共查询到20条相似文献,搜索用时 15 毫秒
1.
The resin spot test is modified by the use of a high molecular weight amine, Amberlite LA-1, in carbon tetrachloride; 0.2 μg of cobalt(II) can be detected rapidly by shaking an acidic solution containing thiocyanate with a 5% amine solution. Amine-impregnated papers can also be used. 相似文献
2.
V. I. Grachek A. A. Shunkevich R. V. Martsinkevich 《Russian Journal of Applied Chemistry》2009,82(1):17-22
New nitrogen-and-phosphorus-containing fibrous ion exchangers were produced by two-stage synthesis from Nitron fiber. The ion exchangers are efficient sorbents of heavy and nonferrous metals from aqueous solutions under dynamic conditions. 相似文献
3.
A new sensitive and selective resin spot test for nanogram quantities of molybdenum(Vl) with tiron is proposed. The limit of identification is 8 ng(1:5 · 106) after 1 hour standing. Vanadium(V), chromium(VI), uraniuni(lV), titanium (IV), palladiuin(II), platinum(lV), silver(I) and gold(III) interfere. Uranium(VI) (20 ng 1:2·106) can be detected similarly. 相似文献
4.
5.
Kanatyeva AY Viktorova EN Korolev AA Kurganov AA 《Journal of separation science》2007,30(17):2836-2842
Low capacity anion exchangers for IC have been prepared by modification of nonporous uniformed silica MICRA microbeads and by modification of the organic polymeric monolithic matrixes prepared in situ in quarz capillary. Due to the small particle size (1.5 microm) high-performance adsorbents were prepared allowing to obtain up to 190,000 tp/m. However, the column possesses a very high back-pressure and can be used in a short length up to 50 mm only to meet the requirements of conventional chromatographic equipment. An analysis of a test mixture of seven anions was completed within 3 min with a back column pressure of about 350 bar (HETP of about 5.5 microm, where HETP is the height equivalent to the theoretical plate). Monolithic capillary columns provide lower efficiency per column unit length than MICRA columns; however, they can be used at a longer length because of their low flow resistance. Monolithic column of ca. 40 cm length has workable pressure below 10 bar and allows separation of a five anions test mixture within less than 10 min. A better efficiency of monolithic column (HETP approximately 75 microm) can be achieved at reduced flow rates when the analysis time is not a critical parameter. 相似文献
6.
7.
Sorption capacity of ion exchangers based on glycidyl derivatives of aromatic compounds and polyamines was studied in relation to pH of solution. The mechanism of sorption of polyvalent metal ions was examined. 相似文献
8.
T. A. Korshunova E. G. Kosandrovich V. S. Soldatov 《Russian Journal of Applied Chemistry》2010,83(7):1159-1169
Hydrogen chloride sorption from the air in a wide range of relative humidity and the concentration of the absorbing component
was examined under dynamic conditions with fibrous anion exchanger FIBAN distinguishing by basicity and type of functional
groups. 相似文献
9.
The hydrolysis of oligosaccharides by sulphonic ion exchangers has been performed in batch and in column experiments. The rate constants and selectivity are compared with the values obtained in homogeneous phase with H2SO4 and polystyrene sulphonic acid. The rate constants are lower in the presence of ion exchangers for dimers and the efficiency decreases as the degree of polymerization of the oligosaccharides increases, because of control by intraparticle diffusion. It is concluded that the ion exchanger process is rather inefficient for higher molecular weight solutes when compared with the corresponding polyelectrolyte or low molecular weight acid. 相似文献
10.
V. I. Skorokhodov B. K. Radionov O. Yu. Goryaeva 《Russian Journal of Applied Chemistry》2004,77(9):1444-1449
To characterize the reaction of zinc ions with anion exchangers of various types, the equilibrium compositions of all the components of the sorption system (zinc salt, hydrochloric acid, and water) and distribution of associated molecules in the resin phase were considered.Translated from Zhurnal Prikladnoi Khimii, Vol. 77, No. 9, 2004, pp. 1456–1461.Original Russian Text Copyright © 2004 by Skorokhodov, Radionov, Goryaeva. 相似文献
11.
Summary The gas chromatographic selectivity of K+, Zn2+, Ag+, Ni2+, and Cd2+ forms of a cation exchange packing have been determined for a set of 44 C2 to C8 alkenes. The retention characteristics of each ion are broken down into electronic (charge-transfer) and steric effects associated with the alkene sub-populations of each carbon number. Almost every pair of alkenes tested can be separated on at least one of these packings. Retention is much stronger on the ion exchangers than on metal-ion containing packings in gas-liquid chromatography, even with shorter columns and higher temperatures.Presented at the 14th International Symposium on Chromatography London, September, 1982 相似文献
12.
13.
Water sorption on an ion exchanger can be described by formation of several hydrates. The general least squares program WSLET based on the "pit-mapping" approach has been written for evaluating such equilibria. It is written in FORTRAN 77 for use on personal computers. Besides finding the best values for the equilibrium constants of the various hydrates the program also searches for best values of the stoichiometric indices by using the so-called ESI-method. The program is provided with least-squares procedures and blocks for statistical analysis of the residuals as well as for data simulation. It has been tested with data on the strong base resin Dowex 1 as well as on simulated data. In the present paper an illustrative example is given together with data simulation. It is found that in most cases WSLET helps to find a better fit than earlier models quite efficiently, showing the advantage of the ESI method in combination with least-squares methods. 相似文献
14.
