首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A liquid chromatographic mass spectrometric (LC-MS) assay for the quantification of nicotine and cotinine in human specimens was developed. Human serum and urine (100 μL) were subjected to liquid-liquid extraction. For glucuronidated cotinine, serum was alkalinized and hydrolyzed before extraction. The dried samples were reconstituted and run using gradient flow reverse-phase liquid chromatography with MS detection. The ions utilized for quantification of nicotine, cotinine and milrinone (internal standard) were 162.8, 176.9 and 211.9 m/z, respectively. The mean recoveries were over 80% for cotinine and nicotine with excellent linearity between nominal concentrations and peak area ratios, over a wide concentration range. The percentage coefficient of variation and mean error of the inter- and intra-day validations were <15% for nicotine and cotinine. Analysis of serum from cardiac patients receiving amiodarone suggested that a number of patients were either active smokers or exposed to second-hand smoke. Significant concentrations of nicotine and cotinine were measured in the urine of a known smoking volunteer. The method was highly specific, sensitive and applicable as a tool in detecting and monitoring the passive exposure to tobacco smoke using small specimen volumes (0.1 mL).  相似文献   

2.
李明昕  王倩  朱婧  任琳  雍莉  邹晓莉 《色谱》2017,35(8):826-831
建立了测定人尿液中尼古丁和可替宁含量的亲水作用色谱-串联质谱(HILIC-MS/MS)方法。尿样加入尼古丁-d4和可替宁-d3同位素内标后,用水稀释10倍,经过滤后的滤液由超高效液相色谱-串联质谱(UPLC-MS/MS)进行分离分析。采用ACQUITY UPLC~BEH HILIC色谱柱(50 mm×3.0 mm,1.7μm),以甲醇和体积分数为0.1%的氨水为流动相,流速为0.2 mL/min,在电喷雾电离源正离子模式下测定尿液中尼古丁和可替宁的含量,用标准曲线法定量。尼古丁和可替宁在1.0~1 000μg/L范围内线性关系良好,相关系数分别为0.994 9和0.995 8;检出限分别为0.082μg/L和0.077μg/L;定量限分别为0.27μg/L和0.26μg/L;加标回收率分别为90.4%~103.5%和93.0%~104.6%;相对标准偏差分别为4.80%~6.21%和4.22%~7.15%。应用所建立的方法测定了200份尿样,结果表明,吸烟人群尿中尼古丁含量为26.68~854.30μg/L,可替宁含量为36.66~1 191.18μg/L(n=86,M_(nicotine)=76.00μg/L,M_(nicotine)=83.52μg/L,M为中位数);非吸烟人群尿中尼古丁含量为5.08~69.66μg/L,可替宁含量为3.16~28.21μg/L(n=114,Mnicotine=7.53μg/L,M_(nicotine)=3.79μg/L)。该方法快速灵敏,操作简单,适用于尿样中尼古丁和可替宁的批量测定,能满足烟草暴露评价的需要。  相似文献   

3.
A liquid chromatographic-mass spectrometric method for the simultaneous determination of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma was developed and validated. Analytes and deuterated internal standards were extracted from human plasma using solid-phase extraction and analyzed by liquid chromatography/atmospheric pressure chemical ionization-mass spectrometric detection with selected ion monitoring (SIM). Limits of detection and quantification were 1.0 and 2.5 ng/ml, respectively, for all analytes. Linearity ranged from 2.5 to 500 ng/ml of human plasma using a weighting factor of 1/x; correlation coefficients for the calibration curves were > 0.99. Intra- and inter-assay precision and accuracy were < 15.0%. Recoveries were 108.2-110.8% nicotine, 95.8-108.7% cotinine, 90.5-99.5% trans-3'-hydroxycotinine, and 99.5-109.5% norcotinine. The method was also partially validated in bovine serum, owing to the difficulty of obtaining nicotine-free human plasma for the preparation of calibrators and quality control (QC) samples. This method proved to be robust and accurate for the quantification of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma collected in clinical studies of acute nicotine effects on brain activity and on the development of neonates of maternal smokers.  相似文献   

