首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
End-labeled free-solution electrophoresis of DNA   总被引:1,自引:0,他引:1  
DNA is a free-draining polymer. This subtle but "unfortunate" property of highly charged polyelectrolytes makes it impossible to separate nucleic acids by free-flow electrophoresis. This is why one must typically use a sieving matrix, such as a gel or an entangled polymer solution, in order to obtain some electrophoretic size separation. An alternative approach consists of breaking the charge to friction balance of free-draining DNA molecules. This can be achieved by labeling the DNA with a large, uncharged molecule (essentially a hydrodynamic parachute, which we also call a drag-tag) prior to electrophoresis; the resulting methodology is called end-labeled free-solution electrophoresis (ELFSE). In this article, we review the development of ELFSE over the last decade. In particular, we examine the theoretical concepts used to predict the ultimate performance of ELFSE for single-stranded (ssDNA) sequencing, the experimental results showing that ELFSE can indeed overcome the free-draining issue raised above, and the technological advances that are needed to speed the development of competitive ELFSE-based sequencing and separation technologies. Finally, we also review the reverse process, called free-solution conjugate electrophoresis (FSCE), wherein uncharged polymers of different sizes can be analyzed using a short DNA molecule as an electrophoretic engine.  相似文献   

2.
Separating DNA sequencing fragments without a sieving matrix.   总被引:1,自引:0,他引:1  
The possibility of separating appropriately labeled DNA fragments using free-flow capillary electrophoresis was predicted a few years ago based on simple theoretical arguments. Free-flow separation of double-stranded DNA (dsDNA) fragments in the 100-1000 base range was later demonstrated using a streptavidin label. In this article, we now report that end-labeled free-flow electrophoresis (ELFSE) can also be used to sequence single-stranded DNA (ssDNA). The first 100 bases of a DNA sequencing reaction were read without any sieving matrix when fractionated streptavidin was added to the 5'-end of the ssDNA fragments. These separations required only 18 min and did not require coated capillaries. An analysis of the results indicates that sample injection, analyte-wall interactions and thermal diffusion are the limiting factors at this time. Extrapolating from our data, we predict that several hundred bases could be sequenced in less than 30 min with the proper conditions. ELFSE thus offers an attractive potential alternative to polymer solutions for DNA sequencing in capillaries and microchips.  相似文献   

3.
Polygalacturonic acid, a linear high molecular weight homopolysaccharide was investigated as a chiral selector in capillary zone electrophoresis for the separation of enantiomers of basic drugs. The choices of running buffer pH and concentration of chiral selector were found to be important for the improvement of enantioselectivity. The effects of background electrolyte concentration and the capillary temperature on the separation were also examined. Enantioseparations were carried out in the acidic conditions using 1.5% polygalacturonic acid (w/v) in a 40 mM phosphate buffer under an applied voltage of 15 kV. The optimization of these separations was dependent on the nature of the analytes and could be achieved by the proper choice of experimental conditions. A brief mechanism of enantiorecognition by polygalacturonic acid was also given.  相似文献   

4.
End-labeled free-solution electrophoresis (ELFSE) is an alternative approach to gel-based methods for size-based electrophoretic separation of DNA. In ELFSE, an electrically neutral "drag-tag" is appended to DNA to add significant hydrodynamic drag, thereby breaking its constant charge-to-friction ratio. Current drag-tag architecture relies on covalent attachment of polymers to each DNA molecule. We have recently proposed the use of micellar drag-tags in conjunction with sequence-specific hybridization of peptide nucleic acid amphiphiles (PNAAs). This work investigates the effect of multiple PNAA attachment on DNA resolution using MEKC. Simultaneous PNAA hybridization allows for the separation of long DNA targets, up to 1012 bases, using micellar drag-tags. Each PNAA handle independently interacts with the micellar phase, reducing the overall mobility of this complex relative to individual PNAA binding. The sequence- and size-based dependence of this separation technique is maintained with multiple PNAA binding over a range of DNA sizes. Results are accurately described by ELFSE theory, yielding alpha=54 for single-micelle tagging and alpha=142 for dual-micelle tagging. This method is the first example of a non-covalent drag-tag used to separate DNA of 1000 bases based on both size and sequence.  相似文献   

