首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new chelating resin, Xylenol Orange coated Amberlite XAD-7, was prepared and used for preconcentration of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) prior to their determination by flame atomic absorption spectrophotometry. The optimum pH values for quantitative sorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) are 4.5-5.0, 4.5, 4.0-5.0, 4.0, 5.0 and 5.0-7.0, respectively, and their desorptions by 2 mol L(-1) HCl are instantaneous. The sorption capacity of the resin has been found to be 2.0, 2.6, 1.6, 1.6, 2.6 and 1.8 mg g(-1) of resin for Cd, Co, Cu, Fe, Ni and Zn, respectively. The tolerance limits of electrolytes, NaCl, NaF, NaI, NaNO3, Na2SO4 and of cations, Mg2+ and Ca2+ in the sorption of the six metal ions are reported. The preconcentration factor was between 50 and 200. The t1/2 values for sorption are found to be 5.3, 2.9, 3.2, 3.3, 2.5 and 2.6 min for the six metals, respectively. The recoveries are between 96.0 and 100.0% for the different metals at preconcentration limits between 10 to 40 ng mL(-1). The preconcentration method has been applied to determine the six metal ions in river water samples after destroying the organic matter (if present in very large amount) with concentrated nitric acid (RSD < or = 8%, except for Cd for which it is upto 12.6%) and cobalt content of vitamin tablets with RSD of approximately 3.0%.  相似文献   

2.
A new chelating resin, 1-(2-pyridylazo)-2-naphthol (PAN) coated Amberlite XAD-1180 (AXAD-1180), was prepared and used for the preconcentration of Cd(II), Mn(II), Ni(II), Pb(II) and Zn(II) ions prior to their determination by flame atomic absorption spectrometry (FAAS). The optimum pH for simultaneous retention of the elements and the best elution means for their simultaneous elution were pH 9.5 and 3 M HNO3, respectively. The sorption capacity of the resin was found to be 5.3 mg/g for Cd and 3.7 mg/g for Ni. The detection limits for Cd(II), Mn(II), Ni(II), Pb(II) and Zn(II) were 0.7, 10, 3.1, 29 and 0.8 μg/L, respectively. The effects of interfering ions for quantitative sorption of the metal ions were investigated. The preconcentration factors of the method were in the range of 10–30. The recoveries obtained were quantitative (≥95%). The standard reference material (GBW07605 Tea sample) was analysed for accuracy of the described method. The proposed method was successfully applied to the analysis of various water, urea fertilizer and tea samples. The article is published in the original.  相似文献   

3.
A new chelating resin, Xylenol Orange coated Amberlite XAD-7, was prepared and used for preconcentration of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) prior to their determination by flame atomic absorption spectrophotometry. The optimum pH values for quantitative sorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) are 4.5–5.0, 4.5, 4.0–5.0, 4.0, 5.0 and 5.0–7.0, respectively, and their desorptions by 2 mol L–1 HCl are instantaneous. The sorption capacity of the resin has been found to be 2.0, 2.6, 1.6, 1.6, 2.6 and 1.8 mg g–1 of resin for Cd, Co, Cu, Fe, Ni and Zn, respectively. The tolerance limits of electrolytes, NaCl, NaF, NaI, NaNO3, Na2SO4 and of cations, Mg2+ and Ca2+ in the sorption of the six metal ions are reported. The preconcentration factor was between 50 and 200. The t1/2 values for sorption are found to be 5.3, 2.9, 3.2, 3.3, 2.5 and 2.6 min for the six metals, respectively. The recoveries are between 96.0 and 100.0% for the different metals at preconcentration limits between 10 to 40 ng mL–1. The preconcentration method has been applied to determine the six metal ions in river water samples after destroying the organic matter (if present in very large amount) with concentrated nitric acid (RSD ≤ 8%, except for Cd for which it is upto 12.6%) and cobalt content of vitamin tablets with RSD of ~ 3.0%.  相似文献   

