首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Wang Z  Zhe J 《Lab on a chip》2011,11(7):1280-1285
Manipulation of microscale particles and fluid liquid droplets is an important task for lab-on-a-chip devices for numerous biological researches and applications, such as cell detection and tissue engineering. Particle manipulation techniques based on surface acoustic waves (SAWs) appear effective for lab-on-a-chip devices because they are non-invasive, compatible with soft lithography micromachining, have high energy density, and work for nearly any type of microscale particles. Here we review the most recent research and development of the past two years in SAW based particle and liquid droplet manipulation for lab-on-a-chip devices including particle focusing and separation, particle alignment and patterning, particle directing, and liquid droplet delivery.  相似文献   

2.
Silicones have innumerable applications in many areas of life. Polydimethylsiloxane (PDMS), which belongs to the class of silicones, has been extensively used in the field of analytical chemistry owing to its favourable physicochemical properties. The use of PDMS in analytical chemistry gained importance with its application as a stationary phase in gas chromatographic separations. Since then it has been used in many sample preparation techniques such as solid phase microextraction (SPME), stir bar sorptive extraction (SBSE), thin-film extraction, permeation passive sampling, etc. Further, it is gaining importance in the manufacturing of lab-on-a-chip devices, which have revolutionized bio-analysis. Applications of devices containing PDMS and used in the field of analytical chemistry are reviewed in this paper.  相似文献   

3.
We present a simple method for fabricating chemically-inert Teflon microfluidic valves and pumps in glass microfluidic devices. These structures are modeled after monolithic membrane valves and pumps that utilize a featureless polydimethylsiloxane (PDMS) membrane bonded between two etched glass wafers. The limited chemical compatibility of PDMS has necessitated research into alternative materials for microfluidic devices. Previous work has shown that spin-coated amorphous fluoropolymers and Teflon-fluoropolymer laminates can be fabricated and substituted for PDMS in monolithic membrane valves and pumps for space flight applications. However, the complex process for fabricating these spin-coated Teflon films and laminates may preclude their use in many research and manufacturing contexts. As an alternative, we show that commercially-available fluorinated ethylene-propylene (FEP) Teflon films can be used to fabricate chemically-inert monolithic membrane valves and pumps in glass microfluidic devices. The FEP Teflon valves and pumps presented here are simple to fabricate, function similarly to their PDMS counterparts, maintain their performance over extended use, and are resistant to virtually all chemicals. These structures should facilitate lab-on-a-chip research involving a vast array of chemistries that are incompatible with native PDMS microfluidic devices.  相似文献   

4.
M Gedge  M Hill 《Lab on a chip》2012,12(17):2998-3007
In this paper, number 17 of the thematic tutorial series "Acoustofluidics-exploiting ultrasonic standing waves, forces and acoustic streaming in microfluidic systems for cell and particle manipulation", we present the theory of surface acoustic waves (SAWs) and some related microfluidic applications. The equations describing SAWs are derived for a solid-vacuum interface before generalisations are made about solid-solid and solid-fluid interfaces. Techniques for SAW generation are discussed before an overview of applications is presented.  相似文献   

5.
Polystyrene (PS), a standard material for cell culture consumable labware, was molded into microstructures with high fidelity of replication by an elastomeric polydimethylsiloxane (PDMS) mold. The process was a simple, benchtop method based on soft lithography using readily available materials. The key to successful replica molding by this simple procedure relies on the use of a solvent, for example, gamma-butyrolactone, which dissolves PS without swelling the PDMS mold. PS solution was added to the PDMS mold, and evaporation of the solvent was accomplished by baking the mold on a hotplate. Microstructures with feature sizes as small as 3 μm and aspect ratios as large as 7 were readily molded. Prototypes of microfluidic chips made from PS were prepared by thermal bonding of a microchannel molded in PS with a flat PS substrate. The PS microfluidic chip displayed much lower adsorption and absorption of hydrophobic molecules (e.g. rhodamine B) compared to a comparable chip created from PDMS. The molded PS surface exhibited stable surface properties after plasma oxidation as assessed by contact angle measurement. The molded, oxidized PS surface remained an excellent surface for cell culture based on cell adhesion and proliferation. To demonstrate the application of this process for cell biology research, PS was micromolded into two different microarray formats, microwells and microposts, for segregation and tracking of non-adherent and adherent cells, respectively. The micromolded PS possessed properties that were ideal for biological and bioanalytical needs, thus making it an alternative material to PDMS and suitable for building lab-on-a-chip devices by soft lithography methods.  相似文献   