Investigation of silica gel supported inorganic ion exchangers 总被引:2,自引:0,他引:2
Microcrystalline zirconium phosphate (-ZrP), hydrous manganese dioxide (HMnO), ammonium molybdophosphate (AMP) and silica gel supported forms of these materials as well as silica gel (SG) itself were investigated by thermoanalytical, electron microscopic, X-ray diffraction and infrared spectrometric methods. Chemical composition, structure and some related properties of the inorganic ion exchangers mentioned above are reported. 相似文献
15.
P.S. Remya Devi Shreeram Joshi Rakesh Verma A.M. Lali L.M. Gantayet 《Radiation Physics and Chemistry》2010,79(1):41-45
Effects of gamma radiation on indigenous strong cation and anion exchange resins have been studied in HCl medium up to a dosage of 3600 kGy. The ion exchange capacities of cation and anion exchangers decreased by around 20% at 2400 kGy of absorbed dose. Decrease in salt-splitting capacity and total exchange capacity for both cation and anion exchangers were comparable up to 2400 kGy. Above 2400 kGy, a marginal loss in the capacity was observed for cation exchangers whereas a drastic reduction was noticed for the anion exchangers. The distribution coefficients for zirconium, antimony and cobalt, measured in HCl medium, did not change significantly for 2400 kGy of absorbed dose. Crushing strength and moisture retention capacity did not exhibit any specific trend with the absorbed dose. 相似文献
16.
The composite ion exchangers were tested for their ability to remove UO2
2+ from aqueous solutions. Polyacrylonitrile (PAN) composites having natural zeolite, clinoptilolite, and synthetic zeolite, zeolite X, were used as an adsorbents. The influences of pH, U(VI) concentration, temperature and contact time on the sorption behavior of U(VI) were investigated in order to gain a macroscopic understanding of the sorption mechanism. The optimum adsorption conditions were determined for two composites. The sorption behaviors of uranium on both composites from aqueous systems have been studied by batch technique. Parameters on desorption were also investigated to recover the adsorbed uranium. 相似文献
17.
E. G. Kulapina N. M. Makarova L. A. Bazhanova E. S. Pogorelova 《Journal of Analytical Chemistry》2012,67(6):537-542
Potentiometric sensors with plasticized polymer membranes based on organic ion exchangers, tetraalkylammonium dodecyl sulfates (benzyldimethyldodecylammonium, benzyldimethyltetradecylammonium, dimethyldistearylammonium), have been proposed for the determination of quaternary ammonium salts in model solutions and KATAPAV technical solutions. The thermal stability, composition, and solubility product have been estimated. It has been shown that ion associates are stable to 60?C70°C, K S varies in the range from 2 × 10?8 to 5 × 10?10. The basic electrochemical parameters of the sensors have been determined as well, such as linearity ranges of the electrode function (5 × 10?5 (5 × 10?6)?1 × 10?2 (1 × 10?3) M) and slopes of the electrode functions (47?C59 mV/pc), response time (60?C90 sec), potential drift (2?C3 mV/day), operation period (3?C4 months), limits of detection for tetramethylammonium salts (1 × 10?5?4 × 10?7 M). 相似文献
18.
Liquid ion exchangers in reversed-phase systems for chromatography of steroidal glucosiduronic acids
Vernon R. Mattox Robert D. Litwiller June E. Goodrich W.C. Tan 《Journal of chromatography. A》1976,120(2):435-447
Steroidal glucosiduronic acids were chromatographed on paper by the reversed-phase technique using five different liquid ion exchangers as stationary phase and aqueous KCl as mobile phase. The relationship of mobility of the acids (RM) to both the amount of exchanger on the paper and the concentration of KCl in the mobile phase is discussed: the relationships may be expressed as RM = n·log [exchanger] + const. and RM = −n·log [KCl] + const., respectively. Migration of the acids in the presence of different exchangers is correlated by use of the equation RM (exchanger Y) = a·RM (exchanger X) + b. The lack of appreciable correlation between migration of the acids in a reversed-phase system and a corresponding straight-phase system is discussed and expressed by means of regression equations. The correlation coefficients and standard errors of estimate from these equations provide useful indices for selecting two solvent systems that are to be used sequentially to obtain maximal resolution of a group of compounds. ΔRM values obtained for various functional groups with reversed-phase and straight-phase techniques are compared. 相似文献
19.
C. Janardanan S. M. K. Nair C. P. Savariar 《Journal of Radioanalytical and Nuclear Chemistry》1988,127(1):21-29
The effect of -irradiation on the ion-exchange capacity, distribution coefficient and the efficiency for binary separations of some thermally stable inorganic ion exchangers have been studied. Irradiation upto 100 Mrad, has no effect on these substances, except thorium tungstate which showed changes in ion-exchange capacity, distribution behaviour and in binary separations. 相似文献
20.
Group fractionation of plasma proteins on dipolar ion exchangers 总被引:6,自引:0,他引:6