4.
Prabhakaran D  Subramanian MS 《Talanta》2003,59(6):1227-1236
A new chelating polymeric sorbent was developed by functionalizing Amberlite XAD-16 with 1,3-dimethyl-3-aminopropan-1-ol via a simple condensation mechanism. The newly developed chelating matrix offered a high resin capacity and faster sorption kinetics for the metal ions such as Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II). Various physio-chemical parameters like pH-effect, kinetics, eluant volume and flow rate, sample breakthrough volume, matrix interference effect on the metal ion sorption have been studied. The optimum pH range for the sorption of the above mentioned metal ions were 6.0–7.5, 6.0–7.0, 8.0–8.5, 7.0–7.5, 6.5–7.5, 7.5–8.5 and 6.5–7.0, respectively. The resin capacities for Mn(II), Pb(II), Ni(II), Co(II), Cu(II), Cd(II) and Zn(II) were found to be 0.62, 0.23, 0.55, 0.27, 0.46, 0.21 and 0.25 mmol g−1 of the resin, respectively. The lower limit of detection was 10 ng ml−1 for Cd(II), 40 ng ml−1 for Mn(II) and Zn(II), 32 ng ml−1 for Ni(II), 25 ng ml−1 for Cu(II) and Co(II) and 20 ng ml−1 for Pb(II). A high preconcentration value of 300 in the case of Mn(II), Co(II), Ni(II), Cu(II),Cd(II) and a value of 500 and 250 for Pb(II) and Zn(II), respectively, were achieved. A recovery of >98% was obtained for all the metal ions with 4 M HCl as eluting agent except in the case of Cu(II) where in 6 M HCl was necessary. The chelating polymer showed low sorption behavior to alkali and alkaline earth metals and also to various inorganic anionic species present in saline matrix. The method was applied for metal ion determination from water samples like seawater, well water and tap water and also from green leafy vegetable, from certified multivitamin tablets and steel samples.  相似文献   

5.
Xie F  Lin X  Wu X  Xie Z 《Talanta》2008,74(4):836-843
The immobilization of gallic acid on the surface of amino group-containing silica gel phases for the formation of a newly chelating matrix (GASG) is described. The newly synthesized extractant, characterized by the diffuse reflectance infrared Fourier transformation spectroscopy and elemental analysis, was used to preconcentrate Pb(II), Cu(II), Cd(II) and Ni(II). The pH ranges for quantitative sorption and the concentrations of HCl for eluting Pb(II), Cd(II), Cu(II) and Ni(II) were opimized, respectively. The sorption capacity of the matrix has been found to be 12.63, 6.09, 15.38, 4.62mg/g for Pb(II), Cd(II), Cu(II) and Ni(II), respectively, with the preconcentration factor of approximately 200 ( approximately 100 for Cd(II)). The effects of flow rates, the eluants, the electrolytes and cations on the metal ions extraction, as well as the chelating matrix stability and reusability, were also studied. The extraction behavior of the matrix was conformed with Langmuir's equation. The present preconcentration and determination method was successfully applied to the analysis of synthetic metal mixture solution and river water samples. The 3sigma detection limit and 10sigma quantification limit for Pb(II), Cu(II), Cd(II) and Ni(II) were found to be 0.58, 0.86, 0.65, 0.92microg/L and 1.08, 1.23, 0.87, 1.26microg/L, respectively.  相似文献   

6.
Solvent extraction of metals with potassium-dihydro-bispyrazolyl-borate   总被引:1,自引:0,他引:1  
Shukla R  Rao GN 《Talanta》2002,57(4):633-639
The extraction of Cu(II), Ni(II), Co(II), Cd(II), Zn(II), Pb(II) and Mn(II) with potassium-dihydro-bispyrazolyl-borate (H(2)BPz(2)(-)) in dichloromethane has been studied. Extraction constants (logK(ex)) have been calculated for all metal systems and were compared with those obtained with dibenzoylmethane (DBM), thenoyltrifluoroacetone (HTTA) and 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (HPMBP). The method has been used for the determination of Cu(II), Co(II), Cd(II), Zn(II), Pb(II) and Mn(II) in standard alloys and for preconcentration of metal ions in synthetic samples.  相似文献   

7.
Silica gel chemically bonded with aminothioamidoanthraquinone was synthesized and characterized. The metal sorption properties of modified silica were studied towards Pb(II), Cu(II), Ni(II), Co(II) and Cd(II). The determination of metal ions was carried out on FAAS. For batch method, the optimum pH ranges for Pb(II), Cu(II) and Cd(II) extraction were ≥3 but for Ni(II) and Co(II) extraction were ≥4. The contact times to reach the equilibrium were less than 10 min. The adsorption isotherm fitted the Langmuir's model showed the maximum sorption capacities of 0.56, 0.30, 0.15, 0.12 and 0.067 mmol/g for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively. In the flow system, a column packed modified silica at 20 mg for Pb(II) and Cu(II), 50 mg for Cd(II), 60 mg for Co(II), Ni(II) was studied at a flow rate of 4 and 2.5 mL/min for Ni(II). The sorbed metals were quantitatively eluted by 1% HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl and SO42− at 10, 100 and 1000 mg/L was observed. The application of this modified silica gel to preconcentration of pond water, tap water and drinking water gave high accuracy and precision (%R.S.D. ≤ 9). The method detection limits were 22.5, 1.0, 2.9, 0.95, 1.1 μg/L for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively.  相似文献   