6.
Nock V  Blaikie RJ  David T 《Lab on a chip》2008,8(8):1300-1307
This paper describes a process for the layer-by-layer fabrication and integration of luminescent dye-based optical oxygen sensors into microfluidic devices. Application of oxygen-sensitive platinum(ii) octaethylporphyrin ketone fluorescent dye dissolved in polystyrene onto glass substrates by spin-coating was studied. Soft lithography with polydimethylsiloxane (PDMS) stamps and reactive ion etching in oxygen plasma were used to produce sensor patterns with a minimum feature size of 25 microm. Sensors patterns were integrated into a PDMS microfluidic device by plasma bonding. No degradation of the sensor response as a result of the lithography and pattern-transfer processes was detected. Gaseous and dissolved oxygen (DO) detection was characterised using fluorescence microscopy. The intensity signal ratio of the sensor films was found to increase almost two-fold from 3.6 to 6.8 by reducing film thickness from 1.3 microm to 0.6 microm. Calibration of DO measurement showed linear Stern-Volmer behaviour that was constant for flow rates from 0.5 to 2 mL min(-1). The calibrated sensors were subsequently used to demonstrate laterally resolved detection of oxygen inside a microfluidic channel. The fabrication process provides a novel, easy to use method for the repeatable integration of optical oxygen sensors into cell-culture and lab-on-a-chip devices.  相似文献   

7.
Protein adsorption on PDMS surfaces poses a significant challenge in microfluidic devices that come into contact with biofluids such as blood. Polyurethane (PU) is often used for the construction of medical devices, but despite having several attractive properties for biointerfacing, it has not been widely used in microfluidic devices. In this work we developed two new fabrication processes for making thin, transparent and flexible PU-based microfluidic devices. Methods for the fabrication and bonding of microchannels, the integration of fluidic interconnections and surface modification with hydrophilic polyethylene oxide (PEO) to reduce protein adsorption are detailed. Using these processes, microchannels were produced having high transparency (96% that of glass in visible light), high bond strength (326.4 kPa) and low protein adsorption (80% reduction in fibrinogen adsorption vs. unmodified PDMS), which is critical for prevention of fouling. Our findings indicate that PEO modified PU could serve as an effective alternative to PDMS in blood contacting microfluidic applications.  相似文献   

8.
Yuen PK  Su H  Goral VN  Fink KA 《Lab on a chip》2011,11(8):1541-1544
This technical note presents a fabrication method and applications of three-dimensional (3D) interconnected microporous poly(dimethylsiloxane) (PDMS) microfluidic devices. Based on soft lithography, the microporous PDMS microfluidic devices were fabricated by molding a mixture of PDMS pre-polymer and sugar particles in a microstructured mold. After curing and demolding, the sugar particles were dissolved and washed away from the microstructured PDMS replica revealing 3D interconnected microporous structures. Other than introducing microporous structures into the PDMS replica, different sizes of sugar particles can be used to alter the surface wettability of the microporous PDMS replica. Oxygen plasma assisted bonding was used to enclose the microstructured microporous PDMS replica using a non-porous PDMS with inlet and outlet holes. A gas absorption reaction using carbon dioxide (CO(2)) gas acidified water was used to demonstrate the advantages and potential applications of the microporous PDMS microfluidic devices. We demonstrated that the acidification rate in the microporous PDMS microfluidic device was approximately 10 times faster than the non-porous PDMS microfluidic device under similar experimental conditions. The microporous PDMS microfluidic devices can also be used in cell culture applications where gas perfusion can improve cell survival and functions.  相似文献   