5.
Zhu  Fenxia  Du  Yingxiang  Chen  Jiaquan  Chen  Bin  Zhu  Yanqian  Zhai  Xiang  Xu  Shu  Zhou  Wenhui 《Chromatographia》2009,69(11):1315-1320

Polygalacturonic acid, a linear high molecular weight homopolysaccharide was investigated as a chiral selector in capillary zone electrophoresis for the separation of enantiomers of basic drugs. The choices of running buffer pH and concentration of chiral selector were found to be important for the improvement of enantioselectivity. The effects of background electrolyte concentration and the capillary temperature on the separation were also examined. Enantioseparations were carried out in the acidic conditions using 1.5% polygalacturonic acid (w/v) in a 40 mM phosphate buffer under an applied voltage of 15 kV. The optimization of these separations was dependent on the nature of the analytes and could be achieved by the proper choice of experimental conditions. A brief mechanism of enantiorecognition by polygalacturonic acid was also given.

  相似文献   

6.
Song X  Li L  Qian H  Fang N  Ren J 《Electrophoresis》2006,27(7):1341-1346
In this paper, we present a new method for highly efficient size separation of water-soluble CdTe quantum dots (QDs) based on CGE using polymer solution as sieving medium. CdTe QDs were synthesized in aqueous phase by a chemical route with mercaptopropionic acid as a ligand. In the alkaline solution, CdTe QDs possess negative charges and migrate to the anode in the electric field. In linear polyacrylamide sieving medium, the migration time of CdTe QDs was increased with the size of CdTe QDs. The effects of some factors, such as types, concentrations, and pH of sieving media, on the separation of CdTe QDs were investigated systematically. Highly efficient separation of CdTe QDs was obtained in linear polyacrylamide sieving medium, and collection of fractions was automatically accomplished by CGE technique. Our preliminary results show that CGE technique is an efficient tool for characterization and size-dependent separation of water-soluble nanoparticles. In addition, the fraction collection in CGE may be useful in certain special applications such as fabrication of nanodevices in the future.  相似文献   

7.
The analysis of polyamide-6 oligomers and polymer is usually performed with expensive fluorinated alcohols like 2,2,2-trifluoroethanol (TFE) or 1,1,1,3,3,3-hexafluoroisopropanol (HFIP). Formic acid is well known as a mobile phase additive to adjust pH in reversed-phase high-performance liquid chromatography. However, formic acid is seldom used as a modifier to perform gradient elution chromatography on octadecyl-modified silica-based columns. Here we demonstrate the determination of cyclic and linear polyamide-6 oligomers using formic acid as a modifier on an octadecyl-modified silica-based column. This column was shown to be stable for more than 5000 column volumes, even when a mobile phase of 65-95% formic acid in water at a flow of 1 ml/min is applied. With formic acid under the conditions used (65-95% formic acid in water) the oligomers are retained on the column, while the polymer does not precipitate. In comparison, during adsorption and separation with a HFIP gradient, precipitation of the polymer occurs. The implications of the different separation mechanisms, i.e., adsorption vs. precipitation chromatography are discussed. Loadability is shown to be much better with the formic acid system. However, with formic acid as a modifier UV detection below 250 nm is not feasible. The less sensitive evaporative light scattering detector is used to detect the polyamide oligomers in the formic acid phase. In addition it is shown that capillary zone electrophoresis (CZE) with UV-absorbance detection using HFIP is an attractive combination as HFIP is UV-transparent and CZE allows low modifier consumption.  相似文献   

8.
A high-performance size-exclusion chromatography-evaporative light scattering detector method was used to separate, detect and quantify galacturonic acid (GA) oligomers. In 40 mM acetic acid GA monomer, dimer and trimer could be separated with baseline resolution but polygalacturonic acid (PGA) precipitated and could not be eluted from the column. An NH4OAc, pH 3.7, buffer was developed as the eluent which separated GA oligomers as well as PGA and pectin without precipitation. Linear calibration curves for mono-, di- and tri-GA were produced with this buffer which could be used to estimate masses of tetra-, penta- and hexa-GA, as well as 19mer and 20mer.  相似文献   