8.
《Analytical letters》2012,45(5):1009-1021
Abstract

Application of morpholine dithiocarbamate (MDTC) coated Amberlite XAD‐4, for preconcentration of Cu(II), Cd(II), Zn(II), Pb(II), Ni(II) and Mn(II) by solid phase extraction and determination by inductively coupled plasma (ICP) atomic emission spectrometry (AES) was studied. The optimum pH values for quantitative sorption of Cu(II), Cd(II), Zn(II), Pb(II), Ni(II), and Mn(II) were 6.5–8.0, 7.0–8.5, 6.0–8.5, 6.5–8.5, 7.5–9.0, and 8.0–8.5, respectively. The metals were desorbed with 2 mol L?1. The t1/2 values for sorption of metal ions were 2.6, 2.9, 2.5, 2.6, 3.0, and 3.8 min respectively for Cu(II), Cd(II), Zn(II), Pb(II), Ni(II) and Mn(II). The effect of diverse ions on the determination of the previously named metals was studied. Simultaneous enrichment of the six metals was accomplished, and the method was applied for use in the determination of trace metal ions in seawater samples.  相似文献   

9.
Two novel azocalix[4]pyrrole Amberlite XAD-2 polymeric chelating resins were synthesized by covalently linking diazotized Amberlite XAD-2 with calix[4]pyrrole macrocycles. The chelating resins were used for extraction, preconcentration and sequential separation of metal ions such as Cu(II), Zn(II) and Cd(II) by column chromatography prior to their determination by UV/vis spectrophotometry or flame atomic absorption spectrophotometry (FAAS) or inductively coupled plasma atomic emission spectroscopy (ICP-AES). Various parameters such as effect of pH on absorption, concentration of eluting agents, flow rate, total sorption capacity, exchange kinetics, preconcentration factor, distribution coefficient, breakthrough capacity and resin stability, were optimized for effective separation and preconcentration. The resin showed good ability for the separation of metal ions from binary and ternary mixture on the basis of pH of absorption and concentration of eluting agents. The newly synthesized resins showed good potential for trace enrichment of Cu(II), Zn(II) and Cd(II) metal ions, especially for Cu(II), as compared to the earlier reported resins. The synthesized resins were recycled at least 8-10 times without much affecting column sorption capacity. The presented method was successfully applied for determination of Cu(II), Zn(II) and Cd(II) in natural and ground water samples.  相似文献   

10.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

11.
The dynamic adsorption and desorption properties, including the effect of pH value and flow rate on the adsorption, eluent acidity and volume, eluting velocity and re-use, of Cu(II), Pb(II), Zn(II), Cd(II), Mn(II), Ni(II), Co(II) and Hg(II) ions on the column loaded with poly(acrylaminophosphonic-carboxyl-hydrazide) chelating fiber were investigated. The recovery of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions in the presence of Na, K, Ca and Mg ions was examined. The preconcentration of trace amounts of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions from model solution samples was carried out with satisfactory results. The amount of the metal ions detected after preconcentration and recovery by this technique was basically in agreement with the added amount. The method is rapid, precise and simple. Received: 15 October 1997 / Revised: 17 March 1998 / Accepted: 20 March 1998  相似文献   

12.
The dynamic adsorption and desorption properties, including the effect of pH value and flow rate on the adsorption, eluent acidity and volume, eluting velocity and re-use, of Cu(II), Pb(II), Zn(II), Cd(II), Mn(II), Ni(II), Co(II) and Hg(II) ions on the column loaded with poly(acrylaminophosphonic-carboxyl-hydrazide) chelating fiber were investigated. The recovery of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions in the presence of Na, K, Ca and Mg ions was examined. The preconcentration of trace amounts of Mn(II), Co(II), Cd(II), Ni(II) and Zn(II) ions from model solution samples was carried out with satisfactory results. The amount of the metal ions detected after preconcentration and recovery by this technique was basically in agreement with the added amount. The method is rapid, precise and simple. Received: 15 October 1997 / Revised: 17 March 1998 / Accepted: 20 March 1998  相似文献   