9.
《Analytical letters》2012,45(2-3):168-186
The need for simple, rapid, cost-effective, and portable screening methods has boosted the development of practical biosensors with applications in clinical monitoring, and diagnosis of disease. Compared with traditional analytical methods, enzyme-based bioanalytical devices have several distinct advantages such as high sensitivity and specificity, portability, cost-effectiveness, and the possibilities for miniaturization and mass production. Additionally, they can be developed for point-of-care diagnostic testing. This paper reviews recent advances in the development of enzyme biosensors, design characteristics, performances, and applications with a focus on electrochemical and optical sensors. Recent emerging technologies and innovative biosensing designs, such as nanosensors, paper based-sensors, lab-on-a-chip, biochips, and microfluidic devices are discussed. Specific applications in bioanalysis, clinical diagnosis, and pharmacology are discussed.  相似文献   

10.
We demonstrate the use of a phononic crystal to enable the nebulisation of liquid droplets from low-cost disposable arrays, using surface acoustic waves (SAW). The SAWs were generated using interdigitated transducers (IDT) on a piezoelectric surface (LiNbO(3)) and the acoustic waves were coupled into a disposable phononic crystal structure, referred to as a superstrate. Using its excellent reflecting properties, the phononic structures confined the acoustic field within the superstrate, resulting in the concentration of the acoustic energy, in a manner controllable by the excitation frequency. We show that this capability mitigates against coupling losses incurred by the use of a disposable superstrate, greatly reducing the time needed to nebulise a drop of water with respect to an unstructured superstrate for a given power. We also demonstrate that by changing the excitation frequency, it is possible to change the spatial position at which the acoustic energy is concentrated, providing a means to specifically nebulise drops across an array. These results open up a promising future for the use of phonofluidics in high-throughput sample handling applications, such as drug delivery or the "soft" transfer of samples to a mass spectrometer in the field of proteomics.  相似文献   

11.
Cira NJ  Ho JY  Dueck ME  Weibel DB 《Lab on a chip》2012,12(6):1052-1059
This article describes a portable microfluidic technology for determining the minimum inhibitory concentration (MIC) of antibiotics against bacteria. The microfluidic platform consists of a set of chambers molded in poly(dimethylsiloxane) (PDMS) that are preloaded with antibiotic, dried, and reversibly sealed to a second layer of PDMS containing channels that connect the chambers. The assembled device is degassed via vacuum prior to its use, and the absorption of gas by PDMS provides the mechanism for actuating and metering the flow of fluid in the microfluidic channels and chambers. During the operation of the device, degas driven flow introduces a suspension of bacterial cells, dissolves the antibiotic, and isolates cells in individual chambers without cross contamination. The growth of bacteria in the chambers in the presence of a pH indicator produces a colorimetric change that can be detected visually using ambient light. Using this device we measured the MIC of vancomycin, tetracycline, and kanamycin against Enterococcus faecalis 1131, Proteus mirabilis HI4320, Klebsiella pneumoniae, and Escherichia coli MG1655 and report values that are comparable to standard liquid broth dilution measurements. The device provides a simple method for MIC determination of individual antibiotics against human pathogens that will have applications for clinical and point-of-care medicine. Importantly, this device is designed around simplicity: it requires a single pipetting step to introduce the sample, no additional components or external equipment for its operation, and provides a straightforward visual measurement of cell growth. As the device introduces a novel approach for filling and isolating dead-end microfluidic chambers that does not require valves and actuators, this technology should find applications in other portable assays and devices.  相似文献   

