1.
Naji OP  Manz A 《Lab on a chip》2004,4(5):431-437
A direct-current, chip-based plasma has been used for gas sample injection in gas chromatography. A second identical plasma chip has been used as the excitation source for an optical emission detector. The first plasma is normally continually sustained during operation, causing continuous ionisation/fragmentation of the sample, whilst the second plasma records the optical emission downstream. For injection, the first plasma is briefly interrupted, introducing a "plug" of unmodified sample into the system. Injection plug sizes of between 5 and 50 [micro sign]l have been reproducibly obtained, although significantly smaller volumes may be possible with the use of smaller cross-section columns, lower flow rates and/or shorter plasma interruption times.  相似文献   

2.
The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injection plug peak widths were consistent for plug hold times as long as the 8 min maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.  相似文献   

3.
Wu W  Kang KT  Lee NY 《The Analyst》2011,136(11):2287-2293
Bubble formation inside a microscale channel is a significant problem in general microfluidic experiments. The problem becomes especially crucial when performing a polymerase chain reaction (PCR) on a chip which is subject to repetitive temperature changes. In this paper, we propose a bubble-free sample injection scheme applicable for continuous-flow PCR inside a glass/PDMS hybrid microfluidic chip, and attempt to provide a theoretical basis concerning bubble formation and elimination. Highly viscous paraffin oil plugs are employed in both the anterior and posterior ends of a sample plug, completely encapsulating the sample and eliminating possible nucleation sites for bubbles. In this way, internal channel pressure is increased, and vaporization of the sample is prevented, suppressing bubble formation. Use of an oil plug in the posterior end of the sample plug aids in maintaining a stable flow of a sample at a constant rate inside a heated microchannel throughout the entire reaction, as compared to using an air plug. By adopting the proposed sample injection scheme, we demonstrate various practical applications. On-chip continuous-flow PCR is performed employing genomic DNA extracted from a clinical single hair root sample, and its D1S80 locus is successfully amplified. Also, chip reusability is assessed using a plasmid vector. A single chip is used up to 10 times repeatedly without being destroyed, maintaining almost equal intensities of the resulting amplicons after each run, ensuring the reliability and reproducibility of the proposed sample injection scheme. In addition, the use of a commercially-available and highly cost-effective hot plate as a potential candidate for the heating source is investigated.  相似文献   

4.
Jia Z  Lee YK  Fang Q  Huie CW 《Electrophoresis》2006,27(5-6):1104-1111
A mismatch in the EOF velocities between the sample zone and running buffer region is known to generate pressure-driven, parabolic flow profile of the sample plug in electrokinetic separation systems. In the present study, video fluorescence microscopy was employed to capture real-time dynamics of the sample plug (containing fluorescein as the probe molecule) in a discontinuous conductivity system within a glass microchip, in which the sample matrix consisted of a mixture of ACN and salt (NaCl), and the running buffer contained sodium cholate (SC) micelles as the pseudo-stationary phase (i.e., performing "ACN stacking" in the mode of MEKC). Upon application of the separation voltage, the video images revealed that zone narrowing and broadening of the probe molecules occurred as the sample plug headed toward the cathode during the initial time period, probably resulting in part from the stacking/sweeping, and destacking of the SC micelles at the boundaries between the sample zone and running buffer. Interestingly, a second sample zone narrowing event can be observed as the sample plug moved further toward the cathode, which could be attributed to the sweeping of the slower moving probe molecules by the faster moving SC micelles that originated from the anode. This phenomenon was studied as a function of pH, sample plug length, as well as the concentration of organic solvent and salt in the sample matrix. The data suggested that the presence of large amounts of an organic solvent (such as ACN or methanol) and salts in the sample matrix not only induces sample dispersion due to the formation of a pressure-driven (hydrodynamic) flow, but may also lead to the formation of a double sample zone narrowing phenomenon by altering the local EOF dynamics within the separation system.  相似文献   

5.
The double-T injector design employed in many microchip capillary electrophoresis devices allows for the formation of very small (50-500 pL) sample plugs for subsequent analysis on-chip. In this study, we show that sample plugs formed at the channel junction can be geometrically defined. The channel width and injector symmetry prove to be of great importance to good performance. A unique pushback of solvent into the side channels can be induced when the side channels have a very low resistance to flow, and this helps to better define the injected sample plug. Samples and running buffers of differing ionic strength (e.g., 10 mM KCl buffer and 20 mM KCl sample) can yield widely variable results in terms of plug shape and amount injected (variations of 1.5 to 10x). Applying bias voltages to all the intersecting channels aids in controlling the plug shape. However, when the ionic strengths of buffer and sample are not matched, the actual amount injected (up to 10x variations) can be inconsistent with the appearance of the plug formed in the injector (up to only 30 % variations). Operating at constant pH and ionic strength produced the most consistent results. This report examines the effects of altering the injector geometry and solution ionic strengths, and presents the results of using bias voltages to control plug formation. The observed results should provide a benchmark for modeling of the fluid dynamics in channel intersections.  相似文献   