4.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

5.
An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adjusted with phosphate buffer (1.5 mL) containing nicotine-methyl-d3, cotinine-methyl-d3 and trans-3'-hydroxycotinine-methyl-d3 internal standards. For the unconjugated metabolites, an aliquot (800 microL) of the buffered solution was applied to a 30 mg Oasis HLB-SPE column, rinsed with 2% NH4OH/H2O (3.0 mL) and H2O (3.0 mL) and eluted with methanol (500 microL). The eluate was analyzed isocratically (100% methanol) by LC-MS/MS on a diol column (50 x 2.1 mm). For the total metabolites, a beta-glucuronidase/buffer preparation (100 microL) was added to the remaining buffered solution and incubated at 37 degrees C (20 h). An aliquot (800 microL) of the enzymatically treated buffered solution was extracted and analyzed in the same manner. The conjugated metabolites were determined indirectly by subtraction. The quantitation range of the method (ng/mL) was 14-10,320 for nicotine, 15-9800 for cotinine and 32-19,220 for trans-3'-hydroxycotinine. The validated method was used to observe diurnal variations from a smoker's spot urine samples, elimination half-lives from a smoker's 24 h urine samples and metabolite distribution profiles in the spot and 24 h urine samples.  相似文献   

6.
Ding L  Xie F  Xu G  Liu K  Wang S  Xie J 《Journal of separation science》2010,33(21):3429-3436
Integration of normal-phase LC (NPLC) fractionation with RPLC-ESI/MS was established to detect the polar fractions of cuticular components from Oriental tobacco leaf. NPLC was selected for the fractionation of polar components of cuticular leaf extract, after being concentrated with rotary evaporator, each of the enriched fractions was further analyzed by RPLC-ESI/MS. In total, 83 compounds were finally detected including 45 cembranoids, 15 labdanoids, 20 sucrose esters, and 3 glucose esters (or fructose esters). Three cembranoids and seven labdanoids possibly are new diterpenoids. Glucose esters (or fructose esters) are also reported in Nicotiana tobacco for the first time.  相似文献   

7.
Lipid peroxidation process has attracted much attention due to the growing evidence of its involvement in the pathogenesis of age-related diseases. The monitoring of the lipid peroxidation products in phospholipids, formed under oxidative stress conditions, may provide new markers for oxidative stress signaling and for disease states, giving new insights in the pathogenesis process. Reversed-phase liquid chromatographic method coupled to mass spectrometry was developed for the separation of oxidized glycero-phosphatidylcholine (GPC) peroxidation products formed by the Fenton reaction that mimic in vivo oxidative stress conditions. The LC-MS conditions were applied for the separation of peroxidation products of oleoyl- (POPC), lineloyl- (PLPC) and arachidonoyl-palmitoyl phosphatidylcholine (PAPC). The peroxidation products separated included products resulting from the insertion of oxygen atoms in the sn-2 chain (long-chain), and products with the sn-2 chain shortened resulting from cleavage of oxygen-centered radicals (short-chain). Among long-chain products were the keto, hydroxy, hydroperoxide and poly-hydroxy derivatives, while short-chain products included dicarboxylic acids, aldehydes and hydroxy-aldehydes. Separation of long-chain products formed in each phosphatidylcholine was observed, and the reconstructed ion chromatogram of each ion showed an increase in the number of peaks with the increase in the number of oxygen atoms inserted into the phospholipid. Separation of short-chain products took place according to the functional group present at the sn-2 moiety that allowed the elution of dicarboxylic acids distinct from aldehydes. Separation between isomeric structures that were present in short- and long-chain products was also achieved.  相似文献   