12.
We describe a simple and versatile method for bonding thermoplastics to elastomeric polydimethylsiloxane (PDMS) at room temperature. The bonding of various thermoplastics including polycarbonate (PC), cyclic olefin copolymer (COC), polymethylmethacrylate (PMMA), and polystyrene (PS), to PDMS has been demonstrated at room temperature. An irreversible bonding was formed instantaneously when the thermoplastics, activated by oxygen plasma followed by aminopropyltriethoxysilane modification, were brought into contact with the plasma treated PDMS. The surface modified thermoplastics were characterized by water contact angle measurements and X-ray photoelectron spectroscopy. The tensile strength of the bonded hybrid devices fabricated with PC, COC, PMMA, and PS was found to be 430, 432, 385, and 388 kPa, respectively. The assembled devices showed high burst resistance at a maximum channel pressure achievable by an in-house built syringe pump, 528 kPa. Furthermore, they displayed very high hydrolytic stability; no significant change was observed even after the storage in water at 37 °C over a period of three weeks. In addition, this thermoplastic-to-PDMS bonding technique has been successfully employed to fabricate a relatively large sized device. For example, a lab-on-a-disc with a diameter of 12 cm showed no leakage when it spins for centrifugal fluidic pumping at a very high rotating speed of 6000 rpm.  相似文献   

13.
J Wu  G Zheng  LM Lee 《Lab on a chip》2012,12(19):3566-3575
Microfluidic devices have undergone rapid development in recent years and provide a lab-on-a-chip solution for many biomedical and chemical applications. Optical imaging techniques are essential in microfluidics for observing and extracting information from biological or chemical samples. Traditionally, imaging in microfluidics is achieved by bench-top conventional microscopes or other bulky imaging systems. More recently, many novel compact microscopic techniques have been developed to provide a low-cost and portable solution. In this review, we provide an overview of optical imaging techniques used in microfluidics followed with their applications. We first discuss bulky imaging systems including microscopes and interferometer-based techniques, then we focus on compact imaging systems that can be better integrated with microfluidic devices, including digital in-line holography and scanning-based imaging techniques. The applications in biomedicine or chemistry are also discussed along with the specific imaging techniques.  相似文献   

14.
Summary: The behavior of complex polymer structures, e.g., star and comb polymers or shells of polymer micelles, is often studied by dynamic Monte Carlo simulations. The algorithm, which is based on a sequence of independent steps, each of them consisting in dissolving and regrowing a randomly chosen tethered chain by the configuration‐bias Monte Carlo (CBMC) method, is considered. During each step, the remaining self‐avoiding walks (SAWs), which occupy the space, create geometrical restriction for the new SAW and hinder certain conformations. Hence, the reconstruction of the SAW under consideration depends on conformations of the other SAWs forming the system, and therefore, it is not directly evident whether the a priori ergodicity of SAW for a single untethered chain has been retained in the final algorithm for the whole multichain system. The proof of ergodicity of this type of simulations for an arbitrary number of SAWs tethered to the convex core is presented.

2D scheme of the alignment of the SAWs.  相似文献   


15.
PDMS bonding by means of a portable, low-cost corona system   总被引:3,自引:0,他引:3  
Haubert K  Drier T  Beebe D 《Lab on a chip》2006,6(12):1548-1549
A hand-held corona treater is presented as an effective, inexpensive, and portable alternative for irreversible bonding of polydimethylsiloxane (PDMS) to glass.  相似文献   

16.
The use of polydimethylsiloxane (PDMS) in microfluidic devices is extensive in academic research. One of the most fundamental treatments is to expose PDMS to plasma oxidation in order to render its surface temporarily hydrophilic and capable of permanent bonding. Here, we show that changes in the surface chemistry induced by plasma oxidation can spatially be counteracted very cleanly and reliably in a scalable manner by subsequent microcontact printing of residual oligomers from a PDMS stamp. We characterize the surface modifications through contact angle, atomic force microscopy, X-ray photoelectron spectroscopy, and bond-strength measurements. We utilize this approach for negating the bonding of a flexible membrane layer within an elastomeric valve and demonstrate its effectiveness by integration of over one thousand normally closed elastomeric valves within a single substrate. In addition, we demonstrate that surface energy patterning can be used for "open microfluidic" applications that utilize spatial control of surface wetting.  相似文献   