6.
Thermal decomposition of some hydrocarbon and chlorinated hydrocarbon compounds in metal capillary tubes used in an inlet system for high speed gas chromatography has been investigated. The metal tube is cooled to about ?75°C by a flow of cold nitrogen gas in order to focus a vapor sample cryogenically. A capacitive discharge power supply is then used to heat the metal tube resistively in order to revaporize the sample and introduce it to the separation column as a plug 5-10 ms wide. The effects of tube temperature, tube material, sample vapor residence time, and type of carrier gas on thermal cracking are described. Use of a copper-nickel alloy tube resulted in less cracking than either pure platinum or pure nickel. Cracking is more significant with hydrogen as carrier gas than with helium. Cracking also increases with increasing sample residence time in the hot tube. Quantitative sample injection with minimum decomposition can be obtained for a variety of aliphatic and aromatic hydrocarbons and chlorinated hydrocarbon compounds.  相似文献   

7.
Sample inlet splitters are used in capillary column gas chromatography. We have investigated the sample band broadening in the splitter and studied reproducibility and accuracy in quantitative analysis using a simple lab-made splitter. It was found that the results were dependent upon the operating conditions such as split ratio, splitter temperature, glass wool plug, injected sample volume and solvent.  相似文献   

8.
The procedure for the preconcentration and determination of isopropyl-methylphosphonofluoridate (Sarin) involves extraction of the sample with chloroform, preconcentration of the vaporized extract on a Porapak Q plug, and direct thermal desorption of the adsorbed material into a gas chromatograph. Precise determinations at concentrations down to approximately 67 pg ml-1 are possible.  相似文献   

9.
We developed an immune microanalysis system incorporating chemiluminescence detection, where the peroxyoxalate chemiluminescence (CL) detection using bis[4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate (TDPO)-hydrogen peroxide (H2O2)-fluorescein isothiocianate (FITC) reaction was newly adopted. The analysis system performed the following three processes on a microchip: immune reaction for high selectivity, electrophoresis for formation and transportation of the sample plug, and CL detection. The immune reaction was carried out using an antibody-immobilized glass bead. The glass bead was placed in one of the reservoirs in the microchip along with antigen (analyte) and a known amount of FITC-labeled antigen to set up a competitive immune reaction. The reactant after the immune reaction was fed electrophoretically into the intersection, resulting in a sample plug. The sample plug was then moved into another reservoir containing TDPO-H2O2 acetonitrile solution. At this point, CL detection was performed. The system described here was capable of determining human serum albumin or immunosuppressive acidic protein as a cancer marker in human serum.  相似文献   

10.
A flow controlled adjustable splitter was configured from a Deans switch and employed in an automated dual column gas chromatographic (GC) system for analyzing mono-aromatic compounds. Volatile organic compounds (VOCs), thermally desorbed from the sorbent trap, were split by the adjustable splitter onto two columns of different phases for separation and then detection by flame ionization detection (FID). Unlike regular splitters in which the split ratio is passively determined by the diameter and/or length of the connecting columns or tubing, the split ratio in our adjustable splitter is controlled by the auxiliary flow in the Deans switch. The auxiliary flow serves as a gas plug on either side of the column for decreasing the sample flow in one transfer line, but increasing the flow in the other. By adjusting the auxiliary flow and therefore the size of the gas plug, the split ratio can be easily varied and favorable to the side of no auxiliary gas. As an illustration, two columns, DB-1 and Cyclodex-B, were employed in this study for separating benzene, toluene, ethylbenzene, xylenes, denoted as BTEX, in particular the structural isomers of o-, m-, p-xylenes. This configuration demonstrates that BTEX cannot be fully separated with either column, but can be deconvoluted by simple algebra if dual columns are used with a splitter. The applicability of the proposed concept was tested by analyzing a gas standard containing BTEX at different split ratios and with various sample sizes, all leading to a constant ratio of m-xylene versus p-xylene.  相似文献   

