with satisfactory results.  相似文献   

17.
A new sensitive chemiluminescence (CL) method combined with continuous flow injection analysis is described for the determination of Cr(VI). Strong CL signals were generated by Cr(VI)-catalysed oxidation of gallic acid in the presence of potassium permanganate and hydrogen peroxide. Effects of reagent concentrations, temperature, pH, flow rates, mixing coil length and mixing flow sequences on the chemiluminescence intensity were studied. Under the optimised experimental conditions, the relationship between the logarithm of concentration (log?C) of Cr(VI) and the logarithm of intensity (log?I) is linear over the range of 2?×?10?11 – 5?×?10?4?mol?L?1, with the detection limit (3σ) of 4?×?10?12?mol?L?1. Relative standard deviation of ten measurements of 1?×?10?9?mol?L?1 Cr(VI) is 1.7%. This flow injection analysis (FIA) system proved to be able to analyse up to 40 samples h?1. Effects of various interferences possibly present in the water samples were investigated. Most cations and anions, as well as organic compounds, did not interfere with the determination of Cr(VI) in water samples. The experimental results obtained for chromium in reference materials were also in good agreement with the certified values.  相似文献   

18.
In this work, a simple and fast procedure for elimination of interfering surface active substances and for U(VI) adsorptive stripping voltammetric determination was developed. The adsorption in the form of U(VI)-cupferron complexes was performed, because as it was proved before, U(VI) forms with cupferron stable complexes, which were employed in voltammetric procedures. The procedure is based on two steps: the first is an adsorption of surface active substances onto an Amberlite XAD-16 or XAD-7 resin and the second is a voltammetric determination of U(VI) with a pulsed potential of accumulation alternate –0.65–0.3 V with the frequency of 0.5 Hz and then the differential pulse voltammogram was recorded, whereas the potential was scanned from –0.65 to –1.2 V. The detection limit estimated from three times the standard deviation for a low U(VI) concentrations was equal to 1.7 × 10?10 mol L?1 (7.2 × 10?8 g L?1). The linear range of U(VI) was observed over the concentration range from 5.0 × 10?10 mol L?1 (2.1 × 10?7 g L?1) to 2.0 × 10?8 mol L?1 (8.5 × 10?6 g L?1) for an accumulation time of 60 s. The influence of different kinds of surfactants, such as non-ionic, cationic and anionic on the uranium voltammetric signal was studied. The results confirm the possibility of U(VI) determination in water samples containing high concentrations of surface active substances even up to 50 mg L?1.  相似文献   

19.
The voltammetric method of Cr(VI) determination in a flow system is proposed. Determinations can be carried out in the simultaneous presence of an excess of Cr(III), complexing agents, humic substances and surfactants. The method is based on the combination of a selective accumulation of the product of Cr(VI) reduction to the metallic state and a very sensitive voltammetric method of chromium determination in the presence of DTPA and nitrates. The calibration graph is linear from 1×10?9 to 5×10?8 mol L?1 for accumulation time of 30 s. The relative standard deviation is 5.2% (n=5) for Cr(VI) concentration 1×10?8 mol L?1. The influence of humic and fulvic acids, complexing agents and surfactants on Cr(VI) and the interfering Cr(III) signal is presented. The method was applied to Cr(VI) determination in certified reference material, soil sample, natural water sample and EDTA extracts from soil certified reference material.  相似文献   

20.
In the present work, the catalytic adsorptive stripping voltammetric procedure for trace determination of Cr(VI) in the presence of a high excess of Cr(III) in natural waters with a complicated matrix has been developed. The influence from potentially interfering substances such as organic matter was successfully eliminated by exploiting adsorptive properties of polymeric resin. The detection limit estimated from 3 times the standard deviation for a low Cr(VI) concentration in the simultaneous presence of a 2×103 fold excess of Cr(III), 50 mg L?1 surfactants, 50 mg L?1 humic substances and the accumulation time of 30 s was about 5.3×10?10 mol L?1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号