13.
Kumar M  Rathore DP  Singh AK 《Talanta》2000,51(6):1187-1196
A stable chelating resin matrix was synthesized by covalently linking o-aminophenol (o-AP) with the benzene ring of the polystyrene–divinylbenzene resin, Amberlite XAD-2, through a –N=N– group. Elemental analyses, thermogravimetric analysis (TGA) and infrared spectra have characterized the resulting chelating resin. It has been used to preconcentrate Cu2+, Cd2+, Co2+, Ni2+, Zn2+ and Pb2+, prior to their determination by flame atomic absorption spectrometry. The optimum pH values for quantitative sorption of Cu, Cd, Co, Ni, Zn and Pb are 6.2–7.4, 5.6–7.2, 5.6–9.0, 6.0–9.0, 5.7–7.0 and 5.0–6.0, respectively. These metals are desorbed (recovery 91–98%) with 4 mol dm−3 HNO3. The sorption capacity of the resin is 3.37, 3.42, 3.29, 3.24, 2.94 and 3.32 mg of metal g−1 of resin, respectively, for Cu, Cd, Co, Ni, Zn and Pb. The effect of NaF, NaCl, NaNO3, Na2SO4, and Na3PO4 on the sorption of these metal ions has been investigated. These electrolytes are tolerable up to 0.01 mol dm−3 in case of all the metal ions, except Cl which is tolerable even up to 0.1 mol dm−3 for Zn and 1.0 mol dm−3 for Pb. The preconcentration factor for Cu, Cd, Co, Ni, Zn and Pb are 50, 50, 100, 65, 40 and 40 (concentration level 10–25 μg dm−3) respectively. Simultaneous enrichment of the six metals is possible. The method has been applied to determine Cu, Cd, Co, Ni, Zn and Pb content in well water samples (RSD≤8%).  相似文献   

14.
Goswami A  Singh AK 《Talanta》2002,58(4):669-678
A new chelating matrix has been prepared by immobilizing 1,8-dihydroxyanthraquinone (DHAQ) on silica gel modified with (3-aminopropyl)triethoxysilane. After characterizing the matrix with thermogravimetric analysis (TGA), cross polarization magic angle spinning (CPMAS) NMR and diffuse reflectance infrared fourier transformation (DRIFT) spectroscopy, it has been used to preconcentrate Pb(II), Cd(II) and Zn(II) prior to their determination by flame atomic absorption spectrometry. The optimum pH ranges for quantitative sorption are 6.0-7.5, 7.0-8.0 and 6.0-8.0 for Pb, Zn, and Cd, respectively. All the metal ions can be desorbed with 2 mol l(-1) HCl/HNO(3). The sorption capacity of the matrix has been found to be 76.0, 180.0 and 70.2 mumol g(-1) for Pb, Zn and Cd, respectively, with the preconcentration factor of approximately 200. The limits upto which electrolytes NaNO(3), NaCl, NaBr, Na(2)SO(4), Na(3)PO(4) sodium citrate, EDTA, glycine and humic acid and cations Ca(II), Mg(II), Cu(II), Co(II), Ni(II), Mn(II) Al(III), Cr(III) and Fe(III) can co-exist with the metal ions during their sorption without any adverse effect are reported. The lowest concentration of metal ions for quantitative recovery is 5.0 ng ml(-1) The simultaneous enrichment and determination of all the metals is possible if total load of metal ions is less than sorption capacity. The flame AAS was used to determine these metal ions in underground, tap and river water samples (relative standard deviation (R.S.D.)相似文献   

15.
The complexes formed between IE11 and Cd(II), Cr(III), Cu(II), Mn(II) and Pb(II) were identified and confirmed by IR, UV and pH-metric titration. The uptake behavior of porous silica modified with N-propylsalicylaldimine (IE11) and these metal ions were studied. Log k(d) was found to be within the range 2.19-5.16 depending on pH and time of stirring. IE11 was used in the separation and preconcentration of Cd(II), Cr(III, VI), Cu(II), Mn(II, VII) and Pb(II) from some natural water samples. Data were compared with those obtained by the solvent extraction method APDC/MIBK. The proposed methodology allows to verify an improvement in the water quality of Nile River probably attributed to high to moderate floods in the last few years. The method was found to be accurate and not subject to random error, i.e. precise.  相似文献   

16.
Conditions for the preparation of Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) 4-methylphthalates were investigated and their composition, solubility in water at 295 K and magnetic moments were determined. IR spectra and powder diffraction patterns of the complexes prepared with molar ratio of metal to organic ligand of 1.0:1.0 and general formula: M [ CH3C6H3(CO2)2nH2o (n=1-3) were recorded and their decomposition in air were studied. During heating the hydrated complexes are dehydrated in one (Mn, Co, Ni, Zn, Cd) or two steps (Cu) and next the anhydrous complexes decompose to oxides directly (Cu, Zn), with intermediate formation of carbonates (Mn, Cd), oxocarbonates (Ni) or carbonate and free metal (Co). The carboxylate groups in the complexes studied are mono- and bidentate (Co, Ni), bidentate chelating and bridging (Zn) or bidentate chelating (Mn, Cu, Cd). The magnetic moments for paramagnetic complexes of Mn(II), Co(II), Ni(II) and Cu(II) attain values 5.92, 5.05, 3.36 and 1.96 M.B., respectively. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