11.
A sequential injection analysis (SIA) system is coupled with dynamic surface tension detection (DSTD) for the purpose of studying the interfacial properties of surface-active samples. DSTD is a novel analyzer based upon a growing drop method, utilizing a pressure sensor measurement of drop pressure. The pressure signal depends on the surface tension properties of sample solution drops that grow and detach at the end of a capillary tip. In this work, SIA was used for creating a reagent concentration gradient, and for blending the reagent gradient with a steady-state sample. The sample, consisting of either sodium dodecyl sulfate (SDS) or poly(ethylene glycol) at 1470 g mol−1 (PEG 1470), elutes with a steady-state concentration at the center of the sample plug. Reagents such as Brij®35, tetrabutylammonium (TBA) hydroxide and β-cyclodextrin were introduced as a concentration gradient that begins after the sample plug has reached the steady-state concentration. By blending the reagent concentration gradient with the sample plug using SIA/DSTD, the kinetic surface pressure signal of samples mixed with various reagent concentrations is observed and evaluated in a high throughput fashion. It was found that the SIA/DSTD method consumes lesser reagent and required significantly less analysis time than traditional FIA/DSTD. Four unique chemical systems were studied with regard to how surface activity is influenced, as observed through the surface tension signal: surface activity addition, surface activity reduction due to competition, surface activity enhancement due to ion-pair formation, and surface activity reduction due to bulk phase binding chemistry.  相似文献   

12.
Contrary to the thermodynamic inhibiting effect of methanol on methane hydrate formation from aqueous phases, hydrate forms quickly at high yield by exposing frozen water–methanol mixtures with methanol concentrations ranging from 0.6–10 wt % to methane gas at pressures from 125 bars at 253 K. Formation rates are some two orders of magnitude greater than those obtained for samples without methanol and conversion of ice is essentially complete. Ammonia has a similar catalytic effect when used in concentrations of 0.3–2.7 wt %. The structure I methane hydrate formed in this manner was characterized by powder X‐ray diffraction and Raman spectroscopy. Steps in the possible mechanism of action of methanol were studied with molecular dynamics simulations of the Ih (0001) basal plane exposed to methanol and methane gas. Simulations show that methanol from a surface aqueous layer slowly migrates into the ice lattice. Methane gas is preferentially adsorbed into the aqueous methanol surface layer. Possible consequences of the catalytic methane hydrate formation on hydrate plug formation in gas pipelines, on large scale energy‐efficient gas hydrate formation, and in planetary science are discussed.  相似文献   

13.
Gas hydrates are ice-like crystalline compounds, which form through a combination of water and suitably sized guest molecules under low temperature and elevated pressure conditions. These solid compounds give rise to problems in the natural gas oil industry because they can plug pipelines and process equipment. Low dosage hydrate inhibitors are a recently developed hydrate control technology, which can be more cost-effective than traditional practices such as methanol and glycols. The kinetics of hydrate growth has been modeled by numerous authors who have measured the gas consumption rate during hydrate formation in batch agitator reactors.  相似文献   

14.
Zhuang GS  Li G  Jin QH  Zhao JL  Yang MS 《Electrophoresis》2006,27(24):5009-5019
The injection techniques in electrophoresis microchips play an important role in the sample-handling process, whose characteristics determine the separation performance achieved, and the shape of a sample plug delivered into the separation channel has a great impact on the high-quality separation performance as well. This paper describes a numerical investigation of different electrokinetic injection techniques to deliver a sample plug within electrophoresis microchips. A novel double-focusing injection system is designed and fabricated, which involves four accessory arm channels in which symmetrical focusing potentials are loaded to form a unique parallel electric field distribution in the intersection of injection channel and separation channel. The parallel electric field effectuates virtual walls to confine the spreading of a sample plug at the intersection and prevents sample leakage into separation channel during the dispensing step. The key features of this technique over other injection techniques are the abilities to generate regular and nondistorted shape of sample plugs and deliver the variable-volume sample plugs by electrokinetic focusing. The detection peak in the proposed injection system is uniform regardless of the position of the detection probe in the separation channel, and the peak resolution is greatly enhanced. Finally, the double-focusing injection technique shows the flexibility in detection position and ensures improved signal sensitivity with good peak resolution due to the delivered high-quality sample plug.  相似文献   

15.
An enzymatic stopped-flow injection method for the determination of oxalate is proposed. Two sequential haltings of the flow are made, the first while the sample plug is in a reactor packed with controlled-pore glass and immobilized oxalate decarboxylase, and the second on merging of the sample plug with a stream containing an auxiliary enzyme (formate dehydrogenase) as the plug reaches the flow cell, where absorbance-time data are collected. The linear range of the calibration graphs is between 0.1 and 3.0 mM oxalate and their sensitivity depends on the interval over which measurements are made. The proposed method was applied to the determination of oxalate in urine without separation of the analyte by precipitation, with excellent results.  相似文献   