8.
A sensitive method with liquid chromatography-electrospray ionization mass spectrometry has been developed and validated for the determination of aristololactam-I in rat plasma after oral administration of aristolochic acid-I using finesteride as the internal standard. Chromatographic separation was achieved on a Lichrospher C(18) column using methanol:0.05% acetic acid in water (71:29, v/v) as a mobile phase delivered at a flow rate of 1 mL/min. The assay was linear for aristololactam-I over the range 0.3-300 ng/mL. The analysis of quality control samples demonstrated precision with coefficient of variation less than 20% (n = 5). Absolute recovery of aristololactam-I was 90.4-97.3%. The LC-MS method for the determination of aristololactam-I is sensitive, specific and can be used to investigate the toxicokinetics of aristololactam-I.  相似文献   

9.
A method of vortex‐assisted dispersive liquid–liquid extraction coupled with gas chromatography and tandem mass spectrometry for the determination of nicotine and cotinine in urine was developed. Response surface methodology was applied to obtain the optimum extraction conditions. In this method, Plackett–Burman design was utilized to evaluate the impact of five selected factors on pretreatment procedure. Then, three main factors were optimized using a Box–Behnken design. The optimized method showed good linearities at 1–2000 μg/L with correlation coefficients of 0.9998 for nicotine and 0.9986 for cotinine. Recovery was 91.4–106 and 91.7–108% for nicotine and cotinine, respectively. The intraday relative standard derivations of determination were 1.47–4.06% for nicotine and 0.41–3.16% for cotinine, and interday relative standard derivations were 3.03–6.70% for nicotine and 1.64–6.38% for cotinine. The method detection limits for nicotine and cotinine were 0.33 and 0.34 μg/L, respectively. A total of 87 urine samples from smokers and nonsmokers were tested with the proposed method. Urinary nicotine and cotinine were 23.0–6.67 × 103 and 18.4–4.17 × 103 μg/(g·cr) for smokers and 1.31–286 and 1.39–131 μg/(g·cr) for nonsmokers, respectively. The method is sensitive, suitable and reliable for the determination of nicotine and cotinine in urine and meets the requirements for evaluating short‐term tobacco exposure.  相似文献   

10.
Through investigation of the metabolism of rhubarb extract by rat intestinal bacteria, a total of 14 components in rhubarb extract were found to be biotransformed. These components included aloe-emodin-O-glucosides, emodin-O-glucosides, chrysophanol-O-glucosides, physcion-O-glucosides and the corresponding aglycones. Rhein also could be biotransformed by rat intestinal bacteria. Twelve major metabolites were detected in the incubation sample. Under ESI tandem mass conditions, the sequential fragmentation patterns of [M H](-) ions were similar to those of free anthraquinones, thus allowing the rapid identification of the metabolites formed in incubation samples. The results suggested that the proposed hydrolysis of glycoside group followed by hydrogenation in quinoid moiety and/or further acetylation was the major biotransformation pathway for these anthraquinone glycosides by rat intestinal bacteria.  相似文献   

11.
Plasma concentrations of nicotine and its active metabolite cotinine are highly correlated with its biological effects. A UHPLC–MS/MS method was developed, validated and applied for nicotine and cotinine analysis in mice plasma. Chromatographic separation was achieved on a BEH HILIC column using acetonitrile (0.1% formic acid) and 10 mm ammonium formate as mobile phase. The gradient elution was performed at 0.4 mL/min with a run time of 3.6 min. The quantitative ion transition was m/z 163.1 > 130.0 for nicotine, m/z 177.1 > 80.0 for cotinine and m/z 167.1 > 134.0 for nicotine‐D4 (internal standard, IS). For both nicotine and cotinine, the calibration range was 5–500 ng/mL with 5 ng/mL as the lower limit of quantitation, and the intra‐ and inter‐day bias and imprecision were ?4.61–12.00% and <11.12%. The IS normalized recovery was 90.62–98.95% for nicotine and 89.18–101.53% for cotinine, and the IS normalized matrix factor was 106.00–116.44% for nicotine and 100.34–109.85% for cotinine. Both nicotine and cotinine were stable under conventional storage conditions. The validated method has been applied to a pharmacokinetic study in mice to calculate the pharmacokinetic parameters for both analytes.  相似文献   