9.
McCormick LC  Slater GW 《Electrophoresis》2007,28(21):3837-3844
DNA sequencing by electrophoresis can be dramatically sped up by overcoming the need for the sieving medium. Normally it is possible to separate DNA based on size in free solution; however, not end-labeled free-solution electrophoresis (ELFSE) uses a neutral drag-tag molecule to make it possible. In experiments to date, the drag-tag and DNA together form a random coil conformation; while with future generation drag-tags and high fields, deformation of this conformation may occur. In the first paper in this series we investigated the conditions under which the DNA and label become hydrodynamically distinct (or segregated), based on a theoretical approach developed for the electrophoresis of polyampholytes. In this paper we study further deformation wherein either the DNA and/or a polymeric label stretch. We show that deformation may dramatically improve the capabilities of ELFSE, especially when both the DNA and a polymeric drag-tag fully stretch; however, reaching these regimes will require extremely high field intensities, something that only microchip technologies may be able to achieve.  相似文献   

10.
The first six linear and cyclic oligomers of polyamide-6 can be quantitatively determined in the polymer using HPLC with the sandwich injection method and an aqueous acetonitrile gradient. In this final part of the triptych concerning the determination of the oligomers in polyamide-6, the irregular elution behavior of the cyclic monomer compared to the cyclic oligomers was investigated. We also optimized the separation of the involved polyamide oligomers, with respect to gradient steepness, stationary phase, column temperature and mobile phase pH. The irregular elution behavior of the cyclic monomer could be caused by its relatively large exposed/accessible hydrophobic surface, which permits relatively easy penetration into the hydrophobic stationary phase giving extra retention. The dipole moment of the different oligomers was used as a measure for this exposed/accessible hydrophobic area to correlate the retention factors using quantitative structure-retention relationships. We also studied the retention behavior of the polyamide, which is injected each run directly onto the column and modifies the stationary phase. Using a 250-microl post gradient injection zone of formic acid on a 250x3 mm Zorbax SB-C18 column, the polyamide could be effectively removed from the stationary phase after each separation. The linear solvent strength (LSS) model was used to optimize the separation of the first six linear and cyclic oligomers. As the LSS model assumes a linear correlation between the modifier concentration and the logarithm of the retention factor and the cyclic monomer and dimer show extreme curvation of this relation in the eluting region, we investigated different models to predict gradient elution from isocratic data. A direct translation of the isocratic data to gradient retention times did not yield adequate retention times using the LSS model. It was found that the LSS model worked acceptably if gradient retention times were used as input data. Even for fast non-linearly eluting components, an average error of 0.4 resolution units of 4sigma was obtained. Using the LSS model in combination with different column temperatures and mobile phase pH values, a separation of the first six linear and cyclic oligomers was accomplished.  相似文献   

11.
The facile synthesis of linear and cyclic chiral oligo(4-alpha/beta-methyl)thiazolines is described. Linear oligothiazolines have been efficiently synthesized by the iterative formation of thiazoline rings and two-directional block condensation. The construction of 24- to 36-membered cyclic oligothiazolines was achieved through the head-to-tail cyclo-oligomerization of doubly deprotected linear fragments. Studies of the interactions of both the linear and cyclic oligomers with chiral compounds revealed that cyclic oligomers displayed a strong binding affinity towards mandelic acid, whereas linear oligomers showed a poor affinity. Linear oligomers have been proven to inhibit the cell growth of the cancer cell lines HPAC, PC-3, and HCT-116. Studies of the structure-activity relationships showed that the IC50 values are clearly dependent on both the length and the terminal functionalities of the linear oligomers. Longer derivatives showed more potent activity (e.g., hexi- and octithiazolines exhibit IC50<1 microM) against all three cancer cell lines. In sharp contrast, cyclic oligomers were inactive to all three cell lines.  相似文献   