17.
A simple low temperature adhesive 'stamp-and-stick' bonding procedure for lab-on-a-chip glass devices has been tested for capillary electrophoresis applications. This technique involves use of a mask aligner to transfer a UV-curable adhesive selectively onto the top CE substrate which is then aligned with and bonded to the bottom CE wafer. The entire bonding process can be carried out at room temperature in less than 30 minutes, involved only user-friendly laboratory operations, and provided a near 100% success rate. CE microchips made in this manner exhibited similar electroosmotic flow and separation characteristics as ones made via conventional high temperature thermal bonding. Equally important, the devices provided stable long-term performance over weeks of use, encompassing hundreds of individual CE runs without structural failure or any apparent change in operating characteristics. Finally, these devices exhibited excellent chip-to-chip reproducibility. Successful adaptation of the stamp-and-stick approach did require the development and testing of new but easily implemented structural features which were incorporated into the chip design and whose nature is described in detail.  相似文献   

18.
The effects of surface acoustic waves (SAWs) and resonance oscillation (RO) of bulk acoustic waves on catalytic activity and selectivity were studied in an attempt to design a heterogeneous catalyst which has artificially controllable functions for chemical reactions. The propagation of Rayleigh SAW and shear horizontal leaky SAW through thin Pd catalyst films deposited on poled ferroelectric LiNbO3 and LiTaO3 crystals caused considerable activity increases in ethanol oxidation: the enhancement was much larger for the oxidized than the reduced Pd. Similar effects were observed for a Ni catalyst. The RO effects on catalyst activation for ethanol oxidation were associated with the polarized (positive and negative) surfaces and the vibration modes of the ferroelectric substrates. The thickness extension mode resonance oscillation (TERO) of z-cut LiNbO3 caused different changes in the activation energy and reaction order between the positive and negative plane of the LiNbO3 substrate. Different catalyst activation was induced between TERO and the radial extension mode resonance oscillation (RERO) of a Pb0.95Sr0.05Zr0.53Ti0.47O3 ferroelectric substrate. For ethanol decomposition on a Ag catalyst, the TERO of z-cut LiNbO3 increased ethylene production without significant enhancement of acetaldehyde production, thus demonstrating that TERO has the ability to change the selectivity in the catalytic reaction. Large dynamic lattice displacement, surface potential changes, and work function shifts were observed with TERO. A mechanism of acoustic wave excitation effect on the catalyst activation is discussed.  相似文献   

19.
An extremely simple, power-free pumping method for poly(dimethylsiloxane)(PDMS) microfluidic devices is presented. By exploiting the high gas solubility of PDMS, the energy for the pumping is pre-stored in the degassed bulk PDMS, therefore no additional structures other than channels and reservoirs are required. In a Y-shaped microchannel with cross section of 100 microm width x 25 microm height, this method has provided flow rate of 0.5-2 nL s(-1), corresponding to linear velocity of 0.2-0.8 mm s(-1), with good reproducibility. As an application of the power-free pumping, gold nanoparticle-based DNA analysis, which does not rely on the cross-linking mechanism between nanoparticles, has been implemented in a microchannel with three inlets. Target 15mer DNA has been easily and unambiguously discriminated from its single-base substituted mutant. Instead of colorimetric detection in a conventional microtube, an alternative detection technique suitable for microdevices has been discovered-observation of deposition on the PDMS surfaces. The channel layout enabled two simultaneous DNA analyses at the two interfaces between the three laminar streams.  相似文献   

20.
This review offers an overview of the relatively young research area of continuous flow lab-on-a-chip for synthetic applications. A short introduction on the basic aspects of lab-on-a-chip is given in the first part. Subsequently, the effects of downscaling reaction vessels as well as the advantages of the continuous flow microfluidic approach over conventional chemical laboratory batch methodologies are illustrated by a number of examples of organic reactions carried out in microfluidic devices. The last part deals with a key issue of the lab-on-a-chip approach, viz. the integration of the microreactor with the analytical instrumentation to achieve high-throughput reaction monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号