12.
A method for the determination of ethyl glucuronide (EtG) in hair samples, using liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS), was developed and validated. The treatment of hair samples was as follows: to 100 mg of washed (dichloromethane followed by methanol, 1 ml each) and cut (1-2 mm) material, 700 microl of water, 20 microl of internal standard solution (pentadeuterated EtG, D(5)-EtG, 500 microg/l) and 20 microl of methanol were added. Samples were incubated at 25 degrees C overnight and then ultrasonicated for 2 h. Finally, 8 microl of the centrifuged solution (13,000 rpm) were analyzed by LC/ESI-MS/MS in negative ion mode. The surviving ions of EtG and D(5)-EtG were monitored together with the following MRM transitions: m/z 221 --> 75, m/z 221 --> 85 (EtG) and m/z 226 --> 75, m/z 226 --> 85 (D(5)-EtG). The method exhibited a mean correlation coefficient better than 0.9998 over the dynamic range (3-2000 pg/mg). The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 3 and 2 pg/mg respectively. The intra- and interday precision and accuracy were studied at four different concentration levels (3, 5, 56 and 160 pg/mg) and were always better than 7% (n = 5). Matrix effects did not exceed 20%. The method was applied to several hair samples taken from autopsies of known alcoholics, from patients in withdrawal treatment, from social drinkers, from adult teetotalers and from children not exposed to ethanol, with EtG concentrations globally ranging from < or =2 to 4180 pg/mg.  相似文献   

13.
Sugarcane (Saccharum officinarum L., Gramineae) bagasse and leaves were investigated for their flavonoid content and transgenic sugarcane ("Bowman-Birk" and "Kunitz") was compared with non-modified ("control") plants. Analyses were carried out by high-performance liquid chromatography coupled to diode array UV detection (LC/UV), also using post-column addition of shift reagents, and tandem MS (atmospheric pressure chemical ionization-MS/MS and collision-induced dissociation-MS). On-line UV and MS data demonstrated the presence of methoxyflavone glycosides and aglycones in a total of seven compounds. Three naturally occurring flavones glycosides and two unusual erythro- and threo-diastereoisomeric flavolignan 7-O-glucosides were identified together with their aglycones.  相似文献   

14.
A simple, rapid and sensitive liquid chromatography/electrospray tandem mass spectrometry (LC-MS/MS) quantitative detection method, using cefalexin as internal standard, was developed for the analysis of faropenem in human plasma and urine. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a C18 reversed-phase column with 0.1% formic acid-methanol (45:55, v/v) and detected by electrospray ionization mass spectrometry in positive multiple reaction monitoring mode. Calibration curves with good linearities (r=0.9991 for plasma sample and r=0.9993 for urine sample) were obtained in the range 5-4000 ng/mL for faropenem. The limit of detection was 5 ng/mL. Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of faropenem in humans, and to our knowledge, it is the first time the pharmacokinetic of faropenem has been elucidated in vivo using LC-MS/MS.  相似文献   