12.
Qi LY  Yin XF  Zhang L  Wang M 《Lab on a chip》2008,8(7):1137-1144
A rapid and variable-volume sample loading scheme for chip-based sieving electrophoresis was developed by negative pressure combined with electrokinetic force. This was achieved by using a low-cost microvacuum pump and a single potential supply at a constant voltage. Both 12% linear polyacrylamide (LPA) with a high viscosity of 15000 cP and 2% hydroxyethylcellulose (HEC) with a low viscosity of 102 cP were chosen as the sieving materials to study the behavior and the versatility of the proposed method. To reduce the hydrodynamic resistance in the sampling channel, sieving material was only filled in the separation channel between the buffer waste reservoir (BW) to the edge of the crossed intersection. By applying a subambient pressure to the headspace of sample waste reservoir (SW), sample and buffer solution were drawn immediately from sample reservoir (S) and buffer reservoir (B) across the intersection to SW. At the same time, the charged sample in the sample flow was driven across the interface between the sample flow and the sieving matrix into the sieving material filled separation channel by the applied electric field. The injected sample plug length is in proportion with the loading time. Once the vacuum in SW reservoir was released to activate electrophoretic separation, flows from S and B to SW were immediately terminated by the back flow induced by the difference of the liquid levels in the reservoirs to prevent sample leakage during the separation stage. The sample consumption was about 1.7 x 10(2) nL at a loading time of 1 s for each cycle. Only 0.024 s was required to transport bias-free analyte to the injection point. It is easy to freely choose the sample plug volume in this method by simply changing the loading time and to inject high quality sample plug with non-distorted shape into the separation channel. The system has been proved to possess an exciting potential for improving throughput, repeatability, sensitivity and separation performance of chip-based sieving electrophoresis.  相似文献   

13.
The rapid development of DNA capillary electrophoresis (CE) technology has increased the demand of new low viscosity sieving matrices with high separation capacity. The high throughput, resolution and automatic operation of CE systems have stimulated the application of the technique to different kinds of DNA analysis, including DNA sequencing, separation of restriction fragments, PCR products and synthetic oligonucleotides. In addition specific methods for PCR-based mutation assays for the study of known and unknown point mutations have been developed for use in CE. The key component for a large scale application of CE to DNA analysis is the availability of appropriate sieving matrices. This article gives an overview of the linear polymers used as DNA separation matrices with particular emphasis on the polymers that combine high sieving capacity, low viscosity and chemical resistance.  相似文献   

14.
刘春叶  许旭  张剑  陈杰瑢 《色谱》2010,28(3):296-300
在自制的聚二甲基硅氧烷(PDMS)微芯片上,使用十二烷基磺酸钠(SDS)无胶筛分电泳分离体系(10 g/L的羟乙基纤维素(HEC), 1 g/L的SDS, 40 mmol/L磷酸盐缓冲溶液,pH 7.0),采用在线自校正激光诱导荧光检测方法,在6.4 min内高效分离了异硫氰酸荧光素(FITC)衍生的6种蛋白质标准样品,连续6次电泳所得迁移时间的相对标准偏差(RSD)均小于10%。用自主建立的脱氧核糖核酸(DNA)定量分离模型对蛋白质迁移数据进行拟合,发现SDS-蛋白质复合物迁移规律与DNA相似,但迁移淌度与相对分子质量及电场强度之间的线性关系明显变差,可见原DNA分离模型要扩展到蛋白质范围必须对一些参数进行校正。  相似文献   

15.
Superheated water chromatography (SWC) with ultraviolet detection was applied to the separation of low molecular weight polyethylene glycols (PEGs). PEG oligomers could be detected sensitively when the detection wavelength was set at 190 nm. The effect of column temperature on the separation of PEG oligomers was investigated. The elution time of all PEG oligomers decreased with increase in the column temperature; linear relationships were obtained between ln k and 1/T. A temperature-programmed SWC separation enabled the baseline separation of a PEG 200 sample within 50 min.  相似文献   

16.
利用芯片电泳方法考察瞬间等速电泳-筛分电泳偶联分析的结果,比较了自由溶液和筛分介质中DNA瞬间等速电泳的预浓缩效果.结果显示,相比较于筛分介质条件,自由溶液瞬间等速电泳有利于改善预浓缩和后续筛分电泳分离效果.对此结果的解释是:自由溶液条件下DNA迁移速度的提高可以延长瞬间等速电泳持续时间,有利于提高预浓缩效率.此外,样品压缩区带在自由溶液-筛分介质界面的二次富集也是预浓缩效果得到改善的原因之一.  相似文献   