16.
We developed a novel single‐step capillary electrophoresis (SSCE) scheme for miniaturized and easy to use system by using a microchannel chip, which was made from the hydrophilic material polymethyl methacrylate (PMMA), equipped with a capillary stop valve. Taking the surface tension property of liquids into consideration, the capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure in the wall of the microchannel. Through the combined action of stop valves and air vents, both sample plug formation for electrophoresis and sample injection into a separation channel were successfully performed in a single step. To optimize SSCE, different stop valve structures were evaluated using actual microchannel chips and the finite element method with the level set method. A partial barrier structure at the bottom of the channel functioned efficiently as a stop valve. The stability of stop valve was confirmed by a shock test, which was performed by dropping the microchannel chip to a floor. Sample plug deformation could be reduced by minimizing the size of the side partial barrier. By dissolving hydroxyl ethyl cellulose and using it as the sample solution, the EOF and adsorption of the sample into the PMMA microchannel were successfully reduced. Using this method, a 100‐bp DNA ladder was concentrated; good separation was observed within 1 min. At a separation length of 5 mm, the signal was approximately 20‐fold higher than a signal of original sample solution by field‐amplified sample stacking effect. All operations, including liquid introduction and sample separation, can be completed within 2 min by using the SSCE scheme.  相似文献   

17.
Effects of the electric field distribution on microchip valving performance   总被引:2,自引:0,他引:2  
Valving characteristics on microfluidic devices were controlled through manipulation of the electric field strengths during both the sample loading and dispensing steps. Three sample loading profiles for the constant volume valve (pinched injection) in conjunction with four dispensing schemes were investigated to study valving performance. The sample confinement profiles for the sample loading step consisted of a weakly pinched sample, a medium pinched sample, and a strongly pinched sample. Four dispensing schemes varied the electric field strengths in the sample and sample waste channels relative to the analysis channel to control the volume of the sample dispensed from the valve. The axial extent of the sample plug decreased as the electric field strengths in the sample and sample waste channels were raised relative to the analysis channel. In addition, a trade-off existed between sample plug length and sensitivity.  相似文献   

18.
A microchip structure for field amplification stacking (FAS) was developed, which allowed the formation of comparatively long, volumetrically defined sample plugs with a minimal electrophoretic bias. Up to 20-fold signal gains were achieved by injection and separation of 400 microm long plugs in a 7.5 cm long channel. We studied fluidic effects arising when solutions with mismatched ionic strengths are electrokinetically handled on microchips. In particular, the generation of pressure-driven Poiseuille flow effects in the capillary system due to different electroosmotic flow velocities in adjacent solution zones could clearly be observed by video imaging. The formation of a sample plug, stacking of the analyte and subsequent release into the separation column showed that careful control of electric fields in the side channels of the injection element is essential. To further improve the signal gain, a new chip layout was developed for full-column stacking with subsequent sample matrix removal by polarity switching. The design features a coupled-column structure with separate stacking and capillary electrophoresis (CE) channels, showing signal enhancements of up to 65-fold for a 69 mm long stacking channel.  相似文献   

19.
This work evaluates the use of a competitive binding assay using flow-through partial-filling affinity capillary electrophoresis (FTPFACE) to estimate binding constants of neutral ligands to a receptor. We demonstrate this technique using, as a model system, carbonic anhydrase B (CAB, EC 4.2.1.1) and arylsulfonamides. In this technique, the capillary is first partially filled with a negatively charged ligand, a sample containing CAB and two noninteracting standards, and a neutral ligand, then electrophoresed. Upon application of a voltage the sample plug migrates into the plug of negatively charged ligand (L(-)) resulting in the formation of a CAB-L(-) complex. Continued electrophoresis results in mixing between the neutral ligand (L(0)) and the CAB-L(-) complex. L(0) successfully competes out L(-) to form the new CAB-L(0) complex. Analysis of the change in the relative migration time ratio (RMTR) of CAB relative to the noninteracting standards, as a function of neutral ligand concentration, yields a value for the binding constant. These values are in agreement with those estimated using other binding and ACE techniques. Data demonstrating the quantitative potential of this method is presented.  相似文献   

20.
Yamane T  Saito M 《Talanta》1992,39(3):215-219
A blank peak effect in FIA systems often found for samples containing an excess of solute other than the analyte has been studied. Emphasis has been given to trace level determinations and a simple approach for elimination of this effect is presented. The present approach is based on the use of a large sample injection volume, which results in a portion of the sample plug being undiluted with carrier and hence prevents the formation of refractive index gradients in the undiluted portion. The quantitative performance of this approach was demonstrated with the determination of iron in the presence of 0.20M sodium chloride and cobalt in the presence of 0.10M glucose. No significant difference in the accuracy, precision, and limit of detection was observed between samples for iron both in the presence and absence of sodium chloride and for cobalt in the presence and absence of glucose. Despite using a large sample volume (0.89 ml for a 400-cm sample loop), the sample throughput was about 25/hr.  相似文献   