15.
A liquid chromatographic-mass spectrometry (LC/MS) assay method was developed for the determination of amiodarone and desethylamiodarone in rat specimens. Analytes were extracted using liquid-liquid extraction in hexane. The LC/MS system consisted of a Waters Micromass ZQtrade mark 4000 spectrometer with an autosampler and pump. A C(18) 3.5 microm (2.1 x 50 mm) column heated to 45 degrees C was used for separation. The mobile phase consisted of methanol and 0.2% aqueous formic acid pumped at 0.2 mL/min as a linear gradient. Components eluted within 12 min. The concentrations of ethopropazine (internal standard), desethylamiodarone and amiodarone were monitored for m/z of 313.10, combination of 546.9 and 617.73, and 645.83, respectively. In plasma (0.1 mL), linearity was achieved between the peak area ratios and concentrations over the range of 2.5-1000 ng/mL for both amiodarone and desethylamiodarone (r(2) > 0.999). The intraday and interday CV were equal or less than 18%, and mean error was <12%. Similarly, in homogenates containing 0.1 g of rat tissue, linearity was observed in standards ranging from 5 to 5000 ng/g. The method was successfully used to measure tissue and plasma concentrations of drug. The validated lower limit of quantitation was 2.5 ng/mL for drug and metabolite, based on 0.1 mL of plasma.  相似文献   

16.
Summary Thermospray liquid chromatography-mass spectrometry has been applied to the identification of by-products in precolumn derivatization by phenylisocyanate. These byproducts are eluted early in the same chromatographic region as the low molecular weight derivatives and were located by chromatographic analysis of a blank sample. Their identification would offer further qualitative information in the use of phenylisocyanate as a derivatizing agent. Five compounds resulted from the reaction of phenylisocyanate and the reaction medium were identified: two from a reaction between phenylisocyanate and methanol, two from the reaction between phenylisocyanate and water, and one from the polymerisation of phenylisocyanate.  相似文献   

17.
18.
The sensitivity of glycan analysis using nano-liquid chromatography interfaced with electrospray ionization mass spectrometry (ESI-MS) increases with the decrease of the mobile phase flow rate, accompanied by reduced ion suppression. In this study, we describe the preparation and performance of high efficiency 10 microm I.D. amine-bonded poly(vinylbenzyl chloride-divinylbenzene) hydrophilic interaction (HILIC) porous layer open tubular (PLOT) columns operated at 20 nL/min for the separation and analysis of glycan mixtures. HILIC-PLOT columns with a uniform porous polymer layer were reproducibly prepared ( approximately 4% RSD in retention time from column-to-column) via in situ polymerization, followed by one step modification with ethylenediamine. When coupled on-line with negative ESI-MS, low detection limits (0.3fmol) for a 3-sialyl-tetrasaccharide were achieved using a 2.5mx10 microm I.D. HILIC-PLOT column. A dextran ladder standard was used to evaluate the performance of the column, and high efficiency separation was achieved with detection of the dextrans up to G22 from approximately 50 fmol amounts injected. As an example of the high sensitivity of the column, MS(6) characterization of glycan structures was possible from the injection of 10 fmol of a neutral and sialylated glycan. As another example of high sensitivity LC-MS analysis of 3 ng of a PNGase F digest of ovalbumin allowed 28 N-linked glycans to be confidently identified from a single analysis. High quality MS/MS spectra for each ovalbumin glycan were acquired and manually interpreted for structure analysis. The HILIC-PLOT column is a very promising approach for LC-MS analysis of glycans at the ultratrace level.  相似文献   

19.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

20.
Temperature was investigated as active parameter in the liquid chromatography (LC) analysis of octylphenol ethoxylates. Significant differences in selectivity were observed when the oligomers were analyzed by reversed phase LC (RPLC) on silica-, zirconia- and polystyrene/divinylbenzene based stationary phases at low (ambient), medium and elevated temperature with acetonitrile/water as mobile phase. As ascertained by LC-mass spectroscopy (MS), in most cases the elution order of the oligomers was completely reversed comparing ambient and high temperature separations. On a graphitized carbon type column, the selectivity remained unchanged, regardless the analysis temperature. Also in normal phase LC, the elution order remained unaffected by temperature variations both for acetonitrile/water and methanol/water mixtures as mobile phase. Surprisingly, when reversed phase LC on a octadecylsilicagel column at different temperatures was repeated with methanol instead of acetonitrile as mobile phase ingredient, the reversal of elution order did not take place. Results are evaluated in terms of thermodynamic parameters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号