17.
Jain VK  Sait SS  Shrivastav P  Agrawal YK 《Talanta》1997,45(2):397-404
A very stable chelating resin matrix was synthesized by covalently linking o-vanillinthiosemicarbazone (oVTSC) with the benzene ring of the polystyrene-divinylbenzene resin Amberlite XAD-2 through a -NN- group. The resin was used successfully for the separation and preconcentration of copper(II), zinc(II) and lead(II) prior to their determination by atomic absorption spectrophotometry. The total sorption capacity of the resin was 850, 1500 and 2000 mug g(-1) of the resin for Cu(II), Zn(II) and Pb(II), respectively. For the quantitative sorption and recovery of Cu(II), Zn(II) and Pb(II), the optimum pH and eluants were pH 2.5-4.0 and 4 M HCl or 2 M HNO(3) for Cu(II), pH 5.5-6.5 and 1.0-2.0 M HCl for Zn(II) and pH 6.0-7.5 and 3 M HCl or 1 M HNO(3) for Pb(II). Both, the uptake and stripping of these metal ions were fairly rapid, indicating a better accessibility of the chelating sites. The t (1 2 ) values for Cu(II), Zn(II) and Pb(II) were also determined. Limit of tolerance of some electrolytes like NaCl, NaF, NaNO(3), Na(2)SO(4) and Na(3)PO(4) have been reported. The preconcentration factor for Cu(II), Zn(II) and Pb(II) was 90, 140 and 100 respectively. The method was applied for the determination of Cu(II), Zn(II) and Pb(II) in the water samples collected from Sabarmati river, Ahmedabad, India.  相似文献   

18.
Ramesh A  Rama Mohan K  Seshaiah K 《Talanta》2002,57(2):243-252
Preconcentration of Cd(II), Cu(II), Mn(II), Ni(II), Pb(II) and Zn(II) in saline matrices on Amberlite XAD-4 resins coated with ammonium pyrrolidine dithiocarbamate (APDC) and piperidine dithiocarbamate (pipDTC) and subsequent determination by inductively coupled plasma atomic emission spectrometry were studied. Parameters such as effect of pH, effect of HNO(3) concentration on elution of metals from resin were studied. The results show that Amberlite XAD-4 coated with APDC was more efficient in the recovery of metal ions compared with Amberlite XAD-4 coated with pipDTC, in the concentration range of 0.1-200 mug l(-1), for 1 g of Amberlite XAD-4 coated resin. The detection limits for Cd(II), Cu(II), Mn(II), Ni(II), Pb(II), Zn(II) are 0.1, 0.4, 0.3, 0.4, 0.6, 0.5 mug l(-1), respectively, for resin coated with APDC and 0.7, 1.0, 0.8, 0.9, 1.7 and 1.2 mug l(-1) for resin coated with pipDTC. The effect of diverse ions on the determination of aforesaid metals was studied. The method was applied for the determination of trace metal ions in artificial sea water and natural water samples. The results were compared with extraction AAS method.  相似文献   

19.
A simultaneous preconcentration procedure for the determination of Cd(II), Ni(II), Co(II) and Cu(II) by atomic absorption spectrometry is described. The method is based on solid phase extraction of the metal ions on dithizone loaded on naphthalene in a mini-column, elution with nitric acid and determination by flame atomic absorption spectrometry. The sorption conditions including NaOH concentration, sample volume and the amount of dithizone were optimized in order to attain the highest sensitivity. The calibration graph was linear in the range of 0.5–75.0 ng ml?1 for Cd(II), 1.0–150.0 ng ml?1 for Ni(II), 1.0–150.0 ng ml?1 for Co(II) and 1.0–125.0 ng ml?1 for Cu(II) in the initial solution. The limit of detection based on 3Sb was 0.13, 0.32, 0.33 and 0.43 ng ml?1 for Cd(II), Ni(II), Co(II) and Cu(II), respectively. The relative standard deviations (R.S.D) for ten replicate measurements of 20 ng ml?1of Cd(II), 100 ng ml?1 of Ni(II), Co(II) and 75 ng ml?1 of Cu(II) were 3.46, 2.43, 2.45 and 3.26%, respectively. The method was applied to the determination of Cd(II), Ni(II), Co(II) and Cu(II) in black tea, tap and river water samples.  相似文献   

20.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号