17.
通过实验优化了葡聚糖筛分介质和运行缓冲溶液的浓度,采用十二烷基硫酸钠(SDS)无胶筛分电泳分离体系(10%(w/v)葡聚糖,0.1%SDS,10%甘油,0.2mol/LTris-硼砂,pH8.3的缓冲液)在自制的玻璃微流控芯片上高效分离了BODIPY衍生的蛋白质分子量标准样品,连续6次电泳所得迁移时间的相对标准偏差均小于0.50%。以6种蛋白质分子量的对数对其迁移时间作图,线性回归良好(r=0.994)。采用该芯片电泳分析体系对免疫球蛋白G不同片段的分子量进行了测定,所得结果与实际基本相符。  相似文献   

18.
By separating the first six linear and cyclic oligomers of polyamide-6 on a reversed-phase high-performance liquid chromatographic system after sandwich injection, quantitative determination of these oligomers becomes feasible. Low-wavelength UV detection of the different oligomers and selective post-column reaction detection of the linear oligomers with o-phthalic dicarboxaldehyde (OPA) and 3-mercaptopropionic acid (3-MPA) are discussed. A general methodology for quantification of oligomers in polymers was developed. It is demonstrated that the empirically determined group-equivalent absorption coefficients and quench factors are a convenient way of quantifying linear and cyclic oligomers of nylon-6. The overall long-term performance of the method was studied by monitoring a reference sample and the calibration factors of the linear and cyclic oligomers.  相似文献   

19.
In end-labeled free-solution electrophoresis (ELFSE), DNA molecules are labeled with a frictional modifier or "drag-tag", allowing their size-based electrophoretic separation in free solution. Among the interesting observations from early work with dsDNA using streptavidin as a drag-tag was that the drag induced by including a streptavidin label at both ends was significantly more than double that from a single streptavidin (Heller, C. et al.., J. Chromatogr. A 1998, 806, 113-121). This finding was assumed to be in error, and subsequent work focused on experiments in which only a single drag-tag is appended to one end of the DNA molecule. Recent theoretical work (McCormick, L. C., Slater, G. W., Electrophoresis 2005, 26, 1659-1667) has examined the contribution of end-effects to the free-solution electrophoretic mobility of charged-uncharged polymer conjugates, reopening the question of enhanced drag from placing a drag-tag at both ends. In this study, this effect is investigated experimentally, using custom-synthesized ssDNA oligonucleotides allowing the attachment of drag-tags to one or both ends, as well as dsDNA PCR products generated with primers appropriate for the attachment of drag-tags at one or both ends. A range of sizes of drag-tags are used, including synthetic polypeptoid drag-tags as well as genetically engineered protein polymer drag-tags. The enhanced drag arising from labeling both ends has been confirmed, with 6-9% additional drag for the ssDNA and 10-23% additional drag for the dsDNA arising from labeling both ends than would be expected from simply doubling the size of the drag-tag at one end. The experimental results for ssDNA labeled at both ends are compared to the predictions of the recent theory of end-effects, with reasonably good quantitative agreement. These experimental findings demonstrate the feasibility of enhancing ELFSE separations by labeling both ends of the DNA molecule, leading to greater resolving power and a wider range of applications for this technique.  相似文献   

20.
In spite of the significant progresses in the field of replaceable sieving matrices for separating DNA in capillary electrophoresis (CE), an intense research activity is still going on to improve the separation of large size DNA sequencing fragments. There are evidences, both from experimental and theoretical sides that the resolution of these fragments, at the single base, requires the use of sieving matrices comprised of long chain linear polymers. In the separation of DNA fragments by CE are of upmost importance: (i) the complete solubility of the polymer, (ii) the linearity of the chain, (iii) the achievement of ultrahigh viscosity in dilute solutions. The aim of this work is the synthesis of ultrahigh-molecular-weight polymers which possess the three requirements mentioned above by employing a nonconventional method. We demonstrate that the sieving performance of polyacrylamide is directly correlated to its intrinsic